500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
RELAYIOMINI Tripp Lite UPS CONTACT CLOSURE MGT ACC CARD visit Digikey Buy
RELAYIOCARD Tripp Lite PROGRAMMABLE I/O CARD SMART UPS visit Digikey Buy
IR-1900-RELAY-CRM/CRF TE's AMP RELAY 4PDT 220VAC visit Digikey Buy
IR-1900-RELAY-1CR/2CR TE's AMP RELAY DPST 220VAC visit Digikey Buy
VI800A-RELAY FTDI Chip RELAYS OPTO-ISOLATED INPUTS BRID visit Digikey Buy
IR-1900-RELAY-3CR/4CR TE's AMP RELAY DPDT 220VAC visit Digikey Buy

156 relay

Catalog Datasheet MFG & Type PDF Document Tags

midtex relay 156

Abstract: midtex 155 /3 horsepower motor control applications at 120/240 VAC · The Type 158 relay is physically identical to the Type 156 relay. · The Midtex Type 158 is recognized under the Component Program of UL 508. UL , GENERAL PURPOSE RELAY TYPE 158 TYPE 158 FEATURES: · Type 158 relays are designed for UL , circuit capacity of circuit is fuse limited to levels of relay rating. CSA File LR54109 Max , 19 TYPE 158 PART NUMBERING SYSTEM Relay Type Enclosure and Terminals Contact Arr. Coil
CII Technologies
Original
E55708 midtex relay 156 midtex 155 156 relay midtex 156 midtex relays midtex relay VDC/120VAC VDC/120 90VDC

EC381V-05P

Abstract: PAM04AN3APO PAM 06 156 Relay module Photoelectric relay module Number of channels Number of relays per channel Relay type PAM 06 156 Specifications Relay Module Rated operational voltage Resistive , , alarm · DIN-rail mountable closed housing · Optional relay output Preliminary Ordering Key , crosstalk. An additional module is available with relay outputs for 6 channels. PAM06AN3ANOxxxx , +50°C (-4° to +122°F) -50° to +85°C (-58° to 185°F) 85 g (4 channels) Yes Type Selection Relay
Carlo Gavazzi
Original
EC381V-05P PAM04AN3APO PAM10AN3APC EC381V sound activated switch kit PAM02AN3ANC PAM06AN3ANO

power flex 700 vfd motor wiring diagram

Abstract: 0510 hp errors. The ArmorStart offers, as standard, four DC inputs and two relay outputs, to be used with , LED status indication. Outputs Two dual-key relay output connectors are supplied as standard. The
Rockwell Automation
Original
power flex 700 vfd motor wiring diagram 0510 hp 280-M35F-M1 wiring diagram dol motor starter em 495 b12 motor 280-T35 280D/281D 280-UM004A-EN-P

wiring diagram dol motor starter

Abstract: 1732DS-IB8XOBV4 errors. The ArmorStart offers, as standard, four DC inputs and two relay outputs, to be used with , , or 284A. Outputs Two dual-key relay output connectors are supplied as standard. The outputs are , . Two dual-key relay output connectors are supplied as standard. The outputs are sourced from control , control power is removed, the output contact opens. There is no switching element, such as a relay, in
Rockwell Automation
Original
1732DS-IB8XOBV4 3 phase motor soft starter circuit diagram ROCKWELL 281G DOL reversing wiring diagram motor starter Allen-Bradley soft starter dol starter 280G/281G 280G-UM001B-EN-P 280G-UM001A-EN-P

280d-fn-10-c

Abstract: wiring diagram dol motor starter Power supply S 114 156, S 114 166 Mode of Operation Power supply Pulse input 1. Relay on 2 , Timers Pulse Continuity Relay Type S 114 · 4 selectable time ranges: 0.15 s to 800 s · , connection for Namur sensor · Output: 10 A SPDT or 8 A DPDT relay · Plug-in type module · S -housing · LED-indication for relay and power supply on · AC or DC power supply Product Description Ordering Key Pulse continuity, plug-in control relay for monitoring e.g. movements of pistons or objects on a
Rockwell Automation
Original
280d-fn-10-c how to control dol starter by plc vfd and dol bypass power and control wiring diagram soft starter for a 415 volt three phase induction vfd and dol bypass circuit diagram Bradley smc-3 280-UM002A-EN-P 280-UM001F-EN-P 283-UM001E-EN-P 284UM001F-EN-P

166 relay

Abstract: 156 relay Repeatability deviation: 1% · Direct connection for NPN sensor · Output: 10 A SPDT relay or 8 A DPDT relay · Plug-in type module · S-housing · LED-indication for relay and power supply on · AC or DC power supply Product Description Multi interval, plug-in time relay with 4 selectable time ranges up to 800 s and 4 , contact, open collector output or sensor. S 112 156 024 Housing Type/function Output Power supply , Supply: 24 VDC Circular SPDT DPDT 0.15 -800 s 0.15 -800 s S 112 156 024 S 112 166 024 S
Carlo Gavazzi
Original
166 relay 156 relay 724 12 volt 5 pin relay 12 Volt DPDT Relay dipswitch proximity 7200

5 pins relay pin diagram

Abstract: SPDT relay 12 Volt Output Specifications S 1221 156 Output SPDT relay Basic electrical insulation 250 VAC (rms , sensor · Output: 10 A SPDT relay or 8 A DPDT relay · Plug-in type module · S-housing · LED-indication for relay and power supply on · AC or DC power supply Product Description Ordering Key Multi delay on operate and multi interval, plug-in time relay with 20 selectable time ranges up to 220 h , supply due to the combination and variety of voltages, functions and time ranges. S 1221 156 024
Carlo Gavazzi
Original
5 pins relay pin diagram SPDT relay 12 Volt S112166 SPDT 5 pins Relay 72424VDC relay 112

SM 1221

Abstract: 156 relay 724 direction relay · Measures up to 132 kW · Knob-adjustable power level · Built-in adjustable timer function · Output: 10 A SPDT relay · Plug-in type module · S-housing · LED-indication for power supply , metering relay. Measures power and direction of the mains from power plant or generator. Connected to Housing Type Output Power supply other Carlo Gavazzi modules, this relay can act as an element to avoid wrong transmission of power. S 1821 156 024 Type Selection Plug Output Supply: 24
Carlo Gavazzi
Original
SM 1221 PE Relay 9 Volt DPDT Relay 230 v relay relay 220 vdc 14 pins S1221166

carlo gavazzi SM 125 230

Abstract: VOLTAGE LEVEL RELAY SM 125 230 DPDT relay · Plug-in type module · S -housing · LED-indication for relay and power supply on · AC , a conveyor belt after a given time period. S 111 156 024 Type Selection Plug Output , SPDT DPDT 0.15 -800 s 0.15 -800 s S 111 156 024 S 111 166 024 S 111 156 115 S 111 166 115 S 111 156 230 S 111 166 230 S 111 156 724 S 111 166 724 Time Specifications Time ranges , rated power supply and ambient temperature Reset Time and relay Pulse duration Power supply
Carlo Gavazzi
Original
carlo gavazzi SM 125 230 VOLTAGE LEVEL RELAY SM 125 230 relay SM-125 411BS current LEVEL RELAY SM 115 230 11 pin 24 Volt DC relay

12 volt 5 pin relay

Abstract: 166 relay transient protection volt. S 110 156 SPDT relay 250 VAC (rms) (contact/electronics) µ (micro gap) 10 , Information". Power supply S 110 156, S 110 166 Operation Diagram Power supply 1. Relay on 2. Relay , '¢ Repeatability deviation: ≤ 1% â'¢ Output: 10 A SPDT or 8 A DPDT relay â'¢ Plug-in type module â'¢ S -housing â'¢ LED-indication for relay and supply on â'¢ AC or DC power supply Product Description Ordering Key Multi-function, plug-in time relay with 4 selectable time ranges up to 800 s and 4
Carlo Gavazzi
Original
Contact Electronics npn sensor 5 volt dpdt 8 pin relay
Abstract: Current and Voltage Controls 3-Phase Asymmetrical Relay Type H 471 · Mains network quality and load monitoring relay · Monitors phase sequence, phase loss, phase asymmetry and phase angle · , Knob-adjustable asymmetry sensitivity · Output: 10 A SPDT relay · For mounting on DIN-rail in accordance with , -phased measuring voltage Product Description 3-phase monitoring relay for DIN-rail mounting for phase , asymmetry in order to prevent any damage to the connected motors. H 471 156 380-50 Hz Housing Type Carlo Gavazzi
Original

H 471 156

Abstract: rotation monitoring meter deviation: 1% · Output: 10 A SPDT or 8 A DPDT relay · Plug-in type module · S -housing · LED-indication for relay and supply on · AC or DC power supply Product Description Ordering Key Multi-function, plug-in time relay with 4 selectable time ranges up to 800 s and 4 selectable modes of opera , monitored by power supply. S 110 156 024 Type Selection Plug Output Time range Supply: 24 VAC Circular SPDT DPDT 0.15 s-800 s 0.15 s-800 s Supply: 115 VAC S 110 156 024 S 110
Carlo Gavazzi
Original
H 471 156 rotation monitoring meter h471 3x415 phase line, phase asymmetry

156 relay

Abstract: 166 relay 19x 156 SPDT relay 250 VAC (rms) (cont./elec.) Output Rated insulation voltage Contact ratings , SPDT or 8 A DPDT output relay · LED-indications: Power supply and relay ON · AC power supply S195 , , the sensitivity is half as large. Housing Type/function Output Power supply S 195 156 024 , Circular Circular Circular SPDT DPDT SPDT DPDT S 195 156 024 S 195 166 024 S 196 156 024 S 196 166 024 S 195 156 115 S 195 166 115 S 196 156 115 S 196 166 115 S 195 156 230 S 195 166
Carlo Gavazzi
Original
110 156 230 delay timer with relay dpdt relay

S 196 156 230

Abstract: 156 relay direction relay · For symmetrical loads · Measures power up to 410 kW divided into 8 ranges · Knob-adjustable power set point · Built-in adjustable timer function · Output: 10 A SPDT relay · Plug-in type , -phased measuring voltage Product Description Ordering Key 3-phase power metering and direction relay , time delay. S 1822 156 220 Type Selection Plug Output Supply: 220 VAC Supply: 380 VAC Supply: 400 VAC Supply: 415 VAC Circular SPDT S 1822 156 220 S 1822 156 380 S 1822 156
-
Original
S 196 156 230 datasheet transistor S196 transistor s196 S196166 s196 relay 5 pin out diagram

3-phase monitoring relays circuit diagram

Abstract: 156 relay change without notice (07.01.00) 1 S 1201 Output Specifications S 1201 156 Output SPDT relay , deviation: 1% · Output: 10 A SPDT or 8 A DPDT relay · Plug-in type module · S-housing · LED-indication for relay and power supply on · AC or DC power supply Product Description Ordering Key , monitored by power supply. S 1201 156 024 Type Selection Plug Output Time range Supply: 24 , 0.15 s-220 h S 1201 156 024 S 1201 166 024 S 1201 156 115 S 1201 166 115 S 1201 156 230 S
Carlo Gavazzi
Original
3-phase monitoring relays circuit diagram 220 VAC to 12 VDC circuit diagram transformer AC 220 dc 12 S1822

relay 1201 166

Abstract: relay 1201 ) 1 S 1201 Output Specifications S 1201 156 Output SPDT relay Basic electrical insulation , S 1201 156, S 1201 166 200 g 125 g UL, CSA Mode of Operation Interval timer The relay , â'¢ Repeatability deviation: ≤ 1% â'¢ Output: 10 A SPDT or 8 A DPDT relay â'¢ Plug-in type module â'¢ S-housing â'¢ LED-indication for relay and power supply on â'¢ AC or DC power supply , tion. Available in various voltages to cover applications monitored by power supply. S 1201 156 024
Carlo Gavazzi
Original
relay 1201 166 relay 1201 1S1201 230 volt ac 12 volt ac 12 VOLT RELAY
Abstract: Specifications S 19x 156 SPDT relay 250 VAC (rms) (cont./elec.) Output Rated insulation voltage Contact , SPDT or 8 A DPDT output relay · LED-indications: Power supply and relay ON · AC power supply S195 , , the sensitivity is half as large. Housing Type/function Output Power supply S 195 156 024 , Circular Circular Circular SPDT DPDT SPDT DPDT S 195 156 024 S 195 166 024 S 196 156 024 S 196 166 024 S 195 156 115 S 195 166 115 S 196 156 115 S 196 166 115 S 195 156 230 S 195 166 Carlo Gavazzi
Original

S 196 156 230

Abstract: S196 insulation voltage Rated transient protection volt. A 109 156 SPDT relay 250 VAC (rms) (contact , : 1% · Output: 10 A SPDT or 8 A DPDT relay · Plug-in type module · LED-indication for relay on · , 109 156 220M Type Selection Plug Output Time ranges Supply: 120 VAC, 24 VAC/DC Supply: 220 VAC, 24 VAC/DC Circular SPDT 1 s - 10 m 1 m -10 h A 109 156 120M A 109 156 120H A 109 156 220M A 109 156 220H DPDT 1 s - 10 m 1 m -10 h A 109 166 120M A 109 166 120H A
Carlo Gavazzi
Original
S 195 166 230 MARKING S196 S195 S411 S 196 100 230 7 pin relay pin out diagram

relay 109

Abstract: 166 relay · Plug-in module, S-housing · Output: 5 A SPDT relay · LED-indication for relay and power supply , , multifunction time relay with 10 selectable modes of operation and time ranges from 10 ms to 99 h. Function , , open collector output (NPN) or power supply. S 1331 156 230 Type Selection Plug Output Supply: 24 VAC Supply: 115 VAC Supply: 230 VAC Supply: 24 VDC Circular SPDT S 1331 156 024 S 1331 156 115 S 1331 156 230 S 1331 156 724 Time Specifications Output
Carlo Gavazzi
Original
relay 109 120M 220H
Showing first 20 results.