The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
FLTR100V10Z GE Critical Power FLTR100V10 Filter Module, 75 Vdc Input Maximum, 10 A Maximum
FLTR100V20Z GE Critical Power FLTR100V20 Filter Module, 75 Vdc Input Maximum, 20 A Maximum
ISL2100AAR3Z-T Intersil Corporation 100V, 2A Peak, High Frequency Half-Bridge Drivers; DFN9; Temp Range: -40° to 85°C
ISL6719ARZ Intersil Corporation 100V Linear Bias Supply; DFN9; Temp Range: -40° to 105°C
ISL89401AR3Z Intersil Corporation 100V, 1.25A Peak, High Frequency Half-Bridge Drivers; DFN9, SOIC8; Temp Range: -40° to 125°C
ISL2100AAR3Z Intersil Corporation 100V, 2A Peak, High Frequency Half-Bridge Drivers; DFN9; Temp Range: -40° to 85°C

transformer 240v to 100v Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
FUSE M4 250v G

Abstract: FUSE M4 250v E 3EZM4 transformer 240v to 100v M1 250V FUSE FUSE M1 250v G MA104 MA304 3EXM4 MA101
Text: voltage M series module MA304: Four Voltage Selection Card Marked 100V /120V/230V/ 240V . One card comes , 240V 120V H K Note 2 B 120V 100V A A 120V B Note 1 Neutral C C , Note 4 G 120V 100V 230V 240V A Power On/Off A 20V Note 2 H K Note 2 H , 120V Customer Transformer Primaries XM1 & ZM1 Power On/Off Note 3 Neutral 20V 100V B , Phase G Customer Transformer Primaries XM4 & ZM4 120V 100V Power


Original
PDF
220 110 transformer

Abstract: voltage selector switch SWA Schurter 3A 220v transformer STEP UP transformer 110- 220V VDE 0630 220 to 110 power vde-0630 110v to 220v step up transformer 4006 transformer 4047 BE
Text: 230V 120V 115V 120V 220V 240V 220V 220V 120V 130V 240V 200V 120V 230V 120V 220V 100V , 208 100 125 +9% 100 200V 100V 120V blank 240V 100 2 125 110V 110V 120V 220 220 110 , -13% 240 240V 240V 240 blank 115V blank 100V 110 240V 240V NC 240V , allows wiring of up to six different transformer tappings to the switch. The use of a voltage selector , 240 127 3 120 115 220 blank 220 100 220 120 220 200V 100 100V 110 220 115 2 110


Original
PDF
smps 230V

Abstract: 115 V -250V power supplies transformer transformer 240v to 100v 240v smps 3EXM4S EN55022-B smps 14 pin connector
Text: Transformer Primaries 100V B Note 3 230V 240V 120V 120V 5EFM1SC (IEC Connector, DPST On , ·The optional voltage selector provides a convenient means to change transformer primary connection , 4 - 100V , 120V, 230V, 240V Selectable Mounting Style Fuseholder Type Flange Snap-in , must be met. Refer to page 97 for more information on available RFI filter types. * 1 - 120V/ 240V Fixed 4 - 100V , 120V, 230V, 240V Selectable 1 2 Fuse Changing European Fusing Arrangement


Original
PDF
3EXM4S

Abstract: En5502-B 5EHM1S smps 230V smps 14 pin connector
Text: voltage selector provides a convenient means to change transformer primary connection, and it is , Note 2 USE ONLY WITH 250V FUSES 230V 240V A A Note 4 H K 100V B C Note 4 , WITH 250V FUSES DISCONNECT POWER BEFORE REPLACING FUSES G 100V 120V 230V 240V Thread , DISCONNECT POWER BEFORE REPLACING FUSES 100V 120V 230V 240V C D A 3EXM4 & 3EZM4 (IEC , REPLACING FUSES E D B A 100V 120V 230V 240V C D B A E 6VM4SC (IEC Connector


Original
PDF En5502-B UL544, UL2601 EN60601 3EXM4S 5EHM1S smps 230V smps 14 pin connector
2000 - 110v 400Hz transformer

Abstract: 2026SS 230v to 115v 400hz transformer 240v transformer 400Hz 115v 115v 400Hz transformer 110-220 4002 transformer transformer 240v to 100v FASTON screw
Text: 240V /2 For separate winding tapped transformer Series/parallel 100, 120, 220, 240V /3 For separate , 120V C Contacts 100V 120V 220V 240V a,c,e b,c,e a,d b,d G L 0.047µF (X2) L1 , connections: Circuit 1 H1 (or H2) to transformer neutral G to B Circuit 2 H1 (or H2) to F G to B , tapped transformer 110, 220, /1 Style/Fuse Variants Snap-in with one fuse discontinued , Range: -250C to +850C Operating Voltage: 250Vac Operating Frequency: 0 to 400Hz Test Voltage: L+N to


Original
PDF 200pF 110v 400Hz transformer 2026SS 230v to 115v 400hz transformer 240v transformer 400Hz 115v 115v 400Hz transformer 110-220 4002 transformer transformer 240v to 100v FASTON screw
2000 - transformer 400Hz 115v

Abstract: 110v 400Hz transformer 230v to 115v 400hz SF2020 transformer 220V to 120V transformer 240v to 100v
Text: 110, 220, 240V /2 For separate winding tapped transformer Series/parallel 100, 120, 220, 240V /3 For , 120V 220V 240V G L1 2x2,200pF (Y) b B a 120V A 100V Series/Parallel Connection of Separate , . For use without external switch, make the following connections: Circuit 1 H1 (or H2) to transformer , Temperature Range: -250C to +850C Operating Voltage: 250Vac Operating Frequency: 0 to 400Hz Test Voltage: L+N to ground, 2700Vdc, 2 seconds s Approved Submitted for Approval PART NUMBER DESIGNATION


Original
PDF 200pF transformer 400Hz 115v 110v 400Hz transformer 230v to 115v 400hz SF2020 transformer 220V to 120V transformer 240v to 100v
transformer 240v to 100v

Abstract: A6J4 6J4 CORCOM GA400 220v 20v 4a 220v to 120 vdc 100VJD 3A 220v transformer
Text: 240V 120V 100V A Hot B E F Transformer primary JA403: Mounting clips for .105 - , Off R S 220V 240V 120V 100V Note 2 Hot B 20V 100V J D E L F , Specify part number 6HJ4-4 & 6J4-2 2.330 Note 3 220V 240V 120V 100V A B J H Note 1 , without filter (VJ models) Maximum leakage current each Line to Ground: 6HJ4 or 6J4 Models non­filtered @250 VAC 50 Hz: 500 A 5 A Hipot rating (one minute): Line to Ground: Line to Line


Original
PDF
6J4 CORCOM

Abstract: corcom 6vj1 220v 20v 4a corcom 6J4 filter 220V 60 Hz JA411 JA-500 105125 rfi power line filter transformer 1A 220V
Text: Case Styles Unfiltered Models Filtered 6J4 & 6J4-2 Note 3 220V 240V 120V 100V A Hot Off , 220V 240V 120V 100V A B Power On/Off Hot Off Ground On B C Pilot light , capacitors. Designed to allow equipment to meet UL544 medical specifications for patient care and , health care requirements. Refer to page 97 for more information on available RFI Filter types. 104 , . Specifications subject to change. USA Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400


Original
PDF UL544 susceptib418 JA419 JA500, 6J4 CORCOM corcom 6vj1 220v 20v 4a corcom 6J4 filter 220V 60 Hz JA411 JA-500 105125 rfi power line filter transformer 1A 220V
transformer 240v

Abstract: transformer 1A 220V 220v 20v transformer LA303 LA400 LA201 LG EAB LA200 filter 220V 60 Hz EDL1S
Text: . Marked with 110V, 220V and 240V G 4 Voltage Select, No-Switch (DL4) Customer 120V 100V Note 1 Hot G Note 2 On/Off A 220V Transformer 240V Primaries A A 20V B B B , . Marked with 100V , 110V, 220V and 240V . One LA304 comes standard with each L4 model. C 100V D , back of module to prevent inadvertent access 1 (1a) (2) 4 Ground Transformer Primaries , 220V Transformer 240V Primaries A 20V B B C C C D D E E E F


Original
PDF
12v dc 240v ac inverter circuit diagram

Abstract: PBA150F-24 AC50 DC110 DC70 PBA150F-5 PBA10F-12 PBA10F-24 PBA10F-5 NAC-06-472
Text: 100V / 240V 60Hz, Io=100%, According to IEC60950-1,DENAN) 5 12 24 2 0.9 0.5 20max 48max 96max , (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1,DENAN) 3.3 5 9 12 15 24 48 3 3 1.7 1.3 , (Io=100%) (At cold start) 0.30/0.65max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1,DENAN , start) 0.4/0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1,DENAN) 3.3 5 9 12 15 24 , =100%) (At cold start) 0.4/0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1,DENAN) 3.3 5 9


Original
PDF PBA10F NAC-06-472 UL508 PBA10F-5 PBA10F-12 PBA150F BXH-001T-P0 SXH-001T-P0 12v dc 240v ac inverter circuit diagram PBA150F-24 AC50 DC110 DC70 PBA150F-5 PBA10F-12 PBA10F-24 PBA10F-5 NAC-06-472
2014 - Not Available

Abstract: No abstract text available
Text: at 60Hz during brownouts as low 100V and overvoltages as transformer high as 300V. Expandable , at 60Hz in double conversion mode Corrects brownouts to 156V at full load ( 100V at 50% load or less , Voltage(s) Supported 208V AC; 240V AC Nominal input voltage description Factory configured to , ) / 100V (50% load or less, derates linearly) High voltage transfer to battery power (setpoint) 280V , output, Transformer Included Highlights 6kVA / 6000VA / 5400W on-line double-conversion UPS; 0.9


Original
PDF 208/120V 240/120V 6000VA 240/120V SU6000RT4UTFHW RS232 5-15R, 5-15/20R SU6000RT4UTFHW
Not Available

Abstract: No abstract text available
Text: . INTERNATIONAL SERIES MODELS & RATINGS SECONDARY RATINGS rms1 SERIES PARALLEL VA (max) 10.0V CT, 0.050A 10.0VCT, 0.050A 10.0V CT. 0.110A 10.0V CT.0.350A 10 0V CT.0.950A 10.0V CT. 1.250A 12.6V CT , CT.0.070A 16.0V CT, 0.220A 16.0V CT, 0.600A 16.0V CT. 0.780A 24.0V CT, 0.021A 24.0V CT, 0.021 A 24.0V CT, 0.046A 24.0V CT.0.150A 24.0V CT.0.400A 24.0V CT.0.520A 36.0V CT. 0.031 A 36.0V CT,0.100A , 6.60 7.50 9.20 5.80 6.60 7.50 9.20 7.50 9.20 Note 1: Individual transformer coil rating is


OCR Scan
PDF E98949. 115/230V, 115/230V
2013 - Not Available

Abstract: No abstract text available
Text: interruption to connected equipment. 4U UPS power module and included 2U low-voltage transformer install in , at 60Hz in double conversion mode Corrects brownouts to 156V at full load ( 100V at 50% load or less , voltage transfer to battery power (setpoint) 156V (full load) / 100V (50% load or less, derates , /120V or 240/120V Hardwire output, Transformer Included Highlights 6kVA / 6000VA / 5400W on-line , full-time sine wave output within 2% of selectable 208/ 240V and 120V nominal at 60Hz during brownouts as


Original
PDF SU6000RT4UTFHW 208/120V 240/120V 6000VA RS232 5-15R, 5-15/20R AS400
2013 - Not Available

Abstract: No abstract text available
Text: power modules Two BP240V10RT3U battery packs One SU6000XFMR2U 208/ 240V to 120V transformer SUPDMB20K , (set rear panel dipswitch on transformer module to appropriate 208 or 240V input setting) Frequency , receptacle details Total 120V output is limited to 4992 watts for 208V input and 5760 watts for 240V , Low voltage transfer to battery power (setpoint) 100V High voltage transfer to battery power , battery modules, N+1 fault tolerance at loads up to 10kVA USB, RS232 & EPO ports; support for SNMP/WEB


Original
PDF SU20KRT-1TF 20kVA 208/120V 240/120V 000VA 10kVA RS232
2014 - Not Available

Abstract: No abstract text available
Text: (set rear panel dipswitch on transformer module to appropriate 208 or 240V input setting) Frequency , receptacle details Total 120V output is limited to 4992 watts for 208V input and 5760 watts for 240V input , dimensions for UPS/Power module and Included battery pack each refer to a single unit Stepdown transformer , response in optional economy mode Low voltage transfer to battery power (setpoint) 100V High , power and battery modules, N+1 fault tolerance at loads up to 10kVA USB, RS232 & EPO ports; support


Original
PDF 20kVA 208/120V 240/120V 000VA 240/120V SU20KRT-1TF 10kVA RS232
IEC -320 C14 SWITCH

Abstract: transformer 240v 4EDL1S IEC 60320-1
Text: module to prevent inadvertent access Device Transformer Primaries 4 Voltage Select, No-Switch (HL4) Customer 120V 100V 220V Transformer 240V Primaries Replacement Fuse Holders LA200: North American , models. Marked with 110V, 220V and 240V 4 Voltage Select, No-Switch (DL4) Customer 120V 100V 220V Transformer 240V Primaries LA304: Voltage Select Wheel, 4 position Selection drum for use with L4 models. Marked with 100V , 110V, 220V and 240V . One LA304 comes standard with each L4 model. Hot Note 1 G


Original
PDF
2013 - Not Available

Abstract: No abstract text available
Text: power modules Two BP240V10RT3U battery packs One SU6000XFMR2U 208/ 240V to 120V transformer SUPDMB20K , dipswitch on transformer module to appropriate 208 or 240V input setting). Frequency compatibility , details Total 120V output is limited to 4992 watts for 208V input and 5760 watts for 240V input , refer to a single unit Stepdown transformer dimensions (height x width x depth / inches) 3.5 x , economy mode Low voltage transfer to battery power (setpoint) 100V High voltage transfer to


Original
PDF SU16KRT-1TF 16kVA 208/120V 240/120V 000VA RS232 L6-30R,
2014 - Not Available

Abstract: No abstract text available
Text: SU8000RT3UPM UPS power modules Two BP240V10RT3U battery packs One SU6000XFMR2U 208/ 240V to 120V , step-down transformer supports 120V output (set rear panel dipswitch on transformer module to appropriate , Included battery pack each refer to a single unit Stepdown transformer dimensions (height x width x , Low voltage transfer to battery power (setpoint) 100V High voltage transfer to battery power , Hot-swap power and battery modules, N+1 fault tolerance at loads up to 8kVA USB, RS232 & EPO ports


Original
PDF 16kVA 208/120V 240/120V 000VA 240/120V SU16KRT-1TF RS232 L6-30R,
f103600

Abstract: f28-200 F48-023 F24-045 FS10-110 F20-120 F20-055 F16-070 F12-090 TRANSFORMER CT 2A
Text: 6.3V @ 0.4A 8.0V @ 0.3A 10.0V @ 0.24A 12.0V @ 0.2A 14.0V @ 0.17A 18.0V @ 0.13A 24.0V @ 0.1A , 10.0V @ 1.2A 12.0V @ 1.0A 14.0V @ 0.84A 18.0V @ 0.7A 24.0V @ 0.5A 28.0V @ 0.44A 60.0V @ 0.2A 5.0V @ 4.0A 6.3V @ 3.2A 8.0V @ 2.5A 10.0V @ 2.0A 12.0V @ 1.6A 14.0V @ 1.4A 18.0V @ 1.1A 24.0V @ , transformer from Triad is an extremely versatile tool for PC board applications. Split Pack transformers are , SECONDARY PRI 6 PIN PRI 8 PIN VA SERIES F10-110 FS10-110 10.0V CT @ 0.11A F12-090 FS12-090 12.6V CT


Original
PDF 115v/230v 50/60Hz. F10-110 FS10-110 F12-090 FS12-090 F16-070 FS16-0 E53148 f103600 f28-200 F48-023 F24-045 FS10-110 F20-120 F20-055 F16-070 F12-090 TRANSFORMER CT 2A
F24-045

Abstract: No abstract text available
Text: -85 FS36-65 FS48-050 FS56-045 FS120-02 2.5 10.0V CT 12.6V CT 16.0V CT 20.0V CT 24.0V CT 28.0V , 56.0V CT © 0.22A 120.0V CT @ 0.1 A 5.0V 6.3V 8.0V 10.0V 12.0V 14.0V 18.0V 24.0V 28.0V , -800 F28-700 F36-550 F48-400 F56-350 F120-160 D 10.0V CT 12.6V CT 16.0V CT 20.0V CT 24.0V CT , -700 FS36-550 FS48-400 FS56-350 FS120-160 20.0 10.0V CT 12.6V CT 16.0V CT 20.0V CT 24.0V CT , -650 F120-300 Steflon P A C K ™ 5.0V 6.3V 8.0V 10.0V 12.0V 14.0V 18.0V 24.0V 28.0V 60.0V


OCR Scan
PDF
FS10 TM

Abstract: F28-700 Transistor FS10 f28-200 F10-110 f10360 TRANSFORMER CT 2A TRANSFORMER CT 1A FS16-400 F12-500
Text: 1.1 10.0V CT @ 0.11A 12.6V CT @ 0.09A 16.0V CT @ 0.07A 20.0V CT @ 0.055A 24.0V CT @ 0.045A , 0.22A 6.3V @ 0.18A 8.0V @ 0.14A 10.0V @ 0.11A 12.0V @ 0.09A 14.0V @ 0.08A 18.0V @ 0.06A 24.0V @ , 0.17A 18.0V @ 0.13A 24.0V @ 0.1A 28.0V @ 0.09A 60.0V @ 0.04A 6.0 10.0V CT @ 0.6A 12.6V CT @ , @ 0.5A 14.0V @ 0.4A 18.0V @ 0.34A 24.0V @ 0.25A 28.0V @ 0.22A 60.0V @ 0.1A 12.0 10.0V CT , 1.6A 10.0V @ 1.2A 12.0V @ 1.0A 14.0V @ 0.84A 18.0V @ 0.7A 24.0V @ 0.5A 28.0V @ 0.44A 60.0V @


Original
PDF E53148 Primar/16 FS10 TM F28-700 Transistor FS10 f28-200 F10-110 f10360 TRANSFORMER CT 2A TRANSFORMER CT 1A FS16-400 F12-500
triad f7-24

Abstract: F8-120 100 VA 230v 50 Hz CENTER TAP transformer 230v 50 Hz CENTER TAP transformer FD4-12 F756 FD5-10 FD4-24 FD6-16 FD7-120
Text: 100.0 Output Rating Range: 10.0V CT TO 120.0V CT Class B UL Recognized UL File E53148 QUICK , RATING 10.0V CT @ 0.25A 12.6V CT @ 0.2A 16.0V CT @ 0.15A 20.0V CT @ 0.12A 24.0V CT @ 0.1A 28.0V CT , @ 0.22A 120.0V CT @ 0.1A 10.0V CT @ 3.0A 12.6V CT @ 2.5A 16.0V CT @ 2.0A 20.0V CT @ 1.5A 24.0V , 10.0V CT @ 5.0A 12.6V CT @ 4.0A 16.0V CT @ 3.5A 20.0V CT @ 2.8A 24.0V CT @ 2.4A 28.0V CT @ 2.0A , transformer series from Triad offers a significant reduction in size & weight for a given VA rating. Split


Original
PDF 50/60Hz E53148 F3-10 F3-12 F3-16 F3-20 F3-24 F3-28 F3-36 F3-48 triad f7-24 F8-120 100 VA 230v 50 Hz CENTER TAP transformer 230v 50 Hz CENTER TAP transformer FD4-12 F756 FD5-10 FD4-24 FD6-16 FD7-120
1998 - Photo DIAC

Abstract: pulse transformer ic 800w inverter diac catalog diac 240V VRRM VRSM VBR thyristor TRIGGER PULSE TRANSFORMER photo thyristor triac 400v 80a diac 10A
Text: . 100V Line Figure 10.1 Measures for dv/dt When large voltage dv/dt is applied to thyristors, CR , Section of Withstanding Voltage Items 100V to 120V Line System Supply Location Voltage of Use , 100, 0.5W 100, 1W 10.3 Gate Circuit and Gate Trigger Current 200V to 240V Line System , flows (heater, solenoid load) Load current x 1.3 to 1.5 permissible current for thyristor Example: 1A x 1.5 Applicable to 2A type thyristors. Determine the size of heatsink fin from the catalog


Original
PDF
FS24-250

Abstract: F24-500 F56-045 FS24-045 F20-600 fs1020 f28-200 F24-045 F20-055 F10-110
Text: Triad Magnetics Product Details Triad Transformer Catalog PC MOUNT - SPLIT PACK Description: The Triad Split Pack split bobbin transformer from Triad Magnetics is an extremely versatile tool for , PAGE CLOSE PAGE Primary: 115/230 V, 50/60 Hz VA Ranges: 1.1 to 36.0 Secondary: Series - 10 to 120V Parallel - 5 to 60V Class B UL Recognized UL File E53148 PC MOUNT - SPLIT PACK Secondary , -110 6 Pin* 1.1 10.0V CT @ 0.11A 5.0V @ 0.22A 15/16 1 1/8 1 3/8 - 0.250 0.250


Original
PDF
SEC IRF 640

Abstract: ct0045 TAMURA lr 69808 CT030-0
Text: Insulation Sys. • CSA Cert: CSA 22.2 Nos. 0, 66 File No. LR 69808. • 2500VAC Hipot. Pri to Sec. a , 5.70 6.40 10.0V CT, 0.110A 10.0V CT.0.250A 10.0V CT,0.600A 10.0V CT.1.200A 12.6V CT, 0.090A , , 0.400A 16.0V CT. 0.800A 20.0V CT.0.055A 20.0V CT, 0.120A 20.0V CT.0.300A 20.0V CT. 0.600A 24.0V CT, 0.045A 24.0V CT, 0.100A 24.0V CT, 0.250A 24,0V CT.0.5QOA 28.0V CT.0.040A 28,0V C T.0 085A 28.0V CT , , 2.000A 8.QV.O.140A 8.0V, 0.300A 8.0V. 0.800A 8.0V, 1.600A 10.0V.0.110A 10.0V . 0.240A 10,0V, 0.500A


OCR Scan
PDF E95844. E91239. 2500VAC 115/230V 3FS-210 3FS-310 3FS-410 3FS-510 3FS-212 3FS-312 SEC IRF 640 ct0045 TAMURA lr 69808 CT030-0
Supplyframe Tracking Pixel