The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
PMP8012 Texas Instruments TPS92310 - 220VAC, 8W Isolated , Triac dimmable
PMP6002 Texas Instruments TRIAC Dimmable 120V LED Lighting Driver Controller (32V@350mA)
LM3445-REF Texas Instruments 230 Vac Off-line Triac Dimmer Retrofit with 6 LEDs Reference Design
LM3497MM/NOPB Texas Instruments LM3497 Triac Dimmable Offline LED Driver 10-MSOP
LM3497M/NOPB Texas Instruments LM3497 Triac Dimmable Offline LED Driver 14-SOIC
PMP6003 Texas Instruments TRIAC Dimmable 230V LED Lighting Driver Controller (32V@350mA)

triac BT 80 Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
2008 - triacs BTA

Abstract:
Text: can pose a particular challenge. NXP's BTA208X-1000C triac offers best-in-class performance in this , the AC mains supply. Each triac 's operation has to be mutually exclusive, to avoid uncontrolled , sinusoidal voltage (higher than the mains supply voltage), and the triac needs to be able to block the , inductor is not necessary The NXP BTA208X-1000C is the only three-quadrant Hi-Com triac to guarantee a , , motor speed varies widely. A triac is typically used to control the speed, via phase-control of the


Original
PDF
2007 - 1M preset

Abstract:
Text: and surface-mount options G+ The simple, reliable and inexpensive triac is used to control , Eliminates need for snubber circuit High dVD/dt Triac voltage Inductive load Three-quadrant triac 100 carbon composition resistor 100nF 250V AC SNUBBER NOT REQUIRED Ñ igher dVcom/dt , commutation - Eliminates need for snubber circuit Triac voltage High dVCOM/dt Inductive load Three-quadrant triac 100 carbon composition resistor 100nF 250V AC Load Current SNUBBER NOT


Original
PDF BTA225 BTA225B 1M preset triac bt 13 h preset variable resistor 1m triac analog control for inductive loads 1M preset, horizontal L56R BT139 motor speed control 100n N 250v X2 induction heater microcontroller washing machine drain valve types
triac BT 24

Abstract:
Text: N AMFR PHILIPS/DISCRETE b«ÌE T> bbsg'oi DD272n no hapx BT 138 SERIES X TRIACS , Respective Manufacturer I I N AMER PHILIPS/DISCRETE BT 138 SLKItb b^E T> bbSB^l 0D27HH0 'iOH MAPXl A , VDSM VDRM VDWM 'T(RMS) max-'TRM max- ■tsm 'tsm l2t BT 138- -500 600 700 800 max. 500* 600* 700 , , but the triac may switch into the on-state. The rate of rise of on-state current should not exceed 15 , Respective Manufacturer N AMER PHILIPS/DISCRETE BT 138 SLKItb blE » (^53^31 DD27252 70S «APX JL vT


OCR Scan
PDF DD272n bt138-500 220AB BT138 BT138F triac BT 24 triacs bt 138 TRIAC 138 BT 138 triac BT 138 triac BT 4 400 TRIAC TAG 90 triac BT 24 600
BTi36

Abstract:
Text: ) max- BT 136- -500 600 700 800 max. 500 600 700 800 'tsm 'tsm max. max. 25 30 V A A MECHANICAL DATA Fig , . ^Although not recommended, off-state voltages up to 800 V may be applied without damage, but the triac may , will not trigger any device; Tj = 120 °C; gate open circuit BT 136 series dVD/dt < 100 V/fis BT 136 series G dVD/dt < 200 V/jis BT 136 series F dVD/dt < 50 V/m s BT136 series E dVD/dt typ. 50 V , current {!(.) Latching current (![_); Vq = 12 V T2+ G+ BT136 series BT 136 series G BT136 series F BT136


OCR Scan
PDF 00bE23a BT136 BT136F d8573 BTi36 TRIAC BT 136 triac BT 06 400 triac BT 06 600 BT 136 TRIAC TRIAC BY 136 triac BT 06 700 PH 600D B 134 bt 136
1997 - triac BT 140

Abstract:
Text: requirement the value of tp can be calculated. eg. for triac BT 139 (data sheet 2488) worst case holding , number 307-985 A zero voltage switch IC offering symmetrical burst control of an external triac , triac firing under noisy mains conditions q Low external component count q Symmetrical burst control , °C unless otherwise stated Parameter Pin 3 voltage Supply current, I2 Rp resistance range Triac gate , Total power dissipation Conditions I = 16mA Excluding triac trigger pulse and pin 5 output total


Original
PDF
triac BT 317

Abstract:
Text: N AMER PHILIPS/DISCRETE b^E T> m bbSa^Bl 002715b 1Ô7 HIAPX BT 134 SERIES y v. TRIACS , damage, but the triac may switch into the on-state. The rate of rise of on-state current should not , 1.8 A/ms; ¡T BT 134 series dVcom/dt typ. 10 V/fis BT 134 series G dVcom/dt < 10 V/jus BT 134 series F dVCom/dt typ. 10 V/a-s Off-state , the terminals does not exceed 125 °C. During these overload conditions the triac may lose control


OCR Scan
PDF 002715b bt134-500 BT134G BT134 00271b5 BT134F triac BT 317 BT 317 triac triac BT 06 600 triac BT 24 BT134-500D triac BT 06 400 triac BT 06 700 triac BT 134 00S7
1995 - triac BT 140

Abstract:
Text: requirement the value of tp can be calculated. eg. for triac BT 139 (data sheet 2488) worst case holding , number 307-985 A zero voltage switch IC offering symmetrical burst control of an external triac , triac firing under noisy mains conditions q Low external component count q Symmetrical burst control , °C unless otherwise stated Parameter Pin 3 voltage Supply current, I2 Rp resistance range Triac gate , Total power dissipation Conditions I = 16mA Excluding triac trigger pulse and pin 5 output total


Original
PDF
1984 - 2kw TRIAC control

Abstract:
Text: can be calculated. p eg. for triac BT 139 (see data sheet 2488) worst case holding current I = 30mA , . offering symmetrical burst Features control of an external triac . Ideal for power control in l High immunity against spurious triac firing many heating applications. under noisy mains conditions l Low , triac trigger pulse and pin 5 output - -7.2 mA R resistance range total 18 -140 kW p Triac gate drive , 2V 80 100 -mA output current (peak) Vg = 4V 50 70 -mA output current (peak) short circuit - -200 mA


Original
PDF J7770 2kw TRIAC control TRIAC 226 d triac BT 140 triac burst firing circuit Automatic Voltage stabilizer 5 kw J7770 zero detector ic of ac mains triac BT 139 triac burst control ic Peak level meter ic
diac D30

Abstract:
Text: 75234 (214) 241-3511 T W X . 910-860*5537 JAN. 1974/HOT bT HUTSON INDUSTRIES 4644700 HUTSON , 60 Hz It s m 80 100 Peak Gate-Trigger Current for 3 /tsec. Max. Ig t m 1 1 , . Ig t 50 Max. 80 Max. 50 Max. 80 Max. Vgt 2.5 Max. 2.5 Max. T et 2.5 Typ , NUM BkR (1) HUTSON . 15 AMP ■DEVICE - N UM BER (1) bT l ) E | m 34 4 7 0 G O D O , T315 T415 T515 T615 T025 T125 T225 T325 T425 T525 T625 VOLT TRIAC


OCR Scan
PDF 4ti44700 D0DD113 diac D30 HUTSON INDUSTRIES TRIAC
Not Available

Abstract:
Text: /DISCRETE BT136F SERIES b'lE D bt >S3^31 0027165 T l l ff J v. RATINGS Limiting values in , recommended, off-state voltages up to 800 V may be applied w ithout damage, but the triac may switch into the , humidity <65% under clean and dust-free conditions. -\ 80 March 1993 r N AMER , 15 20 10 15 15 25 15 20 mA mA mA BT 136F — 500D/600D 82 'g t lH !g t , J MOUNTING INSTRUCTIONS 1. The triac may be soldered directly into the circuit, but the maximum


OCR Scan
PDF D0271fl4 BT136F OT-186 BT136Fâ 10Typical
triac BT 137

Abstract:
Text: PHILIPS INTERNATIONAL bSE D 711GÖ2L, D0b2Ebl 27b HIPHIN BT 137 SERIES s V TRIACS Glass-passivated , BT 137 -500 600 700 800 max. 500 600 700 800 max. max. max. 55 60 V A A MECHANICAL DATA Fig.1 TOâ , either direction) BT 137-500 600 700 800 Non-repetitive peak off-state voltage (t < 10 ms)t VDSM max , without damage, but the triac may switch into the on-state. The rate of rise of on-state current should , the terminals does not exceed 125 °C. During these overload conditions the triac may lose control


OCR Scan
PDF 00b2271 BT137 M1Q41 BT137F D8573 M81-1647/1 triac BT 137 triac BT 137 800 philips d8614 BT 137 triac triac bt 135 bt 137 TRIAC TAG 91 triac BT 137 600 triac BT 06 600
triac tag 87

Abstract:
Text: - *Although not recommended, off-state voltages up to 800 V may be applied without damage, but the triac may , current (l|_j) Latching current (l[_); Vq = 12 V T2+ G+ BT136 series BT 136 series G BT136 series F BT 136 series E BT 136—500D/600D GT > 35 H < 15 L <20 GT > 50 H < 30 L <30 GT H L > 25 < 15 < 20 GT H L > 10 , temperature of the terminals does not exceed 125 °C. During these overload conditions the triac may lose , based on sinusoidal currents (f = 50 Hz); Tj = 120 °C prior to surge. The triac may temporarily lose


OCR Scan
PDF 711Da2b 0Db523Ã BT136 BT136-500 M1625 BT136G 711002b 00b224Ã M1644 triac tag 87 TRIAC BT 136 working triac bt136 triac bt 135 BT 136 TRIAC TRIAC BT 136-500D TO220 triac BT 06 400 D8384 BT-136
TRIAC BT 136

Abstract:
Text: - *Although not recommended, off-state voltages up to 800 V may be applied without damage, but the triac may , V T2+ G+ BT136 series BT 136 series G BT136 series F BT 136 series E BT 136—500D/600D GT , the temperature of the terminals does not exceed 125 °C. During these overload conditions the triac , . on-state current based on sinusoidal currents (f = 50 Hz); Tj = 120 °C prior to surge. The triac may , IPHIN M 1 643 Fig.8 Typical commutation dV/dt for BT136 series versus Tj. The triac should commutate


OCR Scan
PDF 711Da2b 00bS23Ã BT136 BT136-500 711005b 00b224Ã M1644 BT136F D8573 TRIAC BT 136 BT 136 TRIAC working triac bt136 temperature control by triac BT136 triac bt 135 bt136 triac TRIAC TAG 90 BT136 motor BT136 application note
triac BT 408

Abstract:
Text: BT A2 6 SERI ES ST AN DARD 2 6 A T RI ACs ï®ï€ MAIN FEATURES Symbol Value Unit IT , DESCRIPTION Available either in through-hole or surface and T25 mount packages, the BTA/BTB 24-25-26 triac , temperature range V -40 to+125 38 H SiN BT A2 6 SERI ES ï®ï€ STATIC CHARACTERISTICS Tj , ) lTM=35A (2) (2) VTM Rd 25 ALL VGT Vt0 MAX. B ll 80 40 70 80 160 mA mA Tj=25 MAX. 1.6 V Threshold voltage Tj=125 MAX. 0.85 V


Original
PDF
2013 - 1 kilo ohm resistor specifications

Abstract:
Text: GuardSwitch Series 300 Switches 301- BT and 303- BT Installation Sheet Figure 1: Dimensions Description The 301- BT Series 300 DPST safety interlock switch is designed for use with safety monitored relays or monitored circuits. To achieve the optimum Series 300 defeat resistant feature of the 301- BT , The housing of the 300- BT must be connected to the PE (Primary Earth) ground circuit via a lock , or nuts. See ordering information for details. Set range at 20 mega ohms (switches with triac


Original
PDF 301-BT 303-BT 301-BT, 73/23/EEC) EN60204-1 EN292 EN954-1 EN55081-2 EN50082-2 1 kilo ohm resistor specifications 2.2 kilo ohm resistor specifications RESISTOR 50 KILO OHM
triac bt 135

Abstract:
Text: current 'T(RMS) Non-repetitive peak on-state current at 50 Hz ITS(V] at 60 Hz lTSM BT 139- -500 600 700 , (in either direction) BT 139- -500 600 700 800 Non-repetitive peak off-state voltage (t< 10 ms) VDSM , recommended, off-state voltages up to 800 V may be applied without damage, but the triac may switch into the , ; = 120 °C; gate open circuit 1.6 bt 139 series dVD/dt < 100 V/MS bt139 series G dVD/dt < 200 V/MS , temperature of the terminals does not exceed 125 °C. During these overload conditions the triac may lose


OCR Scan
PDF 711002b 00L23Q7 BT139 220AB triac bt 135 triac BT 140 TAG 84 triac bt 139 BT 139 F applications note TRIAC BT 139 BT 140 triac triac BT 147 triac BT 24
2002 - BT 130 triac

Abstract:
Text: BTB04-600SL ® STANDARD 4A TRIAC MAIN FEATURES A2 Symbol Value Unit IT(RMS , -600SL 4 quadrants TRIAC is intended for general purpose applications where high surge current capability is required, such as lighting, corded power tools, industrial. This TRIAC features a gate current , Type Package BTB04-600SL 600V 10 mA Standard TO-220AB ORDERING INFORMATION BT B 04 - 600 SL S: SENSITIVITY = 10mA L: LIGHTING APPLICATION TRIAC SERIES


Original
PDF BTB04-600SL BTB04-600SL O-220AB BT 130 triac triac BT 130 BT 130 600 E triac
2002 - BT 130 triac

Abstract:
Text: BTB04-600SL ® STANDARD 4A TRIAC MAIN FEATURES A2 Symbol Value Unit IT(RMS , -600SL 4 quadrants TRIAC is intended for general purpose applications where high surge current capability is required, such as lighting, corded power tools, industrial. This TRIAC features a gate current , -220AB ORDERING INFORMATION BT B 04 - 600 SL S: SENSITIVITY = 10mA L: LIGHTING APPLICATION TRIAC SERIES INSULATION B: non insulated VOLTAGE: 600V CURRENT: 4A Fig. 1: Maximum power


Original
PDF BTB04-600SL BTB04-600SL O-220AB BT 130 triac triac BT 130 600SL btb04600sl btb04 600v 4a triac btb04-600sl equivalent BT 130 600 E triac btb04 600sl triac btb04 600 SL
2002 - btb04 600 sl

Abstract:
Text: BTB04-600SL ® STANDARD 4A TRIAC MAIN FEATURES A2 Symbol Value Unit IT(RMS , -600SL 4 quadrants TRIAC is intended for general purpose applications where high surge current capability is required, such as lighting, corded power tools, industrial. This TRIAC features a gate current , Type Package BTB04-600SL 600V 10 mA Standard TO-220AB ORDERING INFORMATION BT B 04 - 600 SL S: SENSITIVITY = 10mA L: LIGHTING APPLICATION TRIAC SERIES


Original
PDF BTB04-600SL BTB04-600SL O-220AB btb04 600 sl
triac BT 137

Abstract:
Text: PHILIPS INTERNATIONAL bSE D B TllOûSfci DOLEEtil 27b HIPHIN BT 137 SERIES y v. TRIACS , damage, but the triac may switch into the on-state. The rate of rise of on-state current should not , 30 45 piA !GT > 10 10 10 25 mA BT 137 series E l|H < 20 20 20 20 mA ' L < 25 35 25 35 mA , does not exceed 125 °C. During these overload conditions the triac may lose control. Therefore the , based on sinusoidal currents (f = 50 Hz); Tj = 120 °C prior to surge. The triac may temporarily lose


OCR Scan
PDF BT137â triac BT 137 TRIAC TAG 137 Triacs bt 137 TRIAC TAG 91 BT137 application note BT137-500 TRIAC TAG 90 triac BT 137 800 triac BT 16 rating triac BT 41
2006 - BT 130 600 E triac

Abstract:
Text: 30 40 50 60 70 80 90 100 110 120 130 Figure 9: Ordering Information Scheme BT A 20 - 600 , BTA20-600BWRG BTA20-600CWRG BTA20-700BWRG BTA20-700CWRG mA DESCRIPTION The BTA20 BW/CW triac , 90 - MAX. - 80 TYP. 750 500 MIN. 500 250 TYP. 36 22 MIN , 80 100 120 Figure 4: Relative variation of thermal impedance versus pulse duration K=[Zth , values) 80 90 100 0.01 1.E-3 110 120 130 characteristics 1.E-2 1.E-1 1


Original
PDF BTA20 BTA20-600BWRG BTA20-600CWRG BTA20-700BWRG BTA20-700CWRG BTA20-600BW BTA20-600CW BTA20-700BW BTA20-700CW BT 130 600 E triac BT 130 triac triacs bt 16 600v BTA20-600B BTA20-600BW triacs bt 12 600v
M1641 TRIAC

Abstract:
Text: PHILIPS INTERNATIONAL bSE D B 711002t. DDtiEEbl 27b HIPHIN BT 137 SERIES y v. TRIACS , recommended, off-state voltages up to 800 V may be applied without damage, but the triac may switch into the , BT137 series F lH < 20 20 20 20 mA ' L < 30 45 30 45 piA !GT > 10 10 10 25 mA BT 137 series E l|H , temperature of the terminals does not exceed 125 °C. During these overload conditions the triac may lose , on sinusoidal currents (f = 50 Hz); Tj = 120 °C prior to surge. The triac may temporarily lose


OCR Scan
PDF 711002t. BT137- BT137G 711002b 00bS271 BT137 M1641 BT137F D8573 M1641 TRIAC BT137 CIRCUITS TRIAC TAG 91 TRIAC TAG 626 400 bt137* soldering iron temperature control triac BT 137 BT137-500D TRIAC TAG 97
1995 - BT 130 triac

Abstract:
Text: operation we recommend : BZW04376B or BT . for a 400 V triac (110 VAC mains) we propose a BZW04188B , obtained with a 50/60 Hz transformer. The power supplied to the oven is controlled by a triac in series with the primary (fig.1). Figure 1 : Magnetron power supply controlled by a triac . HV AC 1 , state ! To reduce the stresses at every switching on the circuit and particularly on the triac it is , (continous rating) B Saturation induction BS Bmax = 2 Bn - Br. In the circuits controlled by a triac


Original
PDF
triac BT 137

Abstract:
Text: , industrial and domestic heating control and static switching systems. QUICK REFERENCE DATA BT 137-500 600 , Non-repetitive peak on-state current; BT 137 -500 600 700 800 VDSM max. 500* 600* 700* 800 V VDRM max. 500 , . "Although not recommended, off-state voltages up to 800 V may be applied without damage, but the triac may , temperature of the terminals does not exceed 125 °C. During these overload conditions the triac may lose , sinusoidal currents (f = 50 Hz); Tj = 120 °C prior to surge. The triac may temporarily lose control


OCR Scan
PDF BT137 triac BT 137 BT137 application note BT137 Series E BT 137 triac triac BT137 btb 137 TRIAC TAG 137 triac BT 137 800 BT137-500D
working triac bt136

Abstract:
Text: System (IEC 134). Voltages (in either direction) BT 136-5 00 600 700 800 Non-repetitive peak , triac may switch into the on-state. The rate of rise of on-state current should not exceed 3 A//vs , T2+ G+ BT136 series bt 136 series G BT136 series F BT136 series E BT136—500D/600D GT H L , the triac may lose control. Therefore the overload should be terminated by a separate protection , triac may temporarily lose control following the surge


OCR Scan
PDF D027173 BT136 BT136-500 D0E71Ã BT136F d8673 working triac bt136 temperature control by triac BT136 triac bt136 TRIAC bt136 500d of TRIAC BT136 triac BT 136 triac bt136 characteristics lighting control by triac BT136 bt136 triac
Supplyframe Tracking Pixel