500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Search Stock

Shift+Click on the column header for multi-column sorting 
Part
Manufacturer
Supplier
Stock
Best Price
Price Each
Ordering
Part : ATSAMC21MOTOR Supplier : Microchip Technology Manufacturer : Avnet Stock : - Best Price : $57.6471 Price Each : $57.6471
Part : ATSAMC21MOTOR Supplier : Microchip Technology Manufacturer : Newark element14 Stock : - Best Price : $83.79 Price Each : $96.53
Part : ATSAMC21MOTOR Supplier : Microchip Technology Manufacturer : microchipDIRECT Stock : - Best Price : $56.00 Price Each : $56.00
Part : ATSAMC21MOTOR Supplier : Microchip Technology Manufacturer : Chip1Stop Stock : 21 Best Price : $63.6000 Price Each : $71.50
Shipping cost not included. Currency conversions are estimated. 

1/MOTOR PUMP

Catalog Datasheet MFG & Type PDF Document Tags
Abstract: COMPARATORS CO ^ w (A) TANK \ T H2 g WATER L EV E L TH , (B) NOTES: 1. Motor pump is â'ON' when water level rises above thermistor THS. 2. Motor pump remains â'ON" until water , Program mable Bias C urrent of 1|iA â'¢ Built-in H y steresis , , Thyristors, Solenoids, etc. â'¢ Signal Reconditioning â'¢ Phase and Frequency Modulators â'¢ On/Off Motor , +125°C 1. Differential amplifiers and summer: the circuit uses two differential amplifiers, one to -
OCR Scan
CA3098E CA3098 FIGURE30
Abstract: WATER LEVEL TH, (B) 1. Motor pump is â'˜ON* when water level rises above thermistor TH2. 2. Motor pump remains X)N* until water level falls below thermistor THV 3. Thermistors, operate in self , JAN 1 fl 1993 a* HARRIS CA3098 \J \J \J S E M I C O N D U C T O R January , . 150mA â'¢ Low Input On/Off Current of Less Than 1nA for Programmable Bias Current of 1^A â , Relays, Heaters, LEDs, Lamps, Photosensitive Devices, Thyristors, Solenoids, etc. 1. Differential -
OCR Scan
1-800-4-HARRIS
Abstract: T2301B MT2 PUMP MOTOR -6V (+) FIGURE 31A. WATER LEVEL CONTROL CIRCUIT NOTES: 1. Motor pump is "ON" when water level rises above thermistor TH2. 2. Motor pump remains "ON" until water level , Relays, Heaters, LEDs, Lamps, Photosensitive Devices, Thyristors, Solenoids, etc. 1. Differential , Modulators · On/Off Motor Switching · Schmitt Triggers, Level Detectors · Time Delays · , , LOW REF. 1 8 +IN I BIAS 2 7 HIGH REF. OUT 3 6 V+ V- 4 5 CURRENT Intersil
Original
water level control 12v dc motor water pump 1N914 MS-001-BA programmable schmitt trigger motor pump ISO9000
Abstract: WATER LEVEL 1 120VAC 4 10k T2301B MT2 PUMP MOTOR -6V (+) FIGURE 31A. WATER LEVEL CONTROL CIRCUIT NOTES: 1. Motor pump is "ON" when water level rises above thermistor TH2. 2. Motor pump remains "ON" until water level falls below thermistor TH1. 3. Thermistors, operate in self , -800 com 1 M ons arris. COM icati O RE ral Appl tapp@h N n Cent : ce Call or email , circuit function features (see Block Diagram): 1. Differential amplifiers and summer: the circuit uses Harris Semiconductor
Original
water level sensor schematic diagram schematic diagram water level control CA3098 data sheet 12v dc water pump
Abstract: 120VAC 4 10k T2301B NOTES: MT2 1. Motor pump is "ON" when water level rises above thermistor TH2. PUMP MOTOR 2. Motor pump remains "ON" until water level falls below thermistor TH1 , , LEDs, Lamps, Photosensitive Devices, Thyristors, Solenoids, etc. 1. Differential amplifiers and , a flip-flop. · Signal Reconditioning · Phase and Frequency Modulators · On/Off Motor Switching , CURRENT INPUT (IBIAS) 6 V+ OUTPUT CURRENT CONTROL "HIGH" REF. (HR) LOW REF. 1 8 Harris Semiconductor
Original
120vac to 12vdc schematic diagram
Abstract: \ TH2 TH-| WATER LEVEL NOTES: 1. Motor pump is "ON" when water level rises above thermistor TH2. 2. Motor pump remains "ON" until water level falls below thermistor TH-|. 3. Thermistors, operate in self , circuit function features (see Block Diagram): 1. Differential amplifiers and summer: the circuit uses , .150mA â'¢ Low Input On/Off Current of Less Than 1 nA for Programmable Bias Current of 1 jliA â'¢ Built-in , /Off Motor Switching Schmitt Triggers, Level Detectors Time Delays Overvoltage, Overcurrent -
OCR Scan
application of ca3098 HARRIS SEMICONDUCTOR IS09000
Abstract: i3 3 k2 TH, WATER LEVEL - r 1 NOTES: 1. Motor pump is â'ONâ' when water level rises above thermistorTH2. 2. Motor pump remains â'ONâ' until water level falls below thermistor TH , 150mA â'¢ Low Input On/Off Current of Less Than 1nA for Programmable Bias Current of 1|j.A â , Relays, Heaters, LEDs, Lamps, Photosensitive Devices, Thyristors, Solenoids, etc. 1. D ifferential am , flip-flop. â'¢ Signal Reconditioning â'¢ Phase and Frequency Modulators â'¢ On/Off Motor Switching â -
OCR Scan
5M-1982
Abstract: NOTES: MT2 1. Motor pump is â'ONâ' when water level rises above thermistor TH2. 2. Motor pump , . 150mA â'¢ Low Input On/Off Current of Less Than 1nA for Programmable Bias Current of 1|aA â , '¢ Signal Reconditioning â'¢ Phase and Frequency Modulators â'¢ On/Off Motor Switching â'¢ Tim e Delays , quiescent operating current and performance parameters. Ordering Information TEMP RANGE (°C) 1 , T | CURRENT â'" 1 CONTROL CAUTION: These devices are sensitive to electrostatic discharge. Users -
OCR Scan
43G2271
Abstract: from 1.0 to 2280 mL/Min (36 GPH) ß Mounts Directly onto OMEGAFLEX® Motor or Compatible Pump Motor , pump. One pump can be used for many different applications, or you can mount two pumps onto the motor , be used to mount the pump to a motor other than the FPU5-MT pump motor. The pump comes standard with , long mounting screws. FPU5-MT-110 pump motor shown with two FPU500 pumps. Specifications , . and Canada L R PU M P S OMEGAFLEX® Pump Motor Shown smaller than actual size. FPU5-MT Omega Engineering
Original
FPU5-MT-220 FPU500-AP FPU500-LMS FPU500-SMS FPU500-RA
Abstract: Rechargeable Battery Motor Pump Capability: 9 gpm, 4 ft. TDH Max. Fluid Viscosity: 100 cps,1.6 specific , 50 to 90 psig; 3 â"4 HP, 3,000 RPM) FPUD331 320 Air motor 2.3 (5) Accessories for Pump , Polypro Pump Tube, From $270 Shown smaller than actual size ODP Electric Motor , Motor DISCHARGE HEAD (FT.) MOST POPULAR MODELS HIGHLIGHTED! Pump Motors 65 55 45 35 25 , 4 2 0 Ordering Example: FPUD362, 110 Vac TEFC powered pump motor and, FPUD3-S40, 316 stainless Omega Engineering
Original
FPUD311-A 316SS FPUD300 FPUD311 FPUD321 FPUD350
Abstract: peristaltic pump mechanism is shown in Figure 1. The advancing roller occludes the tube which, as it recovers , peristaltic pump can speed its flow, control its flow rate, or dispense it in precise volumes. Figure 1 Peristaltic pump action 1 2 3 The flow rate depends mainly on the internal diameter of the tube , motor to form a complete sub-assembly. If the drive motor and pump head are to be mounted on an existing , Figure 4 Pump assembly - side view 43mm Pump head mounting screws 2 off Rotating roller DC motor RS RS Components
Original
100rpm DC motor sodium sulphide sodium silicate aniline hydroxide 33078 food and beverage stock sheet
Abstract: peristaltic pumping A typical peristaltic pump mechanism is shown in include: Figure 1. The advancing roller , ability to confine the fluid to a tube is Figure 1 Peristaltic pump action valuable. Instead of stripping , fitting between the pump head and the drive motor to form a complete sub-assembly. If the drive motor and , reversed by reversing the motor rotation. Figure 5 Tube loading on the pump head faces (see Figure 6). , fitting between the main pump head bayonet mount and the dive motor to form a complete sub-assembly. If RS Components
Original
12VDC water pump dc motor 100rpm RS stock no. 320-584 ethylene drive motor ammonium sulphate D10221
Abstract: G L Pumps ® AQUAVAR CPC (Centrifugal Pump Control) Installation and Operation Manual Goulds Pumps ITT Industries IM167R00 G L Pumps 1 Table of Contents Section 1 SAFETY Use of , . 24 Wiring IP 21 / UL Type 1 Enclosure with Conduit , . 51 Section 6 PROGRAMMING Single Pump Programming (Pressure Transducer) . 75 Single Pump â'" Submersible Pump Constant Pressure Goulds Pumps
Original
block diagram of suction pump CPC40441
Abstract: , German, or Italian The OMEGAFLEX FPU5-MT pump motor offers microprocessor control and a digital display , control software. Simply select a tubing size and the desired flowrate, and the pump motor locks in the , optional adaptor plate that can be used to mount the pump to a motor other than the FPU5-MT pump motor , @ 600 RPM, (in.) (in.) mL/Rev. mL/min ® Motor or Compatible Pump Motor â'¢ Easily , Thread! Ordering Example: FPU-500, peristaltic pump head, FPU5-MT-110, 110 Vac pump motor, $125 + 975 Omega Engineering
Original
Abstract: Pump Tube and Motor Supplied Separately for Maximum Flexibility ß CPVC, 316 SS or Sanitary Polished 316 SS Pump Tubes ß TEFC or Air Driven Motors ß For Fluids up to 2000 cps Viscosity and 1.8 , applications. The pump tube and motor are supplied separately in modular construction for maximum flexibility , Protection Kit, $252 Pump Motor MOST POPULAR MODELS HIGHLIGHTED! To Order (Specify Model Number , Wt. kg (lb) 8.1 (18) 8.1 (18) 1.8 (4) Type TEFC TEFC/IP54 Air Accessories for Pump Motor Omega Engineering
Original
FPUD400 FPUD431 FPUD411 FPUD34-SK FPUD345-FL FPUD4-C27
Abstract: presents a HITACHI high dielectric strength IC lineup for motor drives. In the description, DC means a 3-phase DC brushless motor and IM means an induction motor. 1. Inverter IC In these ICs, the IGTB of the , pump (200 V system) 2. Pre-driver IC As compared with the motor driver IC, these ICs do not , applicable motor capacity will be varied depend on a operating conditions. *Motor capacity Motor 40 W , For DC/IM (6-input type) Charge pump ECN3018 115 VAC 150 W or less - Hot water supply -
Original
ECN3067 ECN3053 ECN3053F ECN3030F refrigerator DC Inverter for compressor washing machine dc motor ECN3035 3 phase induction motor 8 kW washing machine water pump ECN3061 ECN3021 ECN3022 ECN3063 ECN3064
Abstract: PAGE 1 8 MOTOR SHAFT OUTPUT POWER MEASUREMENT SECTION ofTSM 750 POWER LOAD MONITOR ISSUE PAGE B 1 , discharge lines or other appropriate openings or connections. ● The pump drive system means (motor , motor current on the motor plate. 2. Compare this value with the Rated Motor Current in table 1. 3 , voltage. EXAMPLE â'¢ Rated motor current = 12 A. â'¢ Select 10. 1 - 12. 5 from the first column in , is 39 inches (1 m). FIGURE 4 Example: CTM O25 With 2 Windings For 12 A Motor Note! Normally Viking Pump
Original
viking b-2 class b viking b-2 class b transformer Viking Pump Viking B-2
Abstract: Basic Unit ß Pump Tube and Motor Supplied Separately for Maximum Flexibility ß 316SS or Sanitary Polished 316SS Pump Tubes Available ß TEFC or Air Driven Motors ß For Fluids up to 15,000 cps , variety of containers in various applications. The pump tube and motor are constructed modularly and , 3,000 air motor 100 psi @125 cfm n/a n/a n/a 12.7 (28) FPUD533 1,039 5 2 , *Too heavy for UPS shipment; use other motor freight. Accessories for Pump Motors Model No Omega Engineering
Original
FPUD500 FPUD531 FPUD513 FPUD521 FPUD524 FPUD525
Abstract: and shaded-pole motors. N L1 M 1~ Capacitor motor N L1 M 1~ Universal motor N L1 M 1~ Shaded-pole motor Fig. 1: Controllable AC motors on the KL2791 For , lubricant consumption Volume rate of flow Energy consumption Pump 1 Start-up phase 2 1st cut 3 , case the power consumption of the pump is affected; therefore, the use of the single-phase AC motor , Cooling lubricant consumption Volume rate of flow Energy consumption Pump 1 Start-up phase 2 1st BECKHOFF
Original
AC Motor Speed Controller motor operated valve AC Motors AC universal motor speed control variable frequency drive for ac motors DK9222-1009-0006
Abstract: . Route input power and motor wiring through conduits. 1. Install thin-wall conduit clamps (not , . Drive is properly grounded, with pump/motor. Input power (mains) voltage matches the drive nominal , Instruction Manual IM167 AQUAVAR CPC ® (Centrifugal Pump Control) installation and , reference for installing Aquavar CPC drives having a standard enclosure (NEMA 1). Application , . Overview Centrifugal Pump Controller Quick Start Guide AQUAVAR® CPC 2 â'" 230 Volt 370 Amps Xylem
Original
Showing first 20 results.