The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
LTC3859AIFE#TRPBF Linear Technology LTC3859A - Low IQ, Triple Output, Buck/Buck/Boost Synchronous Controller with Improved Burst Mode Operation; Package: TSSOP; Pins: 38; Temperature Range: -40°C to 85°C
LTC3859AEFE#PBF Linear Technology LTC3859A - Low IQ, Triple Output, Buck/Buck/Boost Synchronous Controller with Improved Burst Mode Operation; Package: TSSOP; Pins: 38; Temperature Range: -40°C to 85°C
LTC3859AIUHF#PBF Linear Technology LTC3859A - Low IQ, Triple Output, Buck/Buck/Boost Synchronous Controller with Improved Burst Mode Operation; Package: QFN; Pins: 38; Temperature Range: -40°C to 85°C
LTC3859AEUHF#PBF Linear Technology LTC3859A - Low IQ, Triple Output, Buck/Buck/Boost Synchronous Controller with Improved Burst Mode Operation; Package: QFN; Pins: 38; Temperature Range: -40°C to 85°C
LTC3859AMPFE#PBF Linear Technology LTC3859A - Low IQ, Triple Output, Buck/Buck/Boost Synchronous Controller with Improved Burst Mode Operation; Package: TSSOP; Pins: 38; Temperature Range: -55°C to 125°C
LTC3859AEUHF#TRPBF Linear Technology LTC3859A - Low IQ, Triple Output, Buck/Buck/Boost Synchronous Controller with Improved Burst Mode Operation; Package: QFN; Pins: 38; Temperature Range: -40°C to 85°C

triac burst fire control ic Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
bta40 circuit

Abstract: scr specifications bta40800b BTA40-800B triac burst fire control back to back scr firing board X10641 triac bta40-700b firing circuit MPC34A burst fire controller
Text: MULTI-MODE MAINS CONTROLLER MPC34A BURST FIRED OR PHASE ANGLE X10641 INTRODUCTION The MPC34A provides accurate and precise mains control in both burst fire or phase angle control modes of operation. This printed circuit board firing circuit is capable of driving an external triac or thyristor , loads. MAIN FEATURES Dual mode control capability. (phase angle OR burst fire ) Soft start delay , phase angle and for burst fire control . X10255 SRA Safety requirements - addressing the Low Voltage


Original
PDF MPC34A X10641 MPC34A AP02/4 BS7671) IEC950) MPC34C bta40 circuit scr specifications bta40800b BTA40-800B triac burst fire control back to back scr firing board X10641 triac bta40-700b firing circuit burst fire controller
fire angle of scr circuit

Abstract: triac burst fire control a circuit for firing angle in triac 230V SCR speed control United Automation evr 25 scr phase angle controller X10255 X10229 X10213 BS7671
Text: burst fire control . X10255 SRA Safety requirements - addressing the Low Voltage Directive (LVD , MINI RANGE AC PHASE ANGLE AND BURST FIRE POWER REGULATORS STACKS EVR SERIES X10532 INTRODUCTION The EVR range of triac Mini Stacks are available for single phase, 230V applications. Other , control . All EVR triac stacks come complete with appropriately rated High Speed semiconductor fuses and , part number: EVR-25-Phase Angle/ Burst Fire . Optional extras include F-series Filter. Note: When


Original
PDF X10532 EVR-25-Phase fire angle of scr circuit triac burst fire control a circuit for firing angle in triac 230V SCR speed control United Automation evr 25 scr phase angle controller X10255 X10229 X10213 BS7671
230V SCR speed control

Abstract: a circuit for firing angle in triac triac burst fire control EVR25 United Automation evr 25 x10532 scr phase angle controller Triac slow on EVR-25-Phase United Automation evr 25 angle phase control
Text: burst fire control . X10255 SRA Safety requirements - addressing the Low Voltage Directive (LVD , MINI RANGE AC PHASE ANGLE AND BURST FIRE POWER REGULATORS STACKS EVR SERIES X10532 INTRODUCTION The EVR range of triac `Mini Stacks' are available for single phase, 230V applications. Other , control . All EVR triac stacks come complete with appropriately rated High Speed semiconductor fuses and , part number: EVR-25-Phase Angle/ Burst Fire . Optional extras include F-series Filter. Note: When


Original
PDF X10532 BS7671) EVR-25-Phase 230V SCR speed control a circuit for firing angle in triac triac burst fire control EVR25 United Automation evr 25 x10532 scr phase angle controller Triac slow on United Automation evr 25 angle phase control
1999 - 220v AC voltage stabilizer schematic diagram

Abstract: 10 pages project on zener diode PWM 220v ac stabilizer 12v dc motor by using triac triac burst fire control AC voltage stabilizer project Triac stabilizer application note voltage regulator using triac microcontroller base triac phase angle control TRIAC control
Text: AN1114 APPLICATION NOTE ® BURST MODE TRIAC CONTROL BY USING ST52x301 Authors: A. Cucuccio , configured for Burst mode triac control , a square wave, Tb, (Fig. 2) is generated with a duty cycle , of the main voltage included in the Ton of the fixed period. 2/13 BURST MODE TRIAC CONTROL BY , problem of the flicker standard (European Standard EN60555, Part 3) 4/13 BURST MODE TRIAC CONTROL , ) PULSE GENERATOR MAIN2 (20) TRIACOUT (24) Enable 6/13 BURST MODE TRIAC CONTROL BY USING


Original
PDF AN1114 ST52x301 ST52x301 ST52x301, 220v AC voltage stabilizer schematic diagram 10 pages project on zener diode PWM 220v ac stabilizer 12v dc motor by using triac triac burst fire control AC voltage stabilizer project Triac stabilizer application note voltage regulator using triac microcontroller base triac phase angle control TRIAC control
potentiometer 100k

Abstract: triac burst firing circuit 7 pin potentiometer triac burst fire control 100k potentiometer 7 pin of potentiometer 100k potentiometer 5 pins BFM-TH TRIAC applications Triac EMC
Text: addressing EMC Directive X10213 ITA Interaction, uses for phase angle and for burst fire control . X10255 , BFM-TH BURST FIRING TRIGGER CIRCUIT X10644 INTRODUCTION The BFM-TH is a -hybrid burst , applications with the addition of a potentiometer and triac . APPLICATIONS Virtually all resistance heaters , additional:o Potentiometer o Triac (power device) o Heatsink (for use with triac ) INSTALLATION Fixing , L I N E L N G L L O A D OPTIONAL NEON RATIO IND N MT1 TRIAC MT2


Original
PDF X10644 BS7671) IEC950) potentiometer 100k triac burst firing circuit 7 pin potentiometer triac burst fire control 100k potentiometer 7 pin of potentiometer 100k potentiometer 5 pins BFM-TH TRIAC applications Triac EMC
FC11BL2

Abstract: a circuit for firing angle in triac X10229 X10255 triac burst firing circuit X10213 zero crossing resistive power control adjustable zero span circuit triac burst fire control fast acting circuit breakers mcb
Text: burst fire control . X10255 SRA Safety requirements - addressing the Low Voltage Directive (LVD , BURST FIRE FIRING TRIGGER MODULE C/W INTEGRAL 25A POWER DEVICE FC11BL/2 X10261 , which is proportional to the manual control signal or dc input demand signal. The burst firing circuit , connections. Ideal for heating loads up to 25 Amps, when fitted onto a suitable heatsink. Burst firing , heating and other temperature control applications, up to 25 amps when fitted on to a suitable heatsink


Original
PDF FC11BL/2 X10261 BS7671) FC11BL2 a circuit for firing angle in triac X10229 X10255 triac burst firing circuit X10213 zero crossing resistive power control adjustable zero span circuit triac burst fire control fast acting circuit breakers mcb
triac soft starting circuit

Abstract: triac burst fire control fire angle of scr circuit scr phase angle controller United Automation evr 25 x10532 230V SCR speed control X10255 X10229 X10213 BS7671
Text: phase angle and for burst fire control . X10255 SRA Safety requirements - addressing the Low Voltage , MINI RANGE AC PHASE ANGLE AND BURST FIRE POWER REGULATORS STACKS EVR SERIES X10532 INTRODUCTION The EVR range of triac `mini stacks' are available for single phase, 230V applications (other voltage supplies are available). They can control loads of up to 25A, with a number of signal control , . ORDER CODE State part number: EVR-25-Phase Angle/ Burst Fire . Optional extras include F-series Filter


Original
PDF X10532 BS7671) EVR-25-Phase triac soft starting circuit triac burst fire control fire angle of scr circuit scr phase angle controller United Automation evr 25 x10532 230V SCR speed control X10255 X10229 X10213 BS7671
controlling heater with triac

Abstract: potentiometer 100k triac burst fire control triac ts32 TRIAC heater temperature control scr for 230V AC SCR 30A 500V ac regulator proportional controlling heater with triac DATASHEET SCR
Text: capability Burst fire control - RFI free DIN rail mounting Simple 2.5mm2 DIN rail mounting 230V ac , phase angle and for burst fire control . X10255 SRA Safety requirements - addressing the Low Voltage , 25A VARIABLE BFM-240-25 BURST FIRED AC REGULATOR X10640 INTRODUCTION The BFM-240-25 is a mains supply, 25A ac energy regulator for proportional linear manual control of resistive loads , high current triac , fuse, terminals and all main parts are enclosed and mounted on an integral


Original
PDF BFM-240-25 X10640 BFM-240-25 BS7671) IEC950) controlling heater with triac potentiometer 100k triac burst fire control triac ts32 TRIAC heater temperature control scr for 230V AC SCR 30A 500V ac regulator proportional controlling heater with triac DATASHEET SCR
ac motor speed control circuit with triac 230v

Abstract: 110vac motor variable speed control circuit AC single phase motor rc snubber 230V variable speed control single phase ac motor speed control with triac single phase ac motor speed control used triac triac RC snubber fan motor triac control application induction potentiometer X10229
Text: X10213 ITA Interaction, uses for phase angle and for burst fire control . X10255 SRA Safety , - addressing EMC Directive X10213 ITA Interaction, uses for phase angle and for burst fire , control of inductive loads and a Minimum Set Speed adjuster (at the rear) to allow the designer/installer to fix a minimum output voltage level to prevent a motor being driven too slowly. The large Triac , Speed Adjuster. · Single hole fixing. · Rugged and compact. · Large triac for inrush


Original
PDF 15Amps VAC2/S-15E VAC1/S-15E X10690 A72226 230vAC) A72160 110vAC) ac motor speed control circuit with triac 230v 110vac motor variable speed control circuit AC single phase motor rc snubber 230V variable speed control single phase ac motor speed control with triac single phase ac motor speed control used triac triac RC snubber fan motor triac control application induction potentiometer X10229
triac burst fire control

Abstract: 5k pot fire angle of scr circuit ZAX27A thyristor firing circuit X20008 X10255 X10229 X10213 BS7671
Text: MULTI-MODE MAINS MODULE ZAX27A BURST FIRED OR PHASE ANGLE X10646 INTRODUCTION The ZAX27A provides accurate and precise mains control in both burst fire or phase angle control modes of , loads. MAIN FEATURES Dual mode control capability. (phase angle OR burst fire ) Soft start delay , angle and for burst fire control . X10255 SRA Safety requirements - addressing the Low Voltage , Angle SW1 (OFF) = Burst Fire WARNING 1. This unit requires fusing. This should be a fast acting


Original
PDF ZAX27A X10646 ZAX27A BS7671) IEC950) triac burst fire control 5k pot fire angle of scr circuit thyristor firing circuit X20008 X10255 X10229 X10213 BS7671
potentiometer 2K

Abstract: transformer from 230V AC to 5V DC 230V variable speed control 110V AC to 5V DC transformer BS7671 X10213 X10229 X10255 transformer from 230V AC to 5V
Text:  BURST FIRE FIRING TRIGGER MODULE C/W INTEGRAL 25A POWER DEVICE FC11BL/2 X10261 This single , to the manual control signal or dc input demand signal. The burst firing circuit provides trigger , FEATURES • Integral 25 amp triac fitted. • Universal Span & Zero matching to voltage or mA control , recommendation - addressing EMC directive. X10213 ITA Interaction, uses for phase angle and for burst fire , heating loads up to 25 Amps, when fitted onto a suitable heatsink. Burst firing operates on a 1 second


OCR Scan
PDF FC11BL/2 X10261 BS7671) potentiometer 2K transformer from 230V AC to 5V DC 230V variable speed control 110V AC to 5V DC transformer BS7671 X10213 X10229 X10255 transformer from 230V AC to 5V
TRIAC PHASE ANGLE CONTROLLER

Abstract: scr firing circuit ac regulator thyristor firing circuit how to control firing angle in thyristor 230V SCR speed control thyristor manual triac firing circuit scr firing circuit triac burst fire control angle phase control
Text: for phase angle and for burst fire control . X10255 SRA Safety requirements - addressing the Low , MINI RANGE AC PHASE ANGLE AND BURST FIRE POWER REGULATORS STACKS EVR SERIES X10532 , supplies are available). They can control loads of up to 25A, with a number of signal control options. The stacks are assembled to suit the final load with options of phase angle, burst firing control . All EVR , number: EVR-25-Phase Angle/ Burst Fire Optional extras include F-series Filter. Note: When ordering a


Original
PDF X10532 BS7671) EVR-25-Phase TRIAC PHASE ANGLE CONTROLLER scr firing circuit ac regulator thyristor firing circuit how to control firing angle in thyristor 230V SCR speed control thyristor manual triac firing circuit scr firing circuit triac burst fire control angle phase control
TRIAC PHASE ANGLE CONTROLLER

Abstract: how to control firing angle in thyristor thyristor firing circuit scr firing circuit United Automation evr 25 x10532 triac burst fire control United Automation evr 25 phase angle scr firing circuit ac regulator 230V SCR speed control
Text: for phase angle and for burst fire control . X10255 SRA Safety requirements - addressing the Low , MINI RANGE AC PHASE ANGLE AND BURST FIRE POWER REGULATORS STACKS EVR SERIES X10532 , supplies are available). They can control loads of up to 30A, with a number of signal control options. The stacks are assembled to suit the final load with options of phase angle, burst firing control . All EVR , number: EVR-25-Phase Angle/ Burst Fire Optional extras include F-series Filter. Note: When ordering a


Original
PDF X10532 BS7671) EVR-25-Phase TRIAC PHASE ANGLE CONTROLLER how to control firing angle in thyristor thyristor firing circuit scr firing circuit United Automation evr 25 x10532 triac burst fire control United Automation evr 25 phase angle scr firing circuit ac regulator 230V SCR speed control
Triac trigger circuit

Abstract: triac burst fire control TRIAC heater temperature control control heater with triac element triac controller parallel triac 100k potentiometer TRIAC heater temperature controller Triac EMC triac temperature control
Text: BFM-TH DESCRIPTION: The BFM-TH is a Hybrid Triac Trigger circuit requiring only the inclusion of a 100k potentiometer and a suitable triac to give compact versatile power control . The controller operates on a burst fire principle over a time period of approximately one second, offering manual control , complies with European CE Directives for EMC. Also, because the switching element is a triac there are no , driving any triac up to, and including, a gate current of 100 mA. Indicator: For a visual display


Original
PDF 100mA Triac trigger circuit triac burst fire control TRIAC heater temperature control control heater with triac element triac controller parallel triac 100k potentiometer TRIAC heater temperature controller Triac EMC triac temperature control
thyristor TAG 103 X

Abstract: thyristor st 103 Thyristor TAG 3 phase MCB installation drawing thyristor TAG 103 triac tag f1 FC11AL2 phase angle control using IC triac burst fire control ic TAG thyristor
Text: - addressing EMC Directive. X10213 ITA Interaction, uses for phase angle and for burst fire control , . BURST FIRE Graphs show load voltage against time on 1 second repeating pattern time base at 30% and 60 , response. BURST FIRE FIRING FEATURES Using Zero Volts Switching (ZVS) burst firing, the alternative form , changes in load current, and thus virtually no RFI is produced. UAL burst fire circuits are available and , M f « N IC E U0RK nOUHTING INSTRUCTIONS M IL L ft M .t a HOLE UHEM F IX IMS C$K TO H 001TU M I


OCR Scan
PDF X10282 thyristor TAG 103 X thyristor st 103 Thyristor TAG 3 phase MCB installation drawing thyristor TAG 103 triac tag f1 FC11AL2 phase angle control using IC triac burst fire control ic TAG thyristor
triac burst fire control

Abstract: SCR 30A 500V triac 600V 25A BS7671 voltage regulator using triac controlling heater with triac SCR 25a X10229 SCR Phase Control scr manual
Text: Interaction, uses for phase angle and for burst fire control . X10255 SRA Safety requirements - addressing , 25A VARIABLE BURST FIRED AC REGULATOR BVR X10212 INTRODUCTION The BVR-25 is a powerful OEM 25A ac energy regulator for proportional linear manual control of resistive loads using variable on , triac , fuse, terminals and all main parts are enclosed and mounted on an integral heatsink to ensure , speed fuse. · Built in heatsink. · RFI free. · Single entry cable gland. · Control knob and dial


Original
PDF X10212 BVR-25 BS7671) IEC950) BVR-25A triac burst fire control SCR 30A 500V triac 600V 25A BS7671 voltage regulator using triac controlling heater with triac SCR 25a X10229 SCR Phase Control scr manual
triac burst fire control

Abstract: 230V SCR speed control Triac Heat Sink assembly automatic room power controller using scr 3kw triac 5kw switching power supply design marking 3kw 30A high speed diode SCR voltage dc CONTROL 0-10v 3 kw triac
Text: 1.5KW, 3KW and 6KW HVAC RANGE 1-PHASE BURST FIRE AC POWER REGULATOR STACKS PR1-E SERIES X10591 INTRODUCTION The PR1-E range of triac . assemblies, provide full seamless control of single-phase resistive loads of 1.5KW, 3.0KW and 6.0KW, using burst fire control . Signal control is by a DC signal. These burst fire control assemblies use fast pulse zero volts switching technology, to minimise , Interaction, uses for phase angle and for burst fire control . X10255 SRA Safety requirements: Addressing


Original
PDF X10591 F13006 F16207 F11307 triac burst fire control 230V SCR speed control Triac Heat Sink assembly automatic room power controller using scr 3kw triac 5kw switching power supply design marking 3kw 30A high speed diode SCR voltage dc CONTROL 0-10v 3 kw triac
X10647

Abstract: triac burst firing circuit Triac code application note triac burst fire control X10229 triac switch phase control of triac Triac BS7671 triac phase control
Text: addressing EMC Directive X10213 ITA Interaction, uses for phase angle and for burst fire control . X10255 , PHASE ANGLE TRIAC PATFC FIRING CIRCUIT X10647 INTRODUCTION The PATFC is a thick-film hybrid firing circuit, which gives phase control and is therefore useful as a simple proportional control firing circuit for driving an appropriate triac power device to suit most load applications , Simple triggering device Requires additional:o Potentiometer o Triac power device o Heatsink (for use


Original
PDF X10647 2002/95/EC IEC950) X10647 triac burst firing circuit Triac code application note triac burst fire control X10229 triac switch phase control of triac Triac BS7671 triac phase control
2006 - Precision triac control thermostat

Abstract: OM1682A triac 1500w triac burst fire control ic thermostat cap triac drive circuit water heater control using triac TRIAC BTA 16 application note HEF4093 triac applications circuit diagram
Text: Specification OM1682A Precision triac control thermostat With MOD false the burst interval terminates as , OM1682A Precision triac control thermostat 1 2 FEATURES · Low external component count , access, allowing monitoring of the input, and external control of the triac drive. · Variable ON and , The triac firing circuit is arranged to zero-crossing fire a resistive load; or by the use of option , Contents are subject to the Disclaimer 1 Product Specification OM1682A Precision triac control


Original
PDF OM1682A OM1682A Precision triac control thermostat triac 1500w triac burst fire control ic thermostat cap triac drive circuit water heater control using triac TRIAC BTA 16 application note HEF4093 triac applications circuit diagram
INTRODUCTION OF AUTOMATIC ROOM power CONTROL

Abstract: X10255 3kw triac scr for 230V AC marking 3kw remote fire sensor SCR voltage dc CONTROL 0-10v BS7671 X10213 F13006
Text: 1.5KW, 3KW and 6KW HVAC RANGE 1-PHASE BURST FIRE AC POWER REGULATOR STACKS PR1-E SERIES X10591 INTRODUCTION The PR1-E range of triac . assemblies, provide full seamless control of single-phase resistive loads of 1.5KW, 3.0KW and 6.0KW, using burst fire control . Signal control is by a DC signal. These burst fire control assemblies use fast pulse zero volts switching technology, to minimise , Interaction, uses for phase angle and for burst fire control . X10255 SRA Safety requirements: Addressing


Original
PDF X10591 F13006 F16207 F11307 INTRODUCTION OF AUTOMATIC ROOM power CONTROL X10255 3kw triac scr for 230V AC marking 3kw remote fire sensor SCR voltage dc CONTROL 0-10v BS7671 X10213 F13006
TRIAC MODULE

Abstract: X10224 triac phase control scr for 230V AC angle phase control triac burst fire control application note triac protection triac drive circuit Triac/SCR X10229
Text: for burst fire control . X10255 SRA Safety requirements - addressing the Low Voltage Directive (LVD , MANUAL PHASE ANGLE TRIAC TRIGGER MODULE MAT X10224 INTRODUCTION The MAT is a variable phase angle triac trigger module. It is a compact, safe and tamperproof unit capable of driving all typical triacs on 230/110V ac regulator circuits. The unit has an inclusive manual control potentiometer , for most ac resistive or inductive loads via a triac , on single phase to neutral supplies, within


Original
PDF X10224 230/110V AP02/4 BS7671) TRIAC MODULE X10224 triac phase control scr for 230V AC angle phase control triac burst fire control application note triac protection triac drive circuit Triac/SCR X10229
triac drive circuit

Abstract: TRIAC power control circuit application note triac protection triac firing circuit electronic firing circuit for ac power controller triac phase control triac burst fire control triac switch circuits Triac EMC controlling heater with triac
Text: Interaction, uses for phase angle and for burst fire control . X10255 SRA Safety requirements - addressing , PHASE ANGLE TRIAC PATFC FIRING CIRCUIT X10647 INTRODUCTION The PATFC is a thick-film hybrid firing circuit, which gives phase control and is therefore useful as a simple proportional control firing circuit for driving an appropriate triac power device to suit most load applications , additional:o Potentiometer o Triac power device o Heatsink (for use with triac ) INSTALLATION


Original
PDF X10647 BS7671) IEC950) triac drive circuit TRIAC power control circuit application note triac protection triac firing circuit electronic firing circuit for ac power controller triac phase control triac burst fire control triac switch circuits Triac EMC controlling heater with triac
triac 30a

Abstract: BS7671 X10213 X10229 X10255 ZVT-25 ZVT-25-IF
Text: Interaction, uses for phase angle and for burst fire control . X10255 SRA Safety requirements - addressing , BURST FIRED FLICKER INHIBITED 25A TEMPERATURE CONTROLLER ZVT-25-IF X10542 INTRODUCTION , capability, is ideal for high power, closed loop temperature control applications. Using variable on/off , high current triac , fuse, terminals and all main parts are enclosed and it is mounted on an integral , with a control knob and ZVT scaled dial (0 to 40°C or 0 to +150°C). The temperature sensor is ordered


Original
PDF ZVT-25-IF X10542 ZVT-25 BS7671) IEC950. /230V -25-IF- C/0-150 ZVT-E-10K3A1 triac 30a BS7671 X10213 X10229 X10255 ZVT-25-IF
star delta triac

Abstract: opto triac angle phase control Star Delta Control panel wiring three phase triac control x10642 BS7671 X10213 X10229 X10255
Text: switching Burst fire control Opto isolated outputs LED output control indicators DIN rail mounting (both , recommendation - addressing EMC Directive X10213 ITA Interaction, uses for phase angle and for burst fire , BURST FIRING TRIGGER MODULES BFTM-1 BFTM-3 X10642 1 & 3 PHASE INTRODUCTION The BFTM-1 and BFTM-3 single and three phase burst firing trigger modules designed to drive our full range of , one-phase supply controlling three phase loads in star or delta configurations. The control input signal


Original
PDF X10642 BS7671) IEC950) star delta triac opto triac angle phase control Star Delta Control panel wiring three phase triac control x10642 BS7671 X10213 X10229 X10255
X1025

Abstract: No abstract text available
Text: recommendation - addressing EMC Directive ITA Interaction, uses for phase angle and for burst fire control . SRA , f . > UNITED AUTOMATION BURST FIRED INHIBITED FLICKER TEMPERATURE , control applications. Using variable on/off bursts of complete mains cycle energy, coincident with mains zero crossover to avoid RFI problems. The high current triac , fuse, terminals and all main parts are , Suitable for temperature control of single phase resistive heaters, ovens, dryers, hot plates and flexible


OCR Scan
PDF ZVT-25-IF ZVT-25 BS7671) IEC950) ZVT2-25-IF ZVT-16/25-IF-E IS09001 X1025