The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
UPS12458 GE Critical Power CUST INTERFACE CARD-RELAY CARD
UPS18802 GE Critical Power OPTION CARD-USB, RS232 & RELAY
7604501EA Texas Instruments BCD-to-Seven-Segment Decoders/Drivers 16-CDIP -55 to 125
7604501FA Texas Instruments LS SERIES, SEVEN SEGMENT DECODER/DRIVER, INVERTED OUTPUT, CDFP16, DFP-16
84045012A Texas Instruments Quadruple 2-Input Positive-OR Gates 20-LCCC -55 to 125
5962-8404501VCA Texas Instruments Quadruple 2-Input Positive-OR Gates 14-CDIP -55 to 125

relay Re 04501 Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
relay 04501

Abstract:
Text: : Solenoid Driver Lamp Driver Relay Substitute Switching Regulator » Inverter/Converter - 9ZCS-39969 , °C Operating and Storage Junction Temperature Range SYMBOL VcEO VCES Vebo ·c Pd Tj , Tst G 04501 ,2


OCR Scan
PDF 9ZCS-39969 O-220AB D45D-series D45D5 125ec D45D2 relay 04501 04501 relay
2000 - FIN-00330

Abstract:
Text: controlled server to other sensors/ controllers server mains cord slave relay unit reset controller temperature/ humidity sensor Linet network (2 wire) master relay unit to telephone line , basis of the system is the master relay unit, which allows turning off/on up to 7 separate devices via a modem or direct serial connection. The system can be upgraded with slave relay units, reset , /O-points. Master and slave relay units reserve 7 I/O-points each, reset switch controllers and sensors


Original
PDF FIN-00330 84x84x40mm "Humidity Sensor" 8205 datasheet belden rj45 connector Belden Wire linet
RELZ100

Abstract:
Text: RN -fault (RF = primary a) Relay A RF UR US OT m IS IT IN £2 Re KV Im Re W Do Re KV Im Re , •Calculation of relay characteristic •Plotting facilities • Input of disturbance recorder values Application RCALC is a relay calculation program and is used to check the reach of a distance relay , the relay measurement is not correct. The relay in the exporting end of line will overreach and the relay in the importing end of line will underreach. With help of this program it is possible to see how


OCR Scan
PDF 1MDB06023-EN 006-AA 006-BA 006-CA RELZ100 RK601 006-DA 640KB A33A ka 75000 MVA generator
telemecanique contactor catalogue

Abstract:
Text: . . . . . . . . . . . . . . . . . . . . . page 21 Modular relays, relay output, width 17.5 mm b , Industrial single or multifunction relays, relay output, width 22.5 mm b Characteristics. . . . . . . . . . , relays, optimum, relay output, width 22.5 mm b Characteristics. . . . . . . . . . . . . . . . . . . . . , , schemes . . . . . . . . . . . . . . . . pages 38 to 41 Miniature plug-in relays, relay output b , 43 Electronic relays, relay output, 48 x 48 housing b Presentation . . . . . . . . . . . . . . .


Original
PDF DIA3ED2051205EN telemecanique contactor catalogue schneider RM 26 overload relay WIRING DIAGRAM RE7 TL11BU schneider star delta timer RE48A telemecanique star delta starter table telemecanique limit switch catalogue RE11RMMW off delay timer telemecanique Schneider contactor catalogue
RXMK1

Abstract:
Text: certain faults are required to be remotely indicated an auxiliary relay RE is used; this is connected as , relay SR has picked up, that is after 4—5 s. One RE can remotely transmit two signals. The signal from , relay RXMK 1 NV 2 See table page 11 and Cat. RK 21- -10 E Auxiliary relay RXMM 1 GL, RE See table page , alarm relay GL and in the other as an individual remote signal relay RE . The relay Incorporates two , 'Complete systems' below. / Unit One-seat relay / Module / Fig. 2. Arrangement ■SR-, -GL -AL -SI Fig. 4


OCR Scan
PDF S-721 RXMK1 RXMM 1 RXSF1 ABB Relays COMBIFLEX tools 063-AS ABB TOOLS COMBIFLEX rxsf-1 RXTNT 11 rxma1 002-AN
Not Available

Abstract:
Text: Input Impedance, Network Balance Impedance and gains Three relay drivers Line state detection outputs , line usually via an external protection circuit. 3 XLA Loop Relay Contact A. Connects to XLB through relay contacts (K1 A) when the relay is energized. 4 XLB Loop Relay Contact B. Connects to XLA through relay contacts (K1 A) when the relay is energized. 5 XLC Loop Relay Contact C. Connects to XLD through relay contacts (K1B) when the relay is energized. 6 XLD Loop


OCR Scan
PDF MH88632B MH88632BT MH88632B
Tip & Ring Tin/Lead Termination “B”

Abstract:
Text: Programmable Input Impedance, Network Balance Impedance and gains Three relay drivers Line state detection , line usually via an external protection circuit. Loop Relay Contact A. Connects to XLB through relay contacts (K1 A) when the relay is energized. Loop Relay Contact B. Connects to XLA through relay contacts (K1 A) when the relay is energized. Loop Relay Contact C. Connects to XLD through relay contacts (K1B) when the relay is energized. Loop Relay Contact D. Connects to XLC through relay contacts (K1B) when


OCR Scan
PDF MH88632B MH88632B MH88632BT Tip & Ring Tin/Lead Termination “B”
Not Available

Abstract:
Text: €¢ T hree relay drivers • Line state de tection outputs • 15m A operation allow ing , Relay Contact A. Connects to XLB through relay contacts (K1 A) when the relay is energized. 4 XLB Loop Relay Contact B. Connects to XLA through relay contacts (K1 A) when the relay is energized. 5 XLC Loop Relay Contact C. Connects to XLD through relay contacts (K1B) when the relay is energized. 6 XLD Loop Relay Contact D. Connects to XLC through relay contacts (K1B) when the relay is


OCR Scan
PDF MH88632B MH88632BT MH88632B H88632B GG13444
1994 - wiring diagram dol starter

Abstract:
Text: Issued July 1994 B17749 Electronic motor protection relay with integral CTs RS stock number , 2 3 l Advance warning of trip condition l Auto/Manual reset, instant or delayed INSTANT RE SE T , isolation purposes. Introduction The overload relay is primarily intended for protection of 3-phase loads , an overload condition the output relay will detransformers of suitable rating. energise after a time , : INSTANT RE SE T Normal time-delayed tripping if any line ST AR T DE LAY current exceeds set trip level


Original
PDF B17749 wiring diagram dol starter 3 phase motor soft starter circuit diagram 3 phase motor auto starter circuit diagram wiring diagram dol motor starter wiring diagram for single phase dol motor starter 3 phase induction motor soft starter circuit diagram 3 phase motor starter circuit diagram wiring diagram single phase dol starter three phase DOL starter wiring wiring diagram motor start y
spdt relays

Abstract:
Text: latching or inhibit at set level · Output: 1 or 2 x 8 A SPDT relay N.D. or N.E. selectable · For mounting , housing (DUC01) or 36 mm plug-in module (PUC01) · LED indication for relay , alarm and power supply ON · , Ordering Key function, the ON-position of the relay output can be maintained. Inhibit function can be used to avoid relay operation when not desired (maintenance, transitions). The LED's indicate the state of the alarm and the output relay . DUC 01 D B23 500V Housing Function Type Item number


Original
PDF DUC01, PUC01 DUC01 DUC01) PUC01) DUC01 spdt relays 9 Volt DPDT Relay SPDT relay 6 Volt RH 25 RE2 voltage monitoring relay
2005 - Not Available

Abstract:
Text: R&E R&E International Preliminary Product Specification for RE230-RE233 Relay Driver / Timer , RE230-RE233 Relay Driver / Timer Products Typical Applications RE230 RE231 R&E International King of , Specification for RE230-RE233 Relay Driver / Timer Products RE232 RE233 R&E International King of , R&E International Preliminary Product Specification for RE230-RE233 Relay Driver / Timer Products , family of relay drivers designed for Worldtronics International. These products are intended for use in


Original
PDF RE230-RE233
rs 307

Abstract:
Text: Time-lag relay GL = Group signal relay AL = Station alarm relay RE = Auxiliary relay for individual remote , signals are provided by means of the auxiliary relay RE , here the remote signal contact operates after the , levels or the like. The relay marked RE is an RXMM 1 with a diode incorporated. Each RXMM 1 can be used , for this relay is given on page 15 in this catalogue. The references used in system RS 4 are GL and RE , means of a common time-lag relay that is delayed on pick-up, the time-lag being easily adjusted. If an


OCR Scan
PDF --83--I-- S-721 rs 307 RK 221 025 RXSU 21 bridge rectifier rs 307 AH 512 asea time-lag relay RI RK 211 025 rxtcb1 rs 307 rectifier RK 221 025 AS
rpdb

Abstract:
Text: ­ «il i ss -= S -S ■n ï -; <1 l D m ¡î" — J1 L- ï: RELAY DESCRIPTION Replaces information 5624 006 Ea RFR, Sept. , 1965 RK 50-300 E 1 Enel. J 5231 556 Reg. 5624 Re vers e-power relay type RPDB 11 Edition 1 Design and mode of operation Internal connection RPDB 11 is a time-lag power-direction relay mainly intended for use as a re verse-power relay in conjunction with diesel-generator sets running in parallel, on board ships. Fig. 1 liPDB 1J with connections from the front (64163) The relay is a variant of


OCR Scan
PDF
FLASHER IC DIP

Abstract:
Text: Frequency doubling indicates lamp outage D Two relay driver outputs with high current-carrying capacity and , left Start input right Start input hazard warning VS Control input relay 1 Control input relay 2 Lamp failure detection VS IC ground Output relay 1 VS Output relay 2 Oscillator OSC n . SIL n . SIR SIHW n . , stand-by mode until there is a voltage drop of V [ 6.9 V at the pull-down re sistor. Direction mode can , against reversed battery. Pin 11 and 13, Control output relay 1 and 2 The relay control outputs are


OCR Scan
PDF U2044B U2044B 28-Nov-97 FLASHER IC DIP
Not Available

Abstract:
Text: • Relay driver with Z diode • RF interference protected • Debounced input for , elay-con trol output -o F igu re 1. B lo c k diagram w ith external circuit Rev. A2: 07 , Svinimi 1 GND 2 RELAY 3 4 ON OFF 5 TOGGLE 6 OSC RC oscillator input 7 Vstab Vs Stabilized voltage 8 GND 1 RELAY u 8 Vs 2 7 Vstab ON 3 6 OSC OFF Reference point, ground 4 5 TOGGLE Relay control output


OCR Scan
PDF U6032B U6032B ISO/TR7637-1 D-74025 07-Jun-99
Not Available

Abstract:
Text: . Features · · · · Debounce time: 0.3 ms to 6 s RC oscillator determines switching characteristics Relay , -o F igu re 1. B lo c k diagram w ith external circuit TELEFUNKEN Semiconductors Rev. A2: 03 , Symbol GND RELAY ON OFF TOGGLE OSC Vstab Function Reference point, ground Relay control output , 3 RELAY 2 GND 1 u 8 Vs 7 V sta b 6 OSC TOGGLE 94 8844 8 Vs 5 F igu re 2. P in n in g Functional Description Power Supply, Pin 8 For reasons of interference


OCR Scan
PDF U6032B U6032B ISO/TR7637-1 U6032B-FP D-74025 03-Dec-97
RE7 RL13BU

Abstract:
Text: 0.7 A 8A 8A 8A 8A 8A Relay Page RE XL2TMJD RE XL4TMJD RE XL2TMBD RE XL4TMBD RE , Presentation 2 Zelio Time - timing relays 2 Presentation 521931-12-M A timing relay , relays: b "DIN rail mounted" relays (RE7, RE8, RE9, RE11, RE XL.) designed for mounting on DIN rails in an enclosure, RE11 b "Panel mounted" relays type RE 48A, designed for mounting on the front , switched off during the timing period, the relay reverts to its initial position. Application examples


Original
PDF 521931-12-M 28522-EN RE7 RL13BU RE11 RE48A RE11RAMU RL13BU TA21MW RE7 TL11BU RE7MA13BU TL11BU TA11MW
Not Available

Abstract:
Text: 53028 SPST SOLID-STATE RELAY M ILITA RY, DC SO LID STA TE RELAY FEATURES • • • â , solid-state relay . This light-weight device is resistant to damage from shock and vibration, and immune to , and 32 VDC. This solid-state relay is ideal for use in military systems, or wherever high , re sp o n sib ility fo r any c irc u its show n o r re p re se n t th a t the y are fre e fro m p a , €¢ (214) 272-3571 • FAX (214) 494-2281 53030 SPST SOLID-STATE RELAY jn • • • â


OCR Scan
PDF
OMRON plc programming manual ZEN-20C1DR-D-V2

Abstract:
Text: duration and applying 120VAC to power the timing circuitry, a dry contact relay will trip On or Off at , relay output On or Off for the user selected time. Using Fig. 2 - CNS Series Fig. 1 - CNM5 , EW AT PE OT RE E SHLAY ONF DEAL OF RV Y INTE LA DE ON 8 9 3 T ld E SE fie TIM , 0V AC S 25 0V RE A, , 12 C INA 10 HP VD CH 1/2 A, 30 IN 15 A, 15 DE MA O FF TI M E , 0.1F TIM E TIM E ER ON TO 10 0.1 TIM SE E C. CO TO10 240NTA SE CT VAC S C RE 10 AM CR SIS


Original
PDF 120VAC Z2691-ND ZEN-BAT01 240VAC 24VDC Z2692-ND ZEN-CIF01 Z2693-ND ZEN-ME01 OMRON plc programming manual ZEN-20C1DR-D-V2 OMRON plc programming manual ZEN-10C1DR-D-V2 OMRON zen plc PROGRAMMING MANUAL ZEN-10C1AR-A-V2 Zen-20C1DR-D-V2 omron plc 10C1DR-D-V2 OMRON plc programming manual ZEN TS 11178 K10 relay CNT-35-96
LU-12 relay

Abstract:
Text: Functional Description Figure 1 shows the switch characteristics of the relays. The relay exhibits , exhibits a nega tive temperature coefficient, thereby reducing the current-limit value when relay temperature is increased. An extended clamp condition, which increases relay temperature, decreases the current-limit value, result ing in a current foldback characteristic. When the over load is removed, the relay , A relay , to turn the relay on, forward current is applied to the LED. The amount of current applied


OCR Scan
PDF 1-888-Infineon LH1525AT/AAB/AABTR LU-12 relay PED relay
ASEA motor bv

Abstract:
Text: re fay with static measuring unit 3 Instantaneous relay with electromechanical measuring unit 4 Delayed relay with static measuring unit 5 Delayed relay with electromechanical measuring unit 7 Delayed relay with static measuring unit and with external blocking possibilities 10 Delayed relay with elect ro-mechanical measuring unit and with external blocking possibilities Delayed relay with electromechanical , Current relay RXlC 1 S19 Auxiliary relay RXME 1 3S5 Auxiliary re lay RX ME IS'-. 1) External blocking


OCR Scan
PDF 0002-AB 101-AB 0011-AB 110-AB 0012-AB 100-AB 0003-AA 113-AA 0005-BA 115-BA ASEA motor bv TRW catalogue static overcurrent relay RXIG 2 RTXP10 ASEA mt 100 circuit diagram of rxig 28 110-CB 107J circuit diagram of 7432
electromatic VOLTAGE LEVEL RELAY SM 125 220

Abstract:
Text: 165 SB 169 SB 160 SB 285 SB 269 34 35 46 43 44 42 SC 110 SC 115 SC 210 SC 215 49 50 TIME RELAY FOR , . RELAYS FOR IN D U C T IV E /C A P A C IT IV E SENSORS Monostable relay for one sensor without amplifier (NAMUR) Bistable relay for two sensors without amplifier (NAMUR) LEVEL CONTROL RELAYS SD 110 SD 170 SD , RELAYS Phase sequence and phase breaking relay . Phase sequence and phase breaking relay . Measures on , angle error (>15°) and phase breaking relay . Phase angle error (knob-adjustable: 5-15°) and phase


OCR Scan
PDF inc12 electromatic VOLTAGE LEVEL RELAY SM 125 220 electromatic s system sv 115 230 electromatic RELAY SM 115 220 electromatic s system st 125 115 electromatic denmark sc 185 220 electromatic s system sb 165 electromatic s system SA 105 220 electromatic s system ST 125 220 electromatic electromatic s system sm 105 220
PLC Allen-Bradley Micrologix 1761-L16AWA

Abstract:
Text: Inputs, 8 Relay Outputs, AC Power (1761-L20AWA-5A) ·1 2 DC Inputs, 8 Relay Outputs, AC Power (1761-L20BWA-5A) ·1 2 DC Inputs, 8 Relay Outputs, DC Power (1761-L20BWB-5A) All models have 4 Analog inputs: · 2 , ll S o ftw a re W IN tellig en t LINX c onf i gur ed fo r DF1 H a lf-D u p le x M a ste r M ic ro , Resolution 0 to 32,767 15 bit 3 msec (maximum) ± 0.7% of full scale 1 T h e an a lo g in p u t re s o , solutions. Input options include AC, DC and analog (current or voltage). Output choices are relay , TRIAC


OCR Scan
PDF 16-bit PLC Allen-Bradley Micrologix 1761-L16AWA 1761-L32AWA 1761-L20BWA-5A 1761-L20BWB-5A 1761-L10BWA 1761-L20aWA-5A 1761L32AWA 1761-L32BWA Allen-Bradley micrologix 1000 1761-L10BWB
1999 - AM79231

Abstract:
Text: P RE L IM IN AR Y Relay Driver Specifications Item Condition On Voltage R2,R3 Off , voltage sensing s Ring relay driver for external ringing - Power cross and fault detection s Integrated test load switches/ relay drivers BLOCK DIAGRAM Signal Transmission AD SA HPA HPB , Fault Meas. VBL Switch Driver VBH Relay Control R2 R3 RYE Relay Drivers P1 Input Decoder and Control Registers P2 P3 LD R1 Relay Driver 1 BGND GND VCC Pub. #


Original
PDF Am79231 Am79Q2243 DA79 PL032 TISP61089
9 Volt DPDT Relay

Abstract:
Text: signal plus/minus monitoring relay (DIC01) · Selection of measuring range by DIP-switches · Adjustable , SPDT relay N.D. or N.E. selectable · For mounting on DIN-rail in accordance with DIN/EN 50 022 (DIC01 , indication for relay (s), alarm and power supply ON · Galvanically separated power supply PIC01 Product , delay. Only for DIC01 each set level can work with a single SPDT relay . Owing to the built-in latch function, the ON-position of the relay output can be maintained. Inhibit function can be used to avoid


Original
PDF DIC01, PIC01 DIC01 DIC01) PIC01) 9 Volt DPDT Relay A82-10 PIC01
Supplyframe Tracking Pixel