The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
LT3439EFE#TRPBF Linear Technology LT3439 - Slew Rate Controlled Ultralow Noise 1A Isolated DC/DC Transformer Driver; Package: TSSOP; Pins: 16; Temperature Range: -40°C to 85°C
LT3439EFE#PBF Linear Technology LT3439 - Slew Rate Controlled Ultralow Noise 1A Isolated DC/DC Transformer Driver; Package: TSSOP; Pins: 16; Temperature Range: -40°C to 85°C
LT3439EFE Linear Technology LT3439 - Slew Rate Controlled Ultralow Noise 1A Isolated DC/DC Transformer Driver; Package: TSSOP; Pins: 16; Temperature Range: -40°C to 85°C
LT3439EFE#TR Linear Technology LT3439 - Slew Rate Controlled Ultralow Noise 1A Isolated DC/DC Transformer Driver; Package: TSSOP; Pins: 16; Temperature Range: -40°C to 85°C
LT1103CY Linear Technology IC SWITCHING CONTROLLER, Switching Regulator or Controller
LT3524S Linear Technology IC SWITCHING CONTROLLER, PDSO, Switching Regulator or Controller

tap control transformer RAYA Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
BROWN BOVERI Relay manual

Abstract: ABB NI 40 Relay manual tap control transformer RAYA ABB rxce 41 Relay manual 3 phase automatic phase changer RXCE 4 automatic phase changer file ABB NI 41 Relay settings RXTNB21 automatic 3 phase changer
Text: ni ■T>8 ASEA BROWN BOVERi Type RAYA Voltage regulating relay for tap changer control 1MDB04011â , - X-compensation •Parallel control of transformer tap-changers possible Application The RAYA voltage regulating , Type RAYA Voltage regulating relay for tap changer control MDB04011-EN ■airi IR3V08 HWOfla AB3A , Control Type RAYA 1MDB04011-EN & Protection Voltage regulating relay Page3 for tap changer control , regulating relay for tap changer control 1MDB04011-EN Page 4 Ordering Specify : • Type RAYA • Quantity


OCR Scan
PDF 1MDB04011â 162-DA 162-DAA 4U-36C RK821 021-AA 021-AB 021-AC 1MDB09004-EN BROWN BOVERI Relay manual ABB NI 40 Relay manual tap control transformer RAYA ABB rxce 41 Relay manual 3 phase automatic phase changer RXCE 4 automatic phase changer file ABB NI 41 Relay settings RXTNB21 automatic 3 phase changer
RXCE4 ASEA

Abstract: RXTNB 2 tap control transformer RAYA tap control transformer On-Load Tap changer RXCE 4 RTXP 18 ASEA RELAY resistor 560 Ohms 146-AA
Text: regulate the secondary voltage of power transformers which have on-load tap changers. Parallel control of , blocking unit in RAYA blocks the regulating pulses to the motor-operated mechanism of the tap changer when , . Independent time can be suitable when the subsequent transformer also has an on-load tap changer. When both , regulating relay can alone control the tap changer if compensation and also undervoltage and overcurrent , power transformer 's secondary rated voltage. RXTND 22 For R and X compensation and parallel control in


OCR Scan
PDF S-721 RXCE4 ASEA RXTNB 2 tap control transformer RAYA tap control transformer On-Load Tap changer RXCE 4 RTXP 18 ASEA RELAY resistor 560 Ohms 146-AA
automatic phase changer file

Abstract: 3 phase automatic phase changer automatic phase changer interposing CT automatic 3 phase changer ABB rxce 41 Relay manual SLmf tap control transformer RAYA RXCE 4 interposing relay
Text: RAYA : Separate interposing current transformer Voltage regulating relay for tap changer control , RAYA Voltage regulating relay for tap changer control 1MRK 504 006-BEN Page 1 Issued June , on-load tap changers. Parallel control of two or more transformers, each having a RAYA voltage , parallel transformers. Voltage regulating relay for tap changer control RAYA 1MRK 504 006 , Operate time setting Voltage regulating relay for tap changer control RAYA 1MRK 504 006-BEN Page


Original
PDF 006-BEN 010-BEN 1MDU04011-EN SE-721 automatic phase changer file 3 phase automatic phase changer automatic phase changer interposing CT automatic 3 phase changer ABB rxce 41 Relay manual SLmf tap control transformer RAYA RXCE 4 interposing relay
220 ac voltage regulator without transformer

Abstract: SLMF123 tap control transformer RAYA RXCE41 abb auxiliary current transformer RXIG21 RXCE 4 B03-2032E RXTNB 2 abb auxiliary current transformer SLMF 123
Text: definite-time delay • Parallel control of two or more power • Undervoltage blocking provided transformer tap , voltage required tion Application The RAYA voltage regulating relay is used to control the secondary , regulation at voltage changes of short durations. In remote controlled transformer stations RAYA with , even if a transformer is taken c of service. RAYA with fcompensating unit RXTND 22 is n< mally used , current transformer , for each power transformer , with a 0.2 A rated secondary current should be used. RAYA


OCR Scan
PDF 020-XC B03-2032E B03-9312 B03-9510E B03-9382E S-721 220 ac voltage regulator without transformer SLMF123 tap control transformer RAYA RXCE41 abb auxiliary current transformer RXIG21 RXCE 4 RXTNB 2 abb auxiliary current transformer SLMF 123
RXCE 4

Abstract: tap control transformer tap control transformer RAYA automatic phase changer file transformer winding formula step down automatic phase changer 565-1 capacitor RXIG2 RXIG2R 3 phase automatic phase changer
Text: transformer and the main load point. The device feeds to the regulating relay RXCE 4, in type RAYA , an , are each controlled simultaneously by their own regulating relay RAYA , it can happen that Trl's tap , current transformers are contained in the transformer unit RTTD 181 in the RAYA . When the transformers are , current when a power transformer is taken out of action and not to contribute to the parallel control , see , relay type RAYA for parallel control using the circulating cunent method. S = 44.45 mm, C = 7mm. 101


OCR Scan
PDF 006-AA RXCE 4 tap control transformer tap control transformer RAYA automatic phase changer file transformer winding formula step down automatic phase changer 565-1 capacitor RXIG2 RXIG2R 3 phase automatic phase changer
tap control transformer RAYA

Abstract: RXCE 4 asea over current relay rk 427 RK 427 raya
Text: 22 is used for compensation of line voltage drop between the power transformer and the main point of consumption. The compensating device supplies the regulating relay type RXCE 4 in type RAYA (see Catalogue RK , primarily consists of Mode of operation An auxiliary current transformer with primary terminals for 1 A, 2 A , current transformer (see Fig. 1) supplies type RXTND 21 with the load current in one of the phases. If the , compensation is measured in phase R The secondary current of the auxiliary current transformer gives the


OCR Scan
PDF 821-3C1 004-AA tap control transformer RAYA RXCE 4 asea over current relay rk 427 RK 427 raya
RXSF1

Abstract: protection relay type racic RXIDF 2H RXEL22 ASEA relay - RAKZB ABB RXsf1 rxsf-1 RXEG21 ASEA motor brown boveri dc motor
Text: load tap changers RAYA -5210e Resistor units RXTMA 1 -9170e Shaft current RARIC -4016e Speed monitoring , ) -2610e Differential, pilot-wire RADHL -7011e transformer harmonic restrained RADSB -5012e 3 0 , RADSG -4011e transformer RADSB -5012e Multi-input restraint, differential RADSS -6010e harmonic RADSB , differential, generator transformer bus Poly-phase relays Power supply, dc-dc ac-dc Pilot-wire differential , capacitor units RXTCD4 -9193e Tripping relay, high speed multi-contact RXMS 1 -1213e Transformer voltage


OCR Scan
PDF B03-0310E -7016e -7017e -2031e -2531e -2011e -2032e -2033e -2034e -2910e RXSF1 protection relay type racic RXIDF 2H RXEL22 ASEA relay - RAKZB ABB RXsf1 rxsf-1 RXEG21 ASEA motor brown boveri dc motor
ASEA EG 10 contactor

Abstract: asea time-lag relay RI RRCEA asea contactors tap control transformer RAYA asea EG contactor rCEA circuit diagram of three phase automatic changeover switch relay driver circuit using transistor 3604 relay
Text: secondary voltage of power transformers with on- latlng relay type RAYA of COMBIFLEX® load tap-changers , regulation. Via contactors it gives control impulses to the motor operating gear of the tap-changer. This , normally used when the subsequent transformer also has a tap-changer. When a voltage deviation arises in both a secondary and a tertiary station, the transformer of the secondary station should regulate , circuit is supplied by a built-in current transformer with primary terminals for 1, 2 and 5 A rated


OCR Scan
PDF
transformer calculation ret 521

Abstract: automatic phase changer file 0-12 1a transformer step down transformer winding ratio automatic phase changer tap transformer mva BO-02 3 phase automatic phase changer neutral and earth calculation ABB tripping curves
Text: regulation for single transformer or parallel transformers with on load tap changer · Programmable logic , are available. Voltage control for single transformer , VCTR The voltage control function can be , auxiliary equipment (binary contacts) can be connected to the voltage control function. The tap changer , transformer currents. The voltage control function for parallel transformers also includes the single transformer control module with the same functionality as described in previous point. Service values as


Original
PDF 012-BEN SE960158) 010-BEN 001-BEN 015-BEN 057-BEN S-721 transformer calculation ret 521 automatic phase changer file 0-12 1a transformer step down transformer winding ratio automatic phase changer tap transformer mva BO-02 3 phase automatic phase changer neutral and earth calculation ABB tripping curves
DY11 transformer

Abstract: selective harmonic elimination circuits overcurrent relay inverse normal curves earth BUSBAR calculation transformer calculation ret 521 48 VDC interposing relay transformer calculation mva transformer automatic phase changer tap transformer mva
Text: transformer protection and control terminal in a compact design - Settable zero sequence current , regulation for single transformer with on load tap changer 7UDQVIRUPHU SURWHFWLRQ WHUPLQDO 5(7 & , (binary contacts) can be connected to the voltage control function. The tap changer position is monitored , tap-changer) control . Function with this functionality in RET 521 terminal is VCTR for single transformer , control (On-load tap changer control ) Voltage control W8US Disturbance recorder Disturbance


Original
PDF 041-BEN SE960158) DY11 transformer selective harmonic elimination circuits overcurrent relay inverse normal curves earth BUSBAR calculation transformer calculation ret 521 48 VDC interposing relay transformer calculation mva transformer automatic phase changer tap transformer mva
three-winding power transformer

Abstract: Yy0 vector group DY11 vector group RTXP24 transformer calculation ret 521 three-winding transformer per unit 500 MVA power transformers parameters automatic phase changer E-max MOTHERBOARD MANUAL 1MRK 000 508-BB
Text: transformer protection and control terminal in a compact design · Suitable for power transformers and , winding · Voltage regulation for single transformer with on load tap changer 7UDQVIRUPHU SURWHFWLRQ , transformer , i.e. at the busbar or at the feeder ends. Constant voltage is obtained by controlling the tap , changer auxiliary equipment (binary contacts) can be connected to the voltage control function. The tap , the voltage control AutoBlock Off/On *) Rated secondary side power transformer voltage set in


Original
PDF 042-BEN SE960158) SE-721 three-winding power transformer Yy0 vector group DY11 vector group RTXP24 transformer calculation ret 521 three-winding transformer per unit 500 MVA power transformers parameters automatic phase changer E-max MOTHERBOARD MANUAL 1MRK 000 508-BB
500 MVA power transformers parameters

Abstract: 1MRK000 multiple Transformer oil monitoring with automatic circuit breaking operation automatic 3 phase changer three-winding power transformer transformer calculation ret 521 RTXP 24 automatic phase changer file 500 MVA power transformers automatic phase changer
Text: regulation for single transformer or parallel transformers with on load tap changer Programmable logic with , The numerical transformer terminal RET 521 is designed for fast and selective protection and control , control . The RET 521 includes setting adaptation to power transformer rating and instrument transformer , time-to-trip can be displayed. Voltage control for single transformer , VCTR The voltage control function can be , transformer , i.e. at the busbar or at the feeder ends. Constant voltage is obtained by controlling the tap


OCR Scan
PDF 1MRK504 001-BEN SE960158) 010-BEN 015-BEN 1MRK511 057-BEN 500 MVA power transformers parameters 1MRK000 multiple Transformer oil monitoring with automatic circuit breaking operation automatic 3 phase changer three-winding power transformer transformer calculation ret 521 RTXP 24 automatic phase changer file 500 MVA power transformers automatic phase changer
overcurrent relay inverse normal curves

Abstract: neutral earth BUSBAR calculation transformer calculation ret 521 Yy0 vector group 48 VDC interposing relay DY11 vector group RL110 tap control transformer mva transformer ANSI overcurrent relay inverse normal curves
Text: overvoltage protection UPW!) Single transformer voltage control (On-load tap changer control ) Voltage , transformer protection and control terminal in a compact design - Settable zero sequence current , regulation for single transformer with on load tap changer · Configurable logic with inputs and outputs , VLQJOH WUDQVIRUPHU 9&75 The single transformer voltage control function included in RET 521-C1 is , auxiliary equipment (binary contacts) can be connected to the voltage control function. The tap changer


Original
PDF 040-BEN SE960158) SE-721 overcurrent relay inverse normal curves neutral earth BUSBAR calculation transformer calculation ret 521 Yy0 vector group 48 VDC interposing relay DY11 vector group RL110 tap control transformer mva transformer ANSI overcurrent relay inverse normal curves
48 VDC interposing relay

Abstract: el 504 TRANSFORMER CT 1A transformer calculation ret 521 optocoupler fiber 3 phase changer DY11 vector group
Text: characteristic and connected to the LV winding · Voltage regulation for single transformer with on load tap , ) can be connected to the voltage control function. The tap changer position is monitored by a 420 , control (On-load tap changer control ) Voltage control W8US Disturbance recorder Disturbance , Data subject to change without notice (SE960158) )HDWXUHV · Pre-configured transformer , transformer protection terminal in a compact design · Suitable for power transformers and


Original
PDF 019-BEN SE960158) 010-BEN 001-BEN 015-BEN SE-721 48 VDC interposing relay el 504 TRANSFORMER CT 1A transformer calculation ret 521 optocoupler fiber 3 phase changer DY11 vector group
three-winding power transformer

Abstract: RTXP24 40 MVA transformer transformer calculation ret 521 Yy0 vector group 2.5 mva transformer calculation of transformer differential relay DY11 vector group interposing CT E-max MOTHERBOARD MANUAL
Text: ! Overexcitation protection Overexcitation protection PW@Y Single transformer voltage control (On-load tap , characteristic and connected to the MV winding · Voltage regulation for single transformer with on load tap , transformer , i.e. at the busbar or at the feeder ends. Constant voltage is obtained by controlling the tap , (binary contacts) can be connected to the voltage control function. The tap changer position is , : A Data subject to change without notice (SE960158) )HDWXUHV · Pre-configured transformer


Original
PDF 020-BEN SE960158) 010-BEN 001-BEN 015-BEN SE-721 three-winding power transformer RTXP24 40 MVA transformer transformer calculation ret 521 Yy0 vector group 2.5 mva transformer calculation of transformer differential relay DY11 vector group interposing CT E-max MOTHERBOARD MANUAL
interposing CT

Abstract: transformer calculation ret 521 neutral earth BUSBAR calculation 48 VDC interposing relay 015-UEN three-winding transformer 608-CA 2.2 MVA generator DY11 vector group 100 MVA transformer
Text: delayed overvoltage protection UPW!) Single transformer voltage control (On-load tap changer control , regulation for single transformer with on load tap changer · Additional programmable logic with inputs and , included. The single transformer voltage control function included in RET 521-C1 is used to maintain a , voltage control function. The tap changer position is monitored by a 4-20 mA-input to the voltage , the voltage control AutoBlock Off/On *) Rated secondary side power transformer voltage set in


Original
PDF 018-BEN SE960158) 010-BEN 001-BEN 015-BEN SE-721 interposing CT transformer calculation ret 521 neutral earth BUSBAR calculation 48 VDC interposing relay 015-UEN three-winding transformer 608-CA 2.2 MVA generator DY11 vector group 100 MVA transformer
full ready report on automatic phase changer

Abstract: RTXP24 1MRK 003 530 OPTOCOUPLER tl 521 overcurrent relay inverse normal curves ANSI 87T 1acwd transformer calculation ret 521 40 MVA transformer On-Load Tap changer
Text: undervoltage protection UVW! Voltage control for single transformer (On-load tap changer control ) Voltage , voltage for selectable transformer sides. Two protection module are available. - Tap changer position , characteristics · Voltage regulation for single transformer with on load tap changer is included 3URWHFW,7 , transformer or to an open 9ROWDJH FRQWURO IRU VLQJOH WUDQVIRUPHU 9&75 The voltage control function can , voltage control function. The tap changer position is monitored by a 4-20 mA-input to the voltage control


Original
PDF 047-BEN SE-721 full ready report on automatic phase changer RTXP24 1MRK 003 530 OPTOCOUPLER tl 521 overcurrent relay inverse normal curves ANSI 87T 1acwd transformer calculation ret 521 40 MVA transformer On-Load Tap changer
erj8enf1001

Abstract: Design -5V dc power supply using center-tapped transformer input and output center tap transformer H143-ND1 mfr-25fbf distribution transformer specification ECS-T1CY475R SPT7866 74VLT244 ECU-V1H103KBM
Text: center tap of the RF transformer is driven by the VCM output pin of the SPT7864/66 which is typically , center tap of the RF transformer at the RF-IN connection. Note that series damping resistors (value , V. The transformer 's secondary center tap pin may also be driven SPT AN7864/66 3 10/8/01 , clock transformer center tap . Not installed: allows the clock signals to be biased by the ADC , V of common-mode voltage, internally provided. The board supports straight AC transformer coupling


Original
PDF AN7864/66 10-bit SPT7864, SPT7864/66 1902EK-ND1 H143-ND1 EB7864/66/68 erj8enf1001 Design -5V dc power supply using center-tapped transformer input and output center tap transformer H143-ND1 mfr-25fbf distribution transformer specification ECS-T1CY475R SPT7866 74VLT244 ECU-V1H103KBM
2002 - AN786

Abstract: erj8enf1001 Amphenol Assembly instructions ECU-V1H102KBM ECU-V1H103KBM SPT7864 SPT7866 center tap transformer for rf signal 74VLT244
Text: . The transformer circuit consists of a Mini-Circuit T1-6T RF transformer (1:1, with center tap , accommodate the user's drive circuit. DIGITAL OUTPUT The center tap of the RF transformer is driven by , of driving 50 µA, typically. It is used to drive the center tap of the RF transformer at the RF-IN , normally provided by the ADC and is typically 1.5 V. The transformer 's secondary center tap pin may also , single-to-differential amplifier and transformer secondary center tap . Removed: disconnects the VCM pin from input


Original
PDF AN7864/66 10-bit SPT7864, SPT7864/66 AN786 erj8enf1001 Amphenol Assembly instructions ECU-V1H102KBM ECU-V1H103KBM SPT7864 SPT7866 center tap transformer for rf signal 74VLT244
center tap transformer for rf signal

Abstract: input and output center tap transformer 7868 74VLT244 tap control transformer SPT7868 SPT7866 SPT7864 ECU-V1H103KBM transformer centre tap
Text: Mini-Circuit T1-6T RF transformer (1:1, with center tap ), center-tapped secondary with a 1 dB pass-band from , OUTPUT The center tap of the RF transformer is driven by the VCM output pin of the SPT7864/66/68 , capable of driving 50 µA, typically. It is used to drive the center tap of the RF transformer at the , into the single-to-differential amplifier and transformer secondary center tap . Removed: disconnects , to connector P1. Installed: allows a fixed voltage to be applied to the clock transformer center tap


Original
PDF AN7864/66/68 10-bit SPT7864, SPT7864/66/68 1902EK-ND1 H143-ND1 EB7864/66/68 center tap transformer for rf signal input and output center tap transformer 7868 74VLT244 tap control transformer SPT7868 SPT7866 SPT7864 ECU-V1H103KBM transformer centre tap
2007 - Westinghouse Sudden Pressure Relay

Abstract: 115KV transformer westinghouse transformer inrush
Text: , when a high voltage fused transformer is placed as a tap on a transmission line, coordination is not , of turns used on the input transformer , so that, for instance, 4.6A on input 1 (at a tap of 4.6 , minimum operate 8 auto tap changer (if there is one); transformer steady state excitation , Transformer Protection Application Guide About the Author George Rockefeller is President of , editorial corrections Transformer Protection Application Guide This guide focuses primarily on


Original
PDF BE1-51 Westinghouse Sudden Pressure Relay 115KV transformer westinghouse transformer inrush
2011 - Not Available

Abstract: No abstract text available
Text: Supply +12 Vdc (100-240 VAC AC/DC transformer included) Manual Control Momentary Lever Actuator Switch w/ 7-Segment LED Display ( tap to step, hold to jog) Remote Control RS-232 (9600, 19200, or , processing time) DC Supply +12 Vdc (100-240 VAC AC/DC transformer included) Manual Control Momentary Lever Actuator Switch w/ 7-Segment LED Display ( tap to step, hold to jog) Remote Control , Supply +12 Vdc (100-240 VAC AC/DC transformer included) Manual Control Two Momentary Lever


Original
PDF 50BA-001-63 50BA-002-95 -RS-232
2012 - 3.5 mva transformer

Abstract: Westinghouse Sudden Pressure Relay induction furnace circuit diagram current transformer ABB
Text: components – insulation materials and kits, tap changers, bushings, and electronic control equipment â , efficiently and reliably. They also help maintain power quality and control , and facilitate electrical networks. ABB is a global leader in transformer technologies that enable utility and industry customers , dry-type transformer products The quiet life ABB’s ultralow-noise power transformers 33 Power , reactors for network stability control 45 Trends in transformation A world in transformation ABB


Original
PDF
transformer calculation ret 521

Abstract: 1MRK000284-AB overcurrent relay inverse normal curves transformer 2 mva three-winding transformer Transformer Control, Multi Tap 500 VA inrush reactor 20 kV DY11 vector group RTXP24 shunt reactor
Text: to 8 parallel transformers with on load tap changer, hot stand-by transformer control is included · , The numerical transformer terminal RET 521 is designed for fast and selective protection and control , from the tap changer auxiliary equipment (binary contacts) can be connected to the voltage control , includes the single transformer control module with the same functionality as described in previous point , Revision: A Data subject to change without notice )HDWXUHV · Multiple function transformer


Original
PDF 035-BEN SE-721 transformer calculation ret 521 1MRK000284-AB overcurrent relay inverse normal curves transformer 2 mva three-winding transformer Transformer Control, Multi Tap 500 VA inrush reactor 20 kV DY11 vector group RTXP24 shunt reactor
2013 - Actus relays

Abstract: Mors Smitt
Text: MS2V164-S Voltage regulating & tap change control 42 MS1M122 Transformer parallel control system , regulation MS2V164-S Voltage regulation & TAP change control The MS2V164-S continuously monitors the transformer output voltage & current & provides RAISE & LOWER control commands to the on-load tap changer , control for power transmission and distribution Auxiliary . Tripping . Supervision . Pilot wire Mors , the highest standards. High performance protection and control The Actus relays are a new


Original
PDF
Supplyframe Tracking Pixel