The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
SMJ320MCM42DHFNM40 Texas Instruments 32-BIT, 40MHz, OTHER DSP, CQFP408, CERAMIC, QFP-408
5962-9678902QXC Texas Instruments 32-BIT, 40MHz, OTHER DSP, CQFP408, CERAMIC, QFP-408
5962-9678901QXC Texas Instruments Dual SMJ320C40 Multichip Module, Digital Signal Processor 408-CFP -55 to 125
SMJ320MCM42CHFNM40 Texas Instruments 32-BIT, 40MHz, OTHER DSP, CQFP408, CERAMIC, QFP-408
PMP8012 Texas Instruments TPS92310 - 220VAC, 8W Isolated , Triac dimmable
LM3497MM/NOPB Texas Instruments LM3497 Triac Dimmable Offline LED Driver 10-MSOP

triac BT 408 Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
triac BT 408

Abstract: No abstract text available
Text: BT A2 6 SERI ES ST AN DARD 2 6 A T RI ACs ï®ï€ MAIN FEATURES Symbol Value Unit IT , DESCRIPTION Available either in through-hole or surface and T25 mount packages, the BTA/BTB 24-25-26 triac , temperature range V -40 to+125 38 H SiN BT A2 6 SERI ES ï®ï€ STATIC CHARACTERISTICS Tj , -220AB Insulated 39 Unit 60 /W /W H SiN BT A2 6 SERI ES PERFORM AN CE CU RV ES ï€ TO , sinusoidal pulse with width tp<10ms, and corresponding value of I2t 40 H SiN BT A2 6 SERI ES


Original
PDF
2008 - triacs BTA

Abstract: BC557 in smd package triac snubber ac motor SM1L43 triacs bt 12 Triac ACS108 controlling heater with triac washing machine drain valve types universal motor speed control wash ac motor control with triac
Text: can pose a particular challenge. NXP's BTA208X-1000C triac offers best-in-class performance in this , the AC mains supply. Each triac 's operation has to be mutually exclusive, to avoid uncontrolled , sinusoidal voltage (higher than the mains supply voltage), and the triac needs to be able to block the , inductor is not necessary The NXP BTA208X-1000C is the only three-quadrant Hi-Com triac to guarantee a , , motor speed varies widely. A triac is typically used to control the speed, via phase-control of the


Original
PDF
2007 - 1M preset

Abstract: triac bt 13 h preset variable resistor 1m triac analog control for inductive loads 1M preset, horizontal L56R BT139 motor speed control washing machine drain valve types induction heater microcontroller 100n N 250v X2
Text: and surface-mount options G+ The simple, reliable and inexpensive triac is used to control , Eliminates need for snubber circuit High dVD/dt Triac voltage Inductive load Three-quadrant triac 100 carbon composition resistor 100nF 250V AC SNUBBER NOT REQUIRED Ñ igher dVcom/dt , commutation - Eliminates need for snubber circuit Triac voltage High dVCOM/dt Inductive load Three-quadrant triac 100 carbon composition resistor 100nF 250V AC Load Current SNUBBER NOT


Original
PDF BTA225 BTA225B 1M preset triac bt 13 h preset variable resistor 1m triac analog control for inductive loads 1M preset, horizontal L56R BT139 motor speed control washing machine drain valve types induction heater microcontroller 100n N 250v X2
1998 - triac BT 408

Abstract: DIMMER BT136 600 TRIAC BT 136 SCHEMATIC dimmer triac dimmer microcontroller with zero crossing c light dimmer working circuit using triac conrad DIMMER BT136 Zilog dimmer equivalent for TRIAC BT136
Text: logic-level triac (for example, BT 136/600 D). The gate of this triac is decoupled with a 220nF/16V capacitor , . Therefore, wide firing-angle limits could result in an incorrect triac ignition. XTAL1 C R XTAL2 , ranging from ­0.7V to +0.7V. A low pass filter is required to filter voltage drops (generally after triac , , there are two external diodes for maximum port protection. The triac is ignited in the T2+G­ and T2­G­ quadrants. It is important that the Triac Terminal 1 is connected to a negative ground (GND=N). Note: The


Original
PDF Z86E02, 512-byte Z86E02 AN001700-Z8X0299 triac BT 408 DIMMER BT136 600 TRIAC BT 136 SCHEMATIC dimmer triac dimmer microcontroller with zero crossing c light dimmer working circuit using triac conrad DIMMER BT136 Zilog dimmer equivalent for TRIAC BT136
triac BT 24

Abstract: triacs bt 138 TRIAC 138 triac BT 138 BT 138 bt138 triac BT 4 400 BT138-500 TRIAC TAG 90 triac BT 24 600
Text: N AMFR PHILIPS/DISCRETE b«ÌE T> bbsg'oi DD272n no hapx BT 138 SERIES X TRIACS , Respective Manufacturer I I N AMER PHILIPS/DISCRETE BT 138 SLKItb b^E T> bbSB^l 0D27HH0 'iOH MAPXl A , VDSM VDRM VDWM 'T(RMS) max-'TRM max- ■tsm 'tsm l2t BT 138- -500 600 700 800 max. 500* 600* 700 , , but the triac may switch into the on-state. The rate of rise of on-state current should not exceed 15 , Respective Manufacturer N AMER PHILIPS/DISCRETE BT 138 SLKItb blE » (^53^31 DD27252 70S «APX JL vT


OCR Scan
PDF DD272n bt138-500 220AB BT138 BT138F triac BT 24 triacs bt 138 TRIAC 138 triac BT 138 BT 138 triac BT 4 400 TRIAC TAG 90 triac BT 24 600
50HZ oscillator sinus

Abstract: triac BT 408 DIMMER BT136 TRIAC BT 136 BT136 testing BT136 SCHEMATIC CIRCUIT triac dimmer microcontroller with zero crossing c BT136 application note BT 136 TRIAC schematic diagram of remote controlled light dimmer
Text: power setting for the load is controlled by a logiclevel triac (for example, BT 136/800 E). The gate of the triac is decoupled with a 220nF/16V capacitor, and the gate current is limited by a 1k¾ resistor , triac is ignited in the T2+G­ and T2­G­ quadrants. It is important that the triac terminal 1 is , mandatory time count to ignite the triac on the correct phase angle. A lower value for variable phase_angle , timer1irq_count=0 timer1irq_count= timer1irq_count +1 Ignite triac Yes Correct phase angle? No


Original
PDF Z86E02 Z86E02 512-byte Z86E02. AN001600-Z8X0299 50HZ oscillator sinus triac BT 408 DIMMER BT136 TRIAC BT 136 BT136 testing BT136 SCHEMATIC CIRCUIT triac dimmer microcontroller with zero crossing c BT136 application note BT 136 TRIAC schematic diagram of remote controlled light dimmer
BTi36

Abstract: TRIAC BT 136 triac BT 06 400 triac BT 06 600 BT 136 TRIAC TRIAC BY 136 BT136 triac BT 06 700 PH 600D B 134 bt 136
Text: ) max- BT 136- -500 600 700 800 max. 500 600 700 800 'tsm 'tsm max. max. 25 30 V A A MECHANICAL DATA Fig , . ^Although not recommended, off-state voltages up to 800 V may be applied without damage, but the triac may , will not trigger any device; Tj = 120 °C; gate open circuit BT 136 series dVD/dt < 100 V/fis BT 136 series G dVD/dt < 200 V/jis BT 136 series F dVD/dt < 50 V/m s BT136 series E dVD/dt typ. 50 V , current {!(.) Latching current (![_); Vq = 12 V T2+ G+ BT136 series BT 136 series G BT136 series F BT136


OCR Scan
PDF 00bE23a BT136 BT136F d8573 BTi36 TRIAC BT 136 triac BT 06 400 triac BT 06 600 BT 136 TRIAC TRIAC BY 136 triac BT 06 700 PH 600D B 134 bt 136
triac BT 317

Abstract: BT 317 triac triac BT 06 600 triac BT 24 BT134 BT134-500D triac BT 06 400 triac BT 06 700 triacs BT 134 w triac BT 134
Text: N AMER PHILIPS/DISCRETE b^E T> m bbSa^Bl 002715b 1Ô7 HIAPX BT 134 SERIES y v. TRIACS , damage, but the triac may switch into the on-state. The rate of rise of on-state current should not , 1.8 A/ms; ¡T BT 134 series dVcom/dt typ. 10 V/fis BT 134 series G dVcom/dt < 10 V/jus BT 134 series F dVCom/dt typ. 10 V/a-s Off-state , the terminals does not exceed 125 °C. During these overload conditions the triac may lose control


OCR Scan
PDF 002715b bt134-500 BT134G BT134 00271b5 BT134F triac BT 317 BT 317 triac triac BT 06 600 triac BT 24 BT134-500D triac BT 06 400 triac BT 06 700 triacs BT 134 w triac BT 134
2010 - trailing edge dimmer mosfet diac

Abstract: LNK457DG Leviton 6615 Leviton tape 3m 9448 SNX-R1536 3m 9448 EE16 pc40 smd transistor 43t RM34DMA
Text: and end user experience o >100:1 dimming range even with low cost leading edge TRIAC dimmers o Clean , -3-2 harmonics contents Power Integrations 5245 Hellyer Avenue, San Jose, CA 95138 USA. Tel: +1 408 414 9200 Fax: +1 408 414 9201 www.powerint.com RDR-251 LNK457D (LED Dimmable Power Supply) 20 , Integrations, Inc. Tel: +1 408 414 9200 Fax: +1 408 414 9201 www.powerint.com Page 2 of 58 20 , .40 11.1.3 115 V TRIAC in Series with AC Input .40


Original
PDF LNK457DG RDR-251 trailing edge dimmer mosfet diac LNK457DG Leviton 6615 Leviton tape 3m 9448 SNX-R1536 3m 9448 EE16 pc40 smd transistor 43t RM34DMA
2010 - LNK405EG

Abstract: Zierick PN 190 507-1181 DER-192 TRK-24 diode 1n4007 melf smd linkswitch PH FMMT560TA 4NSLWS optocoupler 8178
Text: count, non-isolated LED driver Configurable for TRIAC dimming or non-dimming configurations PF >0.9 , shutdown Power Integrations 5245 Hellyer Avenue, San Jose, CA 95138 USA. Tel: +1 408 414 9200 Fax: +1 408 414 9201 www.powerint.com DER-192 12 W PAR38 BUCK LED Driver Using LNK405EG 09 , Integrations Tel: +1 408 414 9200 Fax: +1 408 414 9201 www.powerint.com Page 2 of 54 09-Jun-10 DER , 4.2 TRIAC Dimmable, Power Factor Corrected Buck LED Driver . 10 4.3


Original
PDF LNK405EG DER-192 LNK405EG Zierick PN 190 507-1181 DER-192 TRK-24 diode 1n4007 melf smd linkswitch PH FMMT560TA 4NSLWS optocoupler 8178
triac BT 137

Abstract: triac BT 137 800 philips d8614 BT 137 triac triac bt 135 bt 137 BT137 triac BT 137 600 triac BT 06 600 TRIAC TAG 91
Text: PHILIPS INTERNATIONAL bSE D 711GÖ2L, D0b2Ebl 27b HIPHIN BT 137 SERIES s V TRIACS Glass-passivated , BT 137 -500 600 700 800 max. 500 600 700 800 max. max. max. 55 60 V A A MECHANICAL DATA Fig.1 TOâ , either direction) BT 137-500 600 700 800 Non-repetitive peak off-state voltage (t < 10 ms)t VDSM max , without damage, but the triac may switch into the on-state. The rate of rise of on-state current should , the terminals does not exceed 125 °C. During these overload conditions the triac may lose control


OCR Scan
PDF 00b2271 BT137 M1Q41 BT137F D8573 M81-1647/1 triac BT 137 triac BT 137 800 philips d8614 BT 137 triac triac bt 135 bt 137 triac BT 137 600 triac BT 06 600 TRIAC TAG 91
2002 - TRIAC BTA 28

Abstract: TRIAC BTB T25 ac motor triac bta25 triac bt 151 triac BTA 32 600 triac TOP3 25a 800V triac bt 24 600v triac BT 408 TRIAC BTB 16 600 BW TRIAC BTA 4000
Text: INFORMATION BT A 24 - (RG) TRIAC SERIES INSULATION: A: insulated B: non insulated VOLTAGE , either in through-hole of surface and T25 mount packages, the BTA/BTB24-25-26 triac series is suitable , in TOP3 3/9 BTA/BTB24, BTA25, BTA26 and T25 Series T 25 35 - 600 G (-TR) TRIAC , 1.45 14.35 0.5 2.7 15.8 20.4 15.1 5.4 3.4 4.08 1.20 Max. Typ. 0.173 0.057 0.565


Original
PDF BTA/BTB24, BTA25, BTA26 O-220AB BTB24) TRIAC BTA 28 TRIAC BTB T25 ac motor triac bta25 triac bt 151 triac BTA 32 600 triac TOP3 25a 800V triac bt 24 600v triac BT 408 TRIAC BTB 16 600 BW TRIAC BTA 4000
1997 - triac BT 140

Abstract: 2kw TRIAC control triac burst control ic TRIAC BT 139 TRIAC 226 a triac 226 triac burst firing circuit triac applications circuit diagram BT 140 triac triac switch circuits
Text: requirement the value of tp can be calculated. eg. for triac BT 139 (data sheet 2488) worst case holding , number 307-985 A zero voltage switch IC offering symmetrical burst control of an external triac , triac firing under noisy mains conditions q Low external component count q Symmetrical burst control , °C unless otherwise stated Parameter Pin 3 voltage Supply current, I2 Rp resistance range Triac gate , Total power dissipation Conditions I = 16mA Excluding triac trigger pulse and pin 5 output total


Original
PDF
triac tag 87

Abstract: TRIAC BT 136 BT136 working triac bt136 triac bt 135 BT 136 TRIAC TRIAC BT 136-500D TO220 D8384 bt136 triac triac BT 06 400
Text: - *Although not recommended, off-state voltages up to 800 V may be applied without damage, but the triac may , current (l|_j) Latching current (l[_); Vq = 12 V T2+ G+ BT136 series BT 136 series G BT136 series F BT 136 series E BT 136—500D/600D GT > 35 H < 15 L <20 GT > 50 H < 30 L <30 GT H L > 25 < 15 < 20 GT H L > 10 , temperature of the terminals does not exceed 125 °C. During these overload conditions the triac may lose , based on sinusoidal currents (f = 50 Hz); Tj = 120 °C prior to surge. The triac may temporarily lose


OCR Scan
PDF 711Da2b 0Db523Ã BT136 BT136-500 M1625 BT136G 711002b 00b224Ã M1644 triac tag 87 TRIAC BT 136 working triac bt136 triac bt 135 BT 136 TRIAC TRIAC BT 136-500D TO220 D8384 bt136 triac triac BT 06 400
TRIAC BT 136

Abstract: BT 136 TRIAC BT136 working triac bt136 temperature control by triac BT136 triac bt 135 bt136 triac TRIAC TAG 90 BT136 motor BT136 application note
Text: - *Although not recommended, off-state voltages up to 800 V may be applied without damage, but the triac may , V T2+ G+ BT136 series BT 136 series G BT136 series F BT 136 series E BT 136—500D/600D GT , the temperature of the terminals does not exceed 125 °C. During these overload conditions the triac , . on-state current based on sinusoidal currents (f = 50 Hz); Tj = 120 °C prior to surge. The triac may , IPHIN M 1 643 Fig.8 Typical commutation dV/dt for BT136 series versus Tj. The triac should commutate


OCR Scan
PDF 711Da2b 00bS23Ã BT136 BT136-500 711005b 00b224Ã M1644 BT136F D8573 TRIAC BT 136 BT 136 TRIAC working triac bt136 temperature control by triac BT136 triac bt 135 bt136 triac TRIAC TAG 90 BT136 motor BT136 application note
2000 - triac BT 24

Abstract: TRIAC BTA 28 TRIAC BTA 16 -600 triac TOP3 25a 800V TRIAC BTA24 T25G TRIAC BTA 20 600 BW BTB24 TRIAC BT 127 BTA25
Text: insulated TO-220AB package ORDERING INFORMATION BT A 24 - 600 BW TRIAC SERIES INSULATION , Available either in through-hole of surface and T25 mount packages, the BTA/BTB24-25-26 triac series is , ) TRIAC SERIES PACKAGE: G: D2PAK CURRENT: 25A VOLTAGE: 600: 600V 800: 800V PACKING MODE , 4.08 1.20 Max. Typ. 0.173 0.057 0.565 0.020 0.106 0.622 0.815 0.594 0.213 0.134


Original
PDF BTA/BTB24, BTA25, BTA26 O-220AB BTB24) triac BT 24 TRIAC BTA 28 TRIAC BTA 16 -600 triac TOP3 25a 800V TRIAC BTA24 T25G TRIAC BTA 20 600 BW BTB24 TRIAC BT 127 BTA25
2002 - triac BT 408

Abstract: triac bt 24 600v TRIAC BTA 4000 triac bt 151 triac TOP3 25a 800V TRIAC BTA 28 triac BTA 32 600 TRIAC btb24 RD91 triac TRIAC BTB T25
Text: Snubberless Standard Snubberless Snubberless Snubberless ORDERING INFORMATION BT A 24 TRIAC SERIES , , the BTA/BTB24-25-26 triac series is suitable for general purpose AC power switching. They can be used , Series T 25 35 TRIAC SERIES CURRENT: 25A - 600 G PACKAGE: 2 G: D PAK (-TR) VOLTAGE: 600 , 1.45 14.35 0.5 2.7 15.8 20.4 15.1 5.4 3.4 4.08 1.20 4.60 Typ. Max. 4.6 1.55 15.60 0.7 2.9 16.5 21.1


Original
PDF BTA/BTB24, BTA25, BTA26 BTA/BTB24-25-26 triac BT 408 triac bt 24 600v TRIAC BTA 4000 triac bt 151 triac TOP3 25a 800V TRIAC BTA 28 triac BTA 32 600 TRIAC btb24 RD91 triac TRIAC BTB T25
2013 - 1 kilo ohm resistor specifications

Abstract: RESISTOR 50 KILO OHM 2.2 kilo ohm resistor specifications
Text: GuardSwitch Series 300 Switches 301- BT and 303- BT Installation Sheet Figure 1: Dimensions Description The 301- BT Series 300 DPST safety interlock switch is designed for use with safety monitored relays or monitored circuits. To achieve the optimum Series 300 defeat resistant feature of the 301- BT , The housing of the 300- BT must be connected to the PE (Primary Earth) ground circuit via a lock , or nuts. See ordering information for details. Set range at 20 mega ohms (switches with triac


Original
PDF 301-BT 303-BT 301-BT, 73/23/EEC) EN60204-1 EN292 EN954-1 EN55081-2 EN50082-2 1 kilo ohm resistor specifications RESISTOR 50 KILO OHM 2.2 kilo ohm resistor specifications
2006 - triac bta26

Abstract: triac BT 151 triac BT 06 400 triac BT 130 TRIAC BTA 28 BTA25-xxxxxRG T25 Series
Text: (BTA and BTB series) BT A 24 - 600 BW RG Triac series Insulation A = insulated B = non insulated , , BTA25, BTA26 and T25 triac series is suitable for general purpose AC switching. They can be used as an , Figure 13: Ordering Information Scheme (T25 series) T 25 35 - 600 G (-TR) Triac series Current 25 = 25A , . 4.6 Min. 0.173 4.4 1.45 14.35 0.5 2.7 15.8 20.4 15.1 5.4 3.4 4.08 1.20 4.60 Inches Typ. Max. 0.181


Original
PDF BTA24, BTB24, BTA25, BTA26 triac bta26 triac BT 151 triac BT 06 400 triac BT 130 TRIAC BTA 28 BTA25-xxxxxRG T25 Series
triac bt 135

Abstract: triac BT 140 TAG 84 triac TRIAC BT 139 BT 139 F applications note bt 139 BT 140 triac BT139 triac BT 147 triac BT 24
Text: current 'T(RMS) Non-repetitive peak on-state current at 50 Hz ITS(V] at 60 Hz lTSM BT 139- -500 600 700 , (in either direction) BT 139- -500 600 700 800 Non-repetitive peak off-state voltage (t< 10 ms) VDSM , recommended, off-state voltages up to 800 V may be applied without damage, but the triac may switch into the , ; = 120 °C; gate open circuit 1.6 bt 139 series dVD/dt < 100 V/MS bt139 series G dVD/dt < 200 V/MS , temperature of the terminals does not exceed 125 °C. During these overload conditions the triac may lose


OCR Scan
PDF 711002b 00L23Q7 BT139 220AB triac bt 135 triac BT 140 TAG 84 triac TRIAC BT 139 BT 139 F applications note bt 139 BT 140 triac triac BT 147 triac BT 24
2002 - triac BTA 32 600

Abstract: TRIAC BTA 28 triac BTA 32 triac bta26 triac BTA 140 triac bt 160 600v TRIAC BTA 4000 TRIAC BTA 20 600 BW TRIAC BTB 16 400 BW BTA 600 12 triac
Text: insulated TO-220AB package ORDERING INFORMATION BT A 24 - 600 BW (RG) TRIAC SERIES , either in through-hole of surface and T25 mount packages, the BTA/BTB24-25-26 triac series is suitable , T 25 35 - 600 G (-TR) TRIAC SERIES PACKAGE: G: D2PAK CURRENT: 25A VOLTAGE: 600 , 4.08 1.20 Max. Typ. 0.173 0.057 0.565 0.020 0.106 0.622 0.815 0.594 0.213 0.134


Original
PDF BTA/BTB24, BTA25, BTA26 O-220AB BTB24) triac BTA 32 600 TRIAC BTA 28 triac BTA 32 triac bta26 triac BTA 140 triac bt 160 600v TRIAC BTA 4000 TRIAC BTA 20 600 BW TRIAC BTB 16 400 BW BTA 600 12 triac
2010 - LNK406

Abstract: LNK406EG snx-R1523 Philips CSV-RM8 bobbin Lutron RDR-194 XH004186 Leviton dolph transformer rm8
Text: Title Reference Design Report for a High Efficiency (85%), High Power Factor (>0.9) TRIAC , performance and end user experience o TRIAC dimmer compatible (including low cost leading edge type) No , , CA 95138 USA. Tel: +1 408 414 9200 Fax: +1 408 414 9201 www.powerint.com RDR-194 14 W LED , ://www.powerint.com/ip.htm>. Power Integrations, Inc. Tel: +1 408 414 9200 Fax: +1 408 414 9201 www.powerint.com Page , .11 4.5 TRIAC Phase Dimming Control Compatibility


Original
PDF LNK406EG LNK406 LNK406EG snx-R1523 Philips CSV-RM8 bobbin Lutron RDR-194 XH004186 Leviton dolph transformer rm8
2001 - TRIAC BTA 28

Abstract: triac bt 151 TRIAC BTB T25 TRIAC BTB 16 300 BW triac bt 160 600v TRIAC BTB 24 600 BW triacs bt 16 600v RD91 BTB24 BTA25
Text: either in through-hole of surface and T25 mount packages, the BTA/BTB24-25-26 triac series is suitable , /BTB24-xxxBW X BTA/BTB24-xxxCW BTB: Non insulated TO-220AB package ORDERING INFORMATION BT A 24 - 600 BW TRIAC SERIES INSULATION: A: insulated B: non insulated VOLTAGE: 600: 600V , Series T 25 35 - 600 G (-TR) TRIAC SERIES PACKAGE: 2 G: D PAK CURRENT: 25A , 1.45 14.35 0.5 2.7 15.8 20.4 15.1 5.4 3.4 4.08 1.20 Max. Typ. 0.173 0.057 0.565


Original
PDF BTA/BTB24, BTA25, BTA26 O-220AB BTB24) TRIAC BTA 28 triac bt 151 TRIAC BTB T25 TRIAC BTB 16 300 BW triac bt 160 600v TRIAC BTB 24 600 BW triacs bt 16 600v RD91 BTB24 BTA25
1993 - voltage regulator using triac

Abstract: TDA2088 220v ac to 110v dc regulator USER TRIAC 220v DC MOTOR SPEED CONTROL USING ic regulator ac motor speed control circuit diagram with triac gate firing circuit ac voltage regulator triac conduction angle control ic triac gate control circuits triac phase control motor
Text: . Low supply current consumptlon. Negative triac firing pulses. Guaranteed minimum 100mA trlac drive , triac gate current for 50 µ s pulse SHUNT VOLTAGE REGULATOR Pin 14 Regulating voltage Voltage monitor , TDA2088 ABSOLUTE MAXIMUM RATINGS ELECTRICAL Triac gate voltage pin 12 Repetitive peak input current , functions and triac gate drive pulses are inhibited until there is sufficient supply voltage across the , triac and correct linear operation of the control system is maintained. Negative Triac Gate Firing


Original
PDF TDA2088 DS3849 TDA2088 100mA voltage regulator using triac 220v ac to 110v dc regulator USER TRIAC 220v DC MOTOR SPEED CONTROL USING ic regulator ac motor speed control circuit diagram with triac gate firing circuit ac voltage regulator triac conduction angle control ic triac gate control circuits triac phase control motor
2005 - TRIAC BTB 24 600 BW

Abstract: TRIAC BTA24 TRIAC BTB 16 600 BW TRIAC BTB 16 300 BW
Text: and BTB series BT A 24 - 600 BW RG Triac series Insulation A = insulated B = non insulated , through-hole or surface-mount packages, the BTA24, BTB24, BTA25, BTA26 and T25 triac series is suitable for , Tube Figure 13. T25 series T 25 35 - 600 G (-TR) Triac series Current 25 = 25A Sensitivity 35 , 3.65 0.134 0.144 ØL 4.08 4.17 0.161 0.164 P ØL 4.6 B B 4.4 C R


Original
PDF BTA24, BTB24, BTA25, BTA26 O-220AB BTB24) O-220AB BTA24) TRIAC BTB 24 600 BW TRIAC BTA24 TRIAC BTB 16 600 BW TRIAC BTB 16 300 BW
Supplyframe Tracking Pixel