The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
LF198AJ8 Linear Technology IC SAMPLE AND HOLD AMPLIFIER, CDIP8, Sample and Hold Circuit
LF198AN8 Linear Technology IC SAMPLE AND HOLD AMPLIFIER, PDIP8, Sample and Hold Circuit
LF198S Linear Technology IC SAMPLE AND HOLD AMPLIFIER, PDSO, Sample and Hold Circuit
LF198AS Linear Technology IC SAMPLE AND HOLD AMPLIFIER, PDSO, Sample and Hold Circuit
LF198N8 Linear Technology IC SAMPLE AND HOLD AMPLIFIER, PDIP8, Sample and Hold Circuit
LF198J8 Linear Technology IC SAMPLE AND HOLD AMPLIFIER, CDIP8, Sample and Hold Circuit

relay SUN-HOLD RAS 0510 Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
siemens 3RP1505-1BP30

Abstract: siemens 3RP1540-1BN30 3RP1574-1NP30 3RP1560 3RP1555-1AP30 3RP1505-1BP30 3RP1560-1SP30 3RP1540-1BB30 siemens sirius 3rp1574-1nq30 3RP1505-1AW30
Text: Time Relay Energized Contact Closed Illustration Contact Open Version Time Setting Range t , No Price $ 3RP1000, multi-function time relay , 8 time ranges with LED 1 SPDT contact, 7 functions 3RP1000-2AP30 The time relay 3RP1000 can be set for different functions by means of coding plugs. The required coding plugs are supplied with the relay . For functions, see coding plugs 7PX9904 0.05­1 s 0.5­10 s 0.05­1 min 5­100 s 0.5­10 min 0.05­1 h 5­100 min 0.5­10 h 24


Original
PDF 50/60Hz 3RP1000, 3RP1000-2AP3 siemens 3RP1505-1BP30 siemens 3RP1540-1BN30 3RP1574-1NP30 3RP1560 3RP1555-1AP30 3RP1505-1BP30 3RP1560-1SP30 3RP1540-1BB30 siemens sirius 3rp1574-1nq30 3RP1505-1AW30
2010 - Not Available

Abstract: No abstract text available
Text: -8600 SERIES (GFR4001-IM) Insulation Monitor SUPPLEMENTAL MONITORING Description The PGM-8600 relay , analog output for predictive maintenance. The relay can operate on 1 or 3-phase grounded, resistance grounded or ungrounded systems up to 6 kV. When the power system is de-energized, the relay monitors the , . When the power system is energized in ungrounded systems, the relay continues to monitor the insulation. In grounded systems, the relay switches off to prevent nuisance tripping. The mode of operation


Original
PDF PGM-8600 GFR4001-IM) PGM-8600 PGA-0510 com/pgm-8600
LRD 07

Abstract: LR2 D* thermal overload relay LRD-08 overload relay LRD 03 LRD 3355 lrd16 LRD1516 LRD-08 thermal overload relay LRD 10 lrd -08
Text: automatic reset, b with relay trip indicator, b for a.c. or d.c. Relay setting range (A) Fuses to be used with selected relay aM (A) gG (A) BS88 (A) For use with contactor LC1 Reference , 0.124 0.124 0.124 0.124 0.124 0.124 0.124 0.124 0.124 0.124 0.124 0.510 0.510 0.510 0.510 0.510 0.510 0.510 0.510 0.900 0.900 0.900 1.000 1.000 1.000 Class 10 A (1) with spring , 0.140 0.140 0.140 0.140 Class 10 A (1) with connection by lug-clamps Select overload relay with


Original
PDF 24514-EN LRD 07 LR2 D* thermal overload relay LRD-08 overload relay LRD 03 LRD 3355 lrd16 LRD1516 LRD-08 thermal overload relay LRD 10 lrd -08
2010 - Not Available

Abstract: No abstract text available
Text: -8600 Series (GFR4001-IM) Insulation Monitor SUPPLEMENTAL MONITORING Description The PGM-8600 relay , analog output for predictive maintenance. The relay can operate on 1 or 3-phase grounded, resistance grounded or ungrounded systems up to 6 kV. When the power system is de-energized, the relay monitors the , . When the power system is energized in ungrounded systems, the relay continues to monitor the insulation. In grounded systems, the relay switches off to prevent nuisance tripping. The mode of operation


Original
PDF PGM-8600 GFR4001-IM) PGM-8600 PGA-0510 com/pgm-8600
SAIA-Burgess KOP160J7MWVPN00

Abstract: KOP160J7MWVPN00 KOP560K7MWVPN00 KOP560 KOP512K7MWVPN00 KOP511K7MWVPN00 KOP170J7MWVPN00 kop 142 KOP112J7MWVPN00 vde 0435 timer
Text: , 24, 28, 31, 32, 33, 34, 41, 42, 51 Time ranges 12 time ranges, 0.05 s up to 60 h Outputs 1 relay as , ; 22: fleeting-off delay timer; 23: impulse converter; 24: impulse generator; 42: flasher relay ; 28 , 0.05.1 h 0.15.3 s 0.15.3 min 0.15.3 h 0.5.10 s 0.5.10 min 0.5.10 h 1.5.30 s , range, current 1 mA, duration of the control pulse >50 ms (AC), >30 ms (DC), pause >55 ms (DC) 1 relay , delay timer (121) Flasher relay starting with pulse (142) Delayed operation with pulse control


Original
PDF B-1800 F-92230 D-58553 D-63303 CJ260 SAIA-Burgess KOP160J7MWVPN00 KOP160J7MWVPN00 KOP560K7MWVPN00 KOP560 KOP512K7MWVPN00 KOP511K7MWVPN00 KOP170J7MWVPN00 kop 142 KOP112J7MWVPN00 vde 0435 timer
KOL112H7MNVMN00

Abstract: KOL111H7MNVMN00 KOL121H7MNVMN00 KOL142H7MNVMN00 KOL312H7MRVPN00 KOL360H7MRVPN00 KOL160H7MNVMN00 KOL311H7MRVPN00 KOL342H7MRVPN00 KOL360
Text: Repeat accuracy Monitoring relays Setting accuracy 4 KOL 160/ 112 0.5.10 s, 3.60 s, 0.5.10 min, 3.60 min KOL 311, 312, 321, 342, 360 0.05.1 s, 0.5.10 s, 0.05.1 min, 0.5.10 min, 0.05.1 h, 0.5.10 h Time range can be easily selected on the front of the relay , using a screwdriver ± , relay KOL 3 · · · · 0.15 s.10 min · · · · Operating voltage Number of , Controls Function settings (only with KOL 160/360) Here you can set the relay function, e.g., 11 -


Original
PDF KOL360, KOL251H7MKVn KOL112H7MNVMN00 KOL111H7MNVMN00 KOL121H7MNVMN00 KOL142H7MNVMN00 KOL312H7MRVPN00 KOL360H7MRVPN00 KOL160H7MNVMN00 KOL311H7MRVPN00 KOL342H7MRVPN00 KOL360
2012 - ground detector relay

Abstract: No abstract text available
Text: integrity of ungrounded electrical systems. The relay monitors the insulation for damage and assists with , auxiliary contacts to toggle the relay off when the contactor or breaker is closed. Simplified Circuit , connecting to an optional meter (PGA- 0510 ) or control system Flexible options for ease of installation , Coupler A PGH Series high-tension coupler is required for systems between 1,300 V and 6,000 V. PGA- 0510 Analog Ohm Meter Optional PGA- 0510 Analog Meter allows for metering of insulation resistance. Ordering


Original
PDF PGR-3200 PGA-0510 com/pgr-3200 ground detector relay
2013 - Not Available

Abstract: No abstract text available
Text: insulation integrity of ungrounded electrical systems. The relay monitors the insulation for damage and , breaker or contactor auxiliary contacts to toggle the relay off when the contactor or breaker is closed , © Provides means for connecting to an optional meter (PGA- 0510 ) or control system Flexible options for ease , coupler is required for systems between 1,300 V and 6,000 V. PGA- 0510 Analog Ohm Meter Optional PGA- 0510 , requirement PGH Series Required >1,300 V PGA- 0510 Optional Note: For optional conformal coating


Original
PDF PGR-3200 com/pgr-3200
2012 - Not Available

Abstract: No abstract text available
Text: the insulation integrity of ungrounded electrical systems. The relay monitors the insulation for , circuit breaker or contactor auxiliary contacts to toggle the relay off when the contactor or breaker is , insulation resistance is below 10 kΩ Provides means for connecting to an optional meter (PGA- 0510 ) or , Series high-tension coupler is required for systems between 1,300 V and 6,000 V. PGA- 0510 Analog Ohm Meter Optional PGA- 0510 Analog Meter allows for metering of insulation resistance. Ordering


Original
PDF PGR-3200 PGA-0510 com/pgr-3200
1998 - star delta wiring diagram motor start y

Abstract: 700-FEM3TU23 700-FEB1SU22 FED3T 700-FED1SU22 700-FEY2QU23 700-FEB3TU23 vde 0435 timer star delta wiring diagram 700-FEM
Text: Position Supply Voltages Fifth Position Time Ranges Second Position Type of Relay Fourth Position , ) starting with pulse Multi-time setting ranges 0.5 s.60 m (10s) 0.5.10 s (60s) 3.60 s (10m) 0.5.10 min (60m) 3.60 m 0.4 0.6 0.8 Multi-time setting ranges 0.05 s.10 h (1s) 0.05.1 s (10s) 0.5.10 s (1m) 0.05.1 min (10m) 0.5.10 min (1h) 0.05.1 h (10h) 0.5.10 h , ) 0.5.10 s (1m) 0.05.1 m (10m) 0.5.10 m (1h) 0.05.1 h (10h) 0.5.10 h 0.8 0.2 1.0


Original
PDF
KOL360

Abstract: KOL311 vde 0435 timer KOL312 FLASHER RELAY KOL342 KOL321 IEC1000-4-5
Text: two terminals, 6 time ranges and relay as changeover Function and connection diagrams Technical data Multi-time ranges 0.05.1 s, 0.5.10 s, 0.05.1 min, 0.5.10 min, 0.05.1 h, 0.5.10 h , the control pulse 250 ms Output 1 relay as changeover, LED display of output status , Flasher relay (42) 0.5 W at 24 VDC, 5 VA at 240 VAC Duty cycle Fleeting-on delay timer (21 , , fleeting-on delay timer KOL342, flasher relay KOL311 H7 MRVP N00 KOL312 H7 MRVP N00 KOL321 H7 MRVP N00


Original
PDF KOL311, KOL312, KOL321, KOL342, KOL311 KOL312 KOL321 KOL342 KOL360, KOL360 vde 0435 timer FLASHER RELAY IEC1000-4-5
relay 8 pin wiring diagram

Abstract: w 6556 a 24 Vdc relay 8 pin wiring diagram 208-480V Macromatic 3 phase monitor pin diagram of 8 pin relay 70169-D 3-phase monitor AUTOMATIC PHASE SELECTOR
Text: drop-out setting for a period longer than the adjustable time delay of 0.5-10 seconds, the relay , Voltages Standard 8-Pin Octal Socket Mounting LED Indicates Relay Status Adjustable 0.5-10 Seconds Time , . 70175104 70175173 70175133 70175134 Mfr.'s Type PCP2 PAP208 PAP240 PAP480 ARP Series - Alternating Relay , is opened, the output relay contacts will change state, thus alternating the two loads. Features , Indicate Relay Status Stock No. 70175247 70175248 70175249 70175250 US ENCLOSURES Specifications: SPDT


Original
PDF PAP208 PAP240 PAP480 VAC/30 70169-D, relay 8 pin wiring diagram w 6556 a 24 Vdc relay 8 pin wiring diagram 208-480V Macromatic 3 phase monitor pin diagram of 8 pin relay 70169-D 3-phase monitor AUTOMATIC PHASE SELECTOR
tag 8610

Abstract: 090.00.2 ma 8620 relays 095.01 8610
Text: 86 Series - Timer modules Features 86.00 Timer modules for use in conjunction with relay & , 26.9 90.03 + 60.13 + 86.00 33.5 relay +socket relay +socket A2 38 A2 A1 B1 , (0.05.1)s, ( 0.5.10 )s, (5.100)s, ( 0.5.10 )min, (5.100)min, ( 0.5.10 )h, (5.100)h Specified time , conjunction with relay & socket. 86.10 - ON delay timer module 86.20 - ON pulse timer module · Timer , pulse relay +socket relay +socket = 35.4 AI: ON delay 32 95.05 + 40.52 + 86.10


Original
PDF
KOL312H7MRVPN00

Abstract: KOL360H7MRVPN00 vde 0435 timer KOL311H7MRVPN00 FLASHER RELAY timer vde 0435 KOL251H7MKVPN00 KOL321H7MRVPN00 KOL342H7MRVPN00 KOL251
Text: h Outputs 1 relay NO, KOL1. 1 relay as change-over, KOL3. 250 VAC, 5 A Supply voltage , release timer KOL321H7MRVPN00 Fleeting-on delay timer KOL342H7MRVPN00 Flasher relay timer , generator; 42: flasher relay ; 28: watchdog; 31/70: asymmetrical timer; 51: star-delta timer; 19: power off , Mounting saia-burgess Control Devices 0.05.1 s 0.05.1 min 0.05.1 h 0.5.10 s 0.5.10 min 0.5.10 h time range and function selected from front with screwdriver ±5% of the time range final value


Original
PDF KOL360H7MRVPN00 KOL311H7MRVPN00 KOL312H7MRVPN00 KOL321H7MRVPN00 KOL251 CJ260 KOL312H7MRVPN00 KOL360H7MRVPN00 vde 0435 timer KOL311H7MRVPN00 FLASHER RELAY timer vde 0435 KOL251H7MKVPN00 KOL321H7MRVPN00 KOL342H7MRVPN00
2009 - Not Available

Abstract: No abstract text available
Text: -3200 continuously monitors the insulation integrity of ungrounded electrical systems for ground faults. The relay , power system is de-energized, the relay monitors the insulation for damage, providing predictive maintenance and troubleshooting for developing ground faults. When the power system is energized, the relay , units operate on ungrounded systems up to 6 kV, 1-phase or 3-phase, 50 or 60 Hz. The relay can be , coupler (PGH) connected between the phase conductor and the relay . Features/Benefits PHASE CONDUCTOR


Original
PDF PGR-3200 PGA-0510 com/series/PGR-3200
2009 - Not Available

Abstract: No abstract text available
Text: -3200 continuously monitors the insulation integrity of ungrounded electrical systems for ground faults. The relay , power system is de-energized, the relay monitors the insulation for damage, providing predictive maintenance and troubleshooting for developing ground faults. When the power system is energized, the relay , units operate on ungrounded systems up to 6 kV, 1-phase or 3-phase, 50 or 60 Hz. The relay can be , coupler (PGH) connected between the phase conductor and the relay . Features/Benefits PHASE


Original
PDF PGR-3200 ungro-0510 com/series/PGR-3200
schneider LRD 08

Abstract: LRD schneider relay LC1-D65 LC1-D50 Schneider Electric LRD 06 LR9-D5369 LC1-D09 schneider overload relay schneider LC1-D09 LRD-21
Text: simulation of relay tripping (actuates both the N/O and N/C contacts). 3 Stop button. Actuates the N/C , characteristics of power circuit Relay type LRD01 to 16 LR2D15pp LR3D01 to D16 LRD21 to 35 , characteristics of power circuit Relay type LR9-D Tripping class Conforming to UL 508, EN 60947-4-1 , . Class 10 A tripping p Compensated relays with manual or automatic reset, p with relay trip indicator, p for a.c. or d.c. Relay Fuses to be used with selected relay setting range aM gG BS88 A A


Original
PDF LRD-01. LRD-3322. LR9-D67 LR9-D69 schneider LRD 08 LRD schneider relay LC1-D65 LC1-D50 Schneider Electric LRD 06 LR9-D5369 LC1-D09 schneider overload relay schneider LC1-D09 LRD-21
2004 - relay SUN-HOLD RAS 0510

Abstract: relay 5v RAS-0510 relay RAS 0510 ras-0510 sun hold ras-0510 relay RAS 0510 RAS 0510 relay ras-0510 relay of RAS 0510 relay RAS 0510 SUN HOLD
Text: . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2.3.8 J7 - Relay Connector . . . . . . . , . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1.10 Relay Circuit. . . . . . . . . . . , . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 5.4.7 Relay . . , . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 5.4.7.2 Relay Driver , any RF module. It provides Tango3/Romeo2, keypad, LCD, relay , TRIAC, buzzer, LED software drivers


Original
PDF M68HC08 DRM068 relay SUN-HOLD RAS 0510 relay 5v RAS-0510 relay RAS 0510 ras-0510 sun hold ras-0510 relay RAS 0510 RAS 0510 relay ras-0510 relay of RAS 0510 relay RAS 0510 SUN HOLD
2011 - GROUND Fault MONITORING CIRCUIT

Abstract: PGC5000 PGC-5000 insulation monitoring device TRANSFORMER 6100 insulation monitoring device motor PGA-0500
Text: Motor Ground-Fault & Insulation Relay Description The PGR-6100 combines the features of a ground-fault motor-protection relay and insulation monitor into one unit. It protects against ground faults, both when the , L1 PGA-0500 Analog % Current Meter PGA- 0510 Analog Ohm Meter Optional panel-mounted meters , Ground Fault & Insulation Relay ) L2 C D Ordering Information Catalog/System Number , Hz, 5 VA accessories requirement Required Required >1300 V Optional 47 PGA- 0510


Original
PDF PGR-6100 PGC-5000 PGR-3200. 50G/N, 51G/N) com/pgr-6100 GROUND Fault MONITORING CIRCUIT PGC5000 insulation monitoring device TRANSFORMER 6100 insulation monitoring device motor PGA-0500
2012 - PGC5000

Abstract: No abstract text available
Text: Ground-Fault & Insulation Relay Description The PGR-6100 combines the features of a ground-fault protection relay and insulation monitor into one unit. It protects against ground faults by monitoring insulation , undervoltage breaker coil Accessories PGR-6100 SERIES L1 L2 (Motor Ground-Fault & Insulation Relay , -0500 Analog % Current Meter PGA- 0510 Analog Ohm Meter Optional panel-mounted meters display ground-fault , -6100-120 PGR-6100-240 accessories 120 Vac 240 Vac requirement PGC-5000 Series PGH Family PGA-0500 PGA- 0510


Original
PDF PGR-6100 GFR4000) 50G/N, 51G/N) GFR4000 PGR-6100, com/pgr-6100 PGC5000
Telemecanique lc1 f185

Abstract: telemecanique star delta starter Telemecanique RE8 time delay relays star delta wiring diagram RE7-MY13MW RE7 TL11BU RE7-ML11BU star delta wiring diagram with timer RE7MY13BU zelio re7 relay
Text: circuit Control circuit voltage, depending on model Type Pages 2/2 Te Relay outputs , single timing range 7 10 1 0.05.1 s 0.15.3 s 0.5.10 s 1.5.30 s 5.100 s 15.300 s 1.5.10 min 0.05.1 s 0.15.3 s 0.5.10 s 1.5.30 s 5.100 s 15.300 s 1.5 , Timing starts when the relay is energised. When the set time delay (t) has elapsed, the output contact closes. When the relay is de-energised, the contact returns to its initial position. The output contact


Original
PDF RE7-RA11BU Telemecanique lc1 f185 telemecanique star delta starter Telemecanique RE8 time delay relays star delta wiring diagram RE7-MY13MW RE7 TL11BU RE7-ML11BU star delta wiring diagram with timer RE7MY13BU zelio re7 relay
2012 - Not Available

Abstract: No abstract text available
Text: Ground-Fault & Insulation Relay Description The PGR-6100 combines the features of a ground-fault protection relay and insulation monitor into one unit. It protects against ground faults by monitoring insulation , PGA-0500 Analog % Current Meter PGA- 0510 Analog Ohm Meter Optional panel-mounted meters display , Insulation Relay ) L1 L2 C D Ordering Information ORDERING NUMBER CONTROL POWER PGR , Required >1300 V PGA-0500 Optional PGA- 0510 Optional Note: For optional conformal coating


Original
PDF PGR-6100 GFR4000) PGA-0510 com/pgr-6100 50G/N, 51G/N) GFR4000 PGR-6100,
KOP160J7MWVPN00

Abstract: SAIA-Burgess KOP160J7MWVPN00 KOP160J7MWVAN00 SAIA-Burgess KOP160J7MWVAN00 KOP112J7MWVPN00 KOP170J7MWVPN00 KOP111J7MWVPN00 kop 160 FLASHER RELAY 2 led flasher
Text: 0.05.1 s, 0.15.3 s, 0.5.10 s 0.05.1 min, 0.15.3 min, 0.5.10 min 0.05.1 h, 0.15.3 h, 0.5.10 h, 3.60 h Time range can be easily selected on the front of the relay , using a screwdriver ± 5 , Fleeting-off delay timer Pulse converter Pulse generator Flasher relay with pulse starting 1 changeover , the relay function, e.g.: 11 - delayed operation 8 Contact addresses Fine setting T1 fine , timer (21) Monitoring relays LED Flasher relay with pulse starting (12) U U Output


Original
PDF KOP160J7MWVPN00 KOP160J7MWVAN00 KOP112J7MWVPN00 KOP111J7MWVPN00 KOP160J7MWVPN00 SAIA-Burgess KOP160J7MWVPN00 KOP160J7MWVAN00 SAIA-Burgess KOP160J7MWVAN00 KOP112J7MWVPN00 KOP170J7MWVPN00 KOP111J7MWVPN00 kop 160 FLASHER RELAY 2 led flasher
KOP560K7MWVPN00

Abstract: KOP511K7MWVPN00 KOP512K7MWVPN00 KOP560 KOP119K7MWVPN00 KOP560K FLASHER RELAY KOP219K KOP512 vde 0435 timer
Text: : impulse converter; 24: impulse generator; 42: flasher relay ; 28: watchdog; 31/70: asymmetrical timer; 51 , 0.05.1 s 0.15.3 s 0.5.10 s 0.05.1 min 0.15.3 min 0.5.10 min 0.05.1 h 0.15.3 h 0.5.10 h 3.60 h (time range and function selected from front with screwdriver) ±5% of the time range , release (16) Impulse generator (24) Fleeting-on delay timer (21) Flasher relay starting with , delay timer 12 screw mounting 0.05.1 s 0.15.3 s 0.5.10 s GA HA KA 0.05.1 min


Original
PDF KOP511K7MWVPN00 KOP512K7MWVPN00 KOP560K7MWVPN00 CJ260 KOP560K7MWVPN00 KOP511K7MWVPN00 KOP512K7MWVPN00 KOP560 KOP119K7MWVPN00 KOP560K FLASHER RELAY KOP219K KOP512 vde 0435 timer
tag 8630

Abstract: 094.71 ma 8630 8630 090.00.2 A14U n4232
Text: relay & socket. 86.00 - Multi-function & multi-voltage timer module 86.30 - Bi-function & , ,5 6,3 Relay + socket Relay + socket A2 15.5 Relay + socket A2 A2 A1 B1 A1 , , ( 0.5.10 )s, (5.100)s, ( 0.5.10 )min, (5.100)min, ( 0.5.10 )h, (5.100)h Specified time range % , , 56, 60 and 62 series relays Poles for chosen relay /socket combination according to chart below Combinations 0 Number of poles 1 1 1 2 2 Relay type 40.31 40.61 46.61 40.52/44.52/44.62


Original
PDF
Supplyframe Tracking Pixel