1995 - sonar beamforming

Abstract: passive sonar block diagram RTI-817 74AS SERIES sonar block diagram beamforming in sonar lt 8224 2 pole 6 way rotary switch radar sensor specification 74ALS SERIES
Text: Sonar Beamforming 15.1 15 OVERVIEW This chapter describes a real-time digital beamforming system for passive sonar . The design of this system is based on several ADSP-2100s that , FREQUENCY TIME BEARING Figure 15.1 Generic Passive Sonar System 15.2 SONAR BEAMFORMING In its simplest form, sonar beamforming can be defined as "the process of combining the outputs from a number of , components and techniques; this chapter focuses on a digital beamforming technique. 502 Sonar


Original
PDF ADSP-2100s ADSP-2100 OE-10, sonar beamforming passive sonar block diagram RTI-817 74AS SERIES sonar block diagram beamforming in sonar lt 8224 2 pole 6 way rotary switch radar sensor specification 74ALS SERIES
1990 - sonar beamforming

Abstract: motorola 68000 architecture assembly language programs for fft algorithm hall 503 911 Adele ADSP filter algorithm implementation sonar ranging example circuits basics DTMF encoder Motorola 581 motorola 68000 microprocessor
Text: .484 CHAPTER 15 477 478 SONAR BEAMFORMING 15.1 15.2 OVERVIEW . SONAR BEAMFORMING .502 15.2.1Time-Delay Beamforming .503 15.2.2Digital Beamforming , multifrequency coding (DTMF) How to generate and detect the CCITT standard DTMF signals. · Sonar beamforming Both software and hardware for a digital beamforming system for passive sonar . · Memory interface A


Original
PDF ADSP-2100 sonar beamforming motorola 68000 architecture assembly language programs for fft algorithm hall 503 911 Adele ADSP filter algorithm implementation sonar ranging example circuits basics DTMF encoder Motorola 581 motorola 68000 microprocessor
sonar beamforming

Abstract: IMSA113 IMS A121
Text: – ENHANCMENT OF A100/A110/A121 APPLICATIONS ■GHOST7ECHO CANCELLATION ■RADAR/ SONAR BEAMFORMING ■DIGITAL


OCR Scan
PDF IMSA113 20MHz A100/A110/A121 IMSA113is 00fci727e! sonar beamforming IMS A121
sonar beamforming

Abstract: No abstract text available
Text: cancellation Radar/ Sonar Beamforming Digital TV line buffer Latency equaliser DESCRIPTION The IMS A113 is a


OCR Scan
PDF 250mWatts PLCC44 A100/A110/A121 A113-J20S sonar beamforming
Not Available

Abstract: No abstract text available
Text: /A121 applications Ghost/echo cancellation Radar/ Sonar Beamforming Digital TV line buffer Latency


OCR Scan
PDF A113-J20S
ultrasound transducer circuit driver

Abstract: sonar block diagram ultrasound transducer transformer sonar transformer transducer MD2131 ultrasonic transducer driver circuits ultrasonic piezoelectric transducer driver piezo transformer driver pulse transformer drive pwm ic pulse transformer driver ic
Text: used in NDT, Sonar and other ultrasound phase-array focusing beamforming applications. The IC circuit , Product Summary Sheet Applications: Medical imaging ultrasound beamforming transmitter High resolution NDT and Sonar phase array driver Ultrasonic phase array focusing transmitter Piezoelectric & , Speed Ultrasound Beamforming Source Driver +2.5V +5.0V VLL VDD C3A C2A KA C1A +5.0V , Latch & Control Logic SIN/COS A Table & Level Translator Q Vector Beamforming Switch Matrix PB


Original
PDF MD2131 DN2625 0-100V DN2625 40-Lead MD2131K7-G MD2131 ultrasound transducer circuit driver sonar block diagram ultrasound transducer transformer sonar transformer transducer ultrasonic transducer driver circuits ultrasonic piezoelectric transducer driver piezo transformer driver pulse transformer drive pwm ic pulse transformer driver ic
2003 - arm processor 7 features

Abstract: sonar beamforming arm7 architecture ARM7 instruction set for atmel ultrasound sonar AT572D740 BUTTERFLY DSP butterfly atmel computer dual core processor
Text: , Communication, and Beam-forming Applications · High-performance DSP Delivering 1.5 GOPS at 100 MHz · , -MHz Operation from 25-MHz Reference Clock · Audio Beam-forming , Professional Audio, High Comfort Audio Conference · High Quality Speech Synthesis, Voice Mail · Beam-forming for 2G and 3G Base Stations · Speech/Voice Recognition, Biometrics · Ultrasound Scanner and MRI · Radar/ Sonar /Cruise Control ·


Original
PDF AT572D740 40-bit 100-MHz 25-MHz 11-bit 16-bit 24bit 034A-ASIC-04/03/10K 352-ball arm processor 7 features sonar beamforming arm7 architecture ARM7 instruction set for atmel ultrasound sonar AT572D740 BUTTERFLY DSP butterfly atmel computer dual core processor
sonar beamforming

Abstract: airplay cordic design for fixed angle rotation matrix ultrasound array "channel estimation" JTRS sdr on fpga sonar rf front end
Text: computation. A good example that we will discuss here is that of adaptive beamforming . Beamforming is not only a military entity found in Naval sonar and airborne surveillance, but also is found in 3G cellular, medical ultrasound and phased-array radar. Systolic Array Processor for Beamforming Array , ranging from radar, sonar , geo-/astrophysical exploration, and biomedical signal processing to wireless , array. Some examples are Multi-User Detection, Channel Estimation and Adaptive Beamforming . The


Original
PDF
2011 - hifu

Abstract: pin diagram of ka 3525 C2BPB MD2131 ultrasound TRANSFORMER ultrasound transducer transformer ic 3525 internal block diagram sonar beamforming mems transducer
Text: , push-pull source driver. It is designed for medical ultrasound imaging and HIFU beamforming applications. It also can be used in NDT, Sonar and other ultrasound phase-array focusing beamforming applications. The , NDT and Sonar phase arrays HIFU transducer phase arrays beamforming and focus scanning Piezoelectric , Supertex inc. Features General Description MD2131 High Speed Ultrasound Beamforming Source , -P maximum output, uses two DN2625 FETs Angle vector beamforming I-Q switcher matrix 8-bit apodization DAC


Original
PDF MD2131 230VP-P DN2625 250MHz 25MHz MD2131 DSFP-MD2131 A092011 hifu pin diagram of ka 3525 C2BPB ultrasound TRANSFORMER ultrasound transducer transformer ic 3525 internal block diagram sonar beamforming mems transducer
2012 - sonar tr switch

Abstract: pin diagram of ka 3525 hifu 64-sample C2BPB ultrasound block diagram DSFP-MD2131
Text: , push-pull source driver. It is designed for medical ultrasound imaging and HIFU beamforming applications. It also can be used in NDT, Sonar and other ultrasound phase-array focusing beamforming applications. The , NDT and Sonar phase arrays HIFU transducer phase arrays beamforming and focus scanning Piezoelectric , Supertex inc. Features General Description MD2131 High Speed Ultrasound Beamforming Source , -P maximum output, uses two DN2625 FETs Angle vector beamforming I-Q switcher matrix 8-bit apodization DAC


Original
PDF MD2131 230VP-P DN2625 250MHz 25MHz MD2131 DSFP-MD2131 C102412 sonar tr switch pin diagram of ka 3525 hifu 64-sample C2BPB ultrasound block diagram
2011 - pin diagram of ka 3525

Abstract: sonar tr switch MD2131
Text: , push-pull source driver. It is designed for medical ultrasound imaging and HIFU beamforming applications. It also can be used in NDT, Sonar and other ultrasound phase-array focusing beamforming applications. The , imaging transmit beamforming High resolution NDT and Sonar phase arrays HIFU transducer phase arrays , Supertex inc. Features General Description MD2131 High Speed Ultrasound Beamforming Source , 230VP-P maximum output, uses two DN2625 FETs Angle vector beamforming I-Q switcher matrix 8


Original
PDF MD2131 230VP-P DN2625 250MHz 25MHz MD2131 DSFP-MD2131 A083111 pin diagram of ka 3525 sonar tr switch
radar using ultrasonic sensor

Abstract: sonar beamforming beamforming MHZ ULTRASONIC transducers Ultrasonic FLOW Transducer ULTRASONIC transducers Mhz circuit diagram of transducer ultrasound transducers heart pulse rate ultrasound ultrasonic transducer circuit
Text: C6201 DSPs for Medical Ultrasound Beamforming Rodger H. Hosking, Vice-president, Pentek, Inc , resolution. Principles of Beamforming Beamforming techniques are not only used in medical systems but also in speech, sonar , radar, wireless communication, radio telescopes, and even in tactical weapons. In general, beamforming is a technique for strategically combining signals from multiple sources to create an significantly enhanced version of any single source. Beamforming is useful both for receiving


Original
PDF C6201 radar using ultrasonic sensor sonar beamforming beamforming MHZ ULTRASONIC transducers Ultrasonic FLOW Transducer ULTRASONIC transducers Mhz circuit diagram of transducer ultrasound transducers heart pulse rate ultrasound ultrasonic transducer circuit
ultrasound transducer transformer

Abstract: ultrasound transducer circuit oscillator sonar beamforming MD1230 ultrasound transducer circuit pulse cpld ultrasound transducer 10MHz ultrasound transducer circuit driver ultrasound sonar Design -5V dc power supply using center-tapped transformer MD2130
Text: ultrasound imaging and HIFU beamforming applications. It also can be used in NDT, sonar and other ultrasound phase-array focusing beamforming applications. This demo board data sheet describes how to use the MD2130DB1 to generate the ultrasound transmit beamforming waveform with the Gaussian profile, and , MD2130DB1 MD2130 Ultrasound Beamforming Transmitter Demoboard Introduction General Description , the data register's per-scan-line for changing the beamforming phase angles and apodization


Original
PDF MD2130DB1 MD2130 MD2130DB1 TN7124 digi73K BAT54DW-7 TN7124K7 1/16W ultrasound transducer transformer ultrasound transducer circuit oscillator sonar beamforming MD1230 ultrasound transducer circuit pulse cpld ultrasound transducer 10MHz ultrasound transducer circuit driver ultrasound sonar Design -5V dc power supply using center-tapped transformer
2010 - ultrasound transducer transformer

Abstract: 750340727 ultrasound 40khz transducer high power driver 40khz ULTRASOUND DRIVER ultrasound transducer circuit oscillator ultrasound transducer circuit pulse cpld 40khz high power ULTRASOUND DRIVER MD2130 ultrasound TRANSFORMER WIDEBAND ULTRASOUND PULSE TRANSFORMER
Text: HIFU beamforming applications. It also can be used in NDT, sonar and other ultrasound phase-array focusing beamforming applications. The MD2130's output stage is designed to drive two depletion mode , Supertex inc. MD2130DB2 MD2130 Ultrasound Beamforming Transmitter Demoboard Introduction , changing the beamforming phase angles and apodization amplitudes. Demoboard Block Diagram +3.3V JTAG , how to use the MD2130DB2 to generate the ultrasound transmit beamforming waveform with the Gaussian


Original
PDF MD2130DB2 MD2130 ultrasound transducer transformer 750340727 ultrasound 40khz transducer high power driver 40khz ULTRASOUND DRIVER ultrasound transducer circuit oscillator ultrasound transducer circuit pulse cpld 40khz high power ULTRASOUND DRIVER ultrasound TRANSFORMER WIDEBAND ULTRASOUND PULSE TRANSFORMER
2009 - 40khz ULTRASOUND with a sine wave oscillator

Abstract: ultrasound transducer 10MHz ultrasound transducer Input output waveforms ultrasound 40khz transducer high power driver 40khz high power ULTRASOUND DRIVER WIDEBAND ULTRASOUND PULSE TRANSFORMER ultrasound transducer circuit pulse cpld ultrasound transducer transformer ic 3525 pwm application for step down dc to dc co MD2130
Text: waveform push-pull source-driver. It is designed for medical ultrasound imaging and HIFU beamforming applications. It also can be used in NDT, sonar and other ultrasound phase-array focusing beamforming , MD2130DB2 MD2130 Ultrasound Beamforming Transmitter Demoboard Introduction General Description , quickly updates the data register's perscan-line for changing the beamforming phase angles and , ultrasound transmit beamforming waveform with the Gaussian profile, and the adjustable frequency, amplitude


Original
PDF MD2130DB2 MD2130 MD2130DB2 40khz ULTRASOUND with a sine wave oscillator ultrasound transducer 10MHz ultrasound transducer Input output waveforms ultrasound 40khz transducer high power driver 40khz high power ULTRASOUND DRIVER WIDEBAND ULTRASOUND PULSE TRANSFORMER ultrasound transducer circuit pulse cpld ultrasound transducer transformer ic 3525 pwm application for step down dc to dc co
2011 - MD2130

Abstract: C2BPB
Text: data register for changing the beamforming phase angles and apodization amplitudes. Applications Medical imaging ultrasound beamforming transmitter High resolution NDT and Sonar phase array , Supertex inc. Features General Description MD2130 High Speed Ultrasound Beamforming Source , beamforming I-Q switcher matrix 8-bit apodization DAC and 7.5° angular resolution Flexible , waveform push-pull sourcedriver. It is designed for medical ultrasound imaging and HIFU beamforming


Original
PDF MD2130 160MHz 250VP-P DN2625 MD2130 DSFP-MD2130 D072011 C2BPB
2009 - ultrasound transducer transformer

Abstract: sonar beamforming mems transducer pin diagram of ka 3525 MD2130 MO-220 Piezo Transducer ultrasonic EDGE22 ultrasonic piezoelectric transducer driver B0723
Text: per-scan-line fast updating the data register for changing the beamforming phase angles and apodization amplitudes. Medical imaging ultrasound beamforming transmitter High resolution NDT and Sonar phase array , MD2130 High Speed Ultrasound Beamforming Source Driver Features , beamforming I-Q switcher matrix 8-bit apodization DAC and 7.5° angular resolution Flexible , beamforming applications. The IC consists of CMOS digital logic input circuits, an 8-bit current DAC for the


Original
PDF MD2130 160MHz 250Vp-p DN2625 MD2130 DSFP-MD2130 B072309 ultrasound transducer transformer sonar beamforming mems transducer pin diagram of ka 3525 MO-220 Piezo Transducer ultrasonic EDGE22 ultrasonic piezoelectric transducer driver B0723
2010 - sonar beamforming

Abstract: ultrasound transducer transformer MD2130 hifu ultrasonic piezoelectric transducer driver EDGE22 pin diagram of ka 3525 ultrasound TRANSFORMER ultrasound transducer circuit driver Type NS ceramic cap
Text: achieve per-scan-line fast updating the data register for changing the beamforming phase angles and apodization amplitudes. Medical imaging ultrasound beamforming transmitter High resolution NDT and Sonar , Supertex inc. MD2130 High Speed Ultrasound Beamforming Source Driver Features , time resolution 250Vp-p maximum output, use two DN2625 MOSFETs Angle vector beamforming I-Q switcher , ultrasound imaging and HIFU beamforming applications. The IC consists of CMOS digital logic input circuits


Original
PDF MD2130 160MHz 250Vp-p DN2625 MD213in DSFP-MD2130 B072309 sonar beamforming ultrasound transducer transformer MD2130 hifu ultrasonic piezoelectric transducer driver EDGE22 pin diagram of ka 3525 ultrasound TRANSFORMER ultrasound transducer circuit driver Type NS ceramic cap
2010 - 40khz ULTRASOUND with a sine wave oscillator

Abstract: ultrasound transducer transformer smd x1 mosfet sot-363 ultrasound 40khz transducer high power driver 750340727 40khz ULTRASOUND DRIVER 40khz ULTRASOUND WIDEBAND ULTRASOUND ultrasound transducer circuit oscillator ultrasound transducer circuit driver
Text: HIFU beamforming applications. It also can be used in NDT, sonar and other ultrasound phase-array focusing beamforming applications. MD2130's output stage is designed to drive two depletion mode, high , Supertex inc. MD2130DB3 MD2130 Ultrasound Beamforming Transmitter Demoboard Introduction , serial data interface that quickly updates the data register's perscan-line for changing the beamforming , use the MD2130DB3 to generate the ultrasound transmit beamforming waveform with the Gaussian profile


Original
PDF MD2130DB3 MD2130 40khz ULTRASOUND with a sine wave oscillator ultrasound transducer transformer smd x1 mosfet sot-363 ultrasound 40khz transducer high power driver 750340727 40khz ULTRASOUND DRIVER 40khz ULTRASOUND WIDEBAND ULTRASOUND ultrasound transducer circuit oscillator ultrasound transducer circuit driver
2010 - Not Available

Abstract: No abstract text available
Text: minimal channel-to-channel ultrasound beamforming focus error. The device's differential outputs are , array and programmable LO phase generators for a complete CW beamforming solution. The LO phase , reel. *EP = Exposed pad. Applications Ultrasound Imaging Sonar *See the Ultrasound-Specific IMD3 , AC-coupling would cause an inability to ensure synchronization among beam-forming channels. The LVDS signal is , for ease of daisy-chaining CW channels for analog beamforming programming. No Connect. Leave this pin


Original
PDF MAX2037 12-Bit 22nV/Hz 120mW -70dBc MAX2038
2010 - quadrature detector ultrasound

Abstract: No abstract text available
Text: minimal channel-to-channel ultrasound beamforming focus error. The device's differential outputs are , array and programmable LO phase generators for a complete CW beamforming solution. The LO phase , reel. *EP = Exposed pad. Applications Ultrasound Imaging Sonar *See the Ultrasound-Specific IMD3 , AC-coupling would cause an inability to ensure synchronization among beam-forming channels. The LVDS signal is , for ease of daisy-chaining CW channels for analog beamforming programming. No Connect. Leave this pin


Original
PDF MAX2037 12-Bit 22nV/Hz 120mW -70dBc MAX2038 quadrature detector ultrasound
2009 - CTL115

Abstract: JESD51-7 MAX1436 MAX2034 MAX2035 VGIN850
Text: gain error to ensure minimal channel-to-channel ultrasound beamforming focus error. The device , an octal quadrature mixer array and programmable LO phase generators for a complete CW beamforming , guaranteed over a 0°C to +70°C temperature range. Applications Ultrasound Imaging Sonar Ordering , to ensure synchronization among beamforming channels. The LVDS signal is terminated differentially , beamforming programming. 51 LO7 52 VGOUT7+ CW LO Input for Channel 7. LO clock input for modes


Original
PDF MAX2036 10-bit C100E MAX2036 CTL115 JESD51-7 MAX1436 MAX2034 MAX2035 VGIN850
2009 - sonar beamforming

Abstract: quadrature detector ultrasound ultrasound sonar CTL115 JESD51-7 MAX1436 MAX2034 MAX2035 VGIN850
Text: ultrasound beamforming focus error. The device's differential outputs are designed to directly drive , and programmable LO phase generators for a complete CW beamforming solution. The LO phase selection , Ultrasound Imaging Sonar Ordering Information PART TEMP RANGE MAX2036CCQ+D 0°C to +70°C , to ensure synchronization among beamforming channels. The LVDS signal is terminated differentially , beamforming programming. 51 LO7 52 VGOUT7+ CW LO Input for Channel 7. LO clock input for modes


Original
PDF MAX2036 10-bit C100E MAX2036 sonar beamforming quadrature detector ultrasound ultrasound sonar CTL115 JESD51-7 MAX1436 MAX2034 MAX2035 VGIN850
2009 - CTL115

Abstract: JESD51-7 MAX1436 MAX2034 MAX2035 VGIN850 quadrature mixer max2036evkit
Text: gain error to ensure minimal channel-to-channel ultrasound beamforming focus error. The device , an octal quadrature mixer array and programmable LO phase generators for a complete CW beamforming , Power Consumption per Channel (Low-Power Mode) Applications Ultrasound Imaging Sonar Ordering , to ensure synchronization among beamforming channels. The LVDS signal is terminated differentially , of daisy-chaining CW channels for analog beamforming programming. VGA Channel 8 Noninverting


Original
PDF MAX2036 10-bit MAX2036 CTL115 JESD51-7 MAX1436 MAX2034 MAX2035 VGIN850 quadrature mixer max2036evkit
2009 - quadrature detector ultrasound

Abstract: CTL115 JESD51-7 MAX1436 MAX2034 MAX2035 VGIN850 400hz SSR max2036evkit
Text: gain error to ensure minimal channel-to-channel ultrasound beamforming focus error. The device , an octal quadrature mixer array and programmable LO phase generators for a complete CW beamforming , Patents Related to Ultrasound Imaging Techniques Applications Ultrasound Imaging Sonar Ordering , to ensure synchronization among beamforming channels. The LVDS signal is terminated differentially , of daisy-chaining CW channels for analog beamforming programming. VGA Channel 8 Noninverting


Original
PDF MAX2036 10-bit MAX2036 quadrature detector ultrasound CTL115 JESD51-7 MAX1436 MAX2034 MAX2035 VGIN850 400hz SSR max2036evkit