The Datasheet Archive

Top Results (4)

Part Manufacturer Description Datasheet Download Buy Part
LM56BIMMX Texas Instruments Dual Output Low Power Thermostat 8-VSSOP -40 to 125
LM56CIMM Texas Instruments Dual Output Low Power Thermostat 8-VSSOP -40 to 125
LM26CIM5X-VPA Texas Instruments SOT-23, ?3?C Accurate, Factory Preset Thermostat 5-SOT-23 -55 to 125
LM26CIM5-HHD Texas Instruments SOT-23, ?3?C Accurate, Factory Preset Thermostat 5-SOT-23 -55 to 125

thermostat rc1 Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
2004 - CSNC241-500

Abstract: 2455r CSLH3A45 TD5A CSNC241 AWM700 CSNE151-100 3455rm 2455rbv 2455RM
Text: 18 20 20 22 35 20 25 30 REFERENCE 143-101FAG- RC1 143-201FAG- RC1 143-501FAG- RC1 143-102LAG- RC1 143-302LAG- RC1 143-502LAG- RC1 143-103QAG- RC1 143-303QAG- RC1 143-503QAG- RC1 10 % , 20 25 20 22 35 20 28 32 2,29 [0.09] 9,5 [0.375] REFERENCE 145-101FAG- RC1 145-201FAG- RC1 145-301FAG- RC1 145-501FAG- RC1 145-102LAG- RC1 145-302LAG- RC1 145-502LAG- RC1 145-103QAG- RC1 145-303QAG- RC1 145-503QAG- RC1 1,14 DIA. [0.045] 0,1016 DIA. [0.004] 20 % Tolerance at 25 °C [77 °F


Original
PDF 100455-EN CSNC241-500 2455r CSLH3A45 TD5A CSNC241 AWM700 CSNE151-100 3455rm 2455rbv 2455RM
2007 - Not Available

Abstract: No abstract text available
Text: — Note: Thermostat mode = Comparator Mode Conversion resolution = 9-bit (i.e., RC0 = 0 and RC1 = 0 , defaults permit stand-alone operation as thermostat ■Shutdown mode to minimize power consumption ■Separate open drain output pin operates as an interrupt or comparator/ thermostat output , thermostat output that indicates if the temperature has exceeded userprogrammable limits (Over/Under , number of TOS and THYS bits used during the thermostat comparison is equal to the conversion resolution


Original
PDF STTS75 150ms
2009 - C900

Abstract: STLM75 STTS75 STTS751 0034D
Text: Note: Thermostat mode = comparator mode Conversion resolution = 9-bit (i.e., RC0 = 0 and RC1 , thermostat Shutdown mode to minimize power consumption Separate open drain output pin operates as an interrupt or comparator/ thermostat output (dual purpose event pin) Packages: ­ SO8 ­ , thermostat output that indicates if the temperature has exceeded userprogrammable limits (over/under , number of TOS and THYS bits used during the thermostat comparison is equal to the conversion resolution


Original
PDF STTS75 C900 STLM75 STTS75 STTS751 0034D
2009 - DS75

Abstract: STDS75 STLM75
Text: software-compatible with DS75 (dropin replacement) Power-up defaults permit standalone operation as thermostat , interrupt or comparator/ thermostat output (dual purpose event pin) Packages: ­ SO8 ­ MSOP8 (TSSOP8 , thermostat output that indicates if the temperature has exceeded userprogrammable limits (over/under , comparison and the operating mode. The number of TOS and THYS bits used during the thermostat comparison is , example, if the resolution is 9 bits, only the 9MSbs of TOS and THYS will be used by the thermostat


Original
PDF STDS75 DS75 STDS75 STLM75
2010 - Not Available

Abstract: No abstract text available
Text: Power-up defaults permit standalone operation as thermostat I Shutdown mode to minimize power consumption I Separate open drain output pin operates as an interrupt or comparator/ thermostat output , thermostat output that indicates if the temperature has exceeded userprogrammable limits (over/under , operating mode. The number of TOS and THYS bits used during the thermostat comparison is equal to the , resolution is 9 bits, only the 9 MSBs of TOS and THYS will be used by the thermostat comparator. The alarm


Original
PDF STTS75
2007 - transistor c900

Abstract: DS75 STDS75 STLM75
Text: DS75 (dropin replacement) Power up defaults permit stand-alone operation as thermostat , operates as an interrupt or comparator/ thermostat output (dual purpose event pin) SO8 (M , resistor. Note: The open drain thermostat output that indicates if the temperature has exceeded , during the thermostat comparison is equal to the conversion resolution set by the FT1 and FT0 Bits in , will be used by the thermostat comparator. The alarm fault tolerance is controlled by the FTI and FTO


Original
PDF STDS75 150ms transistor c900 DS75 STDS75 STLM75
2007 - STDS75

Abstract: STLM75 STTS75 thermostat rc1
Text: measurement Power up defaults permit stand-alone operation as thermostat Shutdown mode to , / thermostat output (dual purpose event pin) SO8 (M) Packages: ­ SO8 ­ MSOP8 (TSSOP8)(a) MSOP8 , resistor. Note: The open drain thermostat output that indicates if the temperature has exceeded , operating mode. The number of TOS and THYS bits used during the thermostat comparison is equal to the , resolution is 9 bits, only the 9MSbs of TOS and THYS will be used by the thermostat comparator. The alarm


Original
PDF STTS75 STDS75 STLM75 STTS75 thermostat rc1
2007 - Not Available

Abstract: No abstract text available
Text: stand-alone operation as thermostat Shutdown mode to minimize power consumption Separate open drain output pin operates as an interrupt or comparator/ thermostat output (dual purpose event pin) Packages: ­ SO8 ­ MSOP8 , , so it needs a pull-up resistor. Note: The open drain thermostat output that indicates if the , comparison and the operating mode. The number of TOS and THYS bits used during the thermostat comparison is , example, if the resolution is 9 bits, only the 9MSbs of TOS and THYS will be used by the thermostat


Original
PDF STTS75 150ms
2008 - DS75

Abstract: STDS75 STLM75 thermometer serial ds75
Text: with DS75 (dropin replacement) Power-up defaults permit standalone operation as thermostat , operates as an interrupt or comparator/ thermostat output (dual purpose event pin) SO8 (M , thermostat output that indicates if the temperature has exceeded userprogrammable limits (over/under , comparison and the operating mode. The number of TOS and THYS bits used during the thermostat comparison is , example, if the resolution is 9 bits, only the 9MSbs of TOS and THYS will be used by the thermostat


Original
PDF STDS75 DS75 STDS75 STLM75 thermometer serial ds75
2007 - Not Available

Abstract: No abstract text available
Text: – Power up defaults permit stand-alone operation as thermostat ■Shutdown mode to minimize power , comparator/ thermostat output (dual purpose event pin) ■SO8 (M) Packages: – SO8 – MSOP8 , thermostat output that indicates if the temperature has exceeded userprogrammable limits (Over/Under , of the comparison and the operating mode. The number of TOS and THYS bits used during the thermostat , thermostat comparator. The alarm fault tolerance is controlled by the FTI and FTO Bits in the Configuration


Original
PDF STDS75 150ms
2012 - Not Available

Abstract: No abstract text available
Text: thermostat mode(1) FT1 = fault tolerance1 bit RC0 = resolution conversion0 bit RC1 = resolution , with DS75 (dropin replacement) Power-up defaults permit standalone operation as thermostat Shutdown , comparator/ thermostat output (dual purpose event pin) MSOP8 (TSSOP8) package MSOP8 (TSSOP8 , resistor. Note: The open drain thermostat output that indicates if the temperature has exceeded , during the thermostat comparison is equal to the conversion resolution set by the FT1 and FT0 bits in the


Original
PDF STDS75
2008 - STDS75

Abstract: STLM75 STTS75
Text: temperature measurement Power-up defaults permit standalone operation as thermostat Shutdown , comparator/ thermostat output (dual purpose event pin) SO8 (M) Packages: ­ SO8 ­ MSOP8 (TSSOP8 , thermostat output that indicates if the temperature has exceeded userprogrammable limits (over/under , number of TOS and THYS bits used during the thermostat comparison is equal to the conversion resolution , , only the 9MSbs of TOS and THYS will be used by the thermostat comparator. The alarm fault tolerance is


Original
PDF STTS75 STDS75 STLM75 STTS75
2010 - THERMOSTAT SCHEMATIC

Abstract: DS75 thermometer serial ds75 STDS75 STLM75
Text: defaults permit standalone operation as thermostat Shutdown mode to minimize power consumption Separate open drain output pin operates as an interrupt or comparator/ thermostat output (dual purpose , pull-up resistor. Note: The open drain thermostat output that indicates if the temperature has , operating mode. The number of TOS and THYS bits used during the thermostat comparison is equal to the , resolution is 9 bits, only the 9 MSBs of TOS and THYS will be used by the thermostat comparator. The alarm


Original
PDF STDS75 THERMOSTAT SCHEMATIC DS75 thermometer serial ds75 STDS75 STLM75
2007 - TA1259

Abstract: No abstract text available
Text: thermostat Shutdown mode to minimize power consumption Separate open drain output pin operates as an interrupt or comparator/ thermostat output (dual purpose event pin) Packages: ­ SO8 ­ MSOP8 (TSSOP8)(a , : The open drain thermostat output that indicates if the temperature has exceeded userprogrammable , number of TOS and THYS bits used during the thermostat comparison is equal to the conversion resolution , , only the 9MSbs of TOS and THYS will be used by the thermostat comparator. The alarm fault tolerance is


Original
PDF STTS75 STTS75M2F STTS75 TA1259
2007 - STDS75

Abstract: No abstract text available
Text: operation as thermostat Shutdown mode to minimize power consumption Separate open drain output pin operates as an interrupt or comparator/ thermostat output (dual purpose event pin) Packages: ­ SO8 ­ MSOP8 , it needs a pull-up resistor. Note: The open drain thermostat output that indicates if the , thermostat comparison is equal to the conversion resolution set by the FT1 and FT0 Bits in the Configuration , thermostat comparator. The alarm fault tolerance is controlled by the FTI and FTO Bits in the Configuration


Original
PDF STDS75 150ms STDS75M2F STDS75
2012 - Not Available

Abstract: No abstract text available
Text: operation as thermostat I Shutdown mode to minimize power consumption I Separate open drain output pin operates as an interrupt or comparator/ thermostat output (dual purpose event pin) I , needs a pull-up resistor. Note: The open drain thermostat output that indicates if the , operating mode. The number of TOS and THYS bits used during the thermostat comparison is equal to the , resolution is 9 bits, only the 9 MSBs of TOS and THYS will be used by the thermostat comparator. The alarm


Original
PDF STDS75
2010 - THERMOSTAT SCHEMATIC

Abstract: C900 STLM75 STTS75
Text: standalone operation as thermostat Shutdown mode to minimize power consumption Separate open drain output pin operates as an interrupt or comparator/ thermostat output (dual purpose event pin , , so it needs a pull-up resistor. Note: The open drain thermostat output that indicates if the , number of TOS and THYS bits used during the thermostat comparison is equal to the conversion resolution , , only the 9 MSBs of TOS and THYS will be used by the thermostat comparator. The alarm fault tolerance


Original
PDF STTS75 THERMOSTAT SCHEMATIC C900 STLM75 STTS75
ZBD42203

Abstract: 5K80A SCH40 blow down valve NSH4 JIS10K SUS304 15ASGP Wiring Diagram thermostat NC 40 NC 90 JIS5K-80AFF
Text: , SUS316, SUS304 Calibration gas inlet: SUS316 Reference air inlet (option): Rc1 /8 or NPT1/8 Detector , (ejector): Alarm output when below 100 °C Mechanical thermostat N.O. (1a) contact, 200V AC, 2A Oxygen , thermocouple) 750mm Reference air inlet Non Rc1 /8 NPT1/8 Y A B Power supply 100V/115V AC 50 , guide tube system Rc1 /4 (upper side blow port should be selected) Reduction valve (unnecessary , inlet (to order) NPT1/8 or Rc1 /8 Calibration gas inlet (to order) SUS316 for 6/ 4 PTEF tube or 1/4


Original
PDF 10K65ARF) ZBD42203 5K80A SCH40 blow down valve NSH4 JIS10K SUS304 15ASGP Wiring Diagram thermostat NC 40 NC 90 JIS5K-80AFF
PWM IC 8-PIN DIP

Abstract: ST7Ultralite Micro USB 8-pin 27mhz IC USB ic timer 8pin port expander 32-bit i2c 8K DFN8 ST10 C166 motor thermostat control
Text: ST723xx ST7WIND ST726XX ST7MC 1K-8K FLASH 8 to 20 pins ADC8 - ADC10 RC1 % - E² SPI - SCI ­ , Heating, Air Conditioning, Thermostat Reason 3: No external clock source required Multiple internal


Original
PDF 32-bit 16-bit PWM IC 8-PIN DIP ST7Ultralite Micro USB 8-pin 27mhz IC USB ic timer 8pin port expander 32-bit i2c 8K DFN8 ST10 C166 motor thermostat control
1996 - PIC16FR72

Abstract: PIC16FR73 PIC16FR7X FUZZY pic MICROCONTROLLER pwm PIC16FR71 Ka 2355 16 pin dip
Text: analog interface, e.g. thermostat control, pressure sensing, etc. The PIC16FR72 device has 128 bytes , for applications requiring low-cost analog interface, e.g. thermostat control, pressure sensing, etc , analog interface, e.g. thermostat control, pressure sensing, etc. © 1996 Microchip Technology Inc , is ideally suited for applications requiring low-cost analog interface (e.g., thermostat control , VSS RC0/T1OSO/T1CKI 11 18 RC7 RC0/T1OSO/T1CKI 11 18 RC7 RC1 /T1OSI 12


Original
PDF PIC16FR7X PIC16FR71 PIC16FR710 PIC16FR711 PIC16FR72 PIC16FR73/73A PIC16FR74/74A PIC16FR7X DS30253B-page PIC16FR72 PIC16FR73 FUZZY pic MICROCONTROLLER pwm PIC16FR71 Ka 2355 16 pin dip
PIC ir transmit rc5 remote

Abstract: SOIC-18 FOOTPRINT philips RC6 IR
Text: -bit resolution is ideally suited for applications requiring low-cost analog interface, e.g. thermostat control , . thermostat control, pressure sensing, etc. The PIC16FR73/73A devices have 192 bytes of RAM and 22 I/O pins , applications requiring low-cost analog interface, e.g. thermostat control, pressure sensing, etc. The PIC16FR74 , analog interface (e.g., thermostat control, pressure sensing, etc). The PIC16FR7X family has special , Program Bus * £ 3 RBO/INT RB7:RB1 RCO/T10SO/T1CKI RC1 /T10SI RC2/CCP1 RC3/SCK/SCL RC4/SDI/SDA RC5/SD0


OCR Scan
PDF PIC16FR71 PIC16FR710 PIC16FR711 PIC16FR72 PIC16FR73/73A PIC16FR74/74A PIC16FR7X DS30253B-page PIC ir transmit rc5 remote SOIC-18 FOOTPRINT philips RC6 IR
8051 microcontroller interface with ir sensors

Abstract: projects based on fuzzy logic 8051 microcontroller for air conditioner thermostat rc1 8051 microcontroller Assembly language program fo C68HC05
Text: , consider a simple thermostat control system for a living room. To control the temperature, we start with , this fuzzy-logic thermostat prototype board. Clock speeds are low and the analog signals (0-5 V) are , thermostat project. may have many linguistic members: HOT, COLD, and NORMAL. Somewhat m ore interesting , complement of day and the sum of day and HARDWARE The fuzzy logic thermostat prototype (see Figure 3) was , heating systems. The 24-VAC supply lines to the thermostat power the fuzzy-logic thermostat controller


OCR Scan
PDF 16-bit PIC16C74, 8051 microcontroller interface with ir sensors projects based on fuzzy logic 8051 microcontroller for air conditioner thermostat rc1 8051 microcontroller Assembly language program fo C68HC05
2008 - temperature controlled fan project report

Abstract: thermostat failure rate thermostat MAX6625 PUG0014 PUG0015 UM0144 abstract on RTOS and multitasking
Text: Application Note Thermostat Demo Using eZ80Acclaim!® MCU AN020603-1008 Abstract Zilog Product Overview The Thermostat Demo describes how easy it is to develop Internet-enabled process , is implemented using different languages. The Thermostat drivers described in this application note , using Java applets. The Thermostat Demo is thus a Java-enabled process control application supported , v4.10.0). Copyright ©2008 by Zilog®, Inc. All rights reserved. www.zilog.com Thermostat Demo


Original
PDF eZ80Acclaim! AN020603-1008 temperature controlled fan project report thermostat failure rate thermostat MAX6625 PUG0014 PUG0015 UM0144 abstract on RTOS and multitasking
2004 - temperature controlled fan project

Abstract: temperature controlled fan project report sensor thermostat tm MAX6625 PUG0014 PUG0015 RM0008 UM0144 abstract on RTOS and multitasking
Text: Application Note Thermostat Demo Using the eZ80Acclaim!TM MCU AN016804-0504 ZiLOG Worldwide , -0504 Application Note Thermostat Demo Using the eZ80Acclaim!TM MCU iii Table of Contents List of Figures . . , . . . . . . . . . . . 2 3 3 5 Thermostat Implementation Using eZ80Acclaim!TM . . . . . . . , . . . . . . . . . . . . . . . . . . . . 8 Adding and Integrating Thermostat Demo Files to ZTP . . . , . . . . . . . . . 25 AN016804-0504 Table of Contents Application Note Thermostat Demo


Original
PDF eZ80Acclaim AN016804-0504 temperature controlled fan project temperature controlled fan project report sensor thermostat tm MAX6625 PUG0014 PUG0015 RM0008 UM0144 abstract on RTOS and multitasking
2008 - C7189U

Abstract: t7770a1006 NTC 20K honeywell T7770A HOT AIR oil furnace wiring diagram TB8220U C7089U T7770A3002 wiring diagram for dual pump control thermostat rc
Text: TB8220U Commercial VisionPROTM Programmable Thermostat INSTALLATION INSTRUCTIONS APPLICATION The TB8220U Programmable Thermostat provides electronic control of 24 Vac heating and cooling systems. See Table 1 for a description. Table 1. TB8220U Thermostat Description. Feature Description , equipment circuitry. Disconnect power supply before installation. Select Thermostat Location Select a location for the thermostat about 5 ft (1.5m) above the floor in an area with good air circulation at


Original
PDF TB8220U TB8220U C7189U t7770a1006 NTC 20K honeywell T7770A HOT AIR oil furnace wiring diagram C7089U T7770A3002 wiring diagram for dual pump control thermostat rc
Supplyframe Tracking Pixel