The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
EL5171ISZ-T13 Intersil Corporation 250MHz Differential Twisted-Pair Drivers; SOIC8; Temp Range: -40° to 85°C
EL5174ISZ-T13 Intersil Corporation 550MHz Differential Twisted-Pair Drivers; SOIC8; Temp Range: -40° to 85°C
EL5178ISZ-T13 Intersil Corporation 700MHz Differential Twisted-Pair Drivers; MSOP8, SOIC8; Temp Range: -40° to 85°C
EL5373IUZ-T13 Intersil Corporation 450MHz Differential Twisted-Pair Drivers; QSOP24; Temp Range: -40° to 85°C
EL5170IYZ Intersil Corporation 100MHz Differential Twisted-Pair Drivers; MSOP8, SOIC8; Temp Range: -40° to 85°C
EL5173IYZ Intersil Corporation 450MHz Differential Twisted-Pair Drivers; MSOP8, SOIC8; Temp Range: -40° to 85°C

twisted pair cable Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
Not Available

Abstract: No abstract text available
Text: OverSingle Twisted Pair Cable NTSC or PAL Video Two Unbalanced -10 dBV Phono Jack Line Outputs Video From Pair A; L (Left) From Pair B; R (Right) From Pair C Remote Powering through Twisted Pair Cable â , jack. A concealed GAIN control is provided to recover any video level loss over the twisted pair cable , in the cable . The audio signals received from pairs B and C of the twisted pair cable are buffered , terminate the video cable pair , therefore additional receivers may not be connected to the same twisted


Original
PDF 150mA
Not Available

Abstract: No abstract text available
Text: Power Pair Pass-Through on RJ45 Jacks • Remote Powering through Twisted Pair Cable • Fused Local , deep to accommodate RJ45 jacks and plugs, therefore the EM- products connect to the twisted pair cable , remote modules. The -TPS1A may be remotely powered through the twisted pair cable from any other module, signal distributor or RDL power inserter connected to the same twisted pair cable . Module power is , protection circuit. STEP 4: Connect the twisted pair cable (s) and fasten the module in its mounting box


Original
PDF
Not Available

Abstract: No abstract text available
Text: €¢ • • • • • • • • • Video and Stereo Audio Over Single Twisted Pair Cable , front-panel GAIN control is provided to recover any level loss over the twisted pair cable . An EQ control , audio signals received from pairs B and C of the twisted pair cable are buffered to drive the , powered through the twisted pair cable from any other module, signal distributor or RDL power inserter connected to the same twisted pair cable . Module power is indicated by a front-panel LED. RDL FORMAT-C


Original
PDF
Not Available

Abstract: No abstract text available
Text: Pass-Through on RJ45s Remote Powering through Twisted Pair Cable Fused Local Power Feeds all Connected , and plugs, therefore the EM- products connect to the twisted pair cable through a detachable terminal , twisted pair receivers allow connection of up to 10 receiver outputs for each cable pair . The possibility , -TPR2A may be remotely powered through the twisted pair cable from any other module, signal distributor or RDL power inserter connected to the same twisted pair cable . Module power is indicated by a


Original
PDF RJ45s 155mA
2001 - e1 cable

Abstract: LXT384 characteristics of twisted pair cable cable e1 16 x E1 G.703 coaxial d8 AN119 TWP cable LXT380 LXT381
Text: . 9 Twisted Pair Cable Output .11 LXT380/1 Rx Return Loss, Twisted Pair Cable , .12 LXT380/1 Tx Return Loss, Twisted Pair Cable .13 LXT380 , .17 E1 Twisted Pair Cable Output , .19 LXT384 Rx Return Loss, E1 Twisted Pair Cable .20 LXT384 Rx


Original
PDF LXT380/1/4/6/8 AN119. LXT38x e1 cable LXT384 characteristics of twisted pair cable cable e1 16 x E1 G.703 coaxial d8 AN119 TWP cable LXT380 LXT381
D link Cat 6 stp

Abstract: SP-2840 EN50167 Leoni M100M leoni stp EN50169 pimf twisted pair cables D link Cat 6 stp cable
Text: -1 AT-F-VH-5 AT-F2-V-5 Type/Coating Unit UTP Twisted Pair Cable , CAT 5 Shielding : 'Types: i Coating : ! , m 500 m FTP Twisted Pair Cable , CAT 5 Shielding T ypes: C oating: Unit : Common shielding with , m reel o r 500 m reel FTP DUPLEX Twisted Pair Cable , CAT 5 Shielding : Types: Coating : U n it , SFTP Twisted Pair Cable , CAT 5 Shielding : Common shielding with Al-laminated foil and CU-mesh. SFTP , AT-P3-P-1 AT-P3-P-5 Patch, PVC Patch, PVC 100 m 500 m S/S TP (PIMF) 300 MHz Twisted Pair Cable


OCR Scan
PDF EN50173 EN55022 D link Cat 6 stp SP-2840 EN50167 Leoni M100M leoni stp EN50169 pimf twisted pair cables D link Cat 6 stp cable
Not Available

Abstract: No abstract text available
Text: Twisted Pair Cable NTSC or PAL Video Two Unbalanced -10 dBV Phono Jack Audio Inputs Video Feeds Pair A; L (Left) Feeds Pair B; R (Right) Feeds Pair C Remote Powering through Twisted Pair Cable • â , the twisted pair cable through a detachable terminal block. APPLICATION: The -TPS3C modules feature , twisted pair cable . Module power is indicated by a front-panel LED. RDL FORMAT-C provides quality , the power input terminals if this module is not being powered through the twisted pair cable from


Original
PDF
2001 - LXT380

Abstract: No abstract text available
Text: . 9 Twisted Pair cable Output , .12 LXT380/1 LIU Rx Return Loss, Twisted Pair Cable , .13 LXT380/1 LIU Tx Return Loss, Twisted Pair Cable , .15 E1 Twisted Pair Cable Output , .18 LXT384 LIU Rx Return Loss, E1 Twisted Pair Cable


Original
PDF LXT380/1/4/6/8 LXT38x LXT380
Not Available

Abstract: No abstract text available
Text: the twisted pair cable through a detachable terminal block. APPLICATION: The -TPR1A modules feature , cable from any other module, signal distributor or RDL power inserter connected to the same twisted pair , the twisted pair cable from another module, or if this module is located an excessive distance from , the desired pair A, B or C of the Format-A cable . STEP 3: Connect the twisted pair cable coming from Format-A senders or distributors. STEP 4: Connect the twisted pair cable feeding additional Format-A


Original
PDF RJ45s 155mA
Not Available

Abstract: No abstract text available
Text: Outputs XLR From Pair A; L FromPair B; R From Pair C Remote Powering through Twisted Pair Cable â , . The audio signals received from pairs B and C of the twisted pair cable are buffered to drive the RCA , three cable pairs, additional receivers may be connected to the same twisted pair feed. The bridging , twisted pair cable from any other module, signal distributor or RDL power inserter connected to the same twisted pair cable . Module power is indicated by a front-panel LED. RDL FORMAT-A features superior audio


Original
PDF 155mA
2001 - 16 x E1 G.703

Abstract: dpdt mechanical relays 3v EN-6100-4-5 analog isolated Signal Transformer twisted pair LXT388 LXT386 LXT384 LXT381 LXT380 LC03-6
Text: . 10 Twisted Pair cable Output , . 12 LXT380/1 Rx Return Loss, Twisted Pair Cable , 13 LXT380/1 Tx Return Loss, Twisted Pair Cable . , . 14 E1 Twisted Pair Cable Output , . 17 LXT384 Rx Return Loss, E1 Twisted Pair Cable .


Original
PDF LXT380/1/4/6/8 LXT38x 16 x E1 G.703 dpdt mechanical relays 3v EN-6100-4-5 analog isolated Signal Transformer twisted pair LXT388 LXT386 LXT384 LXT381 LXT380 LC03-6
Not Available

Abstract: No abstract text available
Text: Pass-Through on RJ45 Jacks Remote Powering through Twisted Pair Cable Fused Local Power Feeds all Connected , and plugs, therefore the EM- products connect to the twisted pair cable through a detachable terminal , remote modules. The -TPS2A may be remotely powered through the twisted pair cable from any other module, signal distributor or RDL power inserter connected to the same twisted pair cable . Module power is , the power input terminals if this module is not being powered through the twisted pair cable from


Original
PDF
Not Available

Abstract: No abstract text available
Text: TX-TPR1A may be remotely powered through the twisted pair cable from any other module, signal distributor or RDL power inserter connected to the same twisted pair cable . Module power is indicated by a , ) if this module is not being powered through the twisted pair cable from another module, or if this , equipment input. STEP 4: Connect the INPUT twisted pair cable coming from Format-A senders or distributors. STEP 5: Connect the LOOP OUT twisted pair cable feeding additional Format-A receiver(s), if any, and


Original
PDF RJ45s
em 60 microphone

Abstract: No abstract text available
Text: MIC Feeds Pair A; L Feeds Pair B; R Feeds Pair C Remote Powering through Twisted Pair Cable • â , deep to accommodate RJ45 jacks and plugs, therefore the EM- products connect to the twisted pair cable , through the twisted pair cable from any other module, signal distributor or RDL power inserter connected to the same twisted pair cable . Module power is indicated by a front-panel LED. RDL FORMAT-A , module is not being powered through the twisted pair cable from another module, or if this module is


Original
PDF
1997 - 1117 3.3

Abstract: 1117 A 33 1117 33 1117 c 3337 LVDS twinax twisted pair cable
Text: , 69 C cable ground, see ground return paths cable shielding, 39, 51-54 cables, 1, 3, 5-6, 11, 13-17, 33-34, 42-43, 51-58, 67-68, 70-71 CAT3 cable , see twisted pair cable CAT5 cable , see twisted pair cable Channel Link latency, 22 Channel Link, 6, 14-17, 22, 65, 78 clock vs. data rate, note on page 21 , measurements twinax, 52 twisted pair cable , 1, 3, 5, 13-17, 52, 54-58, 67-68, 70-71 TWP, see twisted pair cable U unused pins, 4, 30, 43-45, 52-53, 68 UTP, see twisted pair cable 84 National


Original
PDF ANSI/TIA/EIA-644 RS-422, 1117 3.3 1117 A 33 1117 33 1117 c 3337 LVDS twinax twisted pair cable
Not Available

Abstract: No abstract text available
Text: the twisted pair cable . No other sending modules may be connected on the same cable with this module , OUTPUT RJ45 jack. The TX-TPS3A may be remotely powered through the twisted pair cable from any other module, signal distributor or RDL power inserter connected to the same twisted pair cable . Module power , Vdc to the power input terminals if this module is not being powered through the twisted pair cable , circuit. STEP 3: Connect the twisted pair cable (s) and mount the module. RJ45 Standard wiring (1) (2


Original
PDF 135mA
Not Available

Abstract: No abstract text available
Text: through Twisted Pair Cable Daisy-Chain with Single-Pair Sender Studio-Quality Precision Active Balanced , remaining active. The -TPS8A is remotely powered through the twisted pair cable from any other module, signal distributor or RDL power inserter connected to the same twisted pair cable . There are no , FORMAT A Twisted Pair Cable to Additional -TPS8A Format-A Senders or a Format-A Receiver. INPUT FORMAT A TP CABLE D SERIES - TPS8A D SERIES - TPS8A Connect FORMAT A Twisted Pair Cable to the


Original
PDF
Not Available

Abstract: No abstract text available
Text: €¢ • • • • • • • • Video and Stereo Audio Over Single Twisted Pair Cable Two , connected remote modules. The TX-TPS3C may be remotely powered through the twisted pair cable from any other module, signal distributor or RDL power inserter connected to the same twisted pair cable . Module , through the twisted pair cable from another module, or if this module is located an excessive distance , the internal protection circuit. STEP 4: Connect the twisted pair cable and mount the module. RJ45


Original
PDF 135mA
NCR92C02A

Abstract: 35TH NCR asic mau aui NE521 P802 NCR SCSI cxb 100 transformer
Text: INTERFACE Figure 4 shows how the NCR92C02A interfaces to the twisted pair cable through six signals. Four , cable . A typical twisted pair cable attenuates a 10 MHz signal more than a 5 MHz signal. Equalization of , pole sections and must have a pass-band impedance that will properly terminate the twisted pair cable , twisted pair cable . These transformers isolate the MAU from voltages on the cable . Typically, 1:1 , on the twisted pair cable , and low during a negative signal. 6 Communication Products NCR92C02A


OCR Scan
PDF NCR92C02A 10BASE-T T01901N NCR92C02A 35TH NCR asic mau aui NE521 P802 NCR SCSI cxb 100 transformer
1998 - 56k 1kv

Abstract: HYC9068 arcnet transceiver HYC9058
Text: HITTM FEATURES · · · · · ARCNET on Twisted Pair or Coaxial Cable Drives Shielded and Unshielded Twisted Pair Cable or Coaxial Cable Compatible with Existing ARCNET Installations 2.5 Mbps operation Pin , interfaces an ARCNET Local Area Network controller to one twisted pair or coaxial cable . The HIT interfaces , . Connect this signal to Twisted Pair Connector pin 3 or the shield of the coaxial cable . Output. Connect this signal to Twisted Pair Connector pin 2 or the center of the coaxial cable . Input. This signal is


Original
PDF HYC9088A HYC9068 HYC9088 56k 1kv arcnet transceiver HYC9058
2006 - HYC9088A

Abstract: diode rg62 018 HYC9088 HYC9088AR HYC9088AS RG62 24 transformer
Text: · · · · ARCNET on Twisted Pair or Coaxial Cable Drives Shielded and Unshielded Twisted Pair , signal to Twisted Pair Connector pin 3 or the shield of the coaxial cable . 12 Phase-A/ Center , used to interconnect ARCNET nodes. The two far ends of the twisted pair cable must be terminated using , a resistor which matches the characteristic impedence of the Twisted Pair Cable . For the cable types specified in Table 1, the maximum length of the twisted pair cable recommended is 400 feet. Small


Original
PDF HYC9088A HYC9088A HYC9088AR HYC9088AS HYC9088AS HYC9088AR diode rg62 018 HYC9088 RG62 24 transformer
2004 - HYC9068

Abstract: HYC9088AS ARCNET driver 24 transformer HYC9088 EMI CABLE COAX HYC9058 HYC9088A HYC9088AR RG62
Text: FEATURES · · · · · ARCNET on Twisted Pair or Coaxial Cable Drives Shielded and Unshielded Twisted , Output. Connect this signal to Twisted Pair Connector pin 3 or the shield of the coaxial cable . 12 , . The two far ends of the twisted pair cable must be terminated using terminating resistors equal to , the Twisted Pair Cable . For the cable types specified in Table 1, the maximum length of the twisted , FEET MAXIMUM TWISTED PAIR CABLE T T 6 FEET MINIMUM 1 2 3 9 10TH CONNECTION


Original
PDF HYC9088A HYC9068 HYC9088 HYC9088A HYC9068 HYC9088AS ARCNET driver 24 transformer EMI CABLE COAX HYC9058 HYC9088AR RG62
2007 - Not Available

Abstract: No abstract text available
Text: „¢ FEATURES • • • • ARCNET on Twisted Pair or Coaxial Cable Drives Shielded and Unshielded Twisted Pair Cable or Coaxial Cable Compatible with Existing ARCNET Installations 2.5 Mbps operation , signal to Twisted Pair Connector pin 3 or the shield of the coaxial cable . 12 Phase-A/ Center , interconnect ARCNET nodes. The two far ends of the twisted pair cable must be terminated using terminating , a resistor which matches the characteristic impedence of the Twisted Pair Cable . For the cable


Original
PDF HYC9088A HYC9088A HYC9088AR HYC9088AS HYC9088AS HYC9088AR
1998 - HYC9088

Abstract: HYC9058 56k 1kv HYC9068 twisted pair cable with parameter ARCNET driver HYC9088A HYC9088AS RG62 24 transformer
Text: HITTM FEATURES · · · · · ARCNET on Twisted Pair or Coaxial Cable Drives Shielded and Unshielded Twisted Pair Cable or Coaxial Cable Compatible with Existing ARCNET Installations 2.5 Mbps , / SHIELD Output. Connect this signal to Twisted Pair Connector pin 3 or the shield of the coaxial cable , characteristic impedance of the cable used to interconnect ARCNET nodes. The two far ends of the twisted pair , transformer-coupled onto the cable and has a minimum voltage APPLICATION INFORMATION Small Twisted Pair Networks


Original
PDF HYC9088A HYC9068 HYC9088 HYC9088A HYC9058 56k 1kv HYC9068 twisted pair cable with parameter ARCNET driver HYC9088AS RG62 24 transformer
2007 - RJ11 pinout

Abstract: HYC9088A HYC9088AS HYC9088 HYC9088AR RG62 24 transformer
Text: · · · · ARCNET on Twisted Pair or Coaxial Cable Drives Shielded and Unshielded Twisted Pair , signal to Twisted Pair Connector pin 3 or the shield of the coaxial cable . 12 Phase-A/ Center , used to interconnect ARCNET nodes. The two far ends of the twisted pair cable must be terminated using , a resistor which matches the characteristic impedence of the Twisted Pair Cable . For the cable types specified in Table 1, the maximum length of the twisted pair cable recommended is 400 feet. Small


Original
PDF HYC9088A HYC9088A HYC9088AR HYC9088AS HYC9088AS HYC9088AR RJ11 pinout HYC9088 RG62 24 transformer
Supplyframe Tracking Pixel