The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
LT1112CJ8 Linear Technology IC DUAL OP-AMP, 130 uV OFFSET-MAX, 0.65 MHz BAND WIDTH, CDIP8, CERDIP-8, Operational Amplifier
LT1114MJ/883B Linear Technology IC QUAD OP-AMP, 130 uV OFFSET-MAX, 0.65 MHz BAND WIDTH, CDIP14, CERDIP-14, Operational Amplifier
LT1112MJ8/883B Linear Technology IC DUAL OP-AMP, 130 uV OFFSET-MAX, 0.65 MHz BAND WIDTH, CDIP8, CERDIP-8, Operational Amplifier
LT1114CJ Linear Technology IC QUAD OP-AMP, 130 uV OFFSET-MAX, 0.65 MHz BAND WIDTH, CDIP14, CERDIP-14, Operational Amplifier
LT1097CN8#TRPBF Linear Technology IC OP-AMP, 130 uV OFFSET-MAX, 0.7 MHz BAND WIDTH, PDIP8, 0.300 INCH, LEAD FREE, PLASTIC, DIP-8, Operational Amplifier
XDS510 Texas Instruments XDS510 Class Emulators

ul 506 class 130 Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
en 50022

Abstract: iec 61558 VDE 0570 VA-310 TS-35 USTE 250 transformer 208 V 50 Hz 1440VA uste 100
Text: Teil 2-2; 2-4; 2-6, UL 506 *Kombifußplatte für Schraub- und Tragschienenmontage nach DIN 50022 , ; 2-6, DIN EN 61558-2-2: 2-4; 2-6, VDE 0570 Part 2-2; 2-4; 2-6, UL 506 *Dual purpose foot plate for , °C 40 °C 40 °C 40 °C 40 °C 40 °C 40 °C 40 °C VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 , cooling 40 °C 40 °C 40 °C 40 °C 40 °C VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130


Original
PDF 100/2x115 800/2x115 1000/2x115 1600/2x115 2500/2x115 3200/2x115 en 50022 iec 61558 VDE 0570 VA-310 TS-35 USTE 250 transformer 208 V 50 Hz 1440VA uste 100
Not Available

Abstract: No abstract text available
Text: manufactured to comply with UL Standard 506 ,1561,1012, or 1062 and carry the applicable UL Listing Label , 506 XPTQ E 79947V1 50B8 B 3223 130 .0 5 0 -5 .0 N /A Air Cooled Ventilated & , Certified LOAD VOLTAGE How to overcurrent protect (OCP) 600 volt class transform ers and associated , Phase KVA Three Phase G e n e ra l P u rp o s e a n d B u c k -B o o s t 506 XPTQ E 79 9 4 7 V 1 50B8 B 3223 130 .0 5 0 -.1 5 0 N /A General Purpose Buck-Boost & DIT


OCR Scan
PDF ST-201992 R1978)
Transformer Ip 100

Abstract: PHI05 Class 130 Class 130(B) transformer TS-35 175 va transformer 4500v
Text: 61558-2-2; 2-4; 2-6, DIN EN 61558-2-2; 2-4; 2-6, VDE 0570 Teil 2-2; 2-4; 2-6, UL 506 Primärseitig ±15 V , 61558-2-2; 2-4; 2-6, VDE 0570 part 2-2; 2-4; 2-6, UL 506 ±15 V primary tappings for the adaption of the , °C 40 °C 40 °C 40 °C 40 °C 40 °C 40 °C 40 °C VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 , 40 °C 40 °C VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130


Original
PDF
Class 130(B) transformer

Abstract: transformer 50 Hz VDE 0570 transformer 230 V 50 Hz ste 2500 Class 130 VA-310 A 7800 x0,8 TS-35
Text: . Trenntransformator nach IEC 61558-2-2; 2-4; 2 6, DIN EN 61558-2-2; 2-4; 2-6, VDE 0570 Teil 2-2; 2-4; 2-6, UL 506 , 61558-2-2, DIN EN 61558-2-2; 2-4; 2-6, VDE 0570 part 2-2; 2-4; 2-6, UL 506 ±5 % primary tappings for the , 40 °C VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 3600 V, 50 Hz 4500 V, 50 Hz 4500 V, 50 Hz 3600 V , °C 40 °C 40 °C 40 °C 40 °C 40 °C 40 °C 40 °C VDE=B, UL=130 VDE=B, UL=130


Original
PDF
2002 - Not Available

Abstract: No abstract text available
Text: n UL 506 , File E73539 UL Recognized Class B UL 1446, File E80130 CSA 22.2#66, File LR68051-2 n TUV, EN61558 Figure A VA 25 43 80 130 175 VA 25 43 80 130 175 Figure B WT , 1.625 FIG A A B B B UL Class B, CSA, and TUV certified Part No. Chassis Mount A41 , -43-230A43 A41-80-230A44 A41-130-230A45 A41-175-230A46 (Size) VA 25 43 80 130 175 25 43 80 130 175 25 43 80 130 175 25 43 80 130 175 25 43 80 130 175 25 43 80 130 175 25 43


Original
PDF E73539
2012 - DST4-36B26

Abstract: No abstract text available
Text: , 506 , File E73539 n UL Recognized Class B n UL 1446, File E179499 n CSA 22.2#66, File LR68051-2 n , -10B33 LP230-25B21 LP230-50B22 AGENCY APPROVALS n UL , 506 , File E73539 n UL 1446, File E179499 n CSA , Transformers Low Frequency, Open-Style Laminated, Chassis-Tran Series AGENCY APPROVALS n UL , 506 , File E73539 n UL 1446, File E179499 n CSA 22.2#66, File LR68051-2 n UL Recognized Class B Channel frame , Laminated, International High Power Series AGENCY APPROVALS n UL , 506 , File E73539 n UL Recognized


Original
PDF LT2012 DST4-36B26
2004 - A0100

Abstract: No abstract text available
Text: Drop Operating Temperature Range Ambient Temperature Range EN132400 300 VRMS 130 VRMS 3000 VDC for 2s 5000 volts <10 millivolts -25 to 100C -25 to 60C 65 or 100 Amps 100 to 600 nF UL 1283 250 VRMS 130 VRMS , assembly and crimping up to 80% and installation. The products meet all applicable requirements of UL and EN. Patents Pending PRODUCT SPECIFICATIONS Electrical Current Rating UL 1977, UL1283 , Force Contact Retention UL 1977 Materials Insulator & Cable Clamp Contacts & Ground Plate Capacitor PBT


Original
PDF fC065-PC/6AWG AFC065-PC/M25 AFC065-PC/M16 AFC100-PC/2AWG AFC100-PC/4AWG AFC100-PC/M35 AFC100-PC/M25 AFC065-PE/020 AFC065-PE/030 AFC065-PE/050 A0100
2009 - BV 048-5052.0 H

Abstract: EI type bobbin ee20 transformer bobbin WT 5072 bv 038-5193.0 era bv 125-0039.0 bv 039-5305,0 l transformer UI30 030-7274.0 EE20/10 bobbin
Text: / 8.88 230 2. UL 1585, File E175197 6 / 13.30 230 1. UL 506 , File E113449 Secondary (V , . UL 506 , File E113449 Secondary (V / mA) 230 AGENCY APPROVALS Pin Ø 0,6 mm (Pin DIA , TRANSFORMERS Type EE20 / 10 - 0.50VA Primary (V) 1. UL 506 , File E113449 Secondary (V / mA) 230 , . UL 1585, File E175197 6 / 83 230 1. UL 506 , File E113449 Secondary (V / mA) 230 , Class 2/3 V DE Part Number 230 3. EN61558 8.50 9 / 111 230 2. UL 1585, File


Original
PDF LT2007 08VA-0 BV 048-5052.0 H EI type bobbin ee20 transformer bobbin WT 5072 bv 038-5193.0 era bv 125-0039.0 bv 039-5305,0 l transformer UI30 030-7274.0 EE20/10 bobbin
2014 - ABB GB14048. 3

Abstract: No abstract text available
Text: material for highest fire protection classification UL 94 V-0 –– Tool-free mounting on DIN rail as , time tan. term acc. to IEC/EN 61557-8 R2 only active with 2 x 1 c/o configuration Approvals A UL , category AC rating ( UL 508) 2 x 1 or 1 x 2 c/o (SPDT) contacts configurable open- or closed-circuit , Ambient temperature ranges Climatic class Damp heat, cyclic Vibration, sinusoidal Shock, half-sine , , 95 % RH Class 2 Class 2 Data sheet | Insulation monitoring relays CM-IWN.4/5/6 - 13 Isolation


Original
PDF
2013 - Not Available

Abstract: No abstract text available
Text: 50/60 Hz) • Dual Secondaries - Series or parallel • Leakage - Current meets UL 60601-1, IEC/EN 60601-1 • Insulation - Class F (155 º C) • Flammability Rating - Bobbin and shroud material meet UL 94-V0 Agency Certifications • UL 1446 E66312 • Recognized to UL 506 / UL 5085-2, CSA 22.2, No , -80-10L 80 10 VCT @ 8.0A 5.0V@16.0A 18AWG A41-130-10L 130 10 VCT @ 13.0A 5.0V@26.0A , -80-12L 80 12.6 VCT @ 6.3A 6.3V@12.6A 18AWG A41-130-12L 130 12.6 VCT @ 10.3A 6.3V@20.6A


Original
PDF 94-V0 E66312 E63829 VDE30L 18AWG A41-130-230L A41-175-230L UL1015, 18AWG
2002 - transformer 3A

Abstract: 2x12VAC 800VA en 61558-2-6 transformer 230vac 12Vac protection circuit schematic sim UL-506 Sim circuit transformer circuit breaker
Text: ) Construction Weight Description VDE 0570, EN 61558-1 EN 61558-2-6 ; UL 506 CSA 22.2 Input: 230Vac Output: 2 x 12Vac Output: 2 x 33,3A 50-60Hz. 800VA IP 20 II B ( 130 °C) Max. 40 , SIM 800 Revised : 03.2002 Product Type No.: Safety Isolating Transformer SIM 800 Schematic Plan Technical Details Safety Standards Designated Voltage Designated Voltage Designated Current Designated Frequency Output Power Protection Index Protection Class Insulation Class Ambient


Original
PDF 230Vac 12Vac 50-60Hz. 800VA transformer 3A 2x12VAC 800VA en 61558-2-6 transformer 230vac 12Vac protection circuit schematic sim UL-506 Sim circuit transformer circuit breaker
8B123

Abstract: MIL-PRF-83531 dmpcy-12b41 DMPC-Y-12B41 DMT-8-12A05 12b41 24A15, regulator 14A-10-28B33 dmt-7 15A02 mb
Text: APPROVALS UL , 506 , File E73539 UL 1446, File E80130 CSA 22.2#66, File LR68051-2 UL Recognized Class , 18V @ 0.14A 18V @ 0.28A 18V @ 0.56A 18V @ 1.12A 18V @ 1.64A 18V @ 3.12A UL 506 , File E73539 UL Recognized Class B UL 1446, File E80130 CSA 22.2#66, File LR68051-2 TUV, EN61558 VA , Secondaries can be series or parallel connected UL Class B, CSA, and TUV certified Part No. Chassis Mount , -25-230A42 A41-43-230A43 A41-80-230A44 A41-130-230A45 A41-175-230A46 AGENCY APPROVALS UL 506


Original
PDF
VDE 0551 EN 60 742

Abstract: transformer 230v to 60v block VDE 0551 EN 60 742 vde 0551 400v 250VA ul 506 class 130
Text: . : VDE 0551/EN 60 742; UL 506 ;CSA 22.2 Test voltage. : PRI - SEC 4000 V , . : open design, impregnated Protection class . : prepared for protection class I Protection index . : IP 00 Max ambient temperature . : + 40 °C Insulation class of the Insulation system. : E ( UL class 105 ) Input voltage. : 230V/400V , E 48.5 63.5 73 83 90 130 F(typ.) 44 53 53 61 56 77 1,30 2,20 2,90 4,65 8,0 13


Original
PDF to250VA) 0551/EN VDE 0551 EN 60 742 transformer 230v to 60v block VDE 0551 EN 60 742 vde 0551 400v 250VA ul 506 class 130
2002 - 500va transformer

Abstract: 500VA UL-506 217A transformer class 2 UL506 Class b 130C transformer transformer 230vac
Text: ) Construction Weight Description VDE 0570, EN 61558-1 EN 61558-2-4 ; UL 506 CSA 22.2 Input: 230Vac Output: 2 x 115Vac Output: 2 x 2,17A 50-60Hz. 500VA IP 20 II B ( 130 °C) Max. 40 , TIM 500 Revised : 03.2002 Product Type No.: Isolating Transformer TIM 500 Schematic Plan Technical Details Safety Standards Designated Voltage Designated Voltage Designated Current Designated Frequency Output Power Protection Index Protection Class Insulation Class Ambient


Original
PDF 230Vac 115Vac 50-60Hz. 500VA 5x20mm 500va transformer 500VA UL-506 217A transformer class 2 UL506 Class b 130C transformer transformer 230vac
2002 - Fuse 220V 5A

Abstract: Class 10 thermal overload transformer 12 220v 230v transformer auto transformer Class b 130C transformer
Text: Description VDE 0570, EN 61558-1 EN 61558-2-13 ; UL 506 CSA 22.2 Input: 115V/220V/230V/240Vac Output: 115V/220V/230V/240Vac Output: 10A (5A at Ue 115V) 50-60Hz. IP 20 II B ( 130 °C) Max. 40 , AIM 10/5 Revised : 03.2002 Product Type No. Auto Transformer AIM 10/5 Schematic Plan Technical Details Safety Standards Designated Voltage Designated Voltage Designated Current Designated Frequency Protection Index Protection Class Insulation Class Ambient Temperature


Original
PDF 15V/220V/230V/240Vac 50-60Hz. 5x20mm Fuse 220V 5A Class 10 thermal overload transformer 12 220v 230v transformer auto transformer Class b 130C transformer
2004 - 500va transformer

Abstract: 500VA transformer 230vac
Text: ) Construction Weight Description VDE 0570, EN 61558-1 EN 61558-2-4 ; UL 506 CSA 22.2 Input: 230Vac Output: 2 x 115Vac Output: 2 x 2,17A 50-60Hz. 500VA IP 20 I B ( 130 °C) Max. 40 , TIM 500 Revised : 02.2004 Product Type No.: Isolating Transformer TIM 500 Schematic Plan Technical Details Safety Standards Designated Voltage Designated Voltage Designated Current Designated Frequency Output Power Protection Index Protection Class Insulation Class Ambient


Original
PDF 230Vac 115Vac 50-60Hz. 500VA 5x20mm 500va transformer 500VA transformer 230vac
Class 130(B) transformer

Abstract: Class 130 transformer 50 Hz VDE 0570 transformer 230 V 50 Hz 70 V clamp current transformer 61558 630VA TS-35 ul 506 class 130
Text: nach IEC 61558-2-2; 2-4; 2-6, DIN EN 61558-2-2; 2-4; 2-6, VDE 0570 Teil 2-2; 2-4; 2-6, UL 506 , 61558-2-2; 2-4; 2-6, DIN EN 61558-2-2; 2-4; 2-6, VDE 0570 part 2-2; 2-4; 2-6, UL 506 ±15 V primary , 40 °C 40 °C 40 °C 40 °C VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 4500 V, 50 Hz 4500 V, 50 Hz , Selbstkühlung self cooling 40 °C 40 °C 40 °C 40 °C 40 °C 40 °C 40 °C 40 °C VDE=B, UL=130


Original
PDF 6155LAMP, Class 130(B) transformer Class 130 transformer 50 Hz VDE 0570 transformer 230 V 50 Hz 70 V clamp current transformer 61558 630VA TS-35 ul 506 class 130
2002 - 800VA

Abstract: Class b 130C transformer transformer parallel UL506 transformer 230vac
Text: ) Construction Weight Description VDE 0570, EN 61558-1 EN 61558-2-4 ; UL 506 CSA 22.2 Input: 230Vac Output: 2 x 115Vac Output: 2 x 3,47A 50-60Hz. 800VA IP 20 II B ( 130 °C) Max. 40 , TIM 800 Revised : 03.2002 Product Type No.: Isolating Transformer TIM 800 Schematic Plan Technical Details Safety Standards Designated Voltage Designated Voltage Designated Current Designated Frequency Output Power Protection Index Protection Class Insulation Class Ambient


Original
PDF 230Vac 115Vac 50-60Hz. 800VA 5x20mm 800VA Class b 130C transformer transformer parallel UL506 transformer 230vac
2002 - 1000va transformer

Abstract: power transformer class B transformer 230vac ul 506 class 130 UL506 61558-1 UL-506 en 61558-2-4 TIM 1000 Isolating Transformer 130
Text: ) Construction Weight Description VDE 0570, EN 61558-1 EN 61558-2-4 ; UL 506 CSA 22.2 Input: 230Vac Output: 2 x 115Vac Output: 2 x 4,35A 50-60Hz. 1000VA IP 20 II B ( 130 °C) Max. 40 , TIM 1000 Revised : 03.2002 Product Type No.: Isolating Transformer TIM 1000 Schematic Plan Technical Details Safety Standards Designated Voltage Designated Voltage Designated Current Designated Frequency Output Power Protection Index Protection Class Insulation Class Ambient


Original
PDF 230Vac 115Vac 50-60Hz. 1000VA 5x20mm 1000va transformer power transformer class B transformer 230vac ul 506 class 130 UL506 61558-1 UL-506 en 61558-2-4 TIM 1000 Isolating Transformer 130
2002 - auto transformer

Abstract: ul 506 class 130 220V 61558-1 230v transformer UL-506 Class b 130C transformer Class B transformer
Text: Description VDE 0570, EN 61558-1 EN 61558-2-13 ; UL 506 CSA 22.2 Input: 115V/220V/230V/240Vac Output: 115V/220V/230V/240Vac Output: 16A (8A at Ue 115V) 50-60Hz. IP 20 II B ( 130 °C) Max. 40 , AIM 16/8 Revised : 03.2002 Product Type No. Auto Transformer AIM 16/8 Schematic Plan Technical Details Safety Standards Designated Voltage Designated Voltage Designated Current Designated Frequency Protection Index Protection Class Insulation Class Ambient Temperature


Original
PDF 15V/220V/230V/240Vac 50-60Hz. 5x20mm auto transformer ul 506 class 130 220V 61558-1 230v transformer UL-506 Class b 130C transformer Class B transformer
2002 - transformer 400V

Abstract: 1600VA 115VAC1 61558-1 DIN EN 61558-1
Text: (Output) Weight Marking: VDE 0570, EN 61558-1 EN 61558-2-4 ; EN 61558-2-2 UL 506 ; CSA 22.2 Input , Prepared for class I equipment B ( 130 °C) Max. 40°C Non-short-Circuit-Proof 4500V 4000V 2500V Cage , Designated Frequency Output Power Protection Index Protection Class Insulation Class Ambient Temperature


Original
PDF 192/82/B2 30V/400V /-15Vac 115Vac 50-60Hz. 1600VA transformer 400V 1600VA 115VAC1 61558-1 DIN EN 61558-1
Class 130B transformer

Abstract: 4600 transformer tyco transformer manufacturing process flow chart Class 130(B) transformer 4000-05E07K Part Numbering System transformer Tyco transformer 10va 4000-78J15BB 9100 series relay TRANSFORMER 20VA 24v
Text: Class : UL Class B ( 130 °C). Weight: 5VA ­ 10.56 oz. (300 g); 10VA ­ 10.88 oz. (308 g); 20VA ­ 14.24 oz , Frequency: 50/60 Hz. Insulation Class : UL Class B ( 130 °C). Weight: 10VA ­ 10.9 oz. (308 g); 20VA ­ 14.1 oz , ) total length with 1/2" (12.7 mm) strip. Frequency: 50/60 Hz. Insulation Class : UL Class B ( 130 °C). , ) strip. Frequency: 50/60 Hz. Insulation Class : UL Class B ( 130 °C). Weight: 40VA ­ 24.3 oz. (600 g , Frequency: 50/60 Hz. Insulation Class : UL Class B ( 130 °C). Weight: 40VA ­ 22.4 oz. (636 g); 50VA ­ 35.2 oz


Original
PDF UL1585 Class 130B transformer 4600 transformer tyco transformer manufacturing process flow chart Class 130(B) transformer 4000-05E07K Part Numbering System transformer Tyco transformer 10va 4000-78J15BB 9100 series relay TRANSFORMER 20VA 24v
2002 - sim 500

Abstract: 500va transformer 500VA power transformer construction BREAKER 25A schematic sim EN 61558-2-6 power transformer class B 506 k VDE 0570 25a
Text: ) Construction Weight Description VDE 0570, EN 61558-1 EN 61558-2-6 ; UL 506 CSA 22.2 Input: 230Vac Output: 2 x 12Vac Output: 2 x 20,8A 50-60Hz. 500VA IP 20 II B ( 130 °C) Max. 40 , SIM 500 Revised : 03.2002 Product Type No.: Safety Isolating Transformer SIM 500 Schematic Plan Technical Details Safety Standards Designated Voltage Designated Voltage Designated Current Designated Frequency Output Power Protection Index Protection Class Insulation Class Ambient


Original
PDF 230Vac 12Vac 50-60Hz. 500VA sim 500 500va transformer 500VA power transformer construction BREAKER 25A schematic sim EN 61558-2-6 power transformer class B 506 k VDE 0570 25a
2002 - 61558-1

Abstract: power transformer class B
Text: (Output) Weight Marking: VDE 0570, EN 61558-1 EN 61558-2-4 ; EN 61558-2-2 UL 506 ; CSA 22.2 Input , Prepared for class I equipment B ( 130 °C) Max. 40°C Non-short-Circuit-Proof 4500V 4000V 2500V Cage , Designated Frequency Output Power Protection Index Protection Class Insulation Class Ambient Temperature


Original
PDF 192/110/B2 30V/400V /-15Vac 115Vac 50-60Hz. 2500VA 61558-1 power transformer class B
2002 - iec 61558-1

Abstract: No abstract text available
Text: (Output) Weight Marking: VDE 0570, EN 61558-1 EN 61558-2-4 ; EN 61558-2-2 UL 506 ; CSA 22.2 Input , Prepared for class I equipment B ( 130 °C) Max. 40°C Non-short-Circuit-Proof 4500V 4000V 2500V Cage , Designated Frequency Output Power Protection Index Protection Class Insulation Class Ambient Temperature


Original
PDF 192/104/B2 30V/400V /-15Vac 115Vac 50-60Hz. 2000VA iec 61558-1
Supplyframe Tracking Pixel