The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
LT3439EFE#TRPBF Linear Technology LT3439 - Slew Rate Controlled Ultralow Noise 1A Isolated DC/DC Transformer Driver; Package: TSSOP; Pins: 16; Temperature Range: -40°C to 85°C
LT3439EFE#PBF Linear Technology LT3439 - Slew Rate Controlled Ultralow Noise 1A Isolated DC/DC Transformer Driver; Package: TSSOP; Pins: 16; Temperature Range: -40°C to 85°C
LT3439EFE Linear Technology LT3439 - Slew Rate Controlled Ultralow Noise 1A Isolated DC/DC Transformer Driver; Package: TSSOP; Pins: 16; Temperature Range: -40°C to 85°C
LT3439EFE#TR Linear Technology LT3439 - Slew Rate Controlled Ultralow Noise 1A Isolated DC/DC Transformer Driver; Package: TSSOP; Pins: 16; Temperature Range: -40°C to 85°C
LTC1698ES#TR Linear Technology LTC1698 - Isolated Secondary Synchronous Rectifier Controller; Package: SO; Pins: 16; Temperature Range: -40°C to 85°C
LTC3900IS8#PBF Linear Technology LTC3900 - Synchronous Rectifier Driver for Forward Converters; Package: SO; Pins: 8; Temperature Range: -40°C to 85°C

stancor rectifier transformer Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
RT-206

Abstract: Stancor RT-202 stancor rectifier transformer Stancor RT-206 Stancor RT-204 RT-2012 Stancor Transformer
Text: SIANCOR Power Transformers RECTIFIER TRANSFORMERS (RECTIFIERS NOT INCLUDED) UNIVERSAL RECTIFIER TRANSFORMERS: s E C T STANCOR Part No. Style NV RT-201 primaries 117 volts Output Resistive Range of Applied A.C. or Inductive Load Max. D.C. Rectifier Volts Under Amps. Circuit Load , , 11-25000 RECTIFIER TRANSFORMERS Each transformer has the winding arrangement and terminal num­ bering , RECTIFIER TRANSFORMERS APPLICATION DATA RT-206 STANCOR Power Supply Input 117 VAC Connect Term


OCR Scan
PDF RT-201 RT-408 RT-206 Stancor RT-202 stancor rectifier transformer Stancor RT-206 Stancor RT-204 RT-2012 Stancor Transformer
transformer winding formula

Abstract: Stancor RT-202 Stancor RT-206 bridge rectifier 206 stancor rectifier transformer Stancor rt-204 50 50 mfd ELECTROLYTIC CAPACITOR RT-204 stancor transformer RT-202 RT-206
Text: = 7500 MFD, 8 = 12000 MFD, 9 = 15000 MFD Rectifier Transformers Each transformer has the , information is given so that the proper transformer may be selected. The rectifier circuits as related to , included All Primaries 117 Volts 50/60 Hz - Solder Lug Termination Sec. STANCOR PART NUMBER Style Rectifier Circuit Range of Output Resistive AppliedA.C. or , transformer consists of two identical windings connected to terminals 8 & 9 and to 10 & 11 respectively. Use


Original
PDF
RT-2012 Stancor Transformer

Abstract: stancor rectifier transformer
Text: ) which the transformer has to deliver and the D.C. output current taken from the rectifier (IDC) is: IAC , All Primaries 117 Volts 50/60 Hz - Solder Lug Termination STANCOR PART Sec. NUMBER Style Rectifier Circuit Range of Output Resistive Applied A.C. or Inductive Load Volts Under Max. D.C , Data refer to pages 8-10. For outline drawings refer to page 12. Rectifier Transformers Each transformer has the winding arrangement and terminal numbering shown in the schematic diagrams. The primary


Original
PDF RT-201 RT-202 RT-2012 Stancor Transformer stancor rectifier transformer
1999 - Stancor RT-202

Abstract: Stancor RT-206 RT-2012 Stancor Transformer stancor rectifier transformer stancor transformer RT-202 RT-408 Stancor rt-204 RT-204 EMERSON rectifier RT-402
Text: 59-61. For outline drawings refer to page 62. Rectifier Transformers Each transformer has the , P O W E R T R A N S F O R M E R S Rectifier Transformers Style NV with lugs ­­Rectifiers not included All Primaries 117 Volts 50/60 Hz - Solder Lug Termination STANCOR PART Sec. NUMBER A RT-201 RT-202 B RT-204 RT-206 C RT-208 RT-2012 D RT-402 RT-408 Style NV NV NV NV NV NV NV NV Rectifier , operation; however, may be satisfactorily operated at 400 cycles. The secondary winding of each transformer


Original
PDF RT-201 RT-202 RT-204 RT-206 RT-208 RT-2012 RT-402 RT-408 Stancor RT-202 Stancor RT-206 RT-2012 Stancor Transformer stancor rectifier transformer stancor transformer RT-202 RT-408 Stancor rt-204 EMERSON rectifier
stancor rectifier transformer

Abstract: Stancor diode sy o canada
Text: requirements of specified country Junction of Paths Rectifier Restriction of Hazardous Substances Resistor, Fixed, General Stancor is committed to have RoHS compliance on Stancor parts by July 1, 2006. Please contact Stancor customer service at 1-866-323-7310 for RoHS compliant part availability. Switch, Single Throw General Terminal, Circuit Transformer , Magnetic Core Nonsaturating OR www.stancor.com Stancor


Original
PDF
1999 - P-8637

Abstract: Stancor power transformer EMERSON rectifier stancor rectifier transformer transformer 230
Text: Transformers Isolation Transformer ­­ See Accessories, pages 103-104, for International Adapter Plugs STANCOR PART Sec. NUMBER A P-6287 P-8620 GSD-75 P-8630 GSD-100 B P-8631 GSD-150 P-8632 GSD-250 GSD-300 C , plug. See Accessories section for STANCOR 's high quality line of International Adapter Plugs. W H Y & W H E R E A U T O & I S O L AT I O N TRANSFORMERS ARE USED Stancor 's stock Auto Transformers are , connection between them is permissible, the Auto Transformer offers the advantages of smaller size, less


Original
PDF P-6287 P-8620 GSD-75 P-8630 GSD-100 P-8631 GSD-150 P-8632 GSD-250 GSD-300 P-8637 Stancor power transformer EMERSON rectifier stancor rectifier transformer transformer 230
stancor rectifier transformer

Abstract: Stancor power transformer Stancor output transformer stancor transformer Stancor step down transformer synchronous MOTORS
Text: used in most countries by using an input adapter plug. See page 40 for STANCOR 's high quality line of International Adapter Plugs. W h y & W here A uto & I solation T ransformers are used Stancor 's stock Auto , direct connection between them is permissible, the Auto Transformer offers the advantages of smaller , by the manufacturer and should be observed. It is much better to buy a transformer with a larger VA , various combinations of rectifier circuits and types of load following the rectifier . These items are


Original
PDF
step down transformer 606

Abstract: step down transformer 6-0-6 stancor rectifier transformer stancor transformer GSD-350 p8689 Stancor Stancor power transformer P-8622 GSD-100
Text: Plugs · Designed for 50/60 Hertz STANCOR RMS PART Voltage Input Output Test , . See page 40 for STANCOR 's high quality line of International Adapter Plugs. W h y & W here A uto & I solation T ransformers are used Stancor 's stock Auto Transformers are connected for either step-down or , permissible, the Auto Transformer offers the advantages of smaller size, less weight, and lower cost. This , better to buy a transformer with a larger VA rating than you will actually need because of larger motor


Original
PDF
4812b

Abstract: Stancor RT-202 Stancor RT-204 Stancor RT-206 stancor rectifier transformer 120-114751 transformers RT-204 70-111226-5 70-111224-5
Text: . This is also required for a full-wave center tapped rectifier circuit. · he typical transformer , Rectifier Resistor, Fixed, General Switch, Single Throw General Terminal, Circuit Transformer , Magnetic , PA R T N U M B E R I N D E X Par t Number/Pa ge Number Index STANCOR Part No. Section Pg. Sec. STANCOR Part No. Section Pg. Sec. STANCOR Part No. Section Pg. Sec , . www.stancor.com PA R T N U M B E R I N D E X Par t N u m b e r / Pa g e N u m b e r I n d ex STANCOR


Original
PDF 129AR-902 C-2691 DSW-210 DSW-212 DSW-220 4812b Stancor RT-202 Stancor RT-204 Stancor RT-206 stancor rectifier transformer 120-114751 transformers RT-204 70-111226-5 70-111224-5
Not Available

Abstract: No abstract text available
Text: €¢ Designed for 50/60 Hertz STANCOR PART Sec. NUMBER A Type Voltage Step Input Voltage , Transformer offers the advantages of smaller size, less weight, and lower cost. This type of unit is , transformer with a larger VA rating than you will actually need because of larger motor starting currents and , observed for various combinations of rectifier circuits and types of load following the rectifier . These , Stancor


Original
PDF
Stancor tp4

Abstract: Stancor tp-2 Stancor tp-3 P-8362
Text: 500MF 8.0V. D.C. at 4.0 Amps. D.C. 3000M F STANCOR Secondary No. 1 Part No. FWB Rectifier , SIANCOR Power Transformers CONTROL TRANSFORMERS CONTROL FILAMENT POWER TRANSFORMERS Stancor , , control, energy limiting, filament, isolation, plate and filament, and rectifier . In addition, there are , b 27? 27? 2 '7 . b 2'7. t, 37 b 37.6 STANCOR Part No. P-8628 P-8629 P-4026 P , €™d.) s E C T A B r n E c G H 1 K L STANCOR Pari No. P


OCR Scan
PDF P-8361 P-8362 P-8363 P-8364 Stancor tp4 Stancor tp-2 Stancor tp-3 P-8362
transformer AC 220 dc 12

Abstract: Class 130(B) transformer centre tapped Transformer center tap transformer 4812b 220 110 transformer transformer centre tap Stancor p-6378 power transformer Stancor output transformer
Text: ( transformer type) C.T. STANCOR Part No. Pg. Sec. Printed Circuit Transformers , Input Voltage (AC) Output AC/DC Catalog Section ( transformer type) C.T. STANCOR Part , ) STAF-2100F 36 A 70 Output AC/DC Catalog Section ( transformer type) STANCOR Part , 6.30 Catalog Section ( transformer type) STANCOR Part No. Pg. Sec. Printed , www.stancor.com * STANCOR Part No. * * * * * Q UI C K S E L E C T I O N GUI D E Transformer and


Original
PDF D-350 P-8634 GSD-500 GIS-500 GISD-500 GSD-750 GIS-1000 GSD-1000 GISD-1000 GSD-1500 transformer AC 220 dc 12 Class 130(B) transformer centre tapped Transformer center tap transformer 4812b 220 110 transformer transformer centre tap Stancor p-6378 power transformer Stancor output transformer
TGC25-28

Abstract: No abstract text available
Text: TransGlobal® TGC Series International Transformer Chassis Mount SPECIFICATIONS: ! WARNING , : DIELECTRIC STRENGTH: AGENCY APPROVALS: FIRE HAZARD Do not exceed transformer ratings. Higher voltage , simultaneous use of all windings. STANCOR PART NUMBER Agency Certif. STANCOR PART NUMBER VA , Rating Series Parallel Volts Amps Volts Amps 2. The input to the transformer must be fused with , PARALLEL: X.XV X.XA 7 CHINA 2 1 PA41-XX-XX Label “A” Detail Stancor


Original
PDF EN61558 EN60950 E173993 115/230V 50/60Hz PA41-XX-XX TGC25-28
6608A

Abstract: 37-6608A E173993 TGC175-28 TGC25-10 TGC80-16 TGC80-24 stancor transformer Stancor tgc80-24 TGC25-12
Text: TransGlobal® TGC Series International Transformer Chassis Mount SPECIFICATIONS: ! WARNING , : DIELECTRIC STRENGTH: AGENCY APPROVALS: FIRE HAZARD Do not exceed transformer ratings. Higher voltage , simultaneous use of all windings. STANCOR PART NUMBER Agency Certif. STANCOR PART NUMBER VA , transformer must be fused with an IEC 60127-2 Standard Sheet 3 Time lag (surge-proof) Low-breaking capacity , Stancor


Original
PDF EN61558 EN60950 E173993 115/230V 50/60Hz PA41-XX-XX 6608A 37-6608A E173993 TGC175-28 TGC25-10 TGC80-16 TGC80-24 stancor transformer Stancor tgc80-24 TGC25-12
E173993

Abstract: TG20-10 TG05-24 6607A TG05-36 TG20-24 TG05-10 TG10-28 TG05-20 TG56-24
Text: TransGlobal® TG Series International Transformer Printed Circuit Mount SPECIFICATIONS: ! , . Failure to do so could result in death or serious injury. FIRE HAZARD Do not exceed transformer ratings , requires simultaneous use of all windings. STANCOR PART NUMBER VA TG2H-10 2.5 TG05 , 5.0 @ 2.00 2. The input to the transformer must be fused with an IEC 60127-2 Standard Sheet 3 Time , . STANCOR PART NUMBER VA TG2H-24 2.5 24.0 C.T. @ 0.10 12.0 @ 0.20


Original
PDF EN61558 EN60950 E173993 115/230V 50/60Hz P14A-XX-XX E173993 TG20-10 TG05-24 6607A TG05-36 TG20-24 TG05-10 TG10-28 TG05-20 TG56-24
P-8560

Abstract: Stancor stancor transformer
Text: could result in death or serious injury. FIRE HAZARD Do not exceed transformer ratings. Higher , 2 1 1 PRI 115V 50/60 Hz STANCOR H MAX. P-XXXX 2 .188 x .312 (4 PLACES , SECONDARY 20V CT 5 2 SCHEMATIC DIAGRAM STANCOR Part No. Pri. Volts Mtg. Style Sec , www.stancor.com 0730 Stancor


Original
PDF P-8559, P-8560, P-8604 50/60Hz P-8559 P-8560 E68100 7-6873A P-8560 Stancor stancor transformer
Not Available

Abstract: No abstract text available
Text: . 5 Transformer Product Application Section , . Inside Front Cover Directory of Stancor Distributors NAME, ADDRESS AND PHONE NUMBER OF NEAREST STANCOR DISTRIBUTORS NAME ADDRESS PHONE Warranty Statement All statements, technical , ©COPYRIGHT 1992 WHITE-RODGERS LOGANSPORT DIVISION, EMERSON ELECTRIC CO. STANCOR PRODUCTS . 131 GODFREY ST. .


OCR Scan
PDF
8653 p

Abstract: Stancor p 8652 37-6871A P-8656 P-8653 Stancor power transformer Stancor P-8652 P-8655 stancor transformer
Text: POWER TRANSFORMERS P-5016, P-8380, P-8652, P-8653, P-8655, P-8656 SPECIFICATIONS: ! WARNING ELECTROCUTION HAZARD Disconnect electric power to system at main fuse or circuit breaker box before servicing. Failure to do so could result in death or serious injury. FIRE HAZARD Do not exceed transformer ratings , PLACES) STANCOR Part No. Sec. Volts P-8652 P-8653 P-8380 P-5016 P-8655 P-8656 10V CT , 4.10 PART NO. 37-6871B Replaces 37-6871A 0741 Stancor


Original
PDF P-5016, P-8380, P-8652, P-8653, P-8655, P-8656 50/60Hz 37-6871B 7-6871A 8653 p Stancor p 8652 37-6871A P-8656 P-8653 Stancor power transformer Stancor P-8652 P-8655 stancor transformer
Not Available

Abstract: No abstract text available
Text: in death or serious injury. DIELECTRIC STRENGTH: FIRE HAZARD Do not exceed transformer ratings , ) STANCOR Part No. P-6287 GSD-75 P-8630 GSD-100 P-8631 GSD-150 P-8632 GSD-250 GSD-300 GSD-350 P , 17.0 20.0 PART NO. 37-6200C www.stancor.com Replaces 37-6200B 0837 Stancor


Original
PDF 230VAC, 50/60Hz 5-15R 37-6200C 37-6200B
P-8574

Abstract: TRANSFORMER CT 2A Stancor E68100 led 230v circuit diagram UL506
Text: FILAMENT TRANSFORMER P-8574 SPECIFICATIONS: ! WARNING INPUT: 115 / 230V, 50/60Hz OUTPUT: 25.2 V CT @ 2A INSULATION RATING: Class A (105°C) TEMPERATURE RISE: 65°C Rise above 40°C ambient DIELECTRIC STRENGTH: 1500V RMS AGENCY: UL Recognized for use in the US and Canada per UL506 FILE NUMBER , transformer ratings. Higher voltage may damage control and could cause personal injury or property damage , PART NO. 37-6891B Replaces 37-6891A 0741 Stancor


Original
PDF P-8574 50/60Hz UL506 E68100 37-6891B 7-6891A P-8574 TRANSFORMER CT 2A Stancor E68100 led 230v circuit diagram UL506
Not Available

Abstract: No abstract text available
Text: CONDUCTOR OF NEMA STANDARD CORD AND RECEPTACLE FOR SAFETYf s E C T STANCOR Part No. P-6287 P , manufacturer and should be observed. It is much better to buy a transformer with a larger V.A. rating than , elsewhere in this catalog should be observed for various combinations of rectifier circuits and types of load following the rectifier . These items are made with our standard N.E.M.A. plugs and receptacles


OCR Scan
PDF P-6287 P-8620t GSD-75 P-8630 GSD-100 P-8631 GSD-150 P-8632 GSD-250 GSD-300
Stancor PM8420

Abstract: No abstract text available
Text: S NO IA C R Power Transformers PLATE AND FILAMENT TYPE Stancor 's line of commercial grade power transformers offer a choice of standard mounting styles. Listings are in ascending order of , Circuits. STANCOR Part No. PM-8420 P-8356 PC-8406 PC-8410 PC-8412 Style M c t C C C , P-6426 W f For use in Half-Wave Circuits 380t 117 volts Rectifier Fila. Volts , STANCOR Part No. PS-8415 PS-8416 PA-8421 Plate Winding A.C. Volts | OCMA 117 •® co 1


OCR Scan
PDF P-6425. Stancor PM8420
LB-1240

Abstract: Stancor LB-6230
Text: transformer ratings. Higher voltage may damage control and could cause personal injury or property damage , €“ Reduces radiated magnetic fields and results in balanced windings. V.A. STANCOR or Part No. Watts , of the coils must be connected in reverse in order to get correct polarity and voltage. Stancor


Original
PDF 115/230VAC, 50/60Hz LB-1240 Stancor LB-6230
Stancor RT-206

Abstract: Stancor RT-204 Stancor RT-202 RT-204 RT-402 RT-208 RT-408 RT204 RT-201 Stancor
Text: 3-5 - 4-6 4-5 4-5 10 6 11 7 9 4 5 loAd 4 5 STANCOR PART , pages 9 & 10. www.stancor.com 5 6 7 10 11 POWER TRANSFORMERS Rectifier Transformers , loAd 4 5 STANCOR PART NUMBER 3 9 3 Sec. Full Wave Bridge , 10 6 11 7 9 4 5 loAd 4 5 STANCOR PART NUMBER 3 9 3 , 29.5 28.0 26.0 25.0 Stancor


Original
PDF RT-201 RT-202 RT-204 Stancor RT-206 Stancor RT-204 Stancor RT-202 RT-204 RT-402 RT-208 RT-408 RT204 RT-201 Stancor
SW-520

Abstract: 12V .4A Transformer DSW-336 SW-420 transformer 32V CT 1,5A DSW-316 transformer 120V 12V 8A TRANSFORMER CT 1A 12v DSW-224 E33334
Text: transformer ratings. Higher voltage may damage control and could cause personal injury or property damage , / DSW Series Split Bobbin-Printed Circuit Transformers STANCOR Part No. Secondary RMS Rating , .1A 60V @ .2A 60V @ .32A Stancor


Original
PDF 115VAC, 50/60Hz 115/230VAC, UL-506 to20V SW-520 12V .4A Transformer DSW-336 SW-420 transformer 32V CT 1,5A DSW-316 transformer 120V 12V 8A TRANSFORMER CT 1A 12v DSW-224 E33334
Supplyframe Tracking Pixel