The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
LTK001ACJ8 Linear Technology IC THERMOCOUPL COMP& KIT 8DIP
LTK001CJ8 Linear Technology IC THERMOCOUPL COMP& KIT 8DIP
LT1025CS8#TRPBF Linear Technology LT1025 - Micropower Thermocouple Cold Junction Compensator; Package: SO; Pins: 8; Temperature Range: 0°C to 70°C
LT1025CN8 Linear Technology LT1025 - Micropower Thermocouple Cold Junction Compensator; Package: PDIP; Pins: 8; Temperature Range: 0°C to 70°C
LT1025CS8#TR Linear Technology LT1025 - Micropower Thermocouple Cold Junction Compensator; Package: SO; Pins: 8; Temperature Range: 0°C to 70°C
LT1025CS8 Linear Technology LT1025 - Micropower Thermocouple Cold Junction Compensator; Package: SO; Pins: 8; Temperature Range: 0°C to 70°C

thermocouple type K krupp Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
1993 - RS 610-067

Abstract:
Text: review the type N thermocouple is not merely an For these reasons type K thermocouples are improved , type K but any nickel characteristics of a particular melt. Consequently, based thermocouple . there , K and N but with type N a simple vary from thermocouple to thermocouple . Unknown solution is , type K but are the best combination of elements giving optimum results for a thermocouple based on , formation of silicates on the surface of the wires, these form 4 E15248 Type K , N and J thermocouple


Original
PDF E15248 BS4937: 150mm RS 610-067 BS4937 RS 611-234 BS1843 160-540 150004 158-525 Thermocouple Type K 612-855 Thermocouple Type L
Thermocouple Type K material

Abstract:
Text: THERMOCOUPLE & RESISTANCE THERMOMETER CONNECTORS TYPE J K T N E R/S Copper , , K & N TYPE J K N Duplex (Two channel) connectors using thermocouple , Type K Type T Type N Type E Type R Type S THERMOCOUPLE & RESISTANCE THERMOMETER , www.labfacility.co.uk Type J Type K Type T Type N Type E Type R Type S 7 THERMOCOUPLE & , Thermocouple type J, K or T to IEC 60584. Exposed, Welded junction. Tip temperature Rating -75°C to 250


Original
PDF
2013 - M12-K

Abstract:
Text: .* M12-K-(*)-M-FM Thermocouple Type Positive Terminal Negative Terminal K Chromel Pin , . Description M12-K-R-M-FM Type K thermocouple right angled M12 male connector M12-J-R-M-FM Type J , connector M12-E-R-M-FM Type E thermocouple right angled M12 male connector M12-K-S-M-FM Type K , M12 male connector M12-K-R-F-FM Type K thermocouple right angled M12 female (socket) connector , female (socket) connector M12-K-S-F-FM Type K thermocouple straight M12 female (socket) connector


Original
PDF M12-FM M12-J-S-F-FM 24AWG M12-J-R-F-FM M12-T-R-F-FM M12-E-R-F-FM M12-K-S-F-FM M12-T-S-F-FM M12-E-S-F-FM M12-K
1998 - 219-4315

Abstract:
Text: the measurement junction of the thermocouple . Figure 3 Typical temperature gradient for type K , oxidisation and hence change in EMF. A type K thermocouple will eventually fail mechanically when the wire is , thermocouple which, as far as possible, overcomes all the disadvantages of not only type K but any nickel based thermocouple . Minerally insulated type K thermocouples can suffer other problems which are shared by type N , . 257-284 Digital temperature indicator Panel mounting digital indicators Type K , N and J thermocouple


Original
PDF
1995 - Omega k type thermocouple range

Abstract:
Text: temperature for several thermocouple types The K type is the most linear while the S type is one of the , ( type K ) thermocouple is the most linear With this type a compensation accuracy of g C can be obtained , Junction TABLE I Nonlinearity Error of Thermometer Using Type K Thermocouple (Scale Factor 25 47 C mV , C temperature range using J or K type thermocouples In addition a thermocouple amplifier using an , temperature range can be obtained with any thermocouple type by the proper adjustment of voltage TC and


Original
PDF
Thermocouple color

Abstract:
Text: J, K , T, and E types Accessories RTDs Thermocouple plugs (J, K , T, E) Spring-loaded , available for J, K , T, and E type thermocouples. RTDs RTDs are popular for high-accuracy temperature , Thermocouple Miniconnector Plugs (Quantity 10) J type .745688-J10 K type .745688-K10 T type , Ready-Made Thermocouple Calibrations Thermocouple Characteristics Extension Wire Calibration J type


Original
PDF 745690-K002 Thermocouple color thermocouples sensors Thermocouple Type K k type thermocouple 745686-01 745685-T02 K001 745690-T002 thermocouple j type thermocouple sensor
1995 - temperature controller of general split air conditioner

Abstract:
Text: amplifies a type J or K thermocouple input to derive an internal signal proportional to temperature. The , from a type J or K thermocouple signal. It can also be used as a stand-alone voltage output temperature , Quiescent Current +VS ­VS NOTES 1 (@ +60C and VS = 10 V, Type J (AD596), Type K (AD597) Thermocouple , . The different temperature ranges are due to the differences in J and K type thermocouple curves , BACK a FEATURES Low Cost Operates with Type J (AD596) or Type K (AD597) Thermocouples Built-In


Original
PDF AD596) AD597) AD596 /AD597* AD596/AD597 O-100 C831a temperature controller of general split air conditioner
1995 - circuit diagram of general split air conditioner

Abstract:
Text: amplifies a type J or K thermocouple input to derive an internal signal proportional to temperature. The , from a type J or K thermocouple signal. It can also be used as a stand-alone voltage output , = 10 V, Type J (AD596), Type K (AD597) Thermocouple , AD596/AD597­SPECIFICATIONS unless otherwise , different temperature ranges are due to the differences in J and K type thermocouple curves. European DIN , a FEATURES Low Cost Operates with Type J (AD596) or Type K (AD597) Thermocouples Built-In Ice


Original
PDF AD596) AD597) AD596 /AD597* AD596/AD597 C831a AD596/AD597 O-100 circuit diagram of general split air conditioner AD595 thermocouple AD597 Thermocouple Type K AD597AH AD597A AD596AH AD595 AD594
2002 - allen bradley potentiometer type j

Abstract:
Text: plotted as a function of temperature for several thermocouple types. The K type is the most linear , °C. Thermocouple nonlinearity results in additional compensation error. The chromel/alumel ( type K ) thermocouple , Junction TABLE 1. Nonlinearity Error of Thermometer Using Type K Thermocouple (Scale Factor 25.47°C/µV , °C temperature range using J or K type thermocouples. In addition, a thermocouple amplifier using an LM335 for , divide down the 10 mV/° K output of the LM335 to match the Seebeck coefficient of the thermocouple . The


Original
PDF
2004 - chromel seebeck Table

Abstract:
Text: input of thermocouple type ( K , J, or T) and temperature display is via the DEBUG window. ' - , temperature will be incorrect. Type K J T Materials Chromel / Alumel Iron / Constantan Copper , , "=", CR, CR, "Select TC Type (1 - 3)", CR, CR, "(1) K - Chromel/Alumel", CR, "(2) J - Iron , 4.7 k Vin IS1 0.1 µF 8 Parallax, Inc. · DS2760 Thermocouple Kit (#28022) · 01/2004 , Educational: www.stampsinclass.com DS2760 Thermocouple Kit (#28022) 1-Wire® Thermocouple Interface


Original
PDF DS2760 pk/2931 DS2760 chromel seebeck Table chromel alumel seebeck parallax ds2760 bs2pe T type thermocouple constantan seebeck Table thermocouple 1-wire thermocouple Parallax
1998 - linear application handbook national semiconductor

Abstract:
Text: compensation error. The chromel/alumel ( type K ) thermocouple is the most linear. With this type , a , -4 Thermocouple R1 Seebeck Type () Coefficient J 377 52.3 T 308 42.8 K 293 , Error of Thermometer Using Type K Thermocouple (Scale Factor 25.47°C/µV) °C Error (°C) °C , K type is the most linear, while the S type is one of the least linear. When using an absolute , thermocouple is almost as good. To keep the error small for the less linear S and T type thermocouples, the


Original
PDF an007471 linear application handbook national semiconductor thermocouples sensors Linear Thermometer ic omega power amplifier circuit Cold Junction Compensation Thermocouple Type K J type thermocouple Omega k type thermocouple range calibration procedure for thermocouple Transistor lm335
1999 - AD595

Abstract:
Text: Pretrimmed for Type J (AD594) or Type K (AD595) Thermocouples Can Be Used with Type T Thermocouple Inputs , VS = 5 V, Type J (AD594), Type K (AD595) Thermocouple , AD594/AD595­SPECIFICATIONS unless otherwise , and a DIN thermocouple table should be used. ANSI type K and DIN NICR-NI thermocouples are composed , (AD594) or type K thermocouple (AD595) measuring from 0°C to +300°C. Figure 1. Basic Connection , trimmed for type K (chromel-alumel) inputs. The temperature transducer voltages and gain control


Original
PDF AD594/AD595 AD594) AD595) O-116 AD595 AD595 thermocouple NICR-NI thermocouple ice point compensation feedback thermocouple calibration procedure for thermocouple AD595C AD595A AD595 IC PIN LAYOUT Thermocouple Type K AD594AD
ANSI MC96.1-1982

Abstract:
Text: Thermocouple Insulated Softwire Standard Lengths Type J K T E KX* ANSI Color Coded Thermocouple , Catalog# Length Inches Inches 21253 Ungrounded Junction This type of thermocouple junction is fully , .1-1982. For thermoelectric voltage information please refer to the following pages. Type J K Quick , 0.00385 standard tolerance class B. Type J K RTD ANSI Color Code Black Yellow White Max , 900-1600F (482-871F) range. Ungrounded Junction This type of thermocouple junction is fully insulated


Original
PDF 1382F 2282F 1250C 1652F 1000F 1300F 1600F ANSI MC96.1-1982 538C Thermocouple color thermocouple k type thermocouple length THK105 THJ315 THJ105 THJ1015 dupont teflon platinum
1999 - AD595 thermocouple

Abstract:
Text: Pretrimmed for Type J (AD594) or Type K (AD595) Thermocouples Can Be Used with Type T Thermocouple Inputs , VS = 5 V, Type J (AD594), Type K (AD595) Thermocouple , AD594/AD595­SPECIFICATIONS unless otherwise , and a DIN thermocouple table should be used. ANSI type K and DIN NICR-NI thermocouples are composed , (AD594) or type K thermocouple (AD595) measuring from 0°C to +300°C. Figure 1. Basic Connection , trimmed for type K (chromel-alumel) inputs. The temperature transducer voltages and gain control


Original
PDF AD594/AD595 AD594) AD595) O-116 AD595 thermocouple k thermocouple amplification circuit diagram ice point compensation feedback thermocouple AD595 IC PIN LAYOUT AD595 R type thermocouple AD594AD AD595-SPECIFICATIONS AD595A AD595C
30AWG 1C

Abstract:
Text: Thermocouple Wires 100' coils of insulated 24-AWG thermocouple wire Type K Range: +32°F to +545°F (0°C to , Thermocouple Type K w/ connector TCP6-K12 $35 Initial Range: Accuracy: +32°F to +559°F (0°C to +293°C , 100' of 24-AWG Thermocouple Wire Type J TCW100-J Type K TCW100-K Type T TCW100-T $55 $55 , connectors and plug directly into HOBO® Thermocouple Family loggers. The connectors are color-coded for type , , K , and T versions available Specifications Type J Range: +32°F to +482°F (0°C to +250°C) x


Original
PDF 30-AWG TCP6-K12 24-AWG TCW100-J TCW100-K TCW100-T 1-800-LOGGERS 30AWG 1C TCP6-K12 thermocouple connectors TCW100-K Thermocouple Type K k type thermocouple cable 537C 356f
1995 - NICR-NI thermocouple

Abstract:
Text: Pretrimmed for Type J (AD594} or Type K (AD595) Thermocouples Can Be Used with Type T Thermocouple Inputs , /326-8703 (@ + 25C and VS = 5 V, Type J (AD594), Type K (AD595) Thermocouple , AD594 , thermocouple table should be used. ANSI type K and DIN NICR-NI thermocouples are composed CONSTANTAN (ALUMEL , (AD594) or type K thermocouple (AD595) measuring from 0°C to +300°C. Any convenient supply voltage from , thermocouple leads. The AD594 is precalibrated by laser wafer trimming to match the characteristic of type


Original
PDF AD594 /AD595* AD594} AD595) AD594/AD595 O-116 NICR-NI thermocouple nicr-ni temperature Thermocouple Type K material 6790 pf 27 AD595A 680 ohms resistor 5 watt datasheet cold junction compensation of t type thermocouple AD595 thermocouple voltage transducer Linear Thermometer ic
1997 - and application AD595

Abstract:
Text: ­55 Indefinite (@ + 25C and VS = 5 V, Type J (AD594), Type K (AD595) Thermocouple , AD595A Typ Max , provide a direct output from a type J thermocouple (AD594) or type K thermocouple (AD595) measuring from 0 , BACK a FEATURES Pretrimmed for Type J (AD594) or Type K (AD595) Thermocouples Can Be Used with Type T Thermocouple Inputs Low Impedance Voltage Output: 10 mV/ C Built-In Ice Point Compensation Wide , characteristic of type J (iron-constantan) thermocouples and the AD595 is laser trimmed for type K


Original
PDF AD594) AD595) AD594/AD595 O-116 C731f and application AD595 7402 NOR gate ic pin configuration AD595 J type thermocouple
80PK-9

Abstract:
Text: -M type K & J Male Mini-Connectors Thermocouple Plug Kits 700TC1 Ideal for applications where , for K or J wire q Suitable for up to 20 guage thermocouple wire q Color coded to industry , Type K (yellow), one Type T (blue), one Type E (purple), one Type R/S (green), one Type B or CU , ) q 700TC2 A kit of 7 mini-plug connectors Type J (black), two Type K (yellow), two Type T , repairing J, K ot T-type thermocouple wires q Kit includes 3 meters of thermocouple wire and 1 pair of


Original
PDF 80PK-1 80PJ-1 80PK-1 80PK-5A 80PT-5A 80PK-8 80PK-5A 80PK-9 Thermocouple Type L
Thermocouple K bead type

Abstract:
Text: mini-plug connectors Type J (black), two Type K (yellow), two Type E (purple), one Type T (blue), one Type R/S (green), one · Extending and repairing J, K ot T-type thermocouple wires · Kit includes 3 , Accessories Other Temperature Accessories 80PR-60 RTD Temperature Probe 80CK-M & 80CJ-M type K & J Male , (black), one Type K (yellow), one Type T (blue), one Type E (purple), one Type R/S (green), one Type , Type N (orange), one 20 guage thermocouple wire Color coded to industry standards (K-yellow


Original
PDF 80PK-22 80PK-1 80PJ-1 80PK-1: 80PK-24 741B/743B/744 845A/8846A 80PK-1 80PK-27 Thermocouple K bead type FLUKE 43B 80PK-25 80T-150U 80PK-9 FLUKE 8846A thermocouple type-k Thermocouple color
1999 - chromel seebeck Table

Abstract:
Text: Figure 15. A Type K thermocouple is chosen for this circuit because of its stable Seebeck Coefficient , input of the instrumentation amplifier would be 43.72mV for the combination of the Type K thermocouple , combination of the Type K thermocouple and the thermistor error correction circuitry. The inverting input of , 40.494 40.885 41.276 TABLE 6: Type K thermocouple output voltage look-up table. All values in , % Rhodium) (+) Platinum (-) 0 to 1480 7µV/°C oxidizing, inert Thermocouple Type Conductors


Original
PDF AN684 AN679, chromel seebeck Table MTS102 - silicon temperature sensor second order low pass filter advantage and disadvantages thermistor ntc characteristic 40k ntc thermistor 10k MTS105 chromel seebeck Temperature Thermocouple Type K material testing RTD CIRCUITS MTS102
1998 - chromel seebeck Table

Abstract:
Text: accurate thermocouple circuit is achievable by using the circuit shown in Figure 15. A Type K thermocouple , instrumentation amplifier would be 43.72mV for the combination of the Type K thermocouple offset at 750°C (per , 41.276 TABLE 6: Type K thermocouple output voltage look-up table. All values in the table are in , . Thermocouple Type E J K R S T Range 0° to 1000°C 0° to 760°C 0° to 500°C -50° to , Thermocouple Type Conductors E Application Environments TABLE 1: Common thermocouple types-The


Original
PDF AN684 AN679, DS00684A-page chromel seebeck Table monograph 175 Golden motor 10kw IPTS90 MCP601 comparator RTD CIRCUITS D2063 "rtd circuits" mts102 Thermocouple Type K material testing
2004 - ABB Pt100 3 wire

Abstract:
Text: -wire Voltage 1) 2 Measuring range Sensor Thermocouple type B Thermocouple type E Thermocouple type J Thermocouple type K Thermocouple type R Thermocouple type S Thermocouple type T Thermocouple , 0.2 K p. a. Thermocouple e. g. type K voltage measurement -100 mV.+1200 mV - 75 mV.+ 75 mV , (100 % humidity with isolated terminals only) Condensation permitted Thermocouple e. g. type K , Thermocouple measurement > 5 k Voltage measurement > 5 k 2 x AI (s) other function blocks 1 x RB (s


Original
PDF TF02/TF02-Ex ABB Pt100 3 wire pt100 temperature sensor circuit diagram TF02 Ni100 sensor 455 3968 PT100 PT100 temperature sensor ABB PT100 ABB ABB thermocouple pt100 4 wire BUZH, Aluminum
2002 - AN844

Abstract:
Text: Bytes · J - type thermocouple · K - type thermocouple · TC1046A The TC1046A has linear output, but , 9.76 K + 10 K + - + Output Thermocouple RG 10 K 10 K 100 10 K - 19.1 K 10 K + 1 K VREF 2.5 V Offset Adjust 2.5 K In the analog solution, the thermocouple , linear and it is not the same for each type of thermocouple . Figure 5 shows a rough approximation of the family of thermocouple transfer functions. THERMOCOUPLE TRANSFER FUNCTIONS 80 E 70 60 K


Original
PDF AN844 AN684, AN684 D-81739 DS00844A-page AN844 circuit far thermocouple interface with adc thermocouple to pic interface transistor tic 2260 thermocouple microchip AN-844 thermocouple to digital interface nonlinear circuits handbook Amplifier k thermocouple texas
2004 - 1746-NT4

Abstract:
Text: Thermocouple Restrictions J Type Thermocouple . . . . . . . . . . . . . . . . . (Iron vs. Copper-Nickel ) . . K Type Thermocouple . . . . . . . . . . . . . . . . (NIckel-Chromium vs. Nickel-Aluminum) T Type Thermocouple . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . , . . . . . . . . Input Resolution per Thermocouple Type at Each Filter Frequency . . . . . . . . . , Type Thermocouple . . . . . . . . . . . . . . . . . . . . . . . . . . (Nickel-Chromium vs


Original
PDF 1746-NT4, 1746-UM007C-EN-P 1746-UM007B-EN-P 1746-NT4 RSLOGIX 500 LADDER 1747-NT4 1747-AIC SLC-500 1746-IN010 1746-TD003 T type thermocouple 1747-UM011 2081 0000 02 A196
AD597AR2

Abstract:
Text: ) directly from a type J or K thermocouple signal. It can also be used as a stand-alone voltage output , are due to the differences in J and K type thermocouple curves. European DIN FE-CuNi thermocouple vary , ANALOG DEVICES FEATURES Low Cost Operates with Type J (A0596I or Type K (AD597) Thermocouples , compensates and amplifies a type J or K ther mocouple input to derive an internal signal proportional to , AD597 can accommodate -20G°C to + 1250"C type K inputs. The AD596/AD597 has a calibration accuracy of


OCR Scan
PDF A0596I AD597) AD596/AD597 AD597AR2 1262 thermometer A0596 ADS96 LM 4138 LM 8569 Thermocouple K TYPE CIRCUIT
Supplyframe Tracking Pixel