The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
LT5527EUF#PBF Linear Technology LT5527 - 400MHz to 3.7GHz High Signal Level Downconverting Mixer; Package: QFN; Pins: 16; Temperature Range: -40°C to 85°C
LT5527EUF#TR Linear Technology LT5527 - 400MHz to 3.7GHz High Signal Level Downconverting Mixer; Package: QFN; Pins: 16; Temperature Range: -40°C to 85°C
LT5511EFE#PBF Linear Technology LT5511 - High Signal Level Upconverting Mixer; Package: TSSOP; Pins: 16; Temperature Range: -40°C to 85°C
LT5522EUF#PBF Linear Technology LT5522 - 600MHz to 2.7GHz High Signal Level Downconverting Mixer; Package: QFN; Pins: 16; Temperature Range: -40°C to 85°C
LT5527EUF#TRPBF Linear Technology LT5527 - 400MHz to 3.7GHz High Signal Level Downconverting Mixer; Package: QFN; Pins: 16; Temperature Range: -40°C to 85°C
LT5511EFE#TRPBF Linear Technology LT5511 - High Signal Level Upconverting Mixer; Package: TSSOP; Pins: 16; Temperature Range: -40°C to 85°C

signal strength meter Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
2008 - signal strength meter

Abstract: No abstract text available
Text: COMMUNICATIONS TeST & MeASUreMeNT SOlUTIONS Satellite Signal Strength Meter Key Features · , ultra-fine tuning capability · Powered by satellite receiver-no batteries required The Satellite Signal Strength Meter is a simple, easy-to-use mechanical device used to maximize a satellite signal between the , direct satellite systems webSITe : www.jdsu.com/know Satellite Signal Strength Meter , Satellite Signal Strength Meter CS300 warranty JDSU guarantees that its products will be free of all


Original
PDF
2005 - signal strength meter

Abstract: RF Transmitter 315MHz rf 315mhz LED display for radio meter led bargraph meter 315MHz RF
Text: RF HAND HELD RF METER · · · · · · · · · Hand Held Signal Strength Meter Detects Carrier RF Activity 10 digit LED Display with Peak Hold Displays -108dBm to ­40dBm Signal Strength , Meter which can be used to show the presence of a Radio Signal . Briefly press the power switch and the LED bargraph shows the RF activity within the local environment. The peak signal is held for 1 second , (interference) and also validate the signal strength of the radio transmitter to be installed. Green represents


Original
PDF -108dBm 40dBm 84MHz 50MHz DS066-4 signal strength meter RF Transmitter 315MHz rf 315mhz LED display for radio meter led bargraph meter 315MHz RF
2001 - MC3356 transmitter

Abstract: NE602 application note NE602 down converter K2638 MC3850
Text: connected and buffered to produce a signal strength meter drive which is fairly linear for IF input signals , signal strength at which this occurs can be adjusted by changing the meter load resistor. The comparator , Components of Signal , Noise, and Distortion 10 S+N+D 700 METER CURRENT, PIN 14 (µA) 600 500 400 300 200 100 0 0.010 0.1 1.0 10 PIN 20 INPUT (mVrms) 100 1000 Figure 4. Meter Current versus Signal Input , strength meter drive, and data shaping amplifier. The oscillator is a common base Colpitts type which can


Original
PDF MC3356 MC3356 NE602 MC3356 transmitter NE602 application note NE602 down converter K2638 MC3850
wideband fsk receiver

Abstract: fsk modulator colpitts IF AMPLIFIER AND DETECTOR signal path designer
Text: , lim iting IF, quadrature detector, signal strength meter drive, and data shaping amplifier. The , unusual in that each of the last 5 stages of the 6 state lim iter contains a signal strength sensitive, current sinking device. These are parallel connected and buffered to produce a signal strength meter drive , . AND DISTORTION FIGURE 5 - METER CURRENT versus SIGNAL INPUT INPUT (mVrms) PIN 20 INPUT , comparator at about 0.8 Vdc above ground. The signal strength at w hich this occurs can be adjusted by


OCR Scan
PDF MC3356 MC3356 wideband fsk receiver fsk modulator colpitts IF AMPLIFIER AND DETECTOR signal path designer
NE602 down converter

Abstract: MC3356 mc3850 wideband fsk receiver signal path designer SFE107 MC3356DW
Text: an oscillator, mixer, limiting IF, quadrature detector, signal strength meter drive, and data shaping , MC3356 Figure 3. Output Components of Signal , Noise, and Distortion Figure 4. Meter Current versus , . The IF is unusual in that each of the last 5 stages of the 6 state limiter contains a signal strength sensitive, current sinking device. These are parallel connected and buffered to produce a signal strength , a comparator at about 0.8 Vdc above ground. The signal strength at which this occurs can be adjusted


OCR Scan
PDF MC3356 NE602 SQ-20L) MC3356 NE602 down converter mc3850 wideband fsk receiver signal path designer SFE107 MC3356DW
NE602 down converter

Abstract: signal strength meter MC3850 MURATA SFE10.7 signal path designer
Text: IF, quadrature detector, signal strength meter drive, and data shaping amplifier. The oscillator is a , unusual in that each of the last 5 stages of the 6 state limiter contains a signal strength sensitive, current sinking device. These are parallel connected and buffered to produce a signal strength meter drive , o f Signal , Noise, and Distortion Figure 4. Meter Current versus Signal Input INPUT imVrms , at about 0.8 Vdc above ground. The signal strength at which this occurs can be adjusted by changing


OCR Scan
PDF MC3356 NE602 SQ-20L) MC3356 NE602 down converter signal strength meter MC3850 MURATA SFE10.7 signal path designer
C3356

Abstract: MURATA SFE10.7 signal path designer SFE107 signal strength meter
Text: stages of the 6 state limiter contains a signal strength sensitive, current sinking device. These are parallel connected and buffered to produce a signal strength meter drive which is fairly linear for IF , ground. The signal strength at which this occurs can be adjusted by changing the meter load resistor. The , OUTPUT COMPONENTS OF SIGNAL , NOISE, AND DISTORTION T-77-05-05 FIGURE 5 - METER CURRENT versus , strength meter drive, and data shaping amplifier. The oscillator is a com m on base Coipitts type which can


OCR Scan
PDF MC3356 C3356 77dulator T-77-05-05 MURATA SFE10.7 signal path designer SFE107 signal strength meter
signal strength meter

Abstract: DS968 MC13055 MC3356 C41722
Text: signal strength at which this occurs can be adjusted by changing the meter load resistor. The ~,mparator , connected and buffered to produce a signal strength meter drive which . a +., ~:. , `" , been revised to a balanced configuration. The excellent signal strength metering circuit has been retained, as has the versatile data slicer/ comparator. q Input Sensitivity q Signal Strength , ,* DESCRIPTION The MC13055 is an extended frequency range FM IF, quadrature detector, signal strength


Original
PDF MC13055/D MC13055 MC13055 MC3356, signal strength meter DS968 MC3356 C41722
13055P

Abstract: c3356
Text: configuration. The received signal strength metering circuit has been retained, as has the versatile data slicer/comparator. · Input Sensitivity 20 (¿V @ 40 MHz · Signal Strength Indicator Linear Over 3 Decades · Available , 3.2-301 MC13055 Figure 4. Meter Current versus Signal -100 -60 -60 -4 0 SIGNAL INPUT (dBm , extended frequency range FM IF, quadrature detector, signal strength detector and data shaper. It is , . The IF is unusual in that each of the last 5 stages of the 6 stage limiter contains a signal strength


OCR Scan
PDF MC13055 MC3356, 13055P c3356
1999 - EN 50065-4

Abstract: CENELEC EN 50065 EIA-709 PLT-21 EIA709 PLCA-22 PLT-22 78200se 1N53438 push pull booster amplifiers
Text: Display Coupling Circuits Status LEDs Signal Strength Meter RS-232 Communication Port 16-key Keypad , conditions. * l Signal Strength Meter . f Niveau du Signal Signal Strength 0 dB = 3.5 Vp-p , corresponding levels in the secondary carrier band. The signal strength meter has LEDs for -78, -72, -66, -60 , percentage of the total number of packets sent. A pair of calibrated receive signal strength meters also is , occurs for cases where the received packet signal strength is less than 8OdBpV and greater than 30dBpV


Original
PDF PLCA-22 1994/Al 61000-4-S 50065-l k1997 EN 50065-4 CENELEC EN 50065 EIA-709 PLT-21 EIA709 PLT-22 78200se 1N53438 push pull booster amplifiers
1995 - Not Available

Abstract: No abstract text available
Text: oscillator, mixer, limiting IF, quadrature detector, signal strength meter drive, and data shaping , connected and buffered to produce a signal strength meter drive which is fairly linear for IF input , ground. The signal strength at which this occurs can be adjusted by changing the meter load resistor , MC3356 Figure 3. Output Components of Signal , Noise, and Distortion Figure 4. Meter Current versus Signal Input 10 700 S+N+D METER CURRENT, PIN 14 (µA) RELATIVE OUTPUT (dB) 0 fO = 100 MHz


Original
PDF MC3356/D MC3356 MC3356 NE602 MC3356/D*
2005 - NE602

Abstract: k3484 NE602 down converter MC3356P NE602 application note MC3850 signal strength meter ML3356-6P NE602 application BLOCK DIAGRAM NE602
Text: stages of the 6 state limiter contains a signal strength sensitive, current sinking device. These are parallel connected and buffered to produce a signal strength meter drive which is fairly linear for IF , Semiconductor, Inc. Figure 3. Output Components of Signal , Noise, and Distortion Figure 4. Meter Current versus Signal Input 10 700 S+N+D METER CURRENT, PIN 14 (µA) RELATIVE OUTPUT (dB) 0 fO = , strength meter drive, and data shaping amplifier. The oscillator is a common base Colpitts type which can


Original
PDF ML3356 MC3356 ML3356 NE602 NE602 k3484 NE602 down converter MC3356P NE602 application note MC3850 signal strength meter ML3356-6P NE602 application BLOCK DIAGRAM NE602
1996 - NE602 ic

Abstract: K3484 digital frequency meter circuit diagram NE602 down converter K2770 rf ne602 MC3356 Motorola NE602 application SFE10 MC3356DW
Text: , limiting IF, quadrature detector, signal strength meter drive, and data shaping amplifier. The oscillator , MC3356 Figure 3. Output Components of Signal , Noise, and Distortion Figure 4. Meter Current versus Signal Input 10 700 S+N+D METER CURRENT, PIN 14 (µA) RELATIVE OUTPUT (dB) 0 fO = 100 MHz , . The IF is unusual in that each of the last 5 stages of the 6 state limiter contains a signal strength sensitive, current sinking device. These are parallel connected and buffered to produce a signal strength


Original
PDF MC3356/D MC3356 MC3356 NE602 NE602 ic K3484 digital frequency meter circuit diagram NE602 down converter K2770 rf ne602 MC3356 Motorola NE602 application SFE10 MC3356DW
2008 - MC3356P

Abstract: MV209 diode MC145170 NE602 down converter NE602 SFE10 K3484 ML3356-6P ML3356 MC3356
Text: stages of the 6 state limiter contains a signal strength sensitive, current sinking device. These are parallel connected and buffered to produce a signal strength meter drive which is fairly linear for IF , . ML3356 Figure 3. Output Components of Signal , Noise, and Distortion Figure 4. Meter Current versus Signal Input 10 700 RELATIVE OUTPUT (dB) 0 METER CURRENT, PIN 14 (µA) S+N+D fO = 100 , strength meter drive, and data shaping amplifier. The oscillator is a common base Colpitts type which can


Original
PDF ML3356 MC3356 ML3356 NE602 MC3356P MV209 diode MC145170 NE602 down converter NE602 SFE10 K3484 ML3356-6P MC3356
2001 - UNI-10

Abstract: wireless audio transmitter schematic wireless audio transmitter receiver schematic wideband fsk receiver mc1305 MC13055D MC3356 transmitter
Text: parallel connected and buffered to produce a signal strength meter drive which is fairly linear for IF , . The signal strength at which this occurs can be adjusted by changing the meter load resistor. The , received signal strength metering circuit has been retained, as has the versatile data slicer/comparator. · , Signal Strength Indicator Linear Over 3 Decades Available in Surface Mount Package Easy Application, Few , kHz 30% Noise l12, METER CURRENT (µ A) Figure 4. Meter Current versus Signal NOT RECOMMENDED FOR


Original
PDF MC13055 MC13055 MC3356, UNI-10 wireless audio transmitter schematic wireless audio transmitter receiver schematic wideband fsk receiver mc1305 MC13055D MC3356 transmitter
1996 - NE602 down converter

Abstract: NE602 signal strength meter k3484 NE602 application note MC3850 MC3356DW BLOCK DIAGRAM NE602 MURATA SFE10.7 MHZ SFE10
Text: 5 stages of the 6 state limiter contains a signal strength sensitive, current sinking device. These are parallel connected and buffered to produce a signal strength meter drive which is fairly , 0.8 Vdc above ground. The signal strength at which this occurs can be adjusted by changing the meter , strength meter drive, and data shaping amplifier. The oscillator is a common base Colpitts type which can , ORDER 15JAN02 LAST SHIP 27DEC02 Figure 4. Meter Current versus Signal Input MC3356 Car. Det


Original
PDF MC3356 MC3356 NE602 MC3356/D 15JAN02 27DEC02 NE602 down converter NE602 signal strength meter k3484 NE602 application note MC3850 MC3356DW BLOCK DIAGRAM NE602 MURATA SFE10.7 MHZ SFE10
1996 - NE602 application note

Abstract: MC3356 NE602 equivalent audio limiter ic NE602 down converter KBF10 quadrature detector NE602 application NE602 audio squelch circuit
Text: , quadrature detector, signal strength meter drive, and data shaping amplifier. The oscillator is a common , unusual in that each of the last 5 stages of the 6 state limiter contains a signal strength sensitive, current sinking device. These are parallel connected and buffered to produce a signal strength meter , . MC3356 Figure 3. Output Components of Signal , Noise, and Distortion Figure 4. Meter Current versus , a comparator at about 0.8 Vdc above ground. The signal strength at which this occurs can be


Original
PDF MC3356/D MC3356 MC3356 NE602 NE602 application note NE602 equivalent audio limiter ic NE602 down converter KBF10 quadrature detector NE602 application NE602 audio squelch circuit
2008 - hardware and networking notes

Abstract: Wireless Microcontroller signal strength meter JN5139 JN5139-EK020 microcontroller based wireless home automation
Text: Wireless UART o Packet Error Rate tester o RF Signal strength meter Kit Contents · 3 sensor nodes , performance testing such as signal strength and Packet Error Rate. The starter kit can be expanded with


Original
PDF JN5139-EK020 IEEE802 19F-1, JN5139-EK020-PB hardware and networking notes Wireless Microcontroller signal strength meter JN5139 JN5139-EK020 microcontroller based wireless home automation
1996 - NE602 application note

Abstract: BLOCK DIAGRAM NE602 ne602 K3626 NE602 equivalent MC3356DW SFE10,7 KBF10 NE602 down converter MC3356P
Text: oscillator, mixer, limiting IF, quadrature detector, signal strength meter drive, and data shaping , contains a signal strength sensitive, current sinking device. These are parallel connected and buffered to produce a signal strength meter drive which is fairly linear for IF input signals of 10 µV to 100 mVrms , the meter load resistance flips a comparator at about 0.8 Vdc above ground. The signal strength at , Figure 3. Output Components of Signal , Noise, and Distortion Figure 4. Meter Current versus Signal


Original
PDF MC3356/D MC3356 NE602 MC3356 NE602 application note BLOCK DIAGRAM NE602 ne602 K3626 NE602 equivalent MC3356DW SFE10,7 KBF10 NE602 down converter MC3356P
Not Available

Abstract: No abstract text available
Text: , quadrature detector, signal strength meter drive, and data shaping amplifier. The oscillator is a common , , Inc. ML3356 Figure 3. Output Components of Signal , Noise, and Distortion Figure 4. Meter Current versus Signal Input 10 700 S+N+D METER CURRENT, PIN 14 (µA) RELATIVE OUTPUT (dB) 0 , IF is unusual in that each of the last 5 stages of the 6 state limiter contains a signal strength sensitive, current sinking device. These are parallel connected and buffered to produce a signal strength


Original
PDF ML3356 MC3356 ML3356 NE602
Not Available

Abstract: No abstract text available
Text: parallel connected and buffered to produce a signal strength meter drive which is fairly linear for IF , ground. The signal strength at which this occurs can be adjusted by changing the meter load resistor. The , to a balanced configuration. The excellent signal strength metering circuit has been retained, as has the versatile data slicer/ comparator. · Input Sensitivity 20 /¿V @ 40 MHz · Signal Strength Indicator , GAIN. NOISE, A M REJECTION FIGURE 4 - METER CURRENT versus SIGNAL RELATIVE OUTPUT (dB) SIG N


OCR Scan
PDF MC13055 MC13055 MC3356,
2013 - 2000-1411-R

Abstract: MS2034B-0411
Text: -axis rotation viewing control Identifying Interference Signal Strength Meter Can locate an interfering signal , by using a directional antenna and measuring the signal strength and by an audible beep , identified, the Signal Strength Meter with its audible output beep coupled with a directional antenna , Meter • Received Signal Strength Indicator (RSSI) • Signal ID (up to 12 signals) • FM • GSM , drive. Received Signal Strength Indicator • Spectrogram Spectrogram Save-on-Event â


Original
PDF MS2024B MS2025B MS2034B MS2035B MS202xB/3xB MS203xB 2000-1411-R MS2034B-0411
2013 - Not Available

Abstract: No abstract text available
Text: a 2-digit signal strength meter integral with the product. Listed for operation from –22o F to , gunsight, integral signal Alignment Aid: strength indication, 2-digit display. On smooth ceilings, 0 - , reflector, it causes a reduction in the signal , and when the smoke level reaches the predetermined , procedure. • Operates with an integral automatic gain control that compensates for signal deterioration


Original
PDF BEAM1224 BEAM1224 BEAM1224S RTS151 RTS151KEY
2005 - Not Available

Abstract: No abstract text available
Text: accomplished with an optical sight and a two-digit signal strength meter incorporated into the beam detector , the area between the unit and the reflector, it causes a reduction in the signal strength . When the smoke level ( signal strength ) reaches the predetermined threshold, an alarm is activated. The , signal deterioration from dust buildup. • Optional remote test station. • Optional long-range kit , : nominal 1.6 W @ 24 V; maximum 3.0 W @ 32 V. Alignment aid: • Optical gunsight. • Integral signal


Original
PDF CS-2507 BEAM1224 BEAM1224S BEAM1224S ft/70
2013 - Not Available

Abstract: No abstract text available
Text: via an optical sight and a 2-digit signal strength meter integral with the product. Listed for , unit and the reflector, it causes a reduction in the signal , and when the smoke level reaches the , gain control that compensates for signal deterioration from dust build-up. • Available with an


Original
PDF RTS151 RTS151KEY
Supplyframe Tracking Pixel