The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
AD-5000-TINEL-ASSY TE Connectivity Ltd GMBH THERMOFIT CV-
795257-000 TE Connectivity Ltd GMBH THERMOFIT CV-
411993-000 TE Connectivity Ltd GMBH THERMOFIT CV-
AD-5000-TINEL-HAND-TOOL TE Connectivity Ltd GMBH THERMOFIT CV-
AD-5000-TINEL-COND-ELECT TE Connectivity Ltd GMBH THERMOFIT CV-
747235-000 TE Connectivity Ltd GMBH THERMOFIT CV-

thermofit Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
RT-1050

Abstract:
Text: This Issue: Date: Replaces: RT-1050/6 Issue 4 May 14, 1999 Issue 3 THERMOFITÂ ® ADHESIVE AND SEALANT THERMOFIT S-1030 Thermofit S-1030 is a general purpose, flexible, thermoplastic adhesive based , control drawings. This material was developed to bond Thermofit heatshrinkable products where flexibility is desired at low temperatures. Thermofit S-1030 adhesive bonds to many materials such as , ) Pass Fungus Resistance 1 METHOD OF TEST Rating of 1 or less Use Thermofit RNF-100 to


Original
PDF RT-1050/6 S-1030 S-1030 RT-1050/6, RT-1050
PC437

Abstract:
Text: Tyco Electronics Corporation 300 Constitution Drive Menlo Park, CA 94025 USA Specification This Issue: Date: Replaces: RT-1050/13 Issue 3 September 13, 1996 Issue 2 THERMOFITÂ ® ADHESIVE AND SEALANT THERMOFIT S-1124 Thermofit S-1124 is a flexible adhesive based on elastomeric polymers. This adhesive was developed for use with Thermofit heat-shrinkable products, NT, NT-FR, and Elastomeric Polymer Blend (EPB). This adhesive provides good bonds of the heat-shrinkable materials to metals


Original
PDF RT-1050/13 S-1124 S-1124 RT-1050/13, RT-510 RT-511 RT-1321 PC437
thermofit

Abstract:
Text: Thermofit ® Molded Parts 342A012 to 058 45° side-breakout transition As supplied (a) After unrestricted recovery (b) P HW H dia. T U Injection port JW J dia. H dia. J dia. 3 KW K dia. Vent port K dia. Applications Provides strain relief and mechanical protection on cable harness assemblies. Materials Available Material ­3 ­4 ­5 ­6 ­12 ­25 Material , (203.5) KW ±20% b .04 (1.04) .04 (1.02) .06 (1.52) .06 (1.52) .10 (2.54) Thermofit is a


Original
PDF 342A012 S-1017 S-1048 S-1030 S-1048 342A012 thermofit polyolefin elastomer S1048
RAYCHEM thermogun CV-5300

Abstract:
Text: of each Item #1 and Item #2. 3. Parts are to be installed per Thermofit Assembly Procedure, see , referenced herein. THERMOFIT ASSEMBLY PROCEDURE 1.0 SCOPE This document outlines the procedure to be followed to obtain immersion resistant 3 or 2 to 1 in-line splices using Thermofit In-Line Splice Sealing


Original
PDF MIL-T-10727, D-436-52 D-436-53 D001302 D-436-52/-53 05-Dec RAYCHEM thermogun CV-5300 thermogun Raychem splice tool Raychem splice CV-5300 thermofit CV-4504 raychem SEALING END thermogun raychem MIL-T-10727
thermofit

Abstract:
Text: Thermofit ® Molded Parts 382A012 to 046 Y Transition As supplied (a) After unrestricted recovery (b) JW J dia. S J dia. H dia. HW T H dia. KW 3 K dia. K dia. Vent port Injection port Applications Provides strain relief and mechanical protection on cable harness assemblies. Materials Available Material ­3 ­4 ­5 ­6 ­12 ­25 Material description , (13.2) 1.06 (26.9) 1.06 (26.9) Thermofit is a registered trademark of Raychem Corporation. VITON


Original
PDF 382A012 S-1017 S-1048 S-1030 S-1048 382Aroduct thermofit thermofit molded raychem S1030 raychem S1048 382A034
RT-1050

Abstract:
Text: This Issue: Date: Replaces: RT-1050/3 Issue 4 March 3, 1997 Issue 3 Thermofit ® Adhesive and Sealant Thermofit S-1048 Thermofit S-1048 thermoplastic adhesive is a special high performance , material was developed for precoating the bonding areas of Thermofit heat-shrinkable parts. It is supplied , document is printed it becomes uncontrolled. Check for the latest revision. Use Thermofit RNF-100 Thermofit NT-FR 2024-T3 or equivalent ASA-B36.10-1939 Page 4 SPECIFICATION RT-1050/3, Issue 4 B


Original
PDF RT-1050/3 S-1048 S-1048 RT-1050/3, RT-1050
RAYCHEM thermogun CV-5300

Abstract:
Text: are to be installed per Thermofit Assembly Procedure, see below. 4. Inside diameter and outside , -7928. 7. This document takes precedence over documents referenced herein. THERMOFIT ASSEMBLY PROCEDURE , to 1 in-line splices using Thermofit In-Line Splice Sealing System D-436-85/-87. 2.0 PROCEDURE


Original
PDF QQ-N-290. D-436-85 D-436-86 60FIED D001297 D-436-85/-87 05-Dec RAYCHEM thermogun CV-5300 CV-4504 MIL-T-7928 thermogun 500A Raychem splice tool thermogun thermogun raychem thermofit raychem cv-5300 ad 1377 crimp tool
thermofit

Abstract:
Text: Thermofit ® Molded Parts 462A011 to 060 Transition, one to three cables As supplied (a) After unrestricted recovery (b) P J dia. T HW J dia. H dia. K dia. U KW typ. K dia. H dia. L dia. 3 Vent port Injection port L dia. Applications Provides strain relief and mechanical protection on cable harness assemblies. Materials Available Material ­3 ­4 , (192.0) 15.37 (390.4) KW ±10% b .04 (1.02) 1.30 (33.0) P ±10% b .18 (4.57) Thermofit


Original
PDF 462A011 S-1017 S-1048 S-1030 S-1048 thermofit 426A011 thermofit molded
thermofit insulation

Abstract:
Text: results, prepare the cable as shown: THERMOFIT DEVICES Raychem Corporation 300 Constitution Drive , trademark of Raychem Corporation. THERMOFIT DEVICES Raychem Corporation 300 Constitution Drive Menlo


Original
PDF B-053-70-05 J-STD-006. J-STD-004. D981066 SO639030 thermofit insulation thermofit B-053-70
Not Available

Abstract:
Text: Thermofit Tubing Specification Control Drawing No: Rev: Date: Page: MT3000 A October 30, 1996 1 of 2 AlteraTM MT3000 Flexible, Modified Fluoropolymer, Heat - Shrinkable Tubing This specification covers the requirements for one type of single wall, flexible, electrical insulating, extruded tubing whose diameter will reduce to a predetermined size upon application of heat in excess of 150° C , uncontrolled. Check with the web for latest revision. Thermofit Tubing Specification Control Drawing No


Original
PDF MT3000
Not Available

Abstract:
Text: Tyco Electronics Corporation 300 Constitution Drive Menlo Park, CA 94025 USA Specification This Issue: Date: Replaces: RT-1050/1 Issue 2 February 26, 1997 Issue 1 THERMOFITÂ ® ADHESIVE AND SEALANT THERMOFIT S-1017 Thermofit S-1017 thermoplastic adhesive was developed for use with Thermofit heat-shrinkable products where the molded part or tubing is precoated with adhesive on the bonding area. This adhesive is tough and flexible and bonds to polyolefins, vinyls, neoprene, lead, and


Original
PDF RT-1050/1 S-1017 S-1017 MIL-H-5606) Mil-L-7808) RT-1050/1,
thermofit

Abstract:
Text: Thermofit ® Molded Parts 562A011 to 067 Transitions, one to four cables As supplied (a) After unrestricted recovery (b) W K dia. J dia. J dia. T HW U K dia. H dia. H dia. N dia. L dia. Vent port 3 L dia. Injection port N dia. P Applications Provides strain relief and mechanical protection on cable harness assemblies. Materials Available , (1.02) .04 (1.02) .06 (1.52) .06 (1.52) .07 (1.78) .10 (2.54) Thermofit is a registered


Original
PDF 562A011 S-1017 S-1048 S-1030 S-1048 562A011 thermofit thermofit molded
Raychem splice tool

Abstract:
Text: wire TITLE : 300 Constitution Drive Menlo Park, CA 94025, USA THERMOFIT DEVICES (22 ­ 16 , Constitution Drive Menlo Park, CA 94025, USA THERMOFIT DEVICES (22 ­ 16 GAUGE) IN-LINE SPLICE SEALING


Original
PDF D-436-0133 D001281 14-Nov Raychem splice tool alumel D-436-0133 chromel thermofit insulation 1-322325-0 splice splice conductors
S1052

Abstract:
Text:  Thermofit Molded Parts Specification Control Drawing Part Number : Description : 382A012 thru 046 Transition, Y NOTES 1. All dimensions are in : [millimeters] 2. Dimensions appearing in table are as follows: a - As Supplied b - After Unrestricted Recovery 3. Coating is optional. As supplied dimensions appearing in table are for uncoated parts. When coating is added, entry diameters will be reduced , Description : 382A012 thru 046 Transition, Y Thermofit Molded Parts Specification Control Drawing Part


OCR Scan
PDF 382A012 S-1017; S-1048 S-1030 382A0XX 29MAR11 MP94214 S1052 RT1323 RT-1304 RT-1325 polyolefin elastomer THERMOFIT MOLDED PARTS RT1325 S-1052
thermofit

Abstract:
Text: Thermofit ® Molded Parts 301A011 to 048 T Transition As supplied (a) After unrestricted recovery (b) Injection port P K dia. W S J dia. 3 J dia. K dia. H dia. T Vent port H dia. Applications Provides strain relief and mechanical protection on cable harness assemblies. Materials Available Material ­3 ­4 ­5 ­12 ­25 Material description Semirigid , (55.6) Max. b .14 (3.6) .27 (6.9) .53 (13.5) 1.19 (30.2) Thermofit is a registered trademark


Original
PDF 301A011 S-1017 S-1048 S-1030 S-1048 301A011 thermofit thermofit molded 302A022 301A034 302A0 raychem S1030
000w212

Abstract:
Text: ® Thermofit Molded Parts P a rt S p ecificatio n Control Drawing Lim ited D istrib u tio n Num ber D e s c rip tio n ZOZK 16 3-2 5 -0 2 /2 2 5 B o o t. : S t r a ig h t W ith Lip NOTES 1. All dimensions are in inches Imillimeters) 2. Dimensions appearing in table are as follows: a - As Supplied b - After Unrestricted Recovery 3. Coating is optional. As , h t W ith Lip Thermofit Molded Parts P a r t Num ber S p ecificatio n Control Drawing


OCR Scan
PDF 000W212) QO-P-416 MP9235 000w212
Raychem splice tool

Abstract:
Text: assembly of one of each Item #1 and Item #2. 3. Parts are to be installed per Thermofit Assembly Procedure , referenced herein. THERMOFIT ASSEMBLY PROCEDURE 1.0 SCOPE This document outlines the procedure to be followed to obtain immersion resistant 3 or 2 to 1 in-line splices using Thermofit In-Line Splice Sealing


Original
PDF MIL-T-10727, D-436-52 D-436-53 D-436-52/-53 15-Apr-11 D001302 9-May-11 Raychem splice tool MIL-T-7928 raychem AD-1377 Raychem splice inspection thermofit CV-4504 thermogun 500A B 660 TG thermogun 500A raychem
D-436-39

Abstract:
Text: Specification Drawings D-436-39 and D-436-40. THERMOFIT DEVICES 300 Constitution Drive Menlo Park, CA 94025 , encapsulated. THERMOFIT DEVICES 300 Constitution Drive Menlo Park, CA 94025, USA TITLE: SEALING


Original
PDF D-436-39f D-436-41 D000565 02-Oct-00 D-436-39 D-436-41 thermogun 500A raychem thermogun 500A D-436-40 thermofit insulation
2004 - MIL-PRF-87257

Abstract:
Text: , and approximately 1 foot long, with a Thermofit Model 500B Thermogun* or equivalent. Cool to room , procedure, except use NTFR* tubing. Polyvinylchloride Repeat above procedure, except use Thermofit PVC


Original
PDF S-1017) SAS-090-038-1017 SAS-090-075-1017 SAS-090-1-1017 SAS-115-075-1017 SAS-115-1-1017 SAS-160-075-1017 SAS-160-1-1017 SAS-200-075-1017 SAS-200-1-1017 MIL-PRF-87257 MIL-PRF-83282 MIL-PRF-7808L sas20011 sleeve rnf-100 RAYCHEM RNF-100
RT1325

Abstract:
Text:  Thermofit Molded Parts Specification Control Drawing Part Number : 202D211 thru 299 Description : Boot, Straight With Lip NOTES . ,. , . inches 1. All dimensions are in - [millimeters] 2. Dimensions appearing in table are as follows: a - As Supplied b - After Unrestricted Recovery 3. Coating is optional. As supplied dimensions appearing in table are for uncoated parts. When coating is , : : N1 29MAR11 Part Number : Description : 202D211 thru 299 Boot, Straight With Lip Thermofit Molded


OCR Scan
PDF 202D211 t4-57] RW-20D8 S-1017; RT-1323 S-104B; S-1030 29MAR11 RT1325 RT-301 202D2 RT-1325
RNF-100

Abstract:
Text: _ _ t ec o n n e c t t y Thermofit Division Europe Specification Control Drawing RNF100 Dimensions (in millimetres) Part Number ·inside Diameter D (min) d (max) Expanded Recovered as supplied after heating Wall Thickness W (nom) Recovered after heating RNF100 NR.541 RNF100 H R .610 RNF 100 NR. 541 RNF 100 NR. 610 6.0 5.3 1 i6 1.6 0.5 0.5 Available in colours only (not clear) Available in colours, and clear.


OCR Scan
PDF RNF100 RNF100 RNF-100
D-436-0154

Abstract:
Text: range: -55°C to +150°C. THERMOFIT DEVICES Raychem Corporation 300 Constitution Drive Menlo Park


Original
PDF D-436-0154 D-436-0154 D981323 D980267 thermofit insulation thermofit
MIL-S-81824

Abstract:
Text: . TITLE : 300 Constitution Drive Menlo Park, CA 94025, USA THERMOFIT DEVICES (5 at 2.03 (0.080


Original
PDF MIL-T-10727, MIL-S-81824/1. D-436-0127 D001279 14-Nov MIL-S-81824 low outgassing materials 81824 splice D-436-0127 Outgassing Raychem splice
Not Available

Abstract:
Text: : copper, nickel plated. Gasket and seal rings: silicone rubber Heat-shrink tubing: thermofit plastic


OCR Scan
PDF 50GHz. 50GHz 5000M 5-50GHZ
thermofit

Abstract:
Text: spec/std : MIL-C-24308 Heat-shrink tubing: thermofit plastic. 1.15~1.45 4.75~4.78 2.45~2.5


Original
PDF DSA-75 DSA-75 MIL-C-24308 25max 72bing: thermofit
Supplyframe Tracking Pixel