The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
LT3439EFE#TRPBF Linear Technology LT3439 - Slew Rate Controlled Ultralow Noise 1A Isolated DC/DC Transformer Driver; Package: TSSOP; Pins: 16; Temperature Range: -40°C to 85°C
LT3439EFE#PBF Linear Technology LT3439 - Slew Rate Controlled Ultralow Noise 1A Isolated DC/DC Transformer Driver; Package: TSSOP; Pins: 16; Temperature Range: -40°C to 85°C
LT3439EFE Linear Technology LT3439 - Slew Rate Controlled Ultralow Noise 1A Isolated DC/DC Transformer Driver; Package: TSSOP; Pins: 16; Temperature Range: -40°C to 85°C
LT3439EFE#TR Linear Technology LT3439 - Slew Rate Controlled Ultralow Noise 1A Isolated DC/DC Transformer Driver; Package: TSSOP; Pins: 16; Temperature Range: -40°C to 85°C
PMP5660.1 Texas Instruments Multi-Transformer 2x25V (390V@192mA)
PMP5660.2 Texas Instruments Multi-Transformer 2x25V (50V@700mA)

transformer EC28 Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
2014 - dimmer LED

Abstract: lutron light dimmer halogen dimmer
Text: lighting load. This device is either a magnetic low-voltage (MLV) transformer or an electronic low-voltage (ELV) transformer . Figure 1: E-I MLV (left), toroidal MLV (center) and ELV (right) transformers , wire in the coil and magnetic field losses. The output AC sinusoid waveform of a MLV transformer , MLV transformer Figure 3: Output voltage of an ELV transformer In contrast, ELV transformers , achieved by using a self-oscillating circuit which drives a high-frequency transformer , providing the


Original
PDF
2003 - sc979-03

Abstract: sc979 Signal Transformer Pulse Transformer SC97903 6 pin pulse transformer trigger transformer analog isolated Signal Transformer Transformer isolated amplifier switching transformer winding
Text: Transformer in Galvanically Isolated Systems Miroslav Oljaca, Tom Hendrick Data Acquisition Products , ADS1202 with an appropriate pulse transformer and minimal external components for isolated applications , .3 Interfacing the ADS1202 With a Pulse Transformer , .5 2.4 Transformer Connections , .10 Transformer Equivalent Circuit


Original
PDF SBAA096 ADS1202 15-bit sc979-03 sc979 Signal Transformer Pulse Transformer SC97903 6 pin pulse transformer trigger transformer analog isolated Signal Transformer Transformer isolated amplifier switching transformer winding
2003 - BU63155

Abstract: BTTC B-3067 BTTC B-3300 mlp-2005 32-PAD JESD-51-5 TST-9017 bu-63155 B-3067 B-3227
Text: recommended transformers, the transmitter typically produces 21.5Vp-p for transformer coupled outputs and , II data SHORT OR LONG STUB COUPLING ISOLATION TRANSFORMER 2 BU-63155L3 B-04/05-0 , Capacitance (Notes 1-6, 12) Threshold voltage, transformer Coupled, Measured on Stub (Note 7) Common-Mode , Transformer Coupled Across 70 Ohm, measured on Stub (Note 9) Output Noise, differential (Direct coupled) Output Offset Voltage, transformer Coupled Across 70 Ohm Rise/Fall Time TX DATA IN/TX DATA IN to TX DATA


Original
PDF BU-63155L3 MIL-STD-1553 32-Pad BU-63155 MIL-STD-1553A, 1553B, BU63155 Plas2482 BTTC B-3067 BTTC B-3300 mlp-2005 JESD-51-5 TST-9017 B-3067 B-3227
equivalent circuit autotransformer

Abstract: autotransformer design autotransformer autotransformer application transformer with primary to secondary turns ratio step down transformer winding ratio types of autotransformer AUTO TRANSFORMERS Wideband Power Transformers autotransformer winding data
Text: Document 157-1 Signal Transformer Application and Specification In the simplest sense, a transformer is two or more windings coupled by a common magnetic field. This magnetic field provides the , losses that also reduce the efficiency of the transformer but they will not be discussed in detail here , the signal transformer designer since fewer losses means that a greater amount of the signal will be transferred in an undistorted manner. Transformer have many uses, such as isolation of DC currents, voltage


Original
PDF
2007 - ei 14 transformer

Abstract: No abstract text available
Text: ® EI-162BN Split-Core Transformer Users Manual PN 2842250 June 2007 © 2007 Fluke , . Using the Split-Core Transformer . Installing Transformer around Pylon Footing . Determining Transformation Ratio Connections . Connecting Transformer to Earth Ground Tester , . Installing Transformer Around Pylon . Transformation Ratio


Original
PDF EI-162BN 1-888-99-FLUKE 1-800-36-FLUKE ei 14 transformer
2015 - inverter transformer

Abstract: No abstract text available
Text: 100kW 3*380V(±10%) IP21, Indoor Transformer XP200-HV 200kW 3*380V(±10%) IP21, Indoor Transformer XP250-HV 250kW 3*380V(±10%) IP21, Indoor Transformer XP200-HV-TL , connected to medium voltage transformer . KACO’s solar inverters are classified into 2 types : transformer type and transformerless type. Unlike transformer inverters, the transformerless inverters donâ , PROPERTIES Medium voltage transformer that is connected with transformerless solar inverter must comply


Original
PDF 12-NPD-01-3dm-170c XP100-HV 100kW XP200-HV 200kW XP250-HV 250kW XP200-HV-TL 12-Jan-2015) 13-Feb-2015) inverter transformer
2003 - Not Available

Abstract: No abstract text available
Text: -p for transformer coupled outputs and 7.5Vp-p at the bus. An external input, TX INHIBIT, takes priority , In RX Data In PHASE MODULATED BIPOLAR DATA ISOLATION TRANSFORMER Manchester II data , (Notes 1-6, 12) Threshold voltage, transformer Coupled, Measured on Stub (Note 7) Common-Mode Voltage , on bus Transformer Coupled Across 70 Ohm, measured on Stub (Note 9) Output Noise, differential (Direct coupled) Output Offset Voltage, transformer Coupled Across 70 Ohm Rise/Fall Time TX DATA IN/TX


Original
PDF BU-63155L3 MIL-STD-1553 MIL-STD-1553 32-Pad BU-63155 MIL-STD-1553A, 1553B, BU63155 1-800-DDC-5757 A5976
2009 - ts audio transformer

Abstract: TPA3123D2 SLOA133 step down transformer function audio output transformer C2RMS
Text: Application Report SLOA133 ­ March 2009 Audio Power Amplifier Operation with Transformer Load , transformer with inadequate low-frequency performance may sometimes shut down because of saturation of the transformer core. This paper explains the cause of this sort of shutdown and provides strategies for avoiding , transformer with inadequate low-frequency performance may shut down when its output is stepped from zero to , first half cycle of the sine output. The root cause is saturation of the transformer core. If shutdown


Original
PDF SLOA133 ts audio transformer TPA3123D2 SLOA133 step down transformer function audio output transformer C2RMS
pulse transformer catalog

Abstract: leakage transformer IF transformer
Text: , specify and select the right magnetic component - transformer , inductor, filter -fo r your application , 1 .0 DYNAMIC PARAMETERS 1 .5 PULSE DURATION When a pulse transformer is inserted into a circuit, the transformer degrades any pulse which passes through it. The dynamic parameters of a pulse transformer are defined by the ways in which a "perfect" pulse is degraded. For example, the rise time of a pulse transformer is defined as the rise time of an output pulse when a zero rise time pulse is


OCR Scan
PDF
1999 - autotransformer design

Abstract: 3 winding phase shifting transformer equivalent circuit autotransformer autotransformer multiple winding Transformer 4 way power divider pulse transformer circuit stepdown transformer TRANSFORMER for pc Signal Path Designer
Text: Document 157-1 Signal Transformer Application and Specification A transformer in its simplest , transformer that needs to provide an impedance match to a small signal communications network. In this , transmission of data at low power levels with DC isolation (the wide band transformer ) and those designed to be non-isolating (the auto transformer ). These types of transformers are not limited to low power , Band Transformer Leakage Flux Flux linking both coils Figure 1 through to the other winding


Original
PDF
Allen-Bradley starter 709

Abstract: Allen-Bradley 709 starter Allen-Bradley bulletin 712 Bulletin 709 Motor Starter Coil Allen-Bradley 800T Bulletin 509 contactor coils Allen-Bradley bulletin 509 starter Allen-Bradley 709 Allen-Bradley reduced voltage starter Allen-Bradley contactor 100
Text: TRANSFORMER SELECTION Purpose Introduction Description Considerations for Selecting the Transformer The , The control circuit transformer is a device designed to provide a reduced control voltage for , devices make up the majority of the loads supplied by the control circuit transformer . The proper size, or the volt-ampere (VA) rating, of the transformer is important, as it will be a determining factor in the life of the transformer , which ultimately will reflect on the proper operation of control devices


OCR Scan
PDF
2011 - 12v transformer winding formula

Abstract: HALO Electronics tgmr multiple winding Transformer 8 pin 24v transformer center tapped transformer 12v 3A RS 7915 400 v isolation transformer MAX13256 bridge rectifier 24V AC to 24v dc TGMR
Text: 19-5847; Rev 1; 8/11 EVALUATION KIT AVAILABLE MAX13256 36V H-Bridge Transformer Driver for Isolated Supplies General Description The MAX13256 H-bridge transformer driver provides a simple solution for making isolated power supplies up to 10W. The device drives a transformer 's primary coil with up to 300mA of current from a wide 8V to 36V DC supply. The transformer 's secondary-to-primary , 50% duty cycle to prevent DC current flow through the transformer , regardless of which clock source


Original
PDF MAX13256 MAX13256 300mA 12v transformer winding formula HALO Electronics tgmr multiple winding Transformer 8 pin 24v transformer center tapped transformer 12v 3A RS 7915 400 v isolation transformer bridge rectifier 24V AC to 24v dc TGMR
transformer calculation ret 521

Abstract: automatic phase changer file 0-12 1a transformer step down transformer winding ratio automatic phase changer tap transformer mva BO-02 3 phase automatic phase changer neutral and earth calculation ABB tripping curves
Text: Transformer protection terminal RET 521*2.1 1MRK 504 012-BEN Page 1 Issued May 1999 Changed , transformer protection terminal in a compact design - Overexcitation restraint with 5th harmonic · , sequence quantity elimination · Variants: · Two-winding transformer application · Three-winding transformer application · Both with multi-breaker arrangement connections possibilities · No interposing , type tested software · Transformer differential protection - for two- and three-winding transformers


Original
PDF 012-BEN SE960158) 010-BEN 001-BEN 015-BEN 057-BEN S-721 transformer calculation ret 521 automatic phase changer file 0-12 1a transformer step down transformer winding ratio automatic phase changer tap transformer mva BO-02 3 phase automatic phase changer neutral and earth calculation ABB tripping curves
2005 - Transformer Protection

Abstract: 400kVA C3746 400kva transformer 800va ups circuit bussmann Fuse 170M series 4503 transformer JCW-1E fuse 170m 800va ups
Text: transformer protection. In practice, other components must be considered in applying circuit overcurrent , larger than as shown below. Individual transformer primary fuses are not necessary where the primary , % maximum 300% maximum 2 amps to 9 amps Less than 2 amps TRANSFORMER Primary 600V or Less , dual-element fuses can be sized on the transformer primary and/or secondary rated at 125% of the transformer , protection may be satisfied with multiple overcurrent devices that protect feeders fed from the transformer


Original
PDF 5500V 7500V 4000V 6000V 8000V Transformer Protection 400kVA C3746 400kva transformer 800va ups circuit bussmann Fuse 170M series 4503 transformer JCW-1E fuse 170m 800va ups
1999 - b-3067

Abstract: BUS-25679 BU-65620 ddc b-3067 HLP-6002 datasheet center tapped transformer BU-61590 BTTC B-3067 B-3067 TRANSFORMER 12v center tap transformer
Text: the subsystem to the data bus." By definition, the terminal includes the isolation transformer as , , therefore, includes selection and interconnection of the isolation transformer . In order to ensure proper , series hybrids to a 1553 data bus. Connections for both direct (short stub) and transformer (long stub , ) are indicated in the figure. ACE component is called the isolation transformer . As stated above, this is defined to be part of the terminal. For the transformer (long stub) coupling configuration


Original
PDF AN/B-27 MIL-STD-1553B 1-800-DDC-5757 A5976 b-3067 BUS-25679 BU-65620 ddc b-3067 HLP-6002 datasheet center tapped transformer BU-61590 BTTC B-3067 B-3067 TRANSFORMER 12v center tap transformer
1994 - EF25 transformer

Abstract: etd39 core type smps full bridge transformer design Nyleze AN-16 topswitch EF20 TRANSFORMER TDK EF25 epoxylite 203 EE19 TDK Ferrite Core PC40 EPOXYLITE 814 EFD20 TDK Ferrite Core PC40
Text: ® TOPSwitch Flyback Transformer Construction Guide ® Application Note AN , TOPSwitch. Margin wound and triple insulated wire transformer designs are derived in Appendix B for a 12 V , data sheets, and application notes AN-14 and AN-16. More details on flyback transformer theory and , and electrical characteristics used in transformer design. Some manufacturers also provide additional , provide mechanical dimensions for transformer design. The bobbin manufacturers in Appendix A offer a


Original
PDF AN-18 AN-16. EF25 transformer etd39 core type smps full bridge transformer design Nyleze AN-16 topswitch EF20 TRANSFORMER TDK EF25 epoxylite 203 EE19 TDK Ferrite Core PC40 EPOXYLITE 814 EFD20 TDK Ferrite Core PC40
single phase transformer

Abstract: No abstract text available
Text: transformer and how does it work? A transformer is an electrical appara­ tus designed to convert , € voltages and works on the magnetic induction principle. A transformer has no moving parts and is a , transformer has a 480 volt primary and the available line voltage is running at 504 volts, the primary , secondary windings, or insulation between the two. A shielded transformer is designed with a metallic , KVA capacity is reduced correspondingly. For example, if a 480 volt primary transformer with a 240


OCR Scan
PDF
2013 - transformer 330 MVA

Abstract: merlin gerin switchgear schneider transformer 100mva transformer distribution transformers
Text: Enhance Safety Solutions for the Mining Industry Global Transformer Capabilities Schneider Electric has a large network of transformer manufacturing plants around the world, producing medium power , , measurement and power transformers. Overview Transformer Solutions We are proud to present to you Schneider Electric’s complete transformer product portfolio. These products showcase both the local and , Australian Standard Electrical Transformers (ASET), a Victorian distribution transformer and kiosk


Original
PDF 150195C; PGE210184; EC008813; C2356 SEAU26703 SAUENGPRODUCT13 transformer 330 MVA merlin gerin switchgear schneider transformer 100mva transformer distribution transformers
2003 - BTTC B-3300

Abstract: BTTC b-3226 B-3818 LPB-5015 MMT-3005 BU63155 3205 decoder TST-9007 MLP-2205
Text: recommended transformers, the transmitter typically produces 21.5Vp-p for transformer coupled outputs and , II data SHORT OR LONG STUB COUPLING ISOLATION TRANSFORMER 2 BU-63155L3 C-10/05-0 , Capacitance (Notes 1-6, 12) Threshold voltage, transformer Coupled, Measured on Stub (Note 7) Common-Mode , Transformer Coupled Across 70 Ohm, measured on Stub (Note 9) Output Noise, differential (Direct coupled) Output Offset Voltage, transformer Coupled Across 70 Ohm Rise/Fall Time TX DATA IN/TX DATA IN to TX DATA


Original
PDF BU-63155L3 MIL-STD-1553 32-Pad BU-63155 MIL-STD-1553A, 1553B, BU63155 Plas2482 BTTC B-3300 BTTC b-3226 B-3818 LPB-5015 MMT-3005 3205 decoder TST-9007 MLP-2205
2007 - Westinghouse Sudden Pressure Relay

Abstract: 115KV transformer westinghouse transformer inrush
Text: Transformer Protection Application Guide About the Author George Rockefeller is President of , editorial corrections Transformer Protection Application Guide This guide focuses primarily on , overall view of the economic impact of a transformer failure and what can be done to reduce the risk, including: · The direct economic impact of repairing or replacing the transformer . · The indirect , protection scheme against the consequences of relying on other protection or sacrificing the transformer


Original
PDF BE1-51 Westinghouse Sudden Pressure Relay 115KV transformer westinghouse transformer inrush
2003 - BU-63155L3

Abstract: TSM-2205 DSS-1005 B-3227 bu-63155 1553* driver BU63155L3 BU63155 Q9100
Text: used with the recommended transformers, the transmitter typically produces 21.5Vp-p for transformer , DECODER SHORT OR LONG STUB COUPLING ISOLATION TRANSFORMER 2 TRANSMITTER SECTION TX Data Out , ) Differential Input Capacitance (Notes 1-6, 12) Threshold voltage, transformer Coupled, Measured on Stub (Note 7 , on bus Transformer Coupled Across 70 Ohm, measured on Stub (Note 9) Output Noise, differential (Direct coupled) Output Offset Voltage, transformer Coupled Across 70 Ohm Rise/Fall Time TX DATA IN/TX


Original
PDF BU-63155L3 MIL-STD-1553 32-Pad BU-63155 MIL-STD-1553A, 1553B, AS9100C BU-63155L3 TSM-2205 DSS-1005 B-3227 1553* driver BU63155L3 BU63155 Q9100
2011 - diode st1

Abstract: Current transformer switching transformer 24v
Text: Transformer Driver for Isolated Supplies General Description The MAX13256 H-bridge transformer driver , guarantees a fixed 50% duty cycle to prevent DC current flow through the transformer , regardless of which , Transformer  Undervoltage Lockout  2.5V to 5V Compatible Logic Interface  Internal or External , www.maximintegrated.com. 19-5847; Rev 1; 8/11 MAX13256 36V H-Bridge Transformer Driver for Isolated Supplies , mV 2 MAX13256 36V H-Bridge Transformer Driver for Isolated Supplies ELECTRICAL


Original
PDF MAX13256 MAX13256 300mA diode st1 Current transformer switching transformer 24v
2014 - PGC 3100

Abstract: EL731
Text: CURRENT TRANSFORMERS Product CT200 (PGC-2056) Current Transformer CT200L (PGC-2089) Current Transformer EFCT-26 (PGC-3026) Ground-Fault Current Transformer EFCT-1 (PGC-3082) Ground-Fault Current Transformer EFCT-2 (PGC-3140) Ground-Fault Current Transformer EFCT-1FC (PGC-31FC) Flux , -5025) Ground-Fault Current Transformer SE-CS30-70 (PGC-5060) Ground-Fault Current Transformer SE-CS30-4 (PGC-5095) Ground-Fault Current Transformer SE-CS30-5 (PGC-5130) Ground-Fault Current Transformer SE-CS30-8 (PGC


Original
PDF SE-502 CT-200 SE-CS30 SE-704 EL731 PGR-3200 PGR-3100 SE-601 SE-105/SE-107 PGC 3100 EL731
2012 - SE 135

Abstract: TRANSFORMER CT 5A CURRENT TRANSFORMER PGC 3100 SE135 SE-CS10-8 SE-135 PGC-6080 EL731 se 130 n
Text: Diameter Accessory For CT200 (PGC-2056) Current Transformer Detects phase current or ground-fault , transformer used to detect ground-fault current. (5-A primary) Sensitive current transformer used to detect ground-fault current. (5-A primary) Sensitive current transformer used to detect ground-fault current. (5 , CT200L (PGC-2089) Current Transformer EFCT-26 (PGC-3026) Ground-Fault Current Transformer EFCT-1 (PGC-3082) Ground-Fault Current Transformer SE-330 MPS MPU-32 SE-701 FPU-32 FPS EL731 SE-701 MPU


Original
PDF SE-601 PGR-3100 PGR-3200 CT-200 SE-502 SE-701/SE-703 SE-704 EL731 SE-105/SE-107 SE-134C/SE-135 SE 135 TRANSFORMER CT 5A CURRENT TRANSFORMER PGC 3100 SE135 SE-CS10-8 SE-135 PGC-6080 se 130 n
2000 - BU-63152G3

Abstract: B-3227 PULSE B-3227 BU-63152G3-902 ddc B-3226 B-3300 TRANSFORMER bttc beta transformer LPB-5015 BTTC B-3300 B-3818 MIL-STD-1553 pulse transformer BETA
Text: MODULATED BIPOLAR DATA RX Data In SHORT OR LONG STUB COUPLING ISOLATION TRANSFORMER RX Data In RECEIVER , ! Direct Coupled Across 35 , Measured on Bus ! Transformer Coupled Across 70 , Measured on Stub (Note 9) Output Noise, Differential (Direct Coupled) Output Offset Voltage, Transformer Coupled Across , to 2 MHz, applied to pins of the isolation transformer on the stub side (either direct or transformer coupled), and referenced to transceiver ground. Transformer must be a DDC recommended transformer or other


Original
PDF BU-63152 MIL-STD-1553 30Vpp. MIL-STD-1553A, 1553B, BU-63152 1-800-DDC-5757 A5976 BU-63152G3 B-3227 PULSE B-3227 BU-63152G3-902 ddc B-3226 B-3300 TRANSFORMER bttc beta transformer LPB-5015 BTTC B-3300 B-3818 MIL-STD-1553 pulse transformer BETA
Supplyframe Tracking Pixel