Part Manufacturer Description Datasheet Download Buy Part
LT1319CS Linear Technology IC INFRARED, RECEIVER IC, PDSO16, 0.150 INCH, PLASTIC, SO-16, Remote Control IC
LT1319CS#PBF Linear Technology IC INFRARED, RECEIVER IC, PDSO16, 0.150 INCH, PLASTIC, SO-16, Remote Control IC
LTC2997CDCB#TRMPBF-ES Linear Technology LTC2997 - Remote/Internal Temperature Sensor; Package: DFN; Pins: 6; Temperature: Commercial
LTC2997HDCB#TRPBF Linear Technology LTC2997 - Remote/Internal Temperature Sensor; Package: DFN; Pins: 6; Temperature Range: -40°C to 125°C
LTC2997CDCB#TRPBF-ES Linear Technology LTC2997 - Remote/Internal Temperature Sensor; Package: DFN; Pins: 6; Temperature: Commercial
LTC2997IDCB#PBF Linear Technology LTC2997 - Remote/Internal Temperature Sensor; Package: DFN; Pins: 6; Temperature Range: -40°C to 85°C

remote transmiter Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
1999 - circuit diagram of rf transmitter and receiver in

Abstract:
Text: System Overview The system described here receives data from an IR remote control and converts it to an , of the set-top box is assumed to be microcontroller inputs. Introduction IR (infrared) remote , located in another room where its IR remote control is unusable (see Figure 1). IR Receiver to RF , signal. INFRARED Remote TV O DI RA VS 5V INFRARED TX Data C1 4.7µF IR1 , remote control; TX1 is a LPRS (Low Power Radio Solutions) LQTX433A-S 433.92MHz SAW-based


Original
PDF
2005 - Variable Area Rotameter

Abstract:
Text: Differential Pressure 6 38 3 2088 Absolute Pressure Tx with Remote Seal 3 38 35 , 1 22 8 TTX 200 Temperature Transmiter 2 26 13 TTX 300 Temperature Transmiter 1 26 11 TTX 300 Temperature Transmiter 2 26 11 Accutech AI , .03.00 Temperature Transmitter 2 17 202 iTemp / TMT 182 / V1.1 Temperature Transmiter 2 17 200 RTT 15 Temperature Transmiter 1 20 56 Category Vendor Device Type 1


Original
PDF 800xA TB82PH TB82PH-Combined TB82TC-Combined TB82TE-Combined LB491 X3301 3BDD013118 Variable Area Rotameter fmx siemens MASONEILAN VALVE ultrasonic flow meter rtt 10 foxboro foxboro FLOW METER turbine masoneilan MASONEILAN SVI ii Vortex flowmeter panametrics xmt 868
2006 - MDIO clause 45

Abstract:
Text: oscillator, and intelligent clock management circuitry to automatically perform remote radio head , ( remote ) loop back mode, the output de-emphasis control is disabled. LOOP [1] LOOP [0] 0 0 Normal mode-no loop back 0 1 Line ( remote ) loop back mode 1 0 Local loop back mode 1 1 Special line ( remote ) loop back mode MDC/MDIO 30 31 37 36 35 34 33 MDC MDIO , Reset (Note 11) tTX-RST Transmiter Reset TXPWDNB = 0 1 us tRX-RST Receiver Reset


Original
PDF SCAN12100 SCAN12100 MDIO clause 45 78 los TQFP 100 PACKAGE SCAN25100 SCAN12100TYA remote transmiter remote control transmiter MDIO clause 45 specification AVDD33
2006 - MDIO clause 45

Abstract:
Text: automatically perform remote radio head synchronization and reduce the cost and complexity of external clock , ( remote ) loop back mode, the output de-emphasis control is disabled. LOOP [1] 0 0 1 1 MDC/MDIO 30 31 37 36 , 0 1 Normal mode-no loop back Line ( remote ) loop back mode Local loop back mode Special line ( remote , tW-TRST tREC T14 Toffset Tser Tdes Tin-out Tout-in (13) (14) (15) (16) Transmiter Reset Receiver Reset , www.ti.com SNLS223C ­ SEPTEMBER 2006 ­ REVISED APRIL 2013 SYSCLK can be used to synchronize remote radio


Original
PDF SCAN25100 SNLS223C SCAN25100 MDIO clause 45
Not Available

Abstract:
Text: , on-chip oscillator, and intelligent clock management circuitry to automatically perform remote radio head , line ( remote ) loop back mode, the output de-emphasis control is disabled. LOOP [1] LOOP [0] 0 0 Normal mode- no loop back 0 1 Line ( remote ) loop back mode 1 0 Local loop back mode 1 1 Special line ( remote ) loop back mode MDC/MDIO 30 31 37 36 35 34 33 , Reset (Note 12) *TX-RST Transmiter Reset TXPWDNB = 0 1 us *RX-RST Receiver Reset


OCR Scan
PDF SCAN12100 SNLS245D SCAN12100 I7nl200ps
2006 - Not Available

Abstract:
Text: PLLs, on-chip oscillator, and intelligent clock management circuitry to automatically perform remote , configuration. Pulling both pins low enables MDIO control. Note: During Special line ( remote ) loop back mode , back 0 1 Line ( remote ) loop back mode 1 0 Local loop back mode 1 1 Special line ( remote ) loop back mode MDC/MDIO 30 31 37 36 35 34 33 MDC MDIO ADD0 ADD1 ADD2 , ns (14) tTX-RST Transmiter Reset TXPWDNB = 0 1 us tRX-RST Receiver Reset


Original
PDF SCAN25100 SNLS223C SCAN25100
2006 - Not Available

Abstract:
Text: automatically perform remote radio head synchronization and reduce the cost and complexity of external clock , ( remote ) loop back mode, the output de-emphasis control is disabled. LOOP [1] 0 0 1 1 MDC/MDIO 30 31 37 36 , 0 1 Normal mode-no loop back Line ( remote ) loop back mode Local loop back mode Special line ( remote , tW-TRST tREC T14 Toffset Tser Tdes Tin-out Tout-in (13) (14) (15) (16) Transmiter Reset Receiver Reset , www.ti.com SNLS223C ­ SEPTEMBER 2006 ­ REVISED APRIL 2013 SYSCLK can be used to synchronize remote radio


Original
PDF SCAN25100 SNLS223C SCAN25100
2008 - BTS 5010

Abstract:
Text: remote radio head synchronization and reduce the cost and complexity of external clock networks. The , line ( remote ) loop back mode, the output de-emphasis control is disabled. LOOP [1] LOOP [0] 0 0 Normal mode-no loop back 0 1 Line ( remote ) loop back mode 1 0 Local loop back mode 1 1 Special line ( remote ) loop back mode MDC/MDIO 30 31 37 36 35 34 33 , 470 pF 300 ns 1 ns MINIMUM PULSE WIDTH, Hardware Reset (Note 13) tTX-RST Transmiter


Original
PDF SCAN25100 SCAN25100 BTS 5010 MDIO clause 45 SCAN25100TYA remote transmiter 78 los AVDD33 ask transmiter 802.3ae MDIO TQFP-100
2006 - Not Available

Abstract:
Text: PLLs, on-chip oscillator, and intelligent clock management circuitry to automatically perform remote , configuration. Pulling both pins low enables MDIO control. Note: During Special line ( remote ) loop back mode , back 0 1 Line ( remote ) loop back mode 1 0 Local loop back mode 1 1 Special line ( remote ) loop back mode MDC/MDIO 30 31 37 36 35 34 33 MDC MDIO ADD0 ADD1 ADD2 , ns (14) tTX-RST Transmiter Reset TXPWDNB = 0 1 us tRX-RST Receiver Reset


Original
PDF SCAN25100 SNLS223C SCAN25100
2008 - MDIO clause 45

Abstract:
Text: automatically perform remote radio head synchronization and reduce the cost and complexity of external clock , ( remote ) loop back mode, the output de-emphasis control is disabled. LOOP [1] 0 0 1 1 LOOP [0] 0 1 0 1 Normal mode-no loop back Line ( remote ) loop back mode Local loop back mode Special line ( remote ) loop , MINIMUM PULSE WIDTH, Hardware Reset (Note 13) tTX-RST tRX-RST tRST Transmiter Reset Receiver Reset SerDes , can be used to synchronize remote radio heads since it provides a local 30.72 MHz internal clock which


Original
PDF SCAN25100 SCAN25100 SNLS223B SCAN251002457 MDIO clause 45 HF RFID loop antenna design BTS 5010 MDIO clause 45 specification remote control transmiter
2006 - Not Available

Abstract:
Text: , on-chip oscillator, and intelligent clock management circuitry to automatically perform remote radio head , ( remote ) loop back mode, the output de-emphasis control is disabled. LOOP [1] LOOP [0] 0 0 Normal mode—no loop back 0 1 Line ( remote ) loop back mode 1 0 Local loop back mode 1 1 Special line ( remote ) loop back mode MDC/MDIO 30 31 37 36 35 34 33 MDC MDIO , ) 300 ns (12) tTX-RST Transmiter Reset TXPWDNB = 0 1 us tRX-RST Receiver


Original
PDF SCAN12100 SNLS245D SCAN12100 SCAN25100
2008 - MDIO clause 45

Abstract:
Text: oscillator, and intelligent clock management circuitry to automatically perform remote radio head , both pins low enables MDIO control. pull down Note: During Special line ( remote ) loop back mode, the , 0 1 Line ( remote ) loop back mode 1 0 Local loop back mode 1 1 Special line ( remote ) loop back mode MDC/MDIO 30 31 37 36 35 34 33 MDC MDIO ADD0 ADD1 ADD2 ADD3 ADD4 , 300 ns 1 ns MINIMUM PULSE WIDTH, Hardware Reset (Note 12) tTX-RST Transmiter Reset


Original
PDF SCAN12100 SCAN12100 MDIO clause 45 SCAN25100 remote transmiter K28-1 NSC crystal 30.72MHz remote control rx tx mimo antenna MDIO MDC MDIO clause 45 specification TQFP-100
2006 - mimo antenna

Abstract:
Text: management circuitry to automatically perform remote radio head synchronization and reduce the cost and , enables MDIO control. Note: During Special line ( remote ) loop back mode, the output de-emphasis control is , 1.2V signal compatible. LOOP [0] 0 1 0 1 Normal mode-no loop back Line ( remote ) loop back mode Local loop back mode Special line ( remote ) loop back mode IEEE 1149.1 (JTAG) 3.3V LVTTL Internal pull up , to synchronize remote radio heads since it provides a local 30.72 MHz internal clock which is


Original
PDF SCAN12100 SNLS245E SCAN12100 SCAN25100 mimo antenna
2006 - Not Available

Abstract:
Text: management circuitry to automatically perform remote radio head synchronization and reduce the cost and , enables MDIO control. Note: During Special line ( remote ) loop back mode, the output de-emphasis control is , 1.2V signal compatible. LOOP [0] 0 1 0 1 Normal mode-no loop back Line ( remote ) loop back mode Local loop back mode Special line ( remote ) loop back mode IEEE 1149.1 (JTAG) 3.3V LVTTL Internal pull up , to synchronize remote radio heads since it provides a local 30.72 MHz internal clock which is


Original
PDF SCAN12100 SNLS245E SCAN12100 SCAN25100
RTL3139

Abstract:
Text: 18/24 Bit TTL Analog RGB VGA DDR SDRAM 200-pin SODIMM x 1 AMD Geode LX 800 LVDS Transmiter , an e-mail to a designated administrator. The eSOS also provides remote connection: Telnet server and


Original
PDF PCM-9375 PC/104 LX800 PC/104 24-bit 18-bit 9-May-2011 RTL3139 RTL8139 VGA TO LAN ic realtek rtl8139 PCM9375F PCM-9375FZ-J0A1E rtl8139 manual PCM-9375F-J0A1E REALTEK RTL PCM-9375F
Not Available

Abstract:
Text: perform remote radio head synchro­ nization and reduce the costand complexity of external clock , , Internal Pulling both pins low enables MDIO control. pull down Note: During Special line ( remote ) loop , - no loop back 0 1 Line ( remote ) loop back mode 1 0 Local loop back mode 1 1 Special line ( remote ) loop back mode MDC/MDIO 30 31 37 36 35 34 33 MDC MDIO ADDO ADD1 , Transmiter Reset TXPWDNB = 0 1 us *RX-RST Receiver Reset RXPWDNB = 0 1 us *RST


OCR Scan
PDF LS223B SCAN25100 I7nl200ps SCAN25100
HDB3 to nrz

Abstract:
Text: €¢ Built-in B3ZS/HDB3 Encoder and Decoder • Remote and Local Loopback Functions • Single 5V Power Supply , testing, both local and remote loop-backs are possible with the built-in loop-back circuit. The XRT7296 , . 2 RLOOP I Remote Loop Back. A high on this pin causes RPDATA and RNDATA to transmitted to the line , TNDATA are ignored. If remote loop back (RLOOP) is set high, any TAOS request is ignored. REMOTE , bead 'HU- c4 0.1 nF vccrx c7 0.1 nF 0.1 [if £ f b3 M r bpv®~~ I TRANSMITER I I MONITOR


OCR Scan
PDF TR-NWT-000499 XRT7296 XRT7296 HDB3 to nrz XRT7296IP XRT7295E XRT7295 XR-T7296IW XR-T7296 T7296 PCM encoder circuit ami XRT7296IW
Not Available

Abstract:
Text: Remote and local loop-back functions Single 5 V power supply APPLICATIONS Interface for SONET, DS , Receive Clock Input. Input sampling clock for RPDATA and RNDATA. 2 RLOOP I Remote Loop-Back. A , TNDATA are ignored. If remote loopback (R LO O P) is set high, any TAOS request is ignored. PULSE SHAPER REMOTE LOOP-BACK The pulse shaper circuit uses a combination of filters and slew rate control , GNDD r ' I I DMO < BPV < TRANSMITER MONITOR OUTPUTS I I I GNDA W 1 PE


OCR Scan
PDF XR-T7296 XR-T7296 XR-T7295 XR-T7295E
Not Available

Abstract:
Text: Encoder and Decoder • Remote and Local Loopback Functions • Single 5V Power Supply â , trouble-shooting and testing, both local and remote loop-backs are possible with the built-in loop-back circuit , I Remote Loop Back. A high on this pin causes RPDATA and RNDATA to transmitted to the line using , 1s to be transmitted to the line. In this mode, input TPDATA and TNDATA are ignored. If remote loop , mode all bipolar violation pulses are indicated at the BPV pin. BIPOLAR VIOLATION REMOTE LOOP-BACK


OCR Scan
PDF XRT7296 TR-NWT-000499
1988 - cmo 1605

Abstract:
Text: BU-65142 and BUS-65142 SERIES MIL-STD-1553 DUAL REDUNDANT REMOTE TERMINAL HYBRID DESCRIPTION The BUS-65142 Series is a complete dual redundant MIL-STD1553 Remote Terminal Unit (RTU) packaged in a , . FEATURES · Complete Intergrated Remote Terminal Including: ­Dual Low-Power Transceivers ­Complete RT , -65142 is a complete dual redundant Remote Terminal Unit (RTU) packaged in a small 1.9 x 2.1 hybrid. It is , to RT address error T/R bit error. The RTFAIL ( Remote Terminal Failure) line goes LOW whenever the


Original
PDF BU-65142 BUS-65142 MIL-STD-1553 MIL-STD1553 1-800-DDC-5757 A5976 N--10/99 cmo 1605
2007 - schematic diagram pulse shaping

Abstract:
Text: . 16 1.2.2 SHUTTING OFF THE TRANSMITER , receive the bipolar line signal from the Remote E1 Terminal. 4 XRT59L921 TWENTY-ONE CHANNEL E1 , with RTIP_n to receive the bipolar line signal from the Remote E1 Terminal. V11 TxON I , - or twistedpair cable at the E1 data rate and 2. Be reliably received by the Remote Terminal , . 1.2.2 Shutting off the Transmiter The Transmit Driver for each Channel_n (within the XRT59L921


Original
PDF XRT59L921 XRT59L921 63-channel schematic diagram pulse shaping TG26-1205 PE-65835 TU12 XRT59L921IB
2007 - Not Available

Abstract:
Text: . 16 1.2.2 SHUTTING OFF THE TRANSMITER , with RRing_n to receive the bipolar line signal from the Remote E1 Terminal. 4 XRT59L921 REV , signal from the Remote E1 Terminal. I Transmit ON/OFF Input: Upon power up, all of the transmitters , Remote Terminal Equipment at the other end of the E1 data link. Comply with the ITU-T G.703 pulse , TPOS and TNEG, the transmitter will be powered down and tri-stated. 1.2.2 Shutting off the Transmiter


Original
PDF XRT59L921 XRT59L921 63-channel
2005 - Not Available

Abstract:
Text: . 15 1.2.2 SHUTTING OFF THE TRANSMITER , with RRing_n to receive the bipolar line signal from the Remote E1 Terminal. 4 xr REV. 1.1.0 , from the Remote E1 Terminal. I Transmit ON/OFF Input: Upon power up, all of the transmitters are , twistedpair cable at the E1 data rate and Be reliably received by the Remote Terminal Equipment at the other , transmitter will be powered down and tri-stated. 1.2.2 Shutting off the Transmiter The Transmit Driver for


Original
PDF XRT59L921 XRT59L921 63-channel
2009 - Not Available

Abstract:
Text: Remote Loop Back. 11 1 /, 0 7 1 + , # =0 =0 11 ,+ ,+- Local Loop Back , /; '=0( 11 - = >, REMOTE LOOP-BACK =0 11 /, / 0 7 3 1 + 1,1 0 75 1 , < TRANSMITER MONITOR OUTPUTS ! $ 0 < $ 4 Q $ ) % $ $ 4 D $ & $ Figure 9 , level trouble-shooting and testing, both local and remote loop-backs are possible with the built-in


Original
PDF XRT7296 XRT7296 28-pin 700mW. XRT7296IW-F SOJ28 XRT7296IW SOJ28 XRT7296IP-F PDIP28
2000 - TR-NWT-000499

Abstract:
Text: Remote Loop Back. 11 1 /, 0 7 1 + , # =0 =0 11 ,+ ,+- Local Loop Back , /; '=0( 11 - = >, REMOTE LOOP-BACK =0 11 /, / 0 7 3 1 + 1,1 0 75 1 , < TRANSMITER MONITOR OUTPUTS ! $ 0 < $ 4 Q $ ) % $ $ 4 D $ & $ Figure 9 , , both local and remote loop-backs are possible with the built-in loop-back circuit. The XRT7296 is


Original
PDF XRT7296 15-Nov-2010 XRT7296 TR-NWT-000499