The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
ISL32741EFBZ-T7A Intersil Corporation PROFIBUS Compliant 6kV VDE-Reinforced Isolated RS-485 Transceiver; SOIC16; Temp Range: See Datasheet
ISL32741EIBZ Intersil Corporation PROFIBUS Compliant 6kV VDE-Reinforced Isolated RS-485 Transceiver; SOIC16; Temp Range: See Datasheet
ISL32741EFBZ Intersil Corporation PROFIBUS Compliant 6kV VDE-Reinforced Isolated RS-485 Transceiver; SOIC16; Temp Range: See Datasheet
ISL32741EFBZ-T Intersil Corporation PROFIBUS Compliant 6kV VDE-Reinforced Isolated RS-485 Transceiver; SOIC16; Temp Range: See Datasheet
ISL32741EIBZ-T Intersil Corporation PROFIBUS Compliant 6kV VDE-Reinforced Isolated RS-485 Transceiver; SOIC16; Temp Range: See Datasheet
ISL32741EIBZ-T7A Intersil Corporation PROFIBUS Compliant 6kV VDE-Reinforced Isolated RS-485 Transceiver; SOIC16; Temp Range: See Datasheet

vde 0551 Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
030-7309

Abstract: era bv 021-2029.0 fema transformers BV 020-5423.0 M bv 039-5305,0 l BV 048-5213.0 H BV 020-5383.0 M BV 039-5101.0 L BV 030-7307.0 030-7329-0
Text: Europe Type EE 20/6,1 Mini 0,35 VA Range available ex stock VDE 0551 /EN 60742 Potted under vacuum , available ex stock VDE 0551 /EN 60742 Potted under vacuum Split-bobbin transformers Temperature class t , 32-78 06-12 Type EE 20/10 Mini 0,5 VA Range available ex stock* VDE 0551 /EN 60742 Potted under , 32-78 06-12 Type EE 20/10 Mini 0,5 VA Range available ex stock * VDE 0551 /EN 60742 Potted under , Type El 30/5 0,5 VA Range available ex stock* VDE 0551 /EN 60742 Potted under vacuum Split-bobbin


OCR Scan
PDF D-71071 030-7309 era bv 021-2029.0 fema transformers BV 020-5423.0 M bv 039-5305,0 l BV 048-5213.0 H BV 020-5383.0 M BV 039-5101.0 L BV 030-7307.0 030-7329-0
2002 - transformer vde 0551

Abstract: vde 0551 AC DC power supply circuit diagram rectifier wiring diagram 87.230.0553.0
Text: terminal 22 ­ 12 AWG 0.5 ­ 2.5 mm2 0.5 ­ 4 mm2 VDE 0551 (EN 60742) TS 35 horizontal 4 kV 100% ED 0 °C.+40 °C ­40 °C.+85 °C Screw terminal 22 ­ 12 AWG 0.5 ­ 2.5 mm2 0.5 ­ 4 mm2 VDE 0551 (EN 60742) TS 35 , terminal 22 ­ 12 AWG 0.14 ­ 2.5 mm2 0.14 ­ 4 mm2 VDE 0551 (EN 60742) DIN 40050 (IP 20) TS 35 horizontal


Original
PDF
vde 0551

Abstract: power supply unit ng34 transformer vde 0551 sand filled 07NG Advant Controller 110
Text: and the secondary voltage according to VDE 0551 (safety electrical isolation).The power supply is , . Ambient temperature max. 55 °C (at 100 % load) Standards, regulations VDE 0160, transformer according to VDE 0551 110 x 110 mm (135 mm), see Fig. 11.2-2, Drilling Ordering data Order number


Original
PDF
vde 0551

Abstract: transformer vde 0551 automatic voltage circuit diagram 3 phase 3 phase transformer 3 phase power transformer Advant Controller 55 3 phase ac load control 3 phase frequency controller diagram NG 35 filter for phase ac 60 Hz
Text: primary and the secondary voltage according to VDE 0551 (safety electrical isolation). The secondary , , regulations VDE 0160, transformer according to VDE 0551 Ordering data Order number 2 07 NG 35 R1


Original
PDF
vde 0551

Abstract: transformer vde 0551 NG36 automatic voltage circuit diagram 3 phase star delta connection circuit diagrams
Text: secondary voltage according to VDE 0551 (safety electrical isolation). The secondary voltage is , max. 55 °C (at 100 % load) Standards, regulations VDE 0160, transformer according to VDE 0551


Original
PDF
ac DC supplies MEAN WELL schematic

Abstract: schematic diagram 230VAC to 24VDC POWER SUPPLY WEIDMULLER EMA i-i led display schematic 4000 watt power UPS circuit diagram 3000 watt ups circuit diagram vde 0550 T1 Schematic Circuit Diagram CP SNT 300W schematic diagram UPS 200 watt isolation converter weidmuller
Text: .3 Special regulations for isolating and control power transformers DIN VDE 0551 Regulations for safety , VDE 0551 VDE 0551 II I III 2 Uoff [V] II I III 2 Uoff [V] II I III 2 Uoff [V , 0551 VDE 0551 VDE 0551 VDE 0551 VDE 0551 II I III II I III II I III II I , category output Overvoltage category Input-output Pollution severity VDE 0551 VDE 0551 5 x 20 mm 250 mAT, primary at 115 V 100 mAT, primary at 220 V DIN 41571 VDE 0551 II I II I II


Original
PDF 50/60Hz ac DC supplies MEAN WELL schematic schematic diagram 230VAC to 24VDC POWER SUPPLY WEIDMULLER EMA i-i led display schematic 4000 watt power UPS circuit diagram 3000 watt ups circuit diagram vde 0550 T1 Schematic Circuit Diagram CP SNT 300W schematic diagram UPS 200 watt isolation converter weidmuller
VDE 0551 EN 60 742

Abstract: block transformers block VDE 0551 EN 60 742 IEC-742 TRANSFORMER 1034.txt vde 0551
Text: Block Transformers Visit Block Transformer’s Website at www.blockusa.com AVCM Range Dual Primary 115 V + 115 V Non Short Circuit Proof — NEW — Features Features (Continued) Description cDesign: Safety Isolating Transformer to VDE 0551 , EN 60 742, IEC 742 cOutput Voltage: Acc. to Table Twin , VDE 0551 , cTerminals: Pins for Printed Circuit Boards EN 60 742, IEC 742 Description — NEW — cTest , Proof — NEW — Features Features (Continued) cDesign: Safety Isolating Transformer to VDE 0551


Original
PDF 100-Up AVCM25/2/6 AVCM25/2/2 VDE 0551 EN 60 742 block transformers block VDE 0551 EN 60 742 IEC-742 TRANSFORMER 1034.txt vde 0551
VDE 0551 EN 60 742

Abstract: IEC-742 TRANSFORMER block VDE 0551 EN 60 742 transformer vde 0551 vde 0551 iec 742 EN 60 742 EN 60 742 transformer 18242x
Text: DIN EN 60 742, VDE 0551 , EN 60 742, IEC 742, IEC 61 558 ENEC 10 ( VDE ), UL, C-UL zwischen Ein- und , Input voltage Frequency Output voltage safety isolating transformer to DIN EN 60 742, VDE 0551 , EN 60 742, IEC 742, IEC 61 558 ENEC 10 ( VDE ), UL, C-UL between input and output circuit 5000 V, 50 Hz non-short-circuit-proof encapsulated prepared for class II equipment IP 00 + 40 °C VDE = B, UL = class 105 230 V 50 Hz to , °C VDE = B, UL = dass 105 230 V 50 Hz bis 60 Hz nach Tabelle Doppelspannung für Reihen- oder


OCR Scan
PDF Schraube3/1/15 VDE 0551 EN 60 742 IEC-742 TRANSFORMER block VDE 0551 EN 60 742 transformer vde 0551 vde 0551 iec 742 EN 60 742 EN 60 742 transformer 18242x
vde 0551

Abstract: transformer vde 0551 VDE0551
Text: according to VDE 0551 (safety electrical isolation). max. 120 mm, cable grips included 11.1 Mains , ) Standards, regulations VDE 0160, transformer according to VDE 0551 Ordering data Order number 2


Original
PDF
bs 3535

Abstract: AVEL G101000252
Text: EURORANGE TRANSFORMERS 230/240Vac PRIMARY TOROIDAL CONSTRUCTION HORIZONTAL OR VERTICAL FIXING OPTION THERMALLY PROTECTED PRIMARY FULLY ENCAPSULATED TO UL 94VO DUAL SECONDARIES LOW MAGNETIC FIELD LOW SURFACE TEMPERATURE CONFORMS TO EN 60/742 BS 3535 IEC 742 VDE 0551 UL 506 LOW INDUCED NOISE (AUDIBLE) DOUBLE INSULATED FLEXIBLE PVC LEADS CUSTOM WORK UNDERTAKEN THE PGUER PR0FESSI0NRLS AVEL , 150mm long ±5mm EN60/742, BS 3535, IEC 742, VDE 0551 , UL 506. 105°C Typs Load VA Secondary RMS


OCR Scan
PDF 230/240Vac bs 3535 AVEL G101000252
transformer vde 0551

Abstract: 12vdc to 415vac 220VAC to 24VDC transformer military switch 32012D Calex transformer 220Vac to 24Vdc 230V AC to 3V AC transformer 42024H 32205A
Text: approved to VDE 0551 ) Overall Dimensions l x w x h: 177.8 x 123.7 x <86.0mm Model 33012A 33012B , accordance with EN60950; IEC950; UL1950; and CSA 22.2 Transformer VDE 0551 Case Size (l x w x h) 119.2 x , accordance with EN60950, IEC 950, UL 1950 and CSA22.2 Transformer VDE 0551 Case Size `A' l x w x h 100 x , Exceeds the requirements of UL, CSA, VDE , IEC, BT, ECMA & CEE x Safety earth tag x 2 year warranty , circuit and overload conditions using pulse by pulse current limiting. x Inbuilt EMI filter, meets VDE


Original
PDF 12VDC 600mA 115/230VAC /-10VDC transformer vde 0551 12vdc to 415vac 220VAC to 24VDC transformer military switch 32012D Calex transformer 220Vac to 24Vdc 230V AC to 3V AC transformer 42024H 32205A
VDE 0660-209

Abstract: transformer vde 0551 vde 0660-209 en 1088 en 954-1 ip 67 0660-209 SHOCK SENSOR 1112 vde 0660-209 en 1088 Schmersal aes1102
Text: used with a suitable transformer to VDE 0551 . Note: Inductive loads (e.g. contactors, relays, etc , interlock monitoring module should only be used with a suitable transformer to VDE 0551 . Note: Inductive , removable guards with non-contact safety sensors to DIN VDE 0660-209. Design The safety module is of a , voltage Ue: IEC 204-1/EN 60204-1/ VDE 0113 Part 1; EN 1088; EN 954-1; DIN VDE 0660-209; BG-GS-ET 14 , ferrules) Terminals IP 20; Housing IP 40 as per IEC 529/EN 60529/DIN VDE 0470-1 AES 1102, AES 1112


OCR Scan
PDF 89/392/EWG VDE 0660-209 transformer vde 0551 vde 0660-209 en 1088 en 954-1 ip 67 0660-209 SHOCK SENSOR 1112 vde 0660-209 en 1088 Schmersal aes1102
VDE 0551 EN 60 742

Abstract: PT131 PT 13/1/pc50a
Text: Isolierstoffklasse des Isoliersystems : Sicherheitstransformator nach VDE 0551 , Design Approvals Test voltage , EN 60 742, IEC 742 : ENEC 10 ( VDE ), UL, C-UL : zwischen Ein- und Ausgangsstromkreisen 5000 V, 50 Hz : bedingt kurzschlußfest : vergossen : vorbereitet für Geräte der Schutzklasse II : IP00 : +40 °C : VDE = E, UL = dass 105 : safety Isolating transformer to VDE 0551 EN 60 742, IEC 742 : ENEC 10 ( VDE ), UL , : encapsulated : prepared for class II equipment : IP 00 : +40 °C : VDE = E,UL = class 105 Eingangsspannung


OCR Scan
PDF VDE30 VDE 0551 EN 60 742 PT131 PT 13/1/pc50a
block VDE 0551 EN 60 742

Abstract: VDE 0551 EN 60 742 VDE 0551 t 60 e 3122-X pcb transformer power transformer type E pt 100 M 222 PT131 transformer vde 0551
Text: Ausgangsspannung Sicherheits-Transformator nach DINEN 60 742, VDE 0551 , EN 60 742, IEC 742, IEC 61 558 ENEC 10 ( VDE ), UL, C-UL zwischen Ein- und Ausgangsstromkreisen 5000 V, 50 Hz bedingt kurzschlußfest vergossen vorbereitet für Geräte der Schutzklasse II IP00 + 40 °C VDE = E, UL = dass 105 230 V 50 Hz bis 60 Hz nach , safety isolating transformer to DIN EN 60 742, VDE 0551 , EN 60 742, IEC 742, IEC 61 558 ENEC 10 ( VDE ), UL , prepared for class II equipment IP 00 + 40 °C VDE = E, UL = class 105 230 V 50 Hz to 60 Hz acc. to table


OCR Scan
PDF
vde 0551

Abstract: No abstract text available
Text: isolation via transformer (4 kV, 8 mm creepage distance) Class II VDE 0551 Output relay (according to AC1


Original
PDF
profibus dp rs232

Abstract: sikostart dahlander simatic SIMATIC S7 Profibus
Text: EEx e SIMOCODE-DP EEx e "Increased safety" EN 50019 / DIN VDE 0165, DIN VDE 0170/0171 ATEX/PTB. SIMOCODE-DP 24 V DC, , DIN VDE 0551 . EU No.: PTB01 ATEX 3219 , RS232 ( IP54). SIMOCODE-DP ( 12, 01/2000) DIN VDE 0100/0106/0160, . .


Original
PDF
convel 41242

Abstract: convel convel 41122
Text: ; IEC950; UL1950; and CSA 22.2 VDE 0551 (l x w x h) 119.2 x 45 x 73.2mm. The case is rated to IP20


Original
PDF 100mA 500mA, EN60950; IEC950; UL1950; convel 41242 convel convel 41122
42024B

Abstract: 42024A 4202 transformer 110-220 transformer 220 volts 60 Hz specifications CSA22
Text: EN60950, IEC 950, UL 1950 and CSA22.2 VDE 0551 `A' l x w x h 100 x 70 x 112mm `B' l x w x h 162 x 105 x


Original
PDF 110/220VAC 50/60Hz 112mm 420xxA: 42024B: 2012A 2012A/2 2015A 42024B 42024A 4202 transformer 110-220 transformer 220 volts 60 Hz specifications CSA22
block VDE 0551 EN 60742

Abstract: transformer vde 0551 IEC-742 TRANSFORMER block VDE 0551 EN 60 742 VDE 0551 EN 60 742 24v transformer windings EN 60 742 transformer
Text: Data sheet: Stabilized DC Power Supply Type GLS - Description . : Compact stabilized dc power supply with integrated safety isolating transformer to VDE 0551 , DIN EN 60742, IEC 742 in accordance with DIN 19240,and UL 1012 Construction . : Enclosed in insulated housing, for DIN rail mounting , protection against electric shock according to VDE 0106 part 101 and finger safe according to UVV VBG4


Original
PDF
IEC-742 TRANSFORMER

Abstract: iec 742 Vickers EN 60742 VDE 0551 EN 60 742 a-35
Text: (12.13 lb) Protection IEC 364-4-41 or HD 384.04.41 (KDE 0100, Part 410) Transformer to VDE 0551 /EN 60742/IEC 742 Temperature range ­20_C to +60_C (­4_F to +140_F) Mounting attitude


Original
PDF EHA-PSU-704-A* EHA-PSU-704-A 115/230V GB-2419 IEC-742 TRANSFORMER iec 742 Vickers EN 60742 VDE 0551 EN 60 742 a-35
Class 130B transformer

Abstract: 130b TRANSFORMER POWER TRANSFORMER class 130B 130-B transformer vde 0551 en60742 Class 130B 115V transformer transformer vde 0551 EN60742 30va transformer microtran
Text: File 810/89 (EN60742 and VDE 0551 ). D. Mechanical Specifications: OUTPUT Date code and — country , 01 Ld m Ld O O F. Schematic Diagram: — 14.0±0.38[ 0.551 ±0.015] PRIMARY INPUT CONNECTIONS 1 , - 14.0±0.38[ 0.551 ±0.015] 7.0±0.38[0.276±0.015] OUTPUT 2X5.0V 2X6.3V 2X8.0V 2X10.0V


OCR Scan
PDF 115/230V 50/60Hz 10OMfi 500VDC, 100MQ LR69222 LR69223 E138028 506TY Class 130B transformer 130b TRANSFORMER POWER TRANSFORMER class 130B 130-B transformer vde 0551 en60742 Class 130B 115V transformer transformer vde 0551 EN60742 30va transformer microtran
transformer vde 0551 en60742

Abstract: vde 0551 PLT-30 30VA, 230v to 12v transformer vde 0551 en60742 LR69223 transformer vde 0551 3500-Vrms 230v to 12v transformer
Text: , General Purpose, File No. E79781. TUV File 810/89 (EN60742, and VDE 0551 ) D. Schematic Diagram; PRI SEC m


OCR Scan
PDF 115/230V 50/60Hz 100MQ 500VDC, 3500Vrms 1500Vrms 500Vrms PLT30-32-130B, LR69222 transformer vde 0551 en60742 vde 0551 PLT-30 30VA, 230v to 12v transformer vde 0551 en60742 LR69223 transformer vde 0551 3500-Vrms 230v to 12v transformer
24V "DC Motor"

Abstract: Calex Electronics 230 AC to 12V dc transformer transformer vde 0551
Text: approved to VDE 0551 ) Circuit breakers to provide easy access for connection to the input and output


Original
PDF 115/230VAC 50/60Hz 3750VAC 500VAC EN60950 24V "DC Motor" Calex Electronics 230 AC to 12V dc transformer transformer vde 0551
en60742 transformer

Abstract: PLT56-32 transformer vde 0551 en60742 transformer vde 0551 vde 0551 en60742
Text: Construction only UL 506, General Purpose, File No. E79781. TUV File 810/89 (EN60742, and VDE 0551 ) D


OCR Scan
PDF 115/230V 50/60Hz 100MQ 500VDC, 3500Vrms 1500Vrms 500Vrms PLT56-32, ACAD\MXFMR\A1125181 en60742 transformer PLT56-32 transformer vde 0551 en60742 transformer vde 0551 vde 0551 en60742
VDE 0551 EN 60 742

Abstract: transformer vde 0551 block VDE 0551 EN 60 742 VDE 0551 t 60 e isolating transformers type TIM transformer specification
Text: Data sheet: isolating transformers type TIM Description.: isolating transformer Approval. : VDE 0551 /EN 60 742 Test voltage. : PR1 - SEC Short-circuit protection 5000 V, 50 Hz V ^T :short-circuit proof Construction. : potted in insulated housing Protection c la s s .: protection class II Protection in d e x .: IP 20 Max ambient temperature + 40 °C Insulation class o f the


OCR Scan
PDF 0551/EN 2x115 VDE 0551 EN 60 742 transformer vde 0551 block VDE 0551 EN 60 742 VDE 0551 t 60 e isolating transformers type TIM transformer specification
Supplyframe Tracking Pixel