The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
EL4501IU-T13 Intersil Corporation SPECIALTY CONSUMER CIRCUIT, PDSO24, QSOP-24
EL4501IU Intersil Corporation SPECIALTY CONSUMER CIRCUIT, PDSO24, QSOP-24
EL9110IU Intersil Corporation LINE RECEIVER, PDSO16, PLASTIC, QSOP-16
EL4501IU-T7 Intersil Corporation SPECIALTY CONSUMER CIRCUIT, PDSO24, QSOP-24
EL9110IU-T7 Intersil Corporation LINE RECEIVER, PDSO16, PLASTIC, QSOP-16
EL9110IU-T13 Intersil Corporation LINE RECEIVER, PDSO16, PLASTIC, QSOP-16

telemecanique contactor SIZE 1 Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
1995 - telemecanique contactor catalogue

Abstract: telemecanique VDE 0660 telemecanique DOL motor starter IEC 292-1 telemecanique LC1 telemecanique lc1 contactor catalogue telemecanique thermal overload relay telemecanique contactor catalogue LC1 contactor telemecanique LC1 Telemecanique MOTOR STARTER table
Text: 2.2 4 4 4 5.5 4 7.5 7.5 7.5 9 9 9 10 - Contactor LC1. LP1 Size 09 09 09 09 09 , Telemecanique `d2' range A range of 4 and 9kW direct on line ac starters using the new Telemecanique `d2' , overload see current RS catalogue or Telemecanique `d2' motor control gear data sheet or the table , contactor ; similarly the 9kW starter can be up rated to 11kW q Each enclosure has four plugged threaded , and fuses for standard squirrel cage motors Standard power for three phase motors ( 1 ) 50/60 Hz in


Original
PDF BS4941 2xPE16 telemecanique contactor catalogue telemecanique VDE 0660 telemecanique DOL motor starter IEC 292-1 telemecanique LC1 telemecanique lc1 contactor catalogue telemecanique thermal overload relay telemecanique contactor catalogue LC1 contactor telemecanique LC1 Telemecanique MOTOR STARTER table
1991 - telemecanique contactor catalogue

Abstract: telemecanique contactor SIZE 1 telemecanique LC1 Telemecanique MOTOR STARTER table IEC 292-1 3 phase Overload Telemecanique telemecanique thermal overload relay LP1 CONTACTOR TELEMECANIQUE telemecanique DOL motor starter "IEC 292-1"
Text: = = = Telemecanique M 8 Earth bar 88 1 P 140 and tag 2xPE13 2 T1 4 T2 , Issued November 1991 B12570 Direct on line (DOL) starters Telemecanique ‘d2’ range A range of 4 and 9kW direct on line ac starters using Features the new Telemecanique ‘d2’ motor control gear range , current RS catalogue or Telemecanique ‘d2’ motor control gear data sheet or the table provided l 4kW , starter has enough space and the correct configuration to be uprated to a 5.5kW contactor ; similarly the


Original
PDF B12570 BS4941 corr32 2xPE13 2xPE16 telemecanique contactor catalogue telemecanique contactor SIZE 1 telemecanique LC1 Telemecanique MOTOR STARTER table IEC 292-1 3 phase Overload Telemecanique telemecanique thermal overload relay LP1 CONTACTOR TELEMECANIQUE telemecanique DOL motor starter "IEC 292-1"
1997 - telemecanique contactor catalogue

Abstract: telemecanique LC1 telemecanique thermal overload relay telemecanique VDE 0660 telemecanique lc1 contactor catalogue contactor telemecanique LC1 Telemecanique MOTOR STARTER telemecanique contactor LC1 telemecanique DOL motor starter LP1 CONTACTOR TELEMECANIQUE
Text: 2.2 4 4 4 5.5 4 7.5 7.5 7.5 9 9 9 10 - Contactor LC1. LP1 Size 09 09 09 09 09 , Telemecanique `d2' range A range of 4 and 9kW direct on line ac starters using the new Telemecanique `d2' , overload see current RS catalogue or Telemecanique `d2' motor control gear data sheet or the table , contactor ; similarly the 9kW starter can be up rated to 11kW q Each enclosure has four plugged threaded , and fuses for standard squirrel cage motors Standard power for three phase motors ( 1 ) 50/60 Hz in


Original
PDF BS4941 circula135 2xPE16 telemecanique contactor catalogue telemecanique LC1 telemecanique thermal overload relay telemecanique VDE 0660 telemecanique lc1 contactor catalogue contactor telemecanique LC1 Telemecanique MOTOR STARTER telemecanique contactor LC1 telemecanique DOL motor starter LP1 CONTACTOR TELEMECANIQUE
LC1k06

Abstract: Telemecanique LC1k09 lp1k09 LC1K09 LP1K06 LP4K09 Telemecanique LC1k06 telemecanique ca2kn telemecanique contactors lc1-K09
Text: Telemecanique GV2-M and K range with spring terminals References GV2-M motor circuit breakers , 0.63 0.63 - 1 1 - 1.6 1.16 - 2.5 References GV2-M083 GV2-M103 GV2-M143 GV2-M163 GV2-M203 , mounting K range contactor for printed circuits K contactors Control Power Rating s AC s DC s Low consumption DC AC3, 3-phase 400/415 V AC3 max Ie (Ue <440 V) Reference ( 1 ) LC1-K06*3qq LP1-K06*3qq LP4-K06*3qq 2.2 6 Reference ( 1 ) LC1-K09*3qq LP1-K09*3qq LP5-K09*3qq 4 9


Original
PDF GV2-M013 GV2-M023 GV2-M033 GV2-M043 GV2-M053 GV2-M063 GV2-M073 400/415V GV2-M083 GV2-M103 LC1k06 Telemecanique LC1k09 lp1k09 LC1K09 LP1K06 LP4K09 Telemecanique LC1k06 telemecanique ca2kn telemecanique contactors lc1-K09
1995 - telemecanique contactor catalogue

Abstract: telemecanique star delta starter HRC fuse gg GEC bs88 zs levels mte axto overload NIT16 gec gec switchgear TIA32 mte max0 TIS63M80 curve
Text: 3 off DIN rail adaptors (optional) 414-213 1 off 'd' range contactor 9A-4kW 347-624 1 off 'd' , BS4941:Part 1 : 1979 (IEC292- 1 ) defines three levels of co-ordination between contactor , overload relay , 32, 35 40, 50 63, 80 100, or more Min. cable size to achieve short-circuit protection mm2 1 , carried out at maximum Type 'c' kW rating for each size of contactor . 2 Extrapolated overload relay and , Solid links Solid links are available for use as neutral links etc. Size 1 may be used in the A1


Original
PDF IEC269: RS20H RS32H RS63H RS100H telemecanique contactor catalogue telemecanique star delta starter HRC fuse gg GEC bs88 zs levels mte axto overload NIT16 gec gec switchgear TIA32 mte max0 TIS63M80 curve
1997 - telemecanique contactor catalogue

Abstract: telemecanique star delta starter bs88 zs levels HRC fuse gg GEC 15KW motor BS88-2 telemecanique star delta starter table BS88 fuse curve hbc NIT16 gec mte axto overload
Text: 3 off DIN rail adaptors (optional) 414-213 1 off 'd' range contactor 9A-4kW 347-624 1 off 'd' , BS4941:Part 1 : 1979 (IEC292- 1 ) defines three levels of co-ordination between contactor , overload relay , 32, 35 40, 50 63, 80 100, or more Min. cable size to achieve short-circuit protection mm2 1 , carried out at maximum Type 'c' kW rating for each size of contactor . 2 Extrapolated overload relay and , 413-939 415-092 - Solid links Solid links are available for use as neutral links etc. Size 1 may


Original
PDF IEC269: RS20H RS32H RS63H RS100H telemecanique contactor catalogue telemecanique star delta starter bs88 zs levels HRC fuse gg GEC 15KW motor BS88-2 telemecanique star delta starter table BS88 fuse curve hbc NIT16 gec mte axto overload
CA3KN31BD

Abstract: LA1DN11 telemecanique lc1d09 LC1K09 telemecanique D range contactors relays telemecanique LP1D0910BD Telemecanique LR2D1321 telemecanique contactors Telemecanique LC1k
Text: . Contactor 9A ­ 32A 40A ­ 63A 80A 12 Order code 1 + 5+ 10+ 20+ 4.90 7.90 7.90 , 240V 4kW contactor with 1NO contact Technical specification Function 1 NO and 1 NC auxiliary , NO + 1 NC 2 NO + 2 NC 1 NO + 3 NC 4 NC 3 NO + 1 NC 4 NO Camden Telemecanique A range of , , trip test indicator, pre-wired maintaining contact for connection into contactor and 1 NO and 1 NC , FL1A-H12RCE FL1A-H10RCA FL1A-H10RCB FL1A-B12RCE FL1A-B10RCA FL1A-B10RCB 1 + Order code 28-1200


Original
PDF UL94V-0 CIM/8W-D10 CIM/R4-WB-S-24 CIM/R8-WB-S-24 CIM/R16-WB-S-24 16-way CA3KN31BD LA1DN11 telemecanique lc1d09 LC1K09 telemecanique D range contactors relays telemecanique LP1D0910BD Telemecanique LR2D1321 telemecanique contactors Telemecanique LC1k
GV3-ME40

Abstract: Telemecanique GV3ME63 Motor Circuit Breaker GV3-ME63 RSHR4038CV20 rshr4045 GV3ME63 GV2-M22 Telemecanique circuit breaker GV3ME40
Text: / 40HP 45A: AC-53b: 4-5: 115 45A: AC-53b: 4-5: 135 45A: AC-53b: 4-5: 175 30/25/20 500mA 1 RSHR , maximum size solid finely stranded with end sleeve stranded UL/CSA rated data UL rated data CSA , according to IEC 60947 maximum size UL/CSA rated data Terminal screws Tightening torque Stripping , Form 1 Normally open (21,22) Normally closed (11, 22) 3 A, 250 VAC 3 A, 30 VDC Above 1000m derate linearly by 1 % of unit FLC per 100m to a maximum altitude of 2000m * detection of these alarm


Original
PDF AC-53b GV3-ME40 Telemecanique GV3ME63 Motor Circuit Breaker GV3-ME63 RSHR4038CV20 rshr4045 GV3ME63 GV2-M22 Telemecanique circuit breaker GV3ME40
1992 - telemecanique contactor catalogue

Abstract: HRC fuse gg GEC telemecanique thermal overload relay tripping curve telemecanique star delta starter mte thermal overload relay mte axto overload mte relay BS88 gM motor fuse what is type 2 coordination TIA16
Text: (optional) 414-213 The importance of co-ordination 1 off 'd' range contactor 9A-4kW 347-624 Correct , each size of contactor . 2 Extrapolated overload relay and fuse sizes for low kW ratings included in , accessories) Solid links are available for use as neutral links etc. Size 1 may be used in the A1 fuseholder , meet all the requirements of maximum dc voltages as tabulated IEC269: Parts 1 and 2: 1986 (and hence also the l ASTA certified in combination with motor control pending revisions of BS88: Parts 1 and 2).


Original
PDF B12659 IEC269: RS20H RS32H RS63H RS100H RS200H RS20H RS32H RS63H telemecanique contactor catalogue HRC fuse gg GEC telemecanique thermal overload relay tripping curve telemecanique star delta starter mte thermal overload relay mte axto overload mte relay BS88 gM motor fuse what is type 2 coordination TIA16
GV3-ME40

Abstract: GV3-ME63 Telemecanique GV3ME63 Motor Circuit Breaker GV3ME63 GV3ME40 RSHR4025CV20 telemecanique GV2-M22 Telemecanique circuit breaker GV3ME40 telemecanique thermal overload relay KTA3-25-25A
Text: : AC-53b: 4-5: 175 30/25/20 500mA 1 RSHR Conductor Data General Specifications Line conductors: L1, L2, L3/T1, T2, T3 according to IEC 60947 maximum size solid finely stranded with end , size UL/CSA rated data Terminal screws Tightening torque Stripping length Thermal , 4Hz) LED, red (blinking at 1.3Hz) Acc. to DIN 44081 and DIN 44082-1 Form 1 Normally open (21,22) Normally closed (11, 22) 3 A, 250 VAC 3 A, 30 VDC Above 1000m derate linearly by 1 % of unit FLC per


Original
PDF AC-53b GV3-ME40 GV3-ME63 Telemecanique GV3ME63 Motor Circuit Breaker GV3ME63 GV3ME40 RSHR4025CV20 telemecanique GV2-M22 Telemecanique circuit breaker GV3ME40 telemecanique thermal overload relay KTA3-25-25A
GV3-ME63

Abstract: GV3-ME40 telemecanique magnetic contactor telemecanique soft start motor control diagram telemecanique limit switch telemecanique overload relay telemecanique kta3-25 telemecanique gv2 11KW motor telemecanique GV2-M22
Text: relay M Contactor Overload Fig. 1b Stop Start K RSHP R RSHR M 3~ 1 L1 RSHP , : AC-53b: 4-5: 175 30/25/20 500mA 1 RSHR Conductor Data General Specifications Line conductors: L1, L2, L3/T1, T2, T3 according to IEC 60947 maximum size solid finely stranded with end , size UL/CSA rated data Terminal screws Tightening torque Stripping length Thermal , 4Hz) LED, red (blinking at 1.3Hz) Acc. to DIN 44081 and DIN 44082-1 Form 1 Normally open (21,22


Original
PDF AC-53b GV3-ME63 GV3-ME40 telemecanique magnetic contactor telemecanique soft start motor control diagram telemecanique limit switch telemecanique overload relay telemecanique kta3-25 telemecanique gv2 11KW motor telemecanique GV2-M22
LR2-D13 Telemecanique

Abstract: ca2-Dn22 Telemecanique telemecanique LR2-D13 telemecanique lr2 d13 telemecanique LA1 DN22 Sprecher Schuh ca3 elevator schematic telemecanique contactor catalogue Telemecanique LC1k06 telemecanique overload relay
Text: : Door Operator Relay Auxiliary Contactor . Manufacturer: Telemecanique Manufacturer Part Number , component pictures are not to scale. Page 1 of 75 O.THOMPSON COMPANY 8400 73rd Avenue - Unit F - , .47 Auxiliary Contacts, 3 N.O., 1 Auxiliary Contacts, 1 N.O., 1 N.C , .52 Contactor , 3 Phase


Original
PDF LCA10S-5 T12-0002-10 LR2-D13 Telemecanique ca2-Dn22 Telemecanique telemecanique LR2-D13 telemecanique lr2 d13 telemecanique LA1 DN22 Sprecher Schuh ca3 elevator schematic telemecanique contactor catalogue Telemecanique LC1k06 telemecanique overload relay
telemecanique contactor catalogue

Abstract: telemecanique A203C westinghouse ac contactor telemecanique contactor catalog westinghouse contactor A203C a203c telemecanique contactor westinghouse contactor size 2 WESTINGHOUSE life line contactor telemecanique contactor A203C
Text: . Contactor : Relay: Control Input: Test Data TEST I Telemecanique (Gouid) Size 1 Contactor Catalog #A203C , microelectronic relays to switch size 1 and size 2 contactors and incandescent lamps. Life Test Description: Both size 1 and size 2 contactor and a 25 watt incandescent lamp were selected and set up to be operated by ChipSwitch relays. The size 1 contactor , the size 2 contactor , and the incandescent lamp were each driven by , Shift: 56 Deg. Power Factor: 0.56 Contactor closes within 1 cycle Test Duration: 1 ,132,000 Cycles


OCR Scan
PDF CS6005 CS6010 telemecanique contactor catalogue telemecanique A203C westinghouse ac contactor telemecanique contactor catalog westinghouse contactor A203C a203c telemecanique contactor westinghouse contactor size 2 WESTINGHOUSE life line contactor telemecanique contactor A203C
LC1F500

Abstract: LC1-F400 LC1-F115 LC1F400 LC1DO9 LC1-F630 LC1F115 lr2d LC1D012 LC1-F330
Text: THREE PHASE MOTOR HORSEPOWER 200V(FLC) 230V(FLC) 460V(FLC) 575V(FLC) CONTACTOR C O O R D I N AT E D PROTECTION .5(1.1) .75(1.6) TYPE 2 PROTECTION .5(2.2) 1 (2.1) .5(.9) .75(1.3) 1 (1.7) 1.5(2.4) .5(2.5) .75(3.2) 2(2.7) 1.5(3.0) BUSSMANN/ TELEMECANIQUE .75(3.7) 2(3.4) 3(3.9) 1 (4.8) IEC 1 (4.2) 1.5(6.0) 1.5(6.0) 3(4.8) 5(6.1) 1.5(6.9) 2(7.8) 2(7.8) Maximum ratings are , 60 70 80 80 100 100 80 90 80 90 Form No. T2-T-IEC Page 1 of 2 BIF #8114 MOTOR


Original
PDF
sr3b261fu

Abstract: SR3B261BD SR2b201FU SCHNEIDER PLC SR3B261BD sr3b101fu SR2A201FU SR3B101BD SCHNEIDER SR3B261FU Schneider sr3b101bd schneider sr2b121bd
Text: . Welcome to the Simply Smart* world, compliments of Telemecanique . Designed for the management of simple , and 26 I/O, expandable up to 40 I/O, 3 input/output expansion modules: 6, 10 and 14 I/O, 1 Modbus , size machinery. Buildings/Services Lighting management, Access, control and surveillance , of Telemecanique products, from relays to the Nano PLC. Twido programmable controller Zelio , on the market: 4 lines of 18 characters and 1 line of icons. Power supply / Inputs 12V DC, 24V


Original
PDF DIA3ED1030801EN sr3b261fu SR3B261BD SR2b201FU SCHNEIDER PLC SR3B261BD sr3b101fu SR2A201FU SR3B101BD SCHNEIDER SR3B261FU Schneider sr3b101bd schneider sr2b121bd
telemecanique contactor catalogue

Abstract: telemecanique LC1D115 schneider contactor catalogue LC1-D150 LC1-D115 DIMENSIONS LA9-D115603 lc1d11500 CONTACTOR LC1-D115 telemecanique catalogue contactor telemecanique LC1D
Text: contactor pairs for control in category AC- 1 , 200A, pre-assembled, horizontally mounted Control circuit: a.c , Telemecanique D contactors and overload relays D115-59kw AC3 D150-80kw AC3 Telemecaniques' D , D150 incorporate all the attributes of D range which have helped to make it number 1 in contactors , conform to all international standards. Compact motor control solutions The D contactor range is now , : side mounted auxiliary contacts - no increase in overall dimensions of contactor top mounted auxiliary


OCR Scan
PDF D115-59kw D150-80kw telemecanique contactor catalogue telemecanique LC1D115 schneider contactor catalogue LC1-D150 LC1-D115 DIMENSIONS LA9-D115603 lc1d11500 CONTACTOR LC1-D115 telemecanique catalogue contactor telemecanique LC1D
GV3-ME40

Abstract: GV3-ME63 telemecanique overload relay telemecanique selector telemecanique soft start motor control diagram telemecanique push telemecanique GV3 telemecanique limit switch RSHP4025CV21 Telemecanique circuit breaker
Text: 45A: AC-53b: 4-5: 135 45A: AC-53b: 4-5: 175 30/25/20 500mA 1 RSHP Flexy General , alarm input P1, P2 Line conductors: L1, L2, L3/T1, T2, T3 according to IEC 60947 maximum size , conductors: A1, A2, 11, 21, 22, P1, P2 according to IEC 60947 maximum size UL/CSA rated data Terminal , ) LED, yellow LED, red Acc. to DIN 44081 and DIN 44082-1 Form 1 Normally open (21,22) Normally closed (11, 22) 3 A, 250 VAC 3 A, 30 VDC Above 1000m derate linearly by 1 % of unit FLC per 100m to a


Original
PDF 600VAC, AC-53b GV3-ME40 GV3-ME63 telemecanique overload relay telemecanique selector telemecanique soft start motor control diagram telemecanique push telemecanique GV3 telemecanique limit switch RSHP4025CV21 Telemecanique circuit breaker
telemecanique contactor catalogue

Abstract: Telemecanique LC1D1210 LC1D1210 GV3M63 LC1K09 Telemecanique LC1D4011 LC1D4011 LC1-D4011 lc1k0910 lc1d8011
Text: Telemecanique LH4 simple soft starting April 99 Why choose a Soft Start? Traditional , : 1 Establish full load current of the motor. 2 Select the LH4 Soft Start rated at or above the , current). Then select associated components as follows: 3 The Contactor should be selected in the , be selected on the basis of compatibility with the associated contactor range. The full load , local customer support centre for details. 1 Set the acceleration time potentiometer fully


Original
PDF
telemecanique contactor catalogue

Abstract: LC1 D12 wiring diagram LC1 K12 Schneider telemecanique contactor lc1 d65 Telemecanique LC1 D12 Telemecanique LC1 D38 LC1 D18 wiring diagram Schneider contactor catalogue ATS01N232QN LC1 D09 10 wiring diagram
Text: bypass contactor of the electronic(s) unit without dismantling the product. Characteristics: pages 1 , before switching it on again. ( 1 ) A line contactor must be used in the sequence. Compatible components , or without deceleration (freewheel), with contactor 1 /L1 Automatic control with or without , deceleration (freewheel), without contactor 5/L3 1 /L1 5/L3 3/L2 ­ F2 ­ Q1 ­ Q1 ATS , deceleration (freewheel), with contactor 1 /L1 5/L3 ­ F2 ­ F1 3/L2 1 /L1 115 V 5/L3


Original
PDF 05/2007-V2 DIA2ED2040201EN telemecanique contactor catalogue LC1 D12 wiring diagram LC1 K12 Schneider telemecanique contactor lc1 d65 Telemecanique LC1 D12 Telemecanique LC1 D38 LC1 D18 wiring diagram Schneider contactor catalogue ATS01N232QN LC1 D09 10 wiring diagram
1998 - LH4N206QN7

Abstract: LH4N106RT7 Telemecanique LH4N106QN7 LH4N212QN7 LH4N112QN7 LH4N225QN7 LH4N225LU7 LH4N230LY7 LH4N125QN7 LH4N272LY7
Text: starters. When the LH4N is combined with Telemecanique or Square D brand contactors and starters, you , speed - Seal in / fault relay for isolation contactor integration - Add on auxiliary contacts on , connections depending on the size and mode of operation. A third potentiometer, behind the sealable front , cycle - De-rate by one size if more than 360 seconds of start/stop ramp time per hour is required UL


Original
PDF 08-240V 80-415V 40-460V 2000m UL840 LH4N206QN7 LH4N106RT7 Telemecanique LH4N106QN7 LH4N212QN7 LH4N112QN7 LH4N225QN7 LH4N225LU7 LH4N230LY7 LH4N125QN7 LH4N272LY7
telemecanique contactor catalogue

Abstract: LA9-D09980 LC1-F630 LC1-F225 telemecanique lc1 fh 43 LC1F150 LC1-F330 LC1-F400 lc1f LC1F500
Text: pairs for distribution circuits, etc. Utilisation category AC- 1 Assembled by Telemecanique References c or a 4-pole changeover contactor pairs (horizontally mounted) ( 1 ) Pre-wired power , connections LC1-F780 LA9-FX970 ( 1 ) For 4-pole changeover contactor pairs, see pages 1 /64 and 1 /65 , LA9-Fi970 3-pole changeover contactor pairs ( 1 ) LA9-Fiii82 2 Reversing contactors A1 1 , connecting links. (4) For assembly of 4-pole changeover contactor pairs, see pages 1 /64 and 1 /65. (5


Original
PDF LC1-F115 LC1-F150 LC1-F185 LC1-F225 LC1-F265 LC1-F330 LA9-F103 LR9-F5i57, F5i63, F5i67, telemecanique contactor catalogue LA9-D09980 LC1-F630 LC1-F225 telemecanique lc1 fh 43 LC1F150 LC1-F330 LC1-F400 lc1f LC1F500
1998 - telemecanique LR2-D13

Abstract: LR2-D13 LR2-D13 Telemecanique VDE 0660 - 107 telemecanique lr2d13 overload contactor LR2-D13 IEC 158-1 VDE 0660 LR2D13 telemecanique thermal overload relay trip test solid state timer relays telemecanique
Text: , 4 1 , 4 1 , 5 1 , 2, 6 1 , 2, 7 3, 8 3, 8 3, 8 3, 8 11 11 Figure 1 9A, 12A, 18A, 25A, 32A contactor and size 1 overload dimensions Figure 3 40A, 50A, 65A and 80A contactor and size 3 overload , . 291-9855 Dimension information Contactor rating 9A-4kW + 1 N/O auxiliary 12A-5.5kW + 1 N/O auxiliary , size 2 overload dimensions Figure 4 9A and 12A contactor and accessories dimensions Coil suppressor , 4-6 5.5-8 7-10 9-13 12-18 17-25 23-32 28-36 30-40 37-50 48-65 55-70 63-80 80-104 95-120 110-140 size 1


Original
PDF 1970s. co237 telemecanique LR2-D13 LR2-D13 LR2-D13 Telemecanique VDE 0660 - 107 telemecanique lr2d13 overload contactor LR2-D13 IEC 158-1 VDE 0660 LR2D13 telemecanique thermal overload relay trip test solid state timer relays telemecanique
telemecanique lc1d09

Abstract: allen bradley 100-c43 telemecanique contactor LC1D80 LC1-D09 telemecanique contactor LC1D12 telemecanique contactor catalogue allen bradley 100-c30 telemecanique LC1D40 allen bradley 100-c23 LC1-D12
Text: SIZE # ELEMENT SCCR (kA) 1 1 /2 0 509-A W48 AJT15 A6D15R 100 2 0 509 , CONTACTOR OLR CLASS J SCCR (kA) 1 /2 CL00, CL01, CL02, CL03, CL04, CL25, CL45 RT*1J AJT4 100 , ) AN16ANO_C H2004B-3 A6D2- 1 /4R 100 HP 3/4 SIZE STARTER NUMBER HEATER NUMBER CLASS RK1 , ATDR12 HP CONTACTOR OLR CLASS J 100 1 /2 LC1D09 LRD07 AJT5 CLASS CC SCCR (kA , CLASS J HP CONTACTOR OLR CLASS J CLASS CC SCCR (kA) 1 /2 LC1D09 LRD06 AJT2


Original
PDF SG01V02SY500 A6D400R AJT400 A6D350R AJT300 telemecanique lc1d09 allen bradley 100-c43 telemecanique contactor LC1D80 LC1-D09 telemecanique contactor LC1D12 telemecanique contactor catalogue allen bradley 100-c30 telemecanique LC1D40 allen bradley 100-c23 LC1-D12
KTA 3-25

Abstract: ABB motor start wiring diagram telemecanique soft start motor control diagram telemecanique overload relay Telemecanique GV 2 soft start motor control diagram telemecanique magnetic contactor overload protection of induction motor soft start ac motor control diagram telemecanique limit switch
Text: across A1, A2 is 300VAC. K Fuse 1 L1 3 L2 K 5 L3 Motor protection relay Contactor , 6.3 x 0.8 mm UL, cUL compliant Yes IEC/EN 60947-4-2 Form 1 IP00 2 1 RSB Operation Diagram 1 Operation Diagram 2 Mains Ue Motor voltage 1 100% 3 2 M 3~ 35% Control input Uc 0.8 Time (s) 1 Ramp-up time 6.5s±10%. Time from zero load voltage to full load voltage , 85% voltage at the start of the ramp-up function. External Protection 1 . Recommended


Original
PDF RSB2215-B 300VAC. KTA 3-25 ABB motor start wiring diagram telemecanique soft start motor control diagram telemecanique overload relay Telemecanique GV 2 soft start motor control diagram telemecanique magnetic contactor overload protection of induction motor soft start ac motor control diagram telemecanique limit switch
1991 - telemecanique LR2-D13

Abstract: VDE 0660 iec 158-1 LR2-D13 Telemecanique Contactor JEM AC3 telemecanique IEC 158-1 IEC 158-1 VDE 0660 overload contactor LR2-D13 lr2d13 VDE 0660 BS 5424 OVERLOAD lr2-d13
Text: auxiliary 315-661 24Vdc control voltage Figure 1 9A, 12A, 18A, 25A, 32A contactor and Figure 2 25A and 32A contactor and size 2 size 1 overload dimensions overload dimensions e b e 7 b 4 9 5 92 8 c , Size of contactor to be Size of contactor to be 1 2 3 , Contactor rating under control voltage ac Figure 24V 110V 240V 415V 9A-4kW + 1 N/O auxiliary 314-551 , B12564 Figure 3 40A, 50A, 65A and 80A contactor and Figure 6 25A contactor and accessories size 3


Original
PDF B12564 24Vdc 400Hz 50/60Hz A-32A 4-48V 0-127V 10-240V 0A-80A telemecanique LR2-D13 VDE 0660 iec 158-1 LR2-D13 Telemecanique Contactor JEM AC3 telemecanique IEC 158-1 IEC 158-1 VDE 0660 overload contactor LR2-D13 lr2d13 VDE 0660 BS 5424 OVERLOAD lr2-d13
Supplyframe Tracking Pixel