LT1359CS Linear Technology LT1359 - Quad 25MHz, 600V/µs Op Amps; Package: SO; Pins: 16; Temperature Range: 0°C to 70°C
LT1359IS#TRPBF Linear Technology LT1359 - Quad 25MHz, 600V/µs Op Amps; Package: SO; Pins: 16; Temperature Range: -40°C to 85°C
LT1357CS8 Linear Technology LT1357 - 25MHz, 600V/us Op Amp; Package: SO; Pins: 8; Temperature Range: 0°C to 70°C
LT1359CS14#TR Linear Technology LT1359 - Quad 25MHz, 600V/µs Op Amps; Package: SO; Pins: 14; Temperature Range: 0°C to 70°C
LT1359IS14#TR Linear Technology LT1359 - Quad 25MHz, 600V/µs Op Amps; Package: SO; Pins: 14; Temperature Range: -40°C to 85°C
LT1358CS8 Linear Technology LT1358 - Dual 25MHz, 600V/µs Op Amps; Package: SO; Pins: 8; Temperature Range: 0°C to 70°C

triacs bta 100 600v Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
2005 - TRIAC BTA 28

Abstract:
Text: BTA /BTB12 and T12 Series 12A TRIACS TO-220AB Insulated (BTA12) TO-220AB (BTB12) MAIN , + 100 www.kersemi.com BTA /BTB12 and T12 Series ELECTRICAL CHARACTERISTICS (Tj = 25°C, unless , BTB/T12 BTA Tc(°C) 0 25 50 75 100 125 Fig. 3: Relative variation of , 5 to 50 mA DESCRIPTION Available either in through-hole or surface-mount packages, the BTA , versions ( BTA /BTB.W and T12 series) are specially recommended for use on inductive loads, thanks to


Original
PDF BTA/BTB12 O-220AB BTA12) O-220AB BTB12) BW/CW/T1235) BW/CW/T1235 TRIAC BTA 28 TRIAC BTA 16 Triac BTB12 600 B TRIAC BTa 12 600 BW TRIAC BTA 02 Triac BTA 12A 600 V TRIAC BTa 16 600 B TRIAC BTA 16 600 BW TRIAC BTa 24 BTA 600 12 triac
2001 - TRIAC BTa 18 600 BW

Abstract:
Text: insulated Voltage: 600: 600V 700: 700V Current: 20A 2014-6-10 3 www.kersemi.com BTA (B)20 , BTA20 BW/CW BTB20 BW/CW SNUBBERLESS TRIACS TO-220AB FEATURES High commutation: (dI/dt)c > 18A/ms without snubber High surge current: ITSM = 200A VDRM up to 800V BTA Family: Insulating voltage = 2500V(RMS) (UL recognized: E81734) s s s s DESCRIPTION The BTA /BTB20 BW/CW triac , ITSM RMS on-state current (360° conduction angle) Value BTA Tc = 70°C BTB IT(RMS


Original
PDF BTA20 BTB20 O-220AB E81734) BTA/BTB20 TRIAC BTa 18 600 BW TRIAC BTa 20 600 BW TRIAC BTa 18 600 B triac BTA 18 600 triacs bta 100 600v
2002 - bta 24

Abstract:
Text: BTA /BTB06 Series 6A TRIACS MAIN FEATURES: TO-220AB (BTB06) TO-220AB Insulated (BTA06 , DESCRIPTION Suitable for AC switching operations, the BTA / BTB06 series can be used as an ON/OFF function , versions ( BTA / BTB.W) are specially recommended for use on inductive loads, thanks to their high commutation performances. By using an internal ceramic pad, the BTA series provides voltage insulated tab , rise of on-state current IG = 2 x IGT , tr ≤ 100 ns F = 120 Hz Tj = 125°C 50 A/µs


Original
PDF BTA/BTB06 O-220AB BTB06) O-220AB BTA06) BTB06 bta 24
2000 - bta 16 600 D

Abstract:
Text: BTA /BTB08 and T8 Series ® 8A TRIACS SNUBBERLESSTM , LOGIC LEVEL & STANDARD MAIN , BTA Tc(°C) 0 25 50 75 100 125 Fig. 3: Relative variation of thermal impedance , Tj initial=25°C Repetitive Tc= 100 °C Number of cycles 1 10 100 1000 5/10 BTA , A2 DESCRIPTION Available either in through-hole or surface-mount packages, the BTA /BTB08 and T8 , control operation in light dimmers, motor speed controllers,. The snubberless versions ( BTA /BTB.W


Original
PDF BTA/BTB08 bta 16 600 D triac BT 130 BTB108-xxxBW TRIAC BTA 28 triac BTA 32 600 TRIAC BTa 18 600 B TRIAC BTB08 TRIAC BTA 06 400 G BTA08 ST bta 06 400 v
2001 - TRIAC BTA 28

Abstract:
Text: BTA20 BW/CW BTB20 BW/CW ® SNUBBERLESS TRIACS A2 FEATURES High commutation: (dI/dt)c > 18A/ms without snubber High surge current: ITSM = 200A VDRM up to 800V BTA Family: Insulating voltage = 2500V(RMS) (UL recognized: E81734) s s G s A1 s DESCRIPTION The BTA /BTB20 , ) Symbol Parameter ITSM RMS on-state current (360° conduction angle) Value BTA Tc = 70 , Non repetitive surge peak on-state current (Tj initial = 25°C) 100 -40 to +150 -40 to +125


Original
PDF BTA20 BTB20 E81734) BTA/BTB20 O-220AB TRIAC BTA 28 TRIAC BTA 20 600 BW TRIAC BTa 18 600 BW BTA 600 triac TRIAC BTB 16 600 BW TRIAC BTa 18 600 B bta 28 TRIAC BTA 70 triacs bt 125 600v triac 800V 1A
2002 - TRIAC BTA 28

Abstract:
Text: BTA /BTB08 and T8 Series ® 8A TRIACS SNUBBERLESSTM, LOGIC LEVEL & STANDARD MAIN FEATURES , initial=25°C Repetitive Tc= 100 °C Number of cycles 1 10 100 1000 5/10 BTA /BTB08 and , DESCRIPTION Available either in through-hole or surface-mount packages, the BTA /BTB08 and T8 triac series is , in light dimmers, motor speed controllers,. The snubberless versions ( BTA /BTB.W and T8 series , . By using an internal ceramic pad, the BTA series provides voltage insulated tab (rated at 2500V RMS


Original
PDF BTA/BTB08 TRIAC BTA 28 TRIAC BTB08 triac BTA 32 600 TRIAC BTB08 specifications TRIAC BTB08 600 TRIAC BTa 24 TRIAC BTa 18 600 B BTA 600 bta 03 BTA 36
2001 - TRIAC BTA 28

Abstract:
Text: BTA20 BW/CW BTB20 BW/CW ® SNUBBERLESS TRIACS A2 FEATURES High commutation: (dI/dt)c > 18A/ms without snubber High surge current: ITSM = 200A VDRM up to 800V BTA Family: Insulating voltage = 2500V(RMS) (UL recognized: E81734) s s G s A1 s DESCRIPTION The BTA /BTB20 , ) Symbol Parameter ITSM RMS on-state current (360° conduction angle) Value BTA Tc = 70 , Non repetitive surge peak on-state current (Tj initial = 25°C) 100 Storage and operating


Original
PDF BTA20 BTB20 E81734) BTA/BTB20 O-220AB TRIAC BTA 28 BTA 600 triac triac 800V 1A TRIAC BTa 18 600 BW BTA 36 TRIAC BTa 18 600 B TRIAC BTA 70 Triac bt 33 600 bta 28 TRIAC BTA 02
2002 - BTA 24 600 sw

Abstract:
Text: BTA /BTB06 Series ® 6A TRIACS SNUBBERLESSTM, LOGIC LEVEL & STANDARD MAIN FEATURES: A2 , (ms) Number of cycles 1 4/6 10 100 1000 10 0.01 0.10 1.00 10.00 BTA , 100 125 5/6 BTA /BTB06 Series PACKAGE MECHANICAL DATA TO-220AB / TO-220AB Ins. DIMENSIONS , A1 A2 mA DESCRIPTION Suitable for AC switching operations, the BTA / BTB06 series can be , and logic level versions ( BTA / BTB.W) are specially recommended for use on inductive loads, thanks


Original
PDF BTA/BTB06 BTB06 BTA 24 600 sw TRIAC BTa 18 600 BW triacs bta 100 600v BTA 600 bta 06 400 v BTA 18 800 BTA 50 800 TRIAC BTA series bta 12 600v bta 400
2002 - triacs bt 16 600v

Abstract:
Text: BTA /BTB16 and T16 Series ® 16A TRIACS SNUBBERLESSTM , LOGIC LEVEL & STANDARD MAIN , °C + 100 1/7 BTA /BTB16 and T16 Series ELECTRICAL CHARACTERISTICS (Tj = 25°C, unless , BTB/T16 BTA Tc(°C) 0 25 50 75 100 125 Fig. 3: Relative variation of thermal , ) 0 25 50 75 100 125 1E-2 1E-3 1E-2 1E-1 1E+0 1E+1 1E+2 5E+2 BTA , 10.0 100.0 0 Tj (°C) 0 25 50 75 100 125 5/7 BTA /BTB16 and T16 Series


Original
PDF BTA/BTB16 triacs bt 16 600v triac BTA 32 triac BTA 140 triac BTA 32 600 triacs bt 16a 600v TRIAC BTa 18 600 BW TRIAC BTA series circuit triac btb16 BT 130 triac TRIAC BTa 16 600 BW
2001 - triacs bta 100 600v

Abstract:
Text: ® BTA /BTB10 Series 10A TRIACS SNUBBERLESSTM & STANDARD MAIN FEATURES: Symbol IT(RMS , 2 1 0 BTB BTA IT(RMS) (A) 0 1 2 3 4 5 6 7 8 9 10 Tc(°C) 0 25 50 75 100 125 Fig. 3 , Available either in standard or snubberless version, the BTA /BTB10 triac series is suitable for general , inductive loads, thanks to their high commutation performances. By using an internal ceramic pad, the BTA , of on-state current IG = 2 x IGT , tr 100 ns Parameter A1 A2 G A1 A2 G TO-220AB Insulated


Original
PDF BTA/BTB10 triacs bta 100 600v TRIAC BTA series BTA 600 12 triac BTB10-XXXB TRIAC BTa 18 600 BW TRIAC BTa 18 600 B TRIAC BTA 70 bta 12 600v Triac BTB 06 600 A1A2G
2002 - Not Available

Abstract:
Text: BTA /BTB12 and T12 Series ® 12A TRIACS SNUBBERLESS™, LOGIC LEVEL & STANDARD MAIN , + 100 1/7 BTA /BTB12 and T12 Series ELECTRICAL CHARACTERISTICS (Tj = 25°C, unless otherwise , 3 2 1 0 BTB/T12 BTA Tc(°C) 0 25 50 75 100 125 Fig. 3: Relative , 50 75 tp(s) 100 125 1E-2 1E-3 1E-2 1E-1 1E+0 1E+1 1E+2 5E+2 BTA , /µs) 1.0 10.0 100.0 0 Tj (°C) 0 25 50 75 100 125 5/7 BTA /BTB12


Original
PDF BTA/BTB12
2001 - triac BTA 32 600

Abstract:
Text: BTA04 T/D/S/A BTB04 T/D/S/A ® SENSITIVE GATE TRIACS A2 FEATURES Very low IGT = 10mA max Low IH = 15mA max BTA Family: Insulating voltage = 2500V(RMS) (UL recognized: E81734) s s G s A1 DESCRIPTION The BTA /BTB04 T/D/S/A triac family are high performance glass , angle) Value BTA Tc = 90°C BTB IT(RMS) Unit 4 A A Tc = 95°C dI/dt Tstg , lead soldering temperature during 10s at 4.5mm from case °C °C BTA / BTB04Symbol Parameter


Original
PDF BTA04 BTB04 E81734) BTA/BTB04 O-220AB triac BTA 32 600 triac bta 06 400v TRIAC BTA 400 BTA triac bta 06 400 v TRIAC BTA 08 600 D TRIAC BTB 04 TRIAC BTA 6 bta 10 400v TRIAC BTa 08 700
2000 - triacs bt 12 600v

Abstract:
Text: BTA /BTB12 and T12 Series ® 12A TRIACS SNUBBERLESSTM , LOGIC LEVEL & STANDARD MAIN , 125°C 4 A Tj = 125°C 1 W - 40 to + 150 - 40 to + 125 °C + 100 1/7 BTA , : 600V 800: 800V SENSITIVITY: 35: 35mA PACKING MODE: Blank: Tube -TR: Tape & Reel 3/7 BTA , surface-mount packages, the BTA /BTB12 and T12 triac series is suitable for general purpose AC switching. They , controllers,. The snubberless versions ( BTA /BTB.W and T12 series) are specially recommended for use on


Original
PDF BTA/BTB12 triacs bt 12 600v bt 1690 BT 130 triac BT 126 TRIAC BTA12 600V t 935 T1235 BTA12 W80D BTB12
2002 - TRIAC BTA 28

Abstract:
Text: BTA /BTB24, BTA25, BTA26 and T25 Series ® 25A TRIACS SNUBBERLESSTM & STANDARD MAIN , W - 40 to + 150 - 40 to + 125 °C + 100 1/9 BTA /BTB24, BTA25, BTA26 and T25 Series , 4.0 50 Number of cycles 4.5 0 1 10 100 1000 5/9 BTA /BTB24, BTA25, BTA26 , 36 40 0 Tj (°C) 0 25 50 75 100 125 BTA /BTB24, BTA25, BTA26 and T25 , t Value for fusing Critical rate of rise of on-state current IG = 2 x IGT , tr 100 ns PG(AV


Original
PDF BTA/BTB24, BTA25, BTA26 O-220AB BTB24) TRIAC BTA 28 TRIAC BTB T25 ac motor triac bta25 triac bt 151 triac BTA 32 600 triac TOP3 25a 800V triac bt 24 600v triac BT 408 TRIAC BTB 16 600 BW TRIAC BTA 4000
2001 - TRIAC BTa 18 600 BW

Abstract:
Text: BTA /BTB08 and T8 Series ® 8A TRIACS SNUBBERLESSTM, LOGIC LEVEL & STANDARD MAIN FEATURES , °C Number of cycles 1 10 100 1000 5/10 BTA /BTB08 and T8 Series Fig. 6: Non-repetitive , DESCRIPTION Available either in through-hole or surface-mount packages, the BTA /BTB08 and T8 triac series is , in light dimmers, motor speed controllers,. The snubberless versions ( BTA /BTB.W and T8 series , . By using an internal ceramic pad, the BTA series provides voltage insulated tab (rated at 2500V RMS


Original
PDF BTA/BTB08 TRIAC BTa 18 600 BW TRIAC BTB 16 600 BW BT 136 TRIAC triac BT 140 BTB108-xxxBW TRIAC BTA 28 TRIAC BTB08 specifications T810 BTA 600 triac triac BTA 140
2003 - bta 8a 600v

Abstract:
Text: BTA /BTB08 and T8 Series ® 8A TRIACS SNUBBERLESSTM, LOGIC LEVEL & STANDARD MAIN FEATURES , 4 3 2 1 0 BTB/T8 BTA Tc(°C) 0 25 50 75 100 125 Fig. 3: Relative , 100 1000 5/10 BTA /BTB08 and T8 Series Fig. 6: Non-repetitive surge peak on-state current , DESCRIPTION Available either in through-hole or surface-mount packages, the BTA /BTB08 and T8 triac series is , in light dimmers, motor speed controllers,. The snubberless versions ( BTA /BTB.W and T8 series


Original
PDF BTA/BTB08 bta 8a 600v TRIAC BTA 28 TRIAC BTA 20 600 BW triac bt 24 600v TRIAC BTA-SERIES T835 T810 BTB08 triacs bt 25 600v triac BTA 32 600
2002 - TRIAC BTA series

Abstract:
Text: BTA /BTB10 Series ® 10A TRIACS SNUBBERLESSTM & STANDARD MAIN FEATURES: A2 Symbol , 100 1/6 BTA /BTB10 Series ELECTRICAL CHARACTERISTICS (Tj = 25°C, unless otherwise specified) s , BTA Tc(°C) 0 25 Fig. 4: values). 50 On-state 75 100 characteristics 125 , A1 A2 DESCRIPTION Available either in standard or snubberless version, the BTA /BTB10 triac , an internal ceramic pad, the BTA series provides voltage insulated tab (rated at 2500 V RMS


Original
PDF BTA/BTB10 TRIAC BTA series TRIAC BTa 18 600 BW triac BTA 140 TRIAC BTA 02 triac BTA 80 BTA 600 12 triac TRIAC BTA 6 TRIAC BTA 10 TRIAC BTA 70 TRIAC BTa 24
2002 - BTA12

Abstract:
Text: BTA /BTB12 and T12 Series ® 12A TRIACS SNUBBERLESSTM, LOGIC LEVEL & STANDARD MAIN , °C + 100 1/7 BTA /BTB12 and T12 Series ELECTRICAL CHARACTERISTICS (Tj = 25°C, unless , 12 11 10 9 8 7 6 5 4 3 2 1 0 BTB/T12 BTA Tc(°C) 0 25 50 75 100 , ) 0.5 100.0 0.0 0.1 1.0 10.0 100.0 5/7 BTA /BTB12 and T12 Series Fig. 9 , surface-mount packages, the BTA /BTB12 and T12 triac series is suitable for general purpose AC switching. They


Original
PDF BTA/BTB12 BTA12 BTA 136 600 BT 130 triac TRIAC BTA series triac BTA 32 600 bta 12a 600v Triac BTA 12A 600 V TRIAC BTA 28 bta12 triac induction motor control TRIAC BTa 12 600
2004 - TRIAC BTB 12 600 B

Abstract:
Text: 16.600B triac (VDWM = ± 600V ). The 100 resistor R, between the gate and A1 is not absolutely , AN1966 APPLICATION NOTE PROTECT YOUR TRIACS INTRODUCTION In most of their applications, triacs , reality, the di/dt when turning on can, in this case, reach very high values (> 100 A/µs) since only the , + TRANSIL Assembly. Case of a 600V /12A triac protected by a 440V TRANSIL diode (the dotted line , This current flows through the gate 20 Triac avalanche zone 10 ­ 600V ­400V 0 0 10


Original
PDF AN1966 TRIAC BTB 12 600 B application note triac protection transil diode AN1966 3 kw triac TRIAC BTB 16.600b TRIAC BTB 16 TRIAC BTB 04 transil diode 600V triac gate drive circuit
2001 - BT 130 triac

Abstract:
Text: ® BTA /BTB12 and T12 Series 12A TRIACS SNUBBERLESSTM, LOGIC LEVEL & STANDARD MAIN FEATURES , tp(s) 1E+0 1E+1 1E+2 5E+2 4/7 BTA /BTB12 and T12 Series Fig. 4: values). ITM (A) 100 , Tj (°C) 0 25 50 75 100 125 0.0 0.1 1.0 10.0 0 5/7 BTA /BTB12 and T12 Series Fig , DESCRIPTION Available either in through-hole or surface-mount packages, the BTA /BTB12 and T12 triac series is , light dimmers, motor speed controllers,. The snubberless versions ( BTA /BTB.W and T12 series) are


Original
PDF BTA/BTB12 BT 130 triac BT 126 TRIAC triacs bt 12 600v triac BTA 32 600 bt 1690 triac BTA12 triacs bt 12 800v
2001 - TRIAC BTa 18 600 BW

Abstract:
Text: ® BTA /BTB06 Series 6A TRIACS SNUBBERLESSTM, LOGIC LEVEL & STANDARD MAIN FEATURES: Symbol , 125°C IT = 100 mA IG = 1.2 IGT s STANDARD (4 Quadrants) Symbol Test Conditions Quadrant BTA , (RMS) (A) 7 BTB 6 5 4 3 2 1 Tc(°C) BTA 3 4 5 6 0 0 25 50 75 100 , 10 0.01 0.10 1.00 10.00 4/6 BTA /BTB06 Series Fig. 7: Relative variation of gate , DESCRIPTION Suitable for AC switching operations, the BTA / BTB06 series can be used as an ON/OFF function in


Original
PDF BTA/BTB06 BTB06 TRIAC BTa 18 600 BW triacs bta 100 600v bta 06 400 v TRIAC BTa 18 600 B triac bt 24 600v BTB6 AND8005 BTA 50 800 BTA 18 800
2000 - BT 130 triac

Abstract:
Text: BTA /BTB12 and T12 Series ® 12A TRIACS SNUBBERLESSTM, LOGIC LEVEL & STANDARD MAIN , 125°C 4 A Tj = 125°C 1 W - 40 to + 150 - 40 to + 125 °C + 100 1/7 BTA , )c (V/µs) 1.0 10.0 100.0 0 Tj (°C) 0 25 50 75 100 125 5/7 BTA , surface-mount packages, the BTA /BTB12 and T12 triac series is suitable for general purpose AC switching. They , controllers,. The snubberless versions ( BTA /BTB.W and T12 series) are specially recommended for use on


Original
PDF BTA/BTB12 BT 130 triac TRIAC BT 136 BT 126 TRIAC BT 136 TRIAC triacs bt 12 600v T1235 T12-G triacs bt 16 600v bta12 speed control application BTA12 600
2002 - triac BTA 32 600

Abstract:
Text: BTA /BTB24, BTA25, BTA26 and T25 Series ® 25A TRIACS SNUBBERLESSTM & STANDARD MAIN , W - 40 to + 150 - 40 to + 125 °C + 100 1/9 BTA /BTB24, BTA25, BTA26 and T25 Series , 10 100 1000 5/9 BTA /BTB24, BTA25, BTA26 and T25 Series Fig. 6: Non-repetitive surge , °C) I²t Value for fusing Critical rate of rise of on-state current IG = 2 x IGT , tr 100 ns PG(AV , either in through-hole of surface and T25 mount packages, the BTA /BTB24-25-26 triac series is suitable


Original
PDF BTA/BTB24, BTA25, BTA26 O-220AB BTB24) triac BTA 32 600 TRIAC BTA 28 triac bta26 triac BTA 32 triac BTA 140 triac bt 160 600v TRIAC BTA 4000 TRIAC BTA 20 600 BW BTA 600 12 triac T25 Series
triac bt 24 600v

Abstract:
Text: BTA /BTB08 and T8 Series 8A TRIACS SNUBBERLESS , LOGIC LEVEL & STANDARD MAIN FEATURES , BTA Tc(°C) 0 25 50 75 100 125 Fig. 3: Relative variation of thermal impedance , Tj initial=25°C Repetitive Tc= 100 °C Number of cycles 1 10 100 1000 5/10 BTA , DESCRIPTION Available either in through-hole or surface-mount packages, the BTA /BTB08 and T8 triac series is , in light dimmers, motor speed controllers,. The snubberless versions ( BTA /BTB.W and T8 series


Original
PDF BTA/BTB08 triac bt 24 600v TRIAC BTA 28 TRIAC BTB08 specifications TRIAC BTB08 600 TRIAC BTA series TRIAC BTa 24 TRIAC BTB 24 600 BW TRIAC BTB08 triac BTA 140 specifications of TRIAC BTB08
2000 - triacs bt 16 600v

Abstract:
Text: BTA /BTB16 and T16 Series ® 16A TRIACS SNUBBERLESSTM , LOGIC LEVEL & STANDARD MAIN , 125°C 4 A Tj = 125°C 1 W - 40 to + 150 - 40 to + 125 °C + 100 1/7 BTA , 100 125 1E-2 1E-3 1E-2 1E-1 1E+0 1E+1 1E+2 5E+2 BTA /BTB16 and T16 Series , 75 100 125 5/7 BTA /BTB16 and T16 Series Fig. 10:D²PAK Thermal resistance junction to , surface-mount packages, the BTA /BTB16 and T16 triac series is suitable for general purpose AC switching. They


Original
PDF BTA/BTB16 triacs bt 16 600v TRIAC BTA 28 TRIAC BT 136 triacs bt 16a 600v TRIAC BTa 12 600 triac bt 160 600v T1635 TRIAC BTA series circuit triac btb16 BTB16-XXXBW