NEW DATABASE - 350 MILLION DATASHEETS FROM 8500 MANUFACTURERS

Datasheet Archive - Datasheet Search Engine

 

Catalog Search Results

Catalog Datasheet Results Type PDF Document Tags
Abstract: ) · Water level detection pump and water slider board (with touch pads and sliders) and a water , detection Interfaces directly with the MCU using SPI Bridge (MC33886 MC33886) is used to control the DC water , interface. · MC33886 MC33886 H-Bridge (water pump motor driver) · Option of installing a Dual Op-Amp to amplify , LED display · FreeMASTER GUI interface (RS232 RS232) · Input supply voltage +12V DC / 2A · Audio buzzer , MCU KIT33993DWBEVB KIT33993DWBEVB +5V Vdd +12V DC Power Supply PWM/direction · Application support ... Original
datasheet

2 pages,
1855.64 Kb

water level controlling water level sensor pc based security system using sensors water level sensor diagram human detection sensors pump motor 12v light sensing circuit using op-amp 12v dc pump water PUMP MOTOR human detection sensors circuit water pump MC33794 MC68HC908QB8 MC33794 abstract
datasheet frame
Abstract: or water level. Freescale's H-Bridge (MC33886 MC33886) is used to control DC water pump motor. On board , (water pump motor driver) > Option of installing a Dual Op-Amp to amplify weak E-Field signals > LED , GUI interface (RS232 RS232) > Input supply voltage +12V DC / 2A > Audio buzzer Typical applications , Application Usage > E-Field Imaging Device demonstration > Key pad detection > Water level , human touch and water level based on Freescale's Electric Field Imaging Device (MC33794 MC33794). This ... Original
datasheet

2 pages,
135.37 Kb

MC33886 mc33886 application 12v dc motor water pump water level TOUCH SCREEN MCU touch light control KIT33794DWBEVM file on water level sensor MC68HC908QB8 msdi microcontroller based led display buzzer 5V DC water pump MC33794 MC68HC908QB8 MC33794 abstract
datasheet frame
Abstract: Applications · Automotive systems · Cooling fan Simplified Application Drawing VBAT · Water pump VBAT VPUMP · Actuator controls 33927 · Fuel pump PUMP power steering PA_HS_G VPWR · , easily configured for systems driving brushless DC (BLDC), permanent magnet (PM) or switched reluctance (SR) motors with or without sensors. Typical applications include the cooling fan, water pump, fuel pump, electro-hydraulic and electric power steering. The MC33927 MC33927 device is extremely flexible and ... Original
datasheet

2 pages,
140.95 Kb

water SPI DC MOTOR FULL DRIVER 10A Electro-Hydraulic 12v dc motor water pump KIT33927EKEVBE MC33927 SG1002 SG187 drive motor 10A with transistor AN2409 all TRANSISTOR comparison GUIDE 12v dc water pump fuel pump MC33927 abstract
datasheet frame
Abstract: 33937 · Water pump VPUMP · Actuator controls · Fuel pump VSUP PUMP PA_HS_G VPWR , brushless DC (BLDC), permanent magnet (PM) or switched reluctance (SR) motors with or without sensors. Typical applications include the cooling fan, water pump, fuel pump, electro-hydraulic and electric , AMP_OUT R SEN functions required to control and protect a DC Benefits motor with up to , frequency DC to 20 kHz device setup and asynchronous reset, enable for over 25 years of ... Original
datasheet

2 pages,
115.6 Kb

12v dc pump water Electro-Hydraulic Electrohydraulic Power Steering KIT33937AEKEVBE 12v dc water pump AN2409 MCZ33937A SG1002 SG187 MCZ33937 TRANSISTOR comparison GUIDE MC33937 MC33937 abstract
datasheet frame
Abstract: predetermined water hardness level. The reagent is added to a known volume of sample via a small pump until a , Data Sheet Water Hardness Monitor SS/AW100 SS/AW100_3 Testomat AW101 AW101 Automatic on-line monitoring of residual/total water hardness ­ ideal for water softening and potable water plants , levels to be monitored A unique water hardness monitoring system with superior performance Water Hardness Monitor Testomat AW100 AW100 SS/AW100 SS/AW100_3 General The AW100 AW100 has been developed as a ... Original
datasheet

8 pages,
130.13 Kb

abb soft start EN61010-1 TH2005 th2025 TH2100 water level control alarm water level alarm circuit applications VOLTAGE REGULATOR 230V circuit diagram steam turbine automatic WATER pressure pump CONTROL AW101611 Water Level Monitoring diagram AW101902 SS/AW100 AW101 SS/AW100 abstract
datasheet frame
Abstract: V 3-Channel DC:DC Converter PRELIMINARY Electrical Characteristics VIN = 3.3V, VBOOST = 12V , (mA) 15V 250 450 12V 650 IOUT (mA) 4 850 1050 3-Channel DC:DC Converter , 12V, there are two 12 3-Channel DC:DC Converter PRELIMINARY approaches to reducing the voltage , EL7581C EL7581C 3-Channel DC:DC Converter PRELIMINARY where: Positive Charge Pump Design Considerations , -R 5 14 3-Channel DC:DC Converter PRELIMINARY Similar to positive charge pump, if ... Original
datasheet

17 pages,
253.94 Kb

MBRM120LT3 EL7581CRE BAT54S EL7581C EL7581C abstract
datasheet frame
Abstract: OR DER ING INFOR M AT ION .c g Nominal coil voltage : 6V , 12V , 24V , 48V Structure Type TRP 12V DC F A Contact material A : AgNi C : AgSnIn in h A s i- ta . , Indicators Y Interval Wipers Control Y Fuel Pump Control Y Ventilation Motor Y Hazard Lights Y Heater , DC) 6 12 24 48 6 12 24 48 Nominal Current (mA ) 353 160 80 44 315 136 67 37 , Voltage (V DC) Drop-Out Voltage (V DC) Max-A llowable Voltage (V DC) abt. 1.9 ~ 2.1 57% ... Original
datasheet

2 pages,
152.55 Kb

DC MOTOR 24V 500W DC MOTOR 12V 500W 12v dc motor water pump datasheet abstract
datasheet frame
Abstract: DC Brushless motor Driver Monolithic IC C Output Power Device : IGBT Charge Pump Driver , 3-phase Distrbution Charge Pump DC Brushless Motor Motor 10 50 Induction Motor 100 , Application Example of System configuration Jet bus water control Small pump Electrical-powered , of System configuration Consumer products such as washing machine Small pump Jet bus water , Predriver 6-input Bootstrap Predriver ECN3051/53 ECN3051/53 ECN3035/3036 ECN3035/3036 3-phase Distrbution Charge Pump ... Original
datasheet

40 pages,
1583.53 Kb

single phase inverter IC IGBT pwm 3phase igbt driver ic Single phase inverter CIRCUIT DIAGRAM 230V dc variable speed control pwm block diagram of air conditioner MBN1200D33A block diagram of energy saving MBM300nS12AW 3 phase brushless dc control ir2130 circuit diagram of energy saving device ecn3051 datasheet abstract
datasheet frame
Abstract: Applications · Sensor monitor and control Water level/pump actuator · Smoke detector · Simple user systems , Selectable through Jumpers · USB Cable: 5V DC, 500 mA max · 5V DC to 12V DC power jack: 2.5/5.5 mm barrel , Board Size 2.9" x 2.5" · Power Input: USB Cable-500 mA max PWR Connector-9V DC typical, +7V DC to +18V DC Freescale and the Freescale logo are trademarks or registered trademarks of Freescale ... Original
datasheet

2 pages,
727.7 Kb

12v dc water pump bread board digital clock project HCS08 MC9S08QG8 MC9S08QG8 IIC CODE PBMCUSLK PBS08QG8SLK 9v connector barrel DC Power Connector 5v project on water level control smoke alarm project HCS08 abstract
datasheet frame
Abstract: Motor Reverse Automatic Mirror Adjustment Fuel Pump Control Belt Tension Adjustment c . ORDERING INFORMATION Nominal coil voltage : 6V , 9V , 12V , 24V g in h s iStructure F : Flux Free Type S : Washable Type Type TR81 12V DC F C Contact material C : AgSnIn , Min. (at 500VDC 500VDC) w 300 operation/min 30 operation/min -40C to +85C (No water condensation and no water drop) 45 to 85% RH 40 deg. Max. (at rated coil voltage) 10 to 55HZ Double Amplitude 1.5mm ... Original
datasheet

2 pages,
144.69 Kb

TR81 circuit diagram of door lock system AT20 12v dc pump water wiper motor 12v dc 12v dc water pump wiring diagram for water pump datasheet abstract
datasheet frame

Extended Electronics Archive (Experimental)

Abstract Saved from Date Saved File Size Type Download
Over 1.1 million files (1986-2013): html articles, reference designs, gerber files, chemical content, spice models, programs, code, pricing, images, circuits, parametric data, RoHS data, cross references, pcns, military data, and more. Please note that due to their age, these files do not always format correctly in modern browsers. Disclaimer.
 
elements are capable of receiving, and possibly storing, power. In our water analogy, a pump would be an a transformer which steps the voltage down from the line voltage, usually to around 12V, which is current and voltage is water in a pipe. Current is analogous to the flow of water, while voltage is example of an insulator is the plastic on electrical cords. Using our water analogy, a conductor can be pipe which contains the water flow. Switch: used to control the flow of electrons, or current
www.datasheetarchive.com/files/international-rectifier/docs/wcd00009/wcd009b2.htm
International Rectifier 06/10/1998 17.43 Kb HTM wcd009b2.htm
elements are capable of receiving, and possibly storing, power. In our water analogy, a pump would be an a transformer which steps the voltage down from the line voltage, usually to around 12V, which is current and voltage is water in a pipe. Current is analogous to the flow of water, while voltage is example of an insulator is the plastic on electrical cords. Using our water analogy, a conductor can be pipe which contains the water flow. Switch: used to control the flow of electrons, or current
www.datasheetarchive.com/files/international-rectifier/technical-info/guide/circuit.html
International Rectifier 24/07/2000 22.21 Kb HTML circuit.html
ambient 90 5 C/W THERMAL RESISTANCE Symbol Test conditions Values Unit I GT V D = 12V (DC) R L = 140 W Tj=25 5 C MAX 10 mA V GT V D = 12V (DC) R L = 140 W Tj=25 5 C MAX 1 V V GD V OUT = V DRM R -motor - door lock - low power lamp bulb - pump - fan MAIN APPLICATIONS ASD ] 1/6 Symbol Parameter Value Unit V well adapted to washing machine, dishwasher, tumble drier, refrigerator , water heater and cookware. It , micro-motor, pump, fan, door lock and low wattage lamp bulb. Pin COM: Common drive reference to connect
www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/6519-v1.htm
STMicroelectronics 02/04/1999 10.83 Kb HTM 6519-v1.htm
ambient 90 5 C/W THERMAL RESISTANCE Symbol Test conditions Values Unit I GT V D = 12V (DC) R L = 140 W Tj=25 5 C MAX 10 mA V GT V D = 12V (DC) R L = 140 W Tj=25 5 C MAX 1 V V GD V OUT = V DRM R -motor - door lock - low power lamp bulb - pump - fan MAIN APPLICATIONS ASD ] 1/6 Symbol Parameter Value Unit V well adapted to washing machine, dishwasher, tumble drier, refrigerator , water heater and cookware. It , micro-motor, pump, fan, door lock and low wattage lamp bulb. Pin COM: Common drive reference to connect
www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/6519-v2.htm
STMicroelectronics 14/06/1999 10.79 Kb HTM 6519-v2.htm
GT V OUT =12V (DC) R L =140 W Tj=25 5 C MAX 10 mA V GT V OUT =12V (DC) R L =140 W Tj=25 5 C -motor - door lock - low power lamp bulb - pump - fan MAIN APPLICATIONS 1/7 Symbol Parameter Value Unit V DRM V washing machine, dishwasher, tumble drier, refrigerator , water heater and cookware. It has been designed especially to switch ON and OFF low power loads such as solenoid, valve, relay, micro-motor, fan, pump .15 solenoid Valve Dispenser Relay Micro-motor < 20 > 0.7 < 0.1 < 0.05 < 2 Pump Fan < 40 > 0.2 < 0.2 < 0.1 < 10
www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/6518-v1.htm
STMicroelectronics 02/04/1999 11.82 Kb HTM 6518-v1.htm
Symbol Test conditions Values Unit I GT V D = 12V (DC) R L = 140 W Tj=255 C MAX 10 mA V GT V D = 12V (DC) R L = 140 W Tj=255 C MAX 1 V V GD V OUT = V DRM R L = 3.3k W Tj=1105 C MIN 0.2 V , dispenser - micro-motor - door lock - low power lamp bulb - pump - fan MAIN APPLICATIONS ASD] AC device is well adapted to washing machine, dishwasher, tumble drier, refrigerator, water heater and , relay, micro-motor, pump, fan, door lock and low wattage lamp bulb. Pin COM: Common drive reference to
www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/6519.htm
STMicroelectronics 20/10/2000 13.2 Kb HTM 6519.htm
GT V OUT =12V (DC) R L =140 W Tj=25 5 C MAX 10 mA V GT V OUT =12V (DC) R L =140 W Tj=25 5 C -motor - door lock - low power lamp bulb - pump - fan MAIN APPLICATIONS 1/7 Symbol Parameter Value Unit V DRM V washing machine, dishwasher, tumble drier, refrigerator , water heater and cookware. It has been designed especially to switch ON and OFF low power loads such as solenoid, valve, relay, micro-motor, fan, pump .15 solenoid Valve Dispenser Relay Micro-motor < 20 > 0.7 < 0.1 < 0.05 < 2 Pump Fan < 40 > 0.2 < 0.2 < 0.1 < 10
www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/6518-v2.htm
STMicroelectronics 14/06/1999 11.78 Kb HTM 6518-v2.htm
15 14 20 11 10 18 17 16 19 1 5 6 0V FUSE USER INTERFACE 12V 100K association with electromechanical timers which drive power pumps or resistances and interface to the user : Fast battery charger (15W - CD/DC) BATTERY PACK 6V 1500mAH +Vbatt 100uF 25V + 5 3 N D 5 C/SEN 3 COMP 1 VFB 2 OUT 6 UC3843 UC3843 UC3843 UC3843 10K 15K 1nF 2A + DC products find applications in freon-free refrigerators, pumps, air conditioning, fans,. but no dramatic
www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/2526-v3.htm
STMicroelectronics 25/05/2000 21.42 Kb HTM 2526-v3.htm
20 11 10 18 17 16 19 1 5 6 0V FUSE USER INTERFACE 12V 100K 200K 200K 22K 100K 0V association with electromechanical timers which drive power pumps or resistances and interface to the user (15W - CD/DC) BATTERY PACK 6V 1500mAH +Vbatt 100uF 25V + 5 3 1 7 2 6 4 L4962 L4962 L4962 L4962 BYV10 BYV10 BYV10 BYV10 10K 15K 1nF 2A + DC + GND 11 TO 25V - 4.7uF 10V 220uF 25V 22nF 12K 2.2uF 10V I=1 -free refrigerators, pumps, air conditioning, fans,. but no dramatic breakthroughs are anticipated. The universal
www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/2526-v1.htm
STMicroelectronics 20/10/2000 22.26 Kb HTM 2526-v1.htm
FUSE USER INTERFACE 12V 100K 200K 200K 22K 100K 0V +5V 0V +5V 5V6 100mF 6V 220nF/400V 1N4148 1N4148 1N4148 1N4148 820-1/2W 820-1/2W 820-1/2W 820-1/2W association with electromechanical timers which drive power pumps or resistances and interface to the user. A from this basis. MICROCONTROLLERS IN HOME APPLIANCES 4 / 14 Figure 3: Fast battery charger (15W - CD/DC /CT 4 G N D 5 C/SEN 3 COMP 1 VFB 2 OUT 6 UC3843 UC3843 UC3843 UC3843 10K 15K 1nF 2A + DC + GND 11 TO 25V - 4.7uF 10V 220uF 25 find applications in freon-free refrigerators, pumps, air conditioning, fans,. but no dramatic
www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/2526-v2.htm
STMicroelectronics 14/06/1999 19.64 Kb HTM 2526-v2.htm