The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
LT1125CJ8 Linear Technology IC OP-AMP, 140 uV OFFSET-MAX, 12.5 MHz BAND WIDTH, CDIP14, Operational Amplifier
LT1127CJ14 Linear Technology IC QUAD OP-AMP, 140 uV OFFSET-MAX, 45 MHz BAND WIDTH, CDIP14, Operational Amplifier
LT1127CN14 Linear Technology IC QUAD OP-AMP, 140 uV OFFSET-MAX, 45 MHz BAND WIDTH, PDIP14, Operational Amplifier
LT1125CJ14 Linear Technology IC QUAD OP-AMP, 140 uV OFFSET-MAX, 12.5 MHz BAND WIDTH, CDIP14, Operational Amplifier
LT1127CS16 Linear Technology IC QUAD OP-AMP, 140 uV OFFSET-MAX, 45 MHz BAND WIDTH, PDSO16, Operational Amplifier
LT1127MJ14 Linear Technology IC QUAD OP-AMP, 140 uV OFFSET-MAX, 45 MHz BAND WIDTH, CDIP14, Operational Amplifier

triac BT 140 Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
triac bt 135

Abstract: triac BT 140 TAG 84 triac TRIAC BT 139 BT 139 F applications note bt 139 BT 140 triac BT139 triac BT 147 triac BT 24
Text: current 'T(RMS) Non-repetitive peak on-state current at 50 Hz ITS(V] at 60 Hz lTSM BT 139- -500 600 700 800 max. 500 600 700 800 max. max. max. 16 140 150 V A A A MECHANICAL DATA Fig. 1 TOâ , (in either direction) BT 139- -500 600 700 800 Non-repetitive peak off-state voltage (t< 10 ms) VDSM , operation IT(RMS) max-'TRM max- >TSM max-ITSM max' l2t max. dly/dt max. pG(AV) max- PQM max- Tstg 16 140 140 , recommended, off-state voltages up to 800 V may be applied without damage, but the triac may switch into the


OCR Scan
PDF 711002b 00L23Q7 BT139 220AB triac bt 135 triac BT 140 TAG 84 triac TRIAC BT 139 BT 139 F applications note bt 139 BT 140 triac triac BT 147 triac BT 24
1997 - triac BT 140

Abstract: 2kw TRIAC control triac burst control ic TRIAC BT 139 TRIAC 226 a triac 226 triac burst firing circuit triac applications circuit diagram BT 140 triac triac switch circuits
Text: requirement the value of tp can be calculated. eg. for triac BT 139 (data sheet 2488) worst case holding , number 307-985 A zero voltage switch IC offering symmetrical burst control of an external triac , triac firing under noisy mains conditions q Low external component count q Symmetrical burst control , °C unless otherwise stated Parameter Pin 3 voltage Supply current, I2 Rp resistance range Triac gate , Total power dissipation Conditions I = 16mA Excluding triac trigger pulse and pin 5 output total


Original
PDF
2008 - triacs BTA

Abstract: BC557 in smd package triac snubber ac motor SM1L43 triacs bt 12 Triac ACS108 controlling heater with triac washing machine drain valve types universal motor speed control wash ac motor control with triac
Text: can pose a particular challenge. NXP's BTA208X-1000C triac offers best-in-class performance in this , the AC mains supply. Each triac 's operation has to be mutually exclusive, to avoid uncontrolled , sinusoidal voltage (higher than the mains supply voltage), and the triac needs to be able to block the , inductor is not necessary The NXP BTA208X-1000C is the only three-quadrant Hi-Com triac to guarantee a , , motor speed varies widely. A triac is typically used to control the speed, via phase-control of the


Original
PDF
2007 - 1M preset

Abstract: triac bt 13 h preset variable resistor 1m triac analog control for inductive loads 1M preset, horizontal L56R BT139 motor speed control washing machine drain valve types induction heater microcontroller 100n N 250v X2
Text: and surface-mount options G+ The simple, reliable and inexpensive triac is used to control , Eliminates need for snubber circuit High dVD/dt Triac voltage Inductive load Three-quadrant triac 100 carbon composition resistor 100nF 250V AC SNUBBER NOT REQUIRED Ñ igher dVcom/dt , commutation - Eliminates need for snubber circuit Triac voltage High dVCOM/dt Inductive load Three-quadrant triac 100 carbon composition resistor 100nF 250V AC Load Current SNUBBER NOT


Original
PDF BTA225 BTA225B 1M preset triac bt 13 h preset variable resistor 1m triac analog control for inductive loads 1M preset, horizontal L56R BT139 motor speed control washing machine drain valve types induction heater microcontroller 100n N 250v X2
TAG 84 triac

Abstract: triac BT 140 TRIAC BT 139 TRIAC TAG 90 bt139 BT139G TRIAC TAG 96 bt139 Application M1646 triac BT 147
Text: €”220AB VDRM 't(rms) 'tsm 'tsm BT139- -500 600 700 800 max. 500 600 700 800 max. max. 16 140 150 V A , ) BT 139- -500 600 700 800 Non-repetitive peak off-state voltage (t< 10 ms) VDSM max. 500* 600* 700 , ¡ max. 16 140 140 150 95 30 0.5 5 -40 to+125 120 110 A A A A A2s A/ais W W OC °C °C *Although not recommended, off-state voltages up to 800 V may be applied without damage, but the triac may switch into the on-state. The rate of rise of on-state current should not exceed 15 A//us. 140 March


OCR Scan
PDF 711002b BT139 220AB BT139- TAG 84 triac triac BT 140 TRIAC BT 139 TRIAC TAG 90 BT139G TRIAC TAG 96 bt139 Application M1646 triac BT 147
triac BT 24

Abstract: triacs bt 138 TRIAC 138 triac BT 138 BT 138 bt138 triac BT 4 400 BT138-500 TRIAC TAG 90 triac BT 24 600
Text: N AMFR PHILIPS/DISCRETE b«ÌE T> bbsg'oi DD272n no hapx BT 138 SERIES X TRIACS , Respective Manufacturer I I N AMER PHILIPS/DISCRETE BT 138 SLKItb b^E T> bbSB^l 0D27HH0 'iOH MAPXl A , VDSM VDRM VDWM 'T(RMS) max-'TRM max- ■tsm 'tsm l2t BT 138- -500 600 700 800 max. 500* 600* 700 , , but the triac may switch into the on-state. The rate of rise of on-state current should not exceed 15 , Respective Manufacturer N AMER PHILIPS/DISCRETE BT 138 SLKItb blE » (^53^31 DD27252 70S «APX JL vT


OCR Scan
PDF DD272n bt138-500 220AB BT138 BT138F triac BT 24 triacs bt 138 TRIAC 138 triac BT 138 BT 138 triac BT 4 400 TRIAC TAG 90 triac BT 24 600
1995 - triac BT 140

Abstract: triac burst control ic 2kw TRIAC control ac voltage stabiliser circuit diagram ramp generator triac BT 139 TRIAC 226 a stabiliser circuit diagram triac applications circuit diagram 443A
Text: requirement the value of tp can be calculated. eg. for triac BT 139 (data sheet 2488) worst case holding , number 307-985 A zero voltage switch IC offering symmetrical burst control of an external triac , triac firing under noisy mains conditions q Low external component count q Symmetrical burst control , °C unless otherwise stated Parameter Pin 3 voltage Supply current, I2 Rp resistance range Triac gate , Total power dissipation Conditions I = 16mA Excluding triac trigger pulse and pin 5 output total


Original
PDF
BTi36

Abstract: TRIAC BT 136 triac BT 06 400 triac BT 06 600 BT 136 TRIAC TRIAC BY 136 BT136 triac BT 06 700 PH 600D B 134 bt 136
Text: ) max- BT 136- -500 600 700 800 max. 500 600 700 800 'tsm 'tsm max. max. 25 30 V A A MECHANICAL DATA Fig , . ^Although not recommended, off-state voltages up to 800 V may be applied without damage, but the triac may , will not trigger any device; Tj = 120 °C; gate open circuit BT 136 series dVD/dt < 100 V/fis BT 136 series G dVD/dt < 200 V/jis BT 136 series F dVD/dt < 50 V/m s BT136 series E dVD/dt typ. 50 V , current {!(.) Latching current (![_); Vq = 12 V T2+ G+ BT136 series BT 136 series G BT136 series F BT136


OCR Scan
PDF 00bE23a BT136 BT136F d8573 BTi36 TRIAC BT 136 triac BT 06 400 triac BT 06 600 BT 136 TRIAC TRIAC BY 136 triac BT 06 700 PH 600D B 134 bt 136
1984 - 2kw TRIAC control

Abstract: TRIAC 226 d triac BT 140 triac burst firing circuit Automatic Voltage stabilizer 5 kw J7770 zero detector ic of ac mains triac BT 139 triac burst control ic Peak level meter ic
Text: triac trigger pulse and pin 5 output - -7.2 mA R resistance range total 18 - 140 kW p Triac gate drive , can be calculated. p eg. for triac BT 139 (see data sheet 2488) worst case holding current I = 30mA , . offering symmetrical burst Features control of an external triac . Ideal for power control in l High immunity against spurious triac firing many heating applications. under noisy mains conditions l Low , to the 7.0V tive or low power resistive, the triac load current series stabilizer which feeds the


Original
PDF J7770 2kw TRIAC control TRIAC 226 d triac BT 140 triac burst firing circuit Automatic Voltage stabilizer 5 kw J7770 zero detector ic of ac mains triac BT 139 triac burst control ic Peak level meter ic
triac BT 317

Abstract: BT 317 triac triac BT 06 600 triac BT 24 BT134 BT134-500D triac BT 06 400 triac BT 06 700 triacs BT 134 w triac BT 134
Text: N AMER PHILIPS/DISCRETE b^E T> m bbSa^Bl 002715b 1Ô7 HIAPX BT 134 SERIES y v. TRIACS , damage, but the triac may switch into the on-state. The rate of rise of on-state current should not , 1.8 A/ms; ¡T BT 134 series dVcom/dt typ. 10 V/fis BT 134 series G dVcom/dt < 10 V/jus BT 134 series F dVCom/dt typ. 10 V/a-s Off-state , the terminals does not exceed 125 °C. During these overload conditions the triac may lose control


OCR Scan
PDF 002715b bt134-500 BT134G BT134 00271b5 BT134F triac BT 317 BT 317 triac triac BT 06 600 triac BT 24 BT134-500D triac BT 06 400 triac BT 06 700 triacs BT 134 w triac BT 134
triac BT 408

Abstract: No abstract text available
Text: BT A2 6 SERI ES ST AN DARD 2 6 A T RI ACs ï®ï€ MAIN FEATURES Symbol Value Unit IT , DESCRIPTION Available either in through-hole or surface and T25 mount packages, the BTA/BTB 24-25-26 triac , temperature range V -40 to+125 38 H SiN BT A2 6 SERI ES ï®ï€ STATIC CHARACTERISTICS Tj , -220AB Insulated 39 Unit 60 /W /W H SiN BT A2 6 SERI ES PERFORM AN CE CU RV ES ï€ TO , sinusoidal pulse with width tp<10ms, and corresponding value of I2t 40 H SiN BT A2 6 SERI ES


Original
PDF
2014 - Not Available

Abstract: No abstract text available
Text: occur. This "series BT " triac will commutate the full RMS current at the maximum rated junction , D2 PA K BTA316B-600BT 3Q Hi-Com Triac 6 August 2014 Product data sheet 1. General description Planar passivated high commutation three quadrant triac in a SOT404 (D2PAK) surface mountable , current tp = 20 ms; Fig. 4; Fig. 5 - - 140 A Tj junction temperature - - 150 , BTA316B-600BT NXP Semiconductors 3Q Hi-Com Triac Symbol Parameter Conditions Min Typ


Original
PDF BTA316B-600BT OT404
triac BT 137

Abstract: triac BT 137 800 philips d8614 BT 137 triac triac bt 135 bt 137 BT137 triac BT 137 600 triac BT 06 600 TRIAC TAG 91
Text: PHILIPS INTERNATIONAL bSE D 711GÖ2L, D0b2Ebl 27b HIPHIN BT 137 SERIES s V TRIACS Glass-passivated , BT 137 -500 600 700 800 max. 500 600 700 800 max. max. max. 55 60 V A A MECHANICAL DATA Fig.1 TOâ , either direction) BT 137-500 600 700 800 Non-repetitive peak off-state voltage (t < 10 ms)t VDSM max , without damage, but the triac may switch into the on-state. The rate of rise of on-state current should , the terminals does not exceed 125 °C. During these overload conditions the triac may lose control


OCR Scan
PDF 00b2271 BT137 M1Q41 BT137F D8573 M81-1647/1 triac BT 137 triac BT 137 800 philips d8614 BT 137 triac triac bt 135 bt 137 triac BT 137 600 triac BT 06 600 TRIAC TAG 91
2012 - triac BT 16 rating

Abstract: No abstract text available
Text: dynamic dV/dt and high dI/dt can occur. This "series BT " triac will commutate the full RMS current at the , D2 PA K BTA316B-600BT 3Q Hi-Com Triac Rev. 1 - 16 April 2012 Product data sheet 1. Product profile 1.1 General description Planar passivated high commutation three quadrant triac in a , 25 °C; tp = 20 ms; see Figure 4; see Figure 5 Conditions Min Typ Max 600 140 150 16 Unit V A °C A NXP Semiconductors BTA316B-600BT 3Q Hi-Com Triac Table 1. Symbol IGT Quick reference data


Original
PDF BTA316B-600BT OT404 triac BT 16 rating
2010 - Not Available

Abstract: No abstract text available
Text: . This "series BT " triac will commutate the full RMS current at the maximum rated junction temperature , BTA316-600BT 3Q Hi-Com Triac Rev. 02 — 30 November 2010 Product data sheet 1. Product profile 1.1 General description Planar passivated high commutation three quadrant triac in a SOT78 , - 140 A full sine wave; Tmb ≤ 126 ° C; see Figure 3; see Figure 1; see Figure 2 , 150 ° C - - 16 A BTA316-600BT NXP Semiconductors 3Q Hi-Com Triac Table 1


Original
PDF BTA316-600BT
triac tag 87

Abstract: TRIAC BT 136 BT136 working triac bt136 triac bt 135 BT 136 TRIAC TRIAC BT 136-500D TO220 D8384 bt136 triac triac BT 06 400
Text: - *Although not recommended, off-state voltages up to 800 V may be applied without damage, but the triac may , current (l|_j) Latching current (l[_); Vq = 12 V T2+ G+ BT136 series BT 136 series G BT136 series F BT 136 series E BT 136—500D/600D GT > 35 H < 15 L <20 GT > 50 H < 30 L <30 GT H L > 25 < 15 < 20 GT H L > 10 , temperature of the terminals does not exceed 125 °C. During these overload conditions the triac may lose , based on sinusoidal currents (f = 50 Hz); Tj = 120 °C prior to surge. The triac may temporarily lose


OCR Scan
PDF 711Da2b 0Db523Ã BT136 BT136-500 M1625 BT136G 711002b 00b224Ã M1644 triac tag 87 TRIAC BT 136 working triac bt136 triac bt 135 BT 136 TRIAC TRIAC BT 136-500D TO220 D8384 bt136 triac triac BT 06 400
TRIAC BT 136

Abstract: BT 136 TRIAC BT136 working triac bt136 temperature control by triac BT136 triac bt 135 bt136 triac TRIAC TAG 90 BT136 motor BT136 application note
Text: - *Although not recommended, off-state voltages up to 800 V may be applied without damage, but the triac may , V T2+ G+ BT136 series BT 136 series G BT136 series F BT 136 series E BT 136—500D/600D GT , the temperature of the terminals does not exceed 125 °C. During these overload conditions the triac , . on-state current based on sinusoidal currents (f = 50 Hz); Tj = 120 °C prior to surge. The triac may , IPHIN M 1 643 Fig.8 Typical commutation dV/dt for BT136 series versus Tj. The triac should commutate


OCR Scan
PDF 711Da2b 00bS23Ã BT136 BT136-500 711005b 00b224Ã M1644 BT136F D8573 TRIAC BT 136 BT 136 TRIAC working triac bt136 temperature control by triac BT136 triac bt 135 bt136 triac TRIAC TAG 90 BT136 motor BT136 application note
2013 - 1 kilo ohm resistor specifications

Abstract: RESISTOR 50 KILO OHM 2.2 kilo ohm resistor specifications
Text: GuardSwitch Series 300 Switches 301- BT and 303- BT Installation Sheet Figure 1: Dimensions Description The 301- BT Series 300 DPST safety interlock switch is designed for use with safety monitored relays or monitored circuits. To achieve the optimum Series 300 defeat resistant feature of the 301- BT , The housing of the 300- BT must be connected to the PE (Primary Earth) ground circuit via a lock , or nuts. See ordering information for details. Set range at 20 mega ohms (switches with triac


Original
PDF 301-BT 303-BT 301-BT, 73/23/EEC) EN60204-1 EN292 EN954-1 EN55081-2 EN50082-2 1 kilo ohm resistor specifications RESISTOR 50 KILO OHM 2.2 kilo ohm resistor specifications
triac BT 140

Abstract: BTB12 TRIAC BTB 12 600 B Triac BTB12 600 B
Text: /C triac family are high perfor mance glass passivated PNPN devices. These parts are suitables for , 120 140 Flg.3 : Correlation between maximum RMS power dissipation and maximum allowable , \ \ \ \ V A · C/W N A A \ Vn \ A\ I 20 \ V \ R h* O ' C/W BT \ \\ \ BT V 90 a · isS0° 7cas 3<*C \\ \ \\ \ I 40 60 80 100 120 140 110 0 10 20 3 0 4 0 5 0 6 0 7 0 8 0 9 0


OCR Scan
PDF BTA12 BTB12 E81734) BTA/BTB12 triac BT 140 TRIAC BTB 12 600 B Triac BTB12 600 B
2010 - triac BT 140

Abstract: triac BT 16 rating triac BT 06 400 triac BT 24 triac BT 12 rating BTA316 BTA316-600BT BT triac BT 140 triac
Text: . This "series BT " triac will commutate the full RMS current at the maximum rated junction temperature , BTA316-600BT 3Q Hi-Com Triac Rev. 02 - 30 November 2010 Product data sheet 1. Product profile 1.1 General description Planar passivated high commutation three quadrant triac in a SOT78 , 600 V - - 140 A - full sine wave; Tj(init) = 25 °C; tp = 20 ms; see Figure 4 , 3Q Hi-Com Triac Table 1. Symbol Quick reference data .continued Parameter Conditions


Original
PDF BTA316-600BT triac BT 140 triac BT 16 rating triac BT 06 400 triac BT 24 triac BT 12 rating BTA316 BTA316-600BT BT triac BT 140 triac
2014 - Not Available

Abstract: No abstract text available
Text: TO -2 20A B BTA316-600BT 3Q Hi-Com Triac 5 August 2014 Product data sheet 1. General description Planar passivated high commutation three quadrant triac in a SOT78 plastic package intended for use in circuits where high static and dynamic dV/dt and high dI/dt can occur. This "series BT " triac will commutate the full RMS current at the maximum rated junction temperature without the aid of , 140 A Tj junction temperature - - 150 °C IT(RMS) RMS on-state current -


Original
PDF BTA316-600BT
2012 - triac BT 24

Abstract: triac BT 41 BTA420-800BT
Text: BTA420-800BT 3Q Hi-Com Triac 27 December 2012 Product data sheet 1. General description Planar passivated high commutation three quadrant triac in a SOT78 (TO-220AB) plastic package intended for use in circuits where high static and dynamic dV/dt and high dI/ dt can occur. This "series BT " triac will commutate the full RMS current at the maximum rated junction temperature (Tj(max) = 150 °C , Semiconductors BTA420-800BT 3Q Hi-Com Triac Symbol IGT Parameter gate trigger current Conditions VD


Original
PDF BTA420-800BT O-220AB) triac BT 24 triac BT 41 BTA420-800BT
2005 - triac BTA 32 600

Abstract: circuit triac btb16 TRIAC BTA 02 TRIAC BTa 18 600 B BTA16
Text: -220AB insulated BTA16 Features ■Medium current Triac ■Low thermal resistance with clip bonding , mΩ 100 160 140 Tj = Tj max. t=20ms 120 One cycle Non repetitive Tj initial , 0 20 40 60 80 100 120 140 Figure 10. Relative variation of critical rate of , BTA16, BTB16 T1610, T1635 Figure 12. Ordering information scheme (BTA16 and BTB16 series) BT A 16 - 600 BW RG TRIAC series Insulation A = insulated B = non insulated Current 16 = 16 A Voltage


Original
PDF BTA16, BTB16 T1610, T1635 O-220AB BTA16 UL1557 2002/95/EC) triac BTA 32 600 circuit triac btb16 TRIAC BTA 02 TRIAC BTa 18 600 B BTA16
2014 - triac BT 113

Abstract: No abstract text available
Text: "series BT " triac will commutate the full RMS current at the maximum rated junction temperature without , TO -2 20A B BTA225-600BT 3Q Hi-Com Triac 6 August 2014 Product data sheet 1. General description Planar passivated high commutation three quadrant triac in a SOT78 (TO-220AB) plastic , -600BT NXP Semiconductors 3Q Hi-Com Triac Symbol Parameter Conditions Min Typ Max Unit , Semiconductors 3Q Hi-Com Triac 7. Limiting values Table 4. Limiting values In accordance with the


Original
PDF BTA225-600BT O-220AB) triac BT 113
2014 - Not Available

Abstract: No abstract text available
Text: high dI/dt can occur. This "series BT " triac will commutate the full RMS current at the maximum rated , TO -2 20A B BTA420Y-800BT 3Q Hi-Com Triac 10 June 2014 Product data sheet 1. General description Planar passivated high commutation three quadrant triac in a SOT78D (TO , -800BT NXP Semiconductors 3Q Hi-Com Triac Symbol Parameter Conditions Min Typ Max Unit , Semiconductors N.V. 2014. All rights reserved 2 / 14 BTA420Y-800BT NXP Semiconductors 3Q Hi-Com Triac


Original
PDF BTA420Y-800BT OT78D O-220AB)
Supplyframe Tracking Pixel