The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
PIM300F6Z GE Critical Power PIM300X Series; ATCA Board Power Input Module, -38 to -75Vdc; 300W Input
PIM300AZ GE Critical Power PIM300X Series; ATCA Board Power Input Module, -38 to -75Vdc; 300W Input
PIM300A6Z GE Critical Power PIM300X Series; ATCA Board Power Input Module, -38 to -75Vdc; 300W Input
PIM300FZ GE Critical Power PIM300X Series; ATCA Board Power Input Module, -38 to -75Vdc; 300W Input
UPS12458 GE Critical Power CUST INTERFACE CARD-RELAY CARD
UPS18802 GE Critical Power OPTION CARD-USB, RS232 & RELAY

relay m300 Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
2002 - Leach relay M83536

Abstract: T412 RELAY m400 leach MIL-PRF-12883 SC402 Leach relay M400 MS27709 silicone R140 M400 relay 2SC4012
Text: SC 300 01 1-Basic socket snap lock designation_| | | 2-Mating relay ( M300 , M301, M302 , SC30*, SC40* ENGINEERING DATA SHEET SOCKET FOR 2 OR 4 POLE 10 AMP SNAP AND LOCK SOCKET SERIES DESIGNATION FOR: SERIES M300 , M301, M302, M400, M401, M402, T402, T412 DESIGNED TO THE STANDARDS AND , . Date of issue: 3/06 - 35 - Page 1 of 4 SOCKET DIMENSIONS RELAY GASKET SUPPLIED WITH RELAY , of issue: 3/06 - 36 - Page 2 of 4 SOCKET DIMENSIONS GASKET SUPPLIED WITH RELAY RELAY MTG


Original
PDF MIL-PRF-12883/41 M83536, M83726 MS27709 MIL-PRF-12883/40 M83536 MIL-P-46184 ZZ-R-765 MIL-G-45204 SC400 Leach relay M83536 T412 RELAY m400 leach MIL-PRF-12883 SC402 Leach relay M400 silicone R140 M400 relay 2SC4012
2002 - Leach relay M400 d4a

Abstract: M400 relay Leach relay M400 S400-A1B3 T412 relay silicone R140 MS27709
Text: SC 300 01 1-Basic socket snap lock designation_| | | 2-Mating relay ( M300 , M301, M302 , T412 ENGINEERING DATA SHEET TIME DELAY RELAY 2 PDT, 10 AMP Time delay relay on operate or on , FOR M400 RELAY FOR M402 RELAY CODE B S401 15.24 10.16 5.08 3 D 15.24 C 5.08 B A X1 2 X2 1 CODE , 26.3 15.9 28.2 ± 0.3 FOR M401 RELAY , FOR K COIL FOR M401 RELAY , FOR J COIL FOR HOLE , SERIES DESIGNATION FOR: SERIES M300 , M301, M302, M400, M401, M402, T402, T412 DESIGNED TO THE STANDARDS


Original
PDF 28Vdc SC400 SC401-1 SC401-2 SC402 Leach relay M400 d4a M400 relay Leach relay M400 S400-A1B3 T412 relay silicone R140 MS27709
2002 - M400D

Abstract: Leach Relay 0.5 amp 2 pdt LRE M300 MS27709 m400 leach T412 RELAY M402D MIL-C-39029 complete standard Leach relay M400 silicone R140
Text: T402 ENGINEERING DATA SHEET TIME DELAY RELAY 2 PDT, 2 AMP Time delay relay on operate or on , , TOLERANCE SEE CODE B FOR M400 RELAY FOR M402 RELAY CODE B S401 15.24 10.16 5.08 3 D 15.24 C 5.08 B A X1 , 10.16 X1 26.3 15.9 28.2 ± 0.3 FOR M401 RELAY , FOR K COIL FOR M401 RELAY , FOR J COIL , SERIES DESIGNATION FOR: SERIES M300 , M301, M302, M400, M401, M402, T402, T412 DESIGNED TO THE STANDARDS , choosing a component. Date of issue: 3/06 - 35 - Page 1 of 4 SOCKET DIMENSIONS RELAY GASKET


Original
PDF /30mV 28VdC 115Vac/60-400Hz SC400 SC401-1 SC401-2 SC402 M400D Leach Relay 0.5 amp 2 pdt LRE M300 MS27709 m400 leach T412 RELAY M402D MIL-C-39029 complete standard Leach relay M400 silicone R140
2002 - Leach relay M83536

Abstract: m400 leach Leach relay M83536 3 PDT M400 relay Leach relay M400 Leach relay M402 M402 relay Leach relay M400 d4a M400-D4A T412 RELAY
Text: SC 300 01 1-Basic socket snap lock designation_| | | 2-Mating relay ( M300 , M301, M302 , T402 ENGINEERING DATA SHEET TIME DELAY RELAY 2 PDT, 2 AMP Time delay relay on operate or on , S402 3 2 X2 Y1 1 POSITION, TOLERANCE SEE CODE B POSITION, TOLERANCE SEE CODE B FOR M400 RELAY FOR M402 RELAY CODE B S401 15.24 10.16 5.08 3 D 15.24 C 5.08 B A X1 2 X2 1 CODE C S401 MOUNTING , ± 0.3 FOR M401 RELAY , FOR K COIL FOR M401 RELAY , FOR J COIL FOR HOLE CLEARANCE, SEE


Original
PDF /30mV 28VdC 115Vac/60-400Hz SC400 SC401-1 SC401-2 SC402 Leach relay M83536 m400 leach Leach relay M83536 3 PDT M400 relay Leach relay M400 Leach relay M402 M402 relay Leach relay M400 d4a M400-D4A T412 RELAY
2002 - CECC16303-801

Abstract: Leach relay M83536 CECC16101-018 all zener diode colour code M300 relay M300 leach m2xx m300A silicone R140 M83536/S300-A6B3
Text: M300 ENGINEERING DATA SHEET HERMETICALLY SEALED RELAY 2 PDT/10 AMP Polarized, non latching hermetically sealed relay 2 PDT Contact arrangement Coil supply Meets the requirements of Qualified to Direct , POSITION, TOLERANCE SEE CODE B FOR M300 RELAY POSITION, TOLERANCE SEE CODE B FOR M302 RELAY CODE B , -Basic socket snap lock designation_| | | 2-Mating relay ( M300 , M301, M302, M400, M401 , or 115 Vac 400 Hz 40 grams max 26 x 25.7 x 13.3 Intrinsically safe relay . CONTACT ELECTRICAL


Original
PDF PDT/10 MIL-R-83536/9 CECC16101-018 CECC16303-801 SC400 SC401-1 SC401-2 SC402 CECC16303-801 Leach relay M83536 all zener diode colour code M300 relay M300 leach m2xx m300A silicone R140 M83536/S300-A6B3
all zener diode colour code

Abstract: S300-A1A2 MIL-S-12883 S300-A6B3 M300 relay Leach Relay S300-A9B9 S300-A8B9 CECC16101-018 FD300 diode
Text: M300 ENGINEERING DATA SHEET HERMETICALLY SEALED RELAY 2 PDT/10 AMP Polarized, non latching hermetically sealed relay 2 PDT Contact arrangement Coil supply Meets the requirements of Qualified to Direct , M300 RELAY POSITION, TOLERANCE SEE CODE B FOR M302 RELAY CODE B S301 15.24 10.16 5.08 3 5.08 B A , -Basic socket snap lock designation_| | | 2-Mating relay ( M300 , M301, M302, M400, M401 , or 115 Vac 400 Hz 40 grams max 26 x 25.7 x 13.3 Intrinsically safe relay . CONTACT ELECTRICAL


Original
PDF PDT/10 MIL-R-83536/9 CECC16101-018 CECC16303-801 SC400 SC401-1 SC401-2 SC402 all zener diode colour code S300-A1A2 MIL-S-12883 S300-A6B3 M300 relay Leach Relay S300-A9B9 S300-A8B9 FD300 diode
2002 - T412 RELAY

Abstract: T412 Leach relay M83536 M400 relay M402 leach Rx 2b relay silicone R140 relay studs a/T412 RELAY Leach relay M400
Text: T412 ENGINEERING DATA SHEET TIME DELAY RELAY 2 PDT, 10 AMP Time delay relay on operate or on , SEE CODE B POSITION, TOLERANCE SEE CODE B FOR M400 RELAY FOR M402 RELAY CODE B S401 15.24 10.16 , 2 X2 1 ± 0,3 ± 0,1 10.16 X1 26.3 15.9 28.2 ± 0.3 FOR M401 RELAY , FOR K COIL FOR M401 RELAY , FOR J COIL FOR HOLE CLEARANCE, SEE HARDWARE CODE MOUNTING HARDWARE CODE 1 , SERIES DESIGNATION FOR: SERIES M300 , M301, M302, M400, M401, M402, T402, T412 DESIGNED TO THE STANDARDS


Original
PDF 28Vdc SC400 SC401-1 SC401-2 SC402 T412 RELAY T412 Leach relay M83536 M400 relay M402 leach Rx 2b relay silicone R140 relay studs a/T412 RELAY Leach relay M400
2002 - s300a

Abstract: FD300 diode relay m300
Text: M300 ENGINEERING DATA SHEET HERMETICALLY SEALED RELAY 2 PDT/10 AMP Polarized, non latching hermetically sealed relay 2 PDT Contact arrangement Coil supply Meets the requirements of Qualified to Direct , POSITION, TOLERANCE SEE CODE B FOR M300 RELAY POSITION, TOLERANCE SEE CODE B FOR M302 RELAY CODE B , -Basic socket snap lock designation_| | | 2-Mating relay ( M300 , M301, M302, M400, M401 , 115 Vac 400 Hz 40 grams max 26 x 25.7 x 13.3 Intrinsically safe relay . CONTACT ELECTRICAL


Original
PDF PDT/10 MIL-R-83536/9 CECC16101-018 CECC16303-801 SC400 SC401-1 SC401-2 SC402 s300a FD300 diode relay m300
2002 - Relay M302 Reliability

Abstract: Leach relay M302 Leach relay M83536 3 PDT M302 leach M302 PCB relay m300 Leach relay M83536 Relay leach all zener diode colour code silicone R140
Text: SC 300 01 1-Basic socket snap lock designation_| | | 2-Mating relay ( M300 , M301, M302 , M302 ENGINEERING DATA SHEET RELAY - LATCH 2 PDT, 10 AMP Polarized, latching hermetically sealed relay 2 PDT Contact arrangement Meets the requirements of Coil supply MIL-R-83536/12 and /13 Direct , . Intrinsically safe relay . CONTACT ELECTRICAL CHARACTERISTICS Minimum operating cycles 100,000 cycles 20,000 , Application notes SUPPRESSOR DEVICES FOR RELAY COILS N°007 The inductive nature of relay coils allows


Original
PDF MIL-R-83536/12 SC400 SC401-1 SC401-2 SC402 Relay M302 Reliability Leach relay M302 Leach relay M83536 3 PDT M302 leach M302 PCB relay m300 Leach relay M83536 Relay leach all zener diode colour code silicone R140
2002 - Relay M302 Reliability

Abstract: Leach relay M302 M302 PCB Leach relay M83536
Text: M300 RELAY POSITION, TOLERANCE SEE CODE B FOR M302 RELAY CODE B S301 15.24 10.16 5.08 3 5.08 B A , SC 300 01 1-Basic socket snap lock designation_| | | 2-Mating relay ( M300 , M301, M302 , M302 ENGINEERING DATA SHEET RELAY - LATCH 2 PDT, 10 AMP Polarized, latching hermetically sealed relay 2 PDT Contact arrangement Meets the requirements of Coil supply MIL-R-83536/12 and /13 Direct , . Intrinsically safe relay . CONTACT ELECTRICAL CHARACTERISTICS Minimum operating cycles 100,000 cycles 20,000


Original
PDF MIL-R-83536/12 SC400 SC401-1 SC401-2 SC402 Relay M302 Reliability Leach relay M302 M302 PCB Leach relay M83536
2002 - Leach relay M83536 3 PDT

Abstract: leach relay 250
Text: 1 X1 Y1 X1 Y2 POSITION, TOLERANCE SEE CODE B FOR M300 RELAY POSITION, TOLERANCE SEE CODE , -Basic socket snap lock designation_| | | 2-Mating relay ( M300 , M301, M302, M400, M401 , M301 ENGINEERING DATA SHEET RELAY - NONLATCH 2 PDT, 10 AMP Non latching hermetically sealed relay , Vac 400 Hz 40 grams max 26 x 28.6 x 13.3 Intrinsically safe relay . CONTACT ELECTRICAL , Application notes SUPPRESSOR DEVICES FOR RELAY COILS N°007 The inductive nature of relay coils allows


Original
PDF MIL-R-83536/11 CECC16101-018 CECC16303-801 SC400 SC401-1 SC401-2 SC402 Leach relay M83536 3 PDT leach relay 250
2002 - all zener diode colour code

Abstract: Leach relay M83536 CECC16101-018 CECC16303-801 relay studs m300d LEACH switch FD300 diode leach relay series E M400 relay
Text: SHEET S300, S301, S302 RELAY SOCKET 10 AMP BASIC SOCKET SERIES DESIGNATION FOR: Series M300 , SC 300 01 1-Basic socket snap lock designation_| | | 2-Mating relay ( M300 , M301, M302 , M301 ENGINEERING DATA SHEET RELAY - NONLATCH 2 PDT, 10 AMP Non latching hermetically sealed relay , 400 Hz 40 grams max 26 x 28.6 x 13.3 Intrinsically safe relay . CONTACT ELECTRICAL , DEVICES FOR RELAY COILS N°007 The inductive nature of relay coils allows them to create magnetic


Original
PDF MIL-R-83536/11 CECC16101-018 CECC16303-801 SC400 SC401-1 SC401-2 SC402 all zener diode colour code Leach relay M83536 CECC16303-801 relay studs m300d LEACH switch FD300 diode leach relay series E M400 relay
2002 - s401 diode

Abstract: relay lre CECC16101-019 relay m400 all zener diode colour code m400 leach T402 S400-A1B3 M400 relay S4023
Text: M401 ENGINEERING DATA SHEET RELAY - NONLATCH 4 PDT, 10 AMP Non latching hermetically sealed relay , Intrinsically safe relay CONTACT ELECTRICAL CHARACTERISTICS Minimum operating cycles 100,000 cycles 20,000 , VOLTAGE Date of issue: 6/00 -3- Page 2 of 2 Application notes SUPPRESSOR DEVICES FOR RELAY COILS N°007 The inductive nature of relay coils allows them to create magnetic forces which are , current is switched off by another relay contact. The surge voltage is limited to -300V by the arc


Original
PDF MIL-R-6106 CECC16101-019 SC400 SC401-1 SC401-2 SC402 s401 diode relay lre CECC16101-019 relay m400 all zener diode colour code m400 leach T402 S400-A1B3 M400 relay S4023
2002 - M400 relay

Abstract: M402 M300 relay all zener diode colour code M402 leach M402 relay silicone R140
Text: M402 ENGINEERING DATA SHEET RELAY - LATCH 4 PDT, 10 AMP Polarized, latching hermetically sealed relay Contact arrangement 4 PDT Coil supply Direct current PRINCIPLE TECHNICAL CHARACTERISTICS , Vdc - 400 Hz 80 grams max 26 x 25.7 x 26 Intrinsically safe relay CONTACT ELECTRICAL , Application notes SUPPRESSOR DEVICES FOR RELAY COILS N°007 The inductive nature of relay coils allows , record shows the voltage across the coil when the current is switched off by another relay contact. The


Original
PDF SC400 SC401-1 SC401-2 SC402 M400 relay M402 M300 relay all zener diode colour code M402 leach M402 relay silicone R140
2002 - CECC16303-802

Abstract: m400 leach relay m400 M400B CECC16101-019 M400 relay Leach relay M400 M402 relay
Text: M400 ENGINEERING DATA SHEET RELAY - NONLATCH 4 PDT, 10 AMP Polarized, non latching hermetically sealed relay 4 PDT Contact arrangement Coil supply Meets the requirements of Qualified to Direct current , , corrosion protected metal can Intrinsically safe relay CONTACT ELECTRICAL CHARACTERISTICS Minimum , Application notes SUPPRESSOR DEVICES FOR RELAY COILS N°007 The inductive nature of relay coils allows , record shows the voltage across the coil when the current is switched off by another relay contact. The


Original
PDF M835636/15 CECC16101-019 CECC16303-802 Amps/28 115Vac 400Hz SC400 SC401-1 SC401-2 SC402 CECC16303-802 m400 leach relay m400 M400B M400 relay Leach relay M400 M402 relay
2002 - relay m402

Abstract: Leach relay M402 M400 relay Leach relay M83536 3 PDT
Text: _| | | 2-Mating relay ( M300 , M301, M302, M400, M401_| | 2-Hardware (0=less hardware, 1 , M402 ENGINEERING DATA SHEET RELAY - LATCH 4 PDT, 10 AMP Polarized, latching hermetically sealed relay Contact arrangement 4 PDT Coil supply Direct current PRINCIPLE TECHNICAL CHARACTERISTICS , 115 Vdc - 400 Hz 80 grams max 26 x 25.7 x 26 Intrinsically safe relay CONTACT ELECTRICAL , Application notes SUPPRESSOR DEVICES FOR RELAY COILS N°007 The inductive nature of relay coils allows


Original
PDF SC400 SC401-1 SC401-2 SC402 relay m402 Leach relay M402 M400 relay Leach relay M83536 3 PDT
2002 - MIL-R-6106

Abstract: M400 relay s401 diode Leach relay M83536
Text: _| | | 2-Mating relay ( M300 , M301, M302, M400, M401_| | 2-Hardware (0=less hardware, 1 , M401 ENGINEERING DATA SHEET RELAY - NONLATCH 4 PDT, 10 AMP Non latching hermetically sealed relay , Intrinsically safe relay CONTACT ELECTRICAL CHARACTERISTICS Minimum operating cycles 100,000 cycles 20,000 , VOLTAGE Date of issue: 6/00 -3- Page 2 of 2 Application notes SUPPRESSOR DEVICES FOR RELAY COILS N°007 The inductive nature of relay coils allows them to create magnetic forces which are


Original
PDF MIL-R-6106 CECC16101-019 SC400 SC401-1 SC401-2 SC402 M400 relay s401 diode Leach relay M83536
2002 - M400 relay

Abstract: m400 leach
Text: SC 300 01 1-Basic socket snap lock designation_| | | 2-Mating relay ( M300 , M301, M302 , M400 ENGINEERING DATA SHEET RELAY - NONLATCH 4 PDT, 10 AMP Polarized, non latching hermetically sealed relay 4 PDT Contact arrangement Coil supply Qualified to Direct current M835636/15 and /16 , protected metal can Intrinsically safe relay CONTACT ELECTRICAL CHARACTERISTICS Minimum operating cycles , : 6/00 -3- Page 2 of 2 Application notes SUPPRESSOR DEVICES FOR RELAY COILS N°007 The


Original
PDF M835636/15 CECC16101-019 CECC16303-802 Amps/28 115Vac 400Hz SC400 SC401-1 SC401-2 SC402 M400 relay m400 leach
2002 - Leach relay M400

Abstract: No abstract text available
Text: designation_| | | 2-Mating relay ( M300 , M301, M302, M400, M401_| | 2-Hardware (0 , M400 ENGINEERING DATA SHEET RELAY - NONLATCH 4 PDT, 10 AMP Polarized, non latching hermetically sealed relay 4 PDT Contact arrangement Coil supply Direct current Meets the requirements , Hermetically sealed, corrosion protected metal can Intrinsically safe relay APPLICABLE SOCKETS: S400 SC40 , DEVICES FOR RELAY COILS The inductive nature of relay coils allows them to create magnetic forces which


Original
PDF M835636/15 CECC16101-019 CECC16303-802 Amps/28 115Vac 400Hz SC402 SC401-2 SC401-1 SC400 Leach relay M400
2002 - Not Available

Abstract: No abstract text available
Text: designation_| | | 2-Mating relay ( M300 , M301, M302, M400, M401_| | 2-Hardware (0 , M402 ENGINEERING DATA SHEET RELAY - LATCH 4 PDT, 10 AMP Polarized, latching hermetically sealed relay 4 PDT Contact arrangement Meeting the Requirements of MIL – R – 6106/51 MIL â , sealed, corrosion protected metal can Intrinsically safe relay APPLICABLE SOCKET: S402 SC40 , SUPPRESSOR DEVICES FOR RELAY COILS The inductive nature of relay coils allows them to create magnetic


Original
PDF Amps/28 SC402 SC401-2 SC401-1 SC400
2010 - CECC16101-018

Abstract: CECC16303-801
Text: M300 ENGINEERING DATA SHEET HERMETICALLY SEALED RELAY 2 PDT/10 AMP Polarized, non latching hermetically sealed relay 2 PDT Contact arrangement Coil supply Meets the requirements of Qualified to Direct , or 115 Vac 400 Hz 40 grams max 26 x 25.7 x 13.3 Intrinsically safe relay . CONTACT ELECTRICAL , N/A M300 V 110 125 75 5 5000 N/A GENERAL CHARACTERISTICS Temperature range Dielectric , Date of issue: 9/07 - 102 - Page 2 of 4 MOUNTING STYLES 2 Ø5 M300 A 25.7 MAX B


Original
PDF PDT/10 MIL-R-83536/9 CECC16101-018 CECC16303-801 SF300. CECC16303-801 28Vdc:
RELAIS LEACH

Abstract: CECC16101-018 Leach International M300
Text: F/ M300 RELAIS HERMETIQUE 2 RT /10 A HERMETICALLY SEALED RELAY 2 P D T /10 AMPS J - Relais hermétique monostable polarisé Polarized, non latching hermetically sealed relay - Combinaison , Intrinsically safe relay CARACTERISTIQUES ELECTRIQUES DES CONTACTS C ontacts electrical characteristics Durà , Fax : 03 87 97 84 04 Date d'édition : 01/12/98 Page 1 /4 10 8 4 2 y F/ M300 , ©dition : 01/12/98 F/ M300 T ypes de sorties T erm inal0.05 types + 0 1 5 7 - 0.03 01.57


OCR Scan
PDF F/M300 MIL-R-6106 CECC16101-018 CECC16303-801 RELAIS LEACH CECC16101-018 Leach International M300
2002 - M300 relay

Abstract: S301-B1A2 M300 leach MIL-S-12883 Leach relay socket S300-A1B3 S300A1A2 M300-D4A FLR300 S30-1
Text: 1 X1 Y1 X1 Y2 POSITION, TOLERANCE SEE CODE B FOR M300 RELAY POSITION, TOLERANCE SEE CODE B FOR M302 RELAY CODE B S301 15.24 10.16 5.08 3 5.08 B A X1 12.68 DEPTH 9 MM 2 X2 1 DETAIL 0.9 , S300, S301, S302 ENGINEERING DATA SHEET RELAY SOCKET 10 AMP BASIC SOCKET SERIES DESIGNATION FOR: Series M300 (DC Coil), M301 (DC Coil), M302 (DC Coil), FD300, FLS300, FLR300 GENERAL CHARACTERISTICS , 2 B A X1 28.2 ± 0.3 14.1± 3 2 X2 1 FOR M301 RELAY , FOR K COIL FOR M301 RELAY


Original
PDF FD300, FLS300, FLR300 M300-D4A 301-D4F/-K 301-D4E/-J MIL-S-12883/41B S300-A8A8 S300-A8B9 S301-B8A8 M300 relay S301-B1A2 M300 leach MIL-S-12883 Leach relay socket S300-A1B3 S300A1A2 FLR300 S30-1
2002 - M300 relay

Abstract: S301-C8A8
Text: SHEET RELAY SOCKET 10 AMP BASIC SOCKET SERIES DESIGNATION FOR: Series M300 (DC Coil), M301 (DC Coil , POSITION, TOLERANCE SEE CODE B FOR M300 RELAY POSITION, TOLERANCE SEE CODE B FOR M302 RELAY CODE B , FLS300 ENGINEERING DATA SHEET TIME DELAY RELAY 1PST (SSO) Time delay relay (on operate, on release or repeat cycle timer) Fixed or adjustable timing delay Contact arrangement Power supply 1 solid , ± 3 2 X2 1 FOR M301 RELAY , FOR K COIL FOR M301 RELAY , FOR J COIL FOR HOLE CLEARANCE


Original
PDF FLS300 25mAmps FLS300 M300-D4A 301-D4F/-K 301-D4E/-J MIL-S-12883/41B S300-A8A8 S300-A8B9 S301-B8A8 M300 relay S301-C8A8
2002 - FLS300

Abstract: relay studs m300d relay socket studs M300 relay Leach relay M302 leach relay
Text: FLS300 ENGINEERING DATA SHEET TIME DELAY RELAY 1PST (SSO) Time delay relay (on operate, on , DATA SHEET S300, S301, S302 RELAY SOCKET 10 AMP BASIC SOCKET SERIES DESIGNATION FOR: Series M300 (DC Coil), M301 (DC Coil), M302 (DC Coil), FD300, FLS300, FLR300 2.35 ± 2.8 ± SEE MOUNTING , 2 X2 1 B A 3 2 X2 1 X1 Y1 X1 Y2 POSITION, TOLERANCE SEE CODE B FOR M300 RELAY POSITION, TOLERANCE SEE CODE B FOR M302 RELAY CODE B S301 15.24 10.16 5.08 3 5.08 B A X1


Original
PDF FLS300 25mAmps FLS300 M300-D4A 301-D4F/-K 301-D4E/-J MIL-S-12883/41B S300-A8A8 S300-A8B9 S301-B8A8 relay studs m300d relay socket studs M300 relay Leach relay M302 leach relay
Supplyframe Tracking Pixel