The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
J2014001L601A GE Critical Power Compact Power Line Shelves, GP100, 3Φ-480, dual, redundant, I2C shelf configured for 54Vdc output, configured for slot 1, hardware and shelf interconnect included
J2014001L601 GE Critical Power Compact Power Line Shelves, GP100, 3Φ-480, dual, redundant, I2C shelf configured for 48Vdc output, configured for slot 1, hardware and shelf interconnect included
150025012 GE Critical Power Galaxy Pluto Plus Controller Back Plane – 48V Version
TPS2350DG4 Texas Instruments Hot Swap Power Manager For Redundant -48V Supplies 14-SOIC -40 to 85
TPS2350DR Texas Instruments Hot Swap Power Manager For Redundant -48V Supplies 14-SOIC -40 to 85
TPS2350DRG4 Texas Instruments Hot Swap Power Manager For Redundant -48V Supplies 14-SOIC -40 to 85

redundancy version Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
2008 - turbo encoder design using xilinx

Abstract: CRC24 LTE DL Channel Encoder lte turbo encoder lte xilinx turbo CRC lte CRC-24 convolution encoder XTP025 design of lte turbo encoder
Text: function performs appropriate puncturing according to the AMC parameters and redundancy version , version of the core: · New Features · Bug Fixes · Known Issues Ordering Information , document: Date Version Description of Revisions 09/19/08 1.0 Initial Xilinx release. 04


Original
PDF XMP023 16-bit turbo encoder design using xilinx CRC24 LTE DL Channel Encoder lte turbo encoder lte xilinx turbo CRC lte CRC-24 convolution encoder XTP025 design of lte turbo encoder
2008 - Turbo decoder Xilinx

Abstract: xilinx lte TURBO decoder CRC lte TB lte LTE uplink XMP024 turbo decoder automatic repeat request redundancy version
Text: size · Redundancy Version Calculation - Offset start position calculation based on RV index , UCI Uplink Control Information Revision History Date Version Revision 09/19/08 1.0 Xilinx initial release. 06/24/09 2.0 Updated to version 2 of the core. Notice of Disclaimer


Original
PDF XMP024 Turbo decoder Xilinx xilinx lte TURBO decoder CRC lte TB lte LTE uplink turbo decoder automatic repeat request redundancy version
2008 - bch verilog code

Abstract: vhdl code lte vhdl code CRC for lte xilinx vhdl codes CRC24 CRC lte vhdl convolution coding redundancy version Xilinx ISE Design Suite LTE DL Channel Encoder
Text: redundancy version . Data output on a code block basis for the DL-SCH, PCH, and MCH channels. The HI or CFI , version of the tools, see the ISE Design Suite 13: Release Notes Guide © Copyright 2008­2012 Xilinx , following information is listed for each version of the core: · · · New Features Bug Fixes Known Issues , : Date 09/19/08 04/24/09 04/19/10 06/22/11 08/15/11 01/18/12 Version 1.0 2.0 3.0 3.1 3.2 3.3 Xilinx


Original
PDF XMP023 ZynqTM-7000, bch verilog code vhdl code lte vhdl code CRC for lte xilinx vhdl codes CRC24 CRC lte vhdl convolution coding redundancy version Xilinx ISE Design Suite LTE DL Channel Encoder
2010 - Not Available

Abstract: No abstract text available
Text: Professional Comparison Chart, form 1681 Note on Firmware If you are not using controller redundancy , use brain and controller firmware version 8.5c with PAC Project 9.0. It supports all other features in 9.0. If you are using controller redundancy , you will need firmware version 9.0 for your redundant , PAC Project 9.0 Release Notes Welcome to PAC Project 9.0 Welcome to version 9.0 of Opto 22 , Display and PAC Control, PAC Project Professional 9.0 now supports the controller-level redundancy


Original
PDF opto22
2007 - Allen-Bradley e1 plus

Abstract: PID controller Wireless display project modbus circuit OPTO-22 mistic PID control modbus B100 B200 B3000
Text: version 9.0 of PAC ProjectTM Basic and PAC Project Professional. See Opto 22 form #1677, the SNAP PAC , redundancy or segmented control network · Support for controller redundancy (S-series) · · · · · , Graphical debugger · Conversion utility for OptoControl strategies ( version 4.1 and newer) · Support for serial mistic I/O units* · Ethernet link redundancy (with R-series I/O units) · Controller redundancy , (PID) loops Ethernet link redundancy Built-in I/O unit (in SNAP PAC R-series controllers) SNAP


Original
PDF 1681-100416--PAC Allen-Bradley e1 plus PID controller Wireless display project modbus circuit OPTO-22 mistic PID control modbus B100 B200 B3000
AX-RJ48-8E1

Abstract: MGX-RPM-PR-512 CAB-AC-125V CAB-5686-04 DB15 to BNC AX-RJ48-8T1 MGX-SMFIR-4-155 EN60825-1 CISPR22 rj48 to db9
Text: IP+ATM services · Full redundancy for maximum service flexibility · Compact form factor Services · , Optional Redundancy All core components are optionally redundant to 100-percent system redundancy , MGX-FR-IR72= RPM 1:N Redundancy License for 8230 chassis RPM-1-TO-N-8230 RPM 1:N Redundancy License , Serial version 2 MGX-FRSM-HS2 Frame Service Module, High-speed Serial version 2 MGX-FRSM-HS2 , Connectors AX-RJ48-8T1 Eight Port T1 Back Card with RJ48 Connectors AX-RJ48-8T1= Redundancy Back


Original
PDF MGX8250-SW-1140 MGX8230SW-1140 MGX8230-SW-1140 MGX8250SW-1132 MGX8250-SW-1132 MGX8230-SW-1132 AX-RJ48-8E1 MGX-RPM-PR-512 CAB-AC-125V CAB-5686-04 DB15 to BNC AX-RJ48-8T1 MGX-SMFIR-4-155 EN60825-1 CISPR22 rj48 to db9
2009 - PLC based WATER LEVEL CONTROL

Abstract: DK9322-0809-0004 automatic water level controller project project of automatic water level controller PLC based water level controller project on automatic water level controller project on water level control Beckhoff plc of PLC based water level controller
Text: EtherCAT Application Note DK9322-0809-0004 EtherCAT Master Redundancy Keywords redundancy basis control redundancy EtherCAT master warm standby redundancy EtherCAT EtherCAT Master Redundancy - Warm Standby Control redundancy can enhance productivity and availability in , the required switching time is guaranteed. This application note explains the basic redundancy , redundancy , an unexpected failure of the control system not only leads to a loss of existing system


Original
PDF DK9322-0809-0004 PLC based WATER LEVEL CONTROL DK9322-0809-0004 automatic water level controller project project of automatic water level controller PLC based water level controller project on automatic water level controller project on water level control Beckhoff plc of PLC based water level controller
2013 - CRC-15-CAN

Abstract: CRC 8 cyclic redundancy check bluetooth usb CRC-16 v.41 ECMA-182 CRC-16-CCIT psoc full projects CRC-8 ccitt
Text: Component Datasheet Cyclic Redundancy Check (CRC) Version Description of Changes Fixed polynomial , PSoC® CreatorTM Component Datasheet Cyclic Redundancy Check (CRC) 2.40 Features 1 to 64 , General Description The default use of the Cyclic Redundancy Check (CRC) component is to compute the CRC , : 001-86301 Rev. * Revised February 20, 2013 Cyclic Redundancy Check (CRC) PSoC® CreatorTM Component , . * PSoC® CreatorTM Component Datasheet Cyclic Redundancy Check (CRC) Component Parameters Drag a


Original
PDF
CEI 23-16/VII

Abstract: rj48 to db9 RJ48 DB15 to BNC mgx-ac2-2 CAB-5682-06 bs 1363 cable MGX-RPM-PR-512 IEC-61000-4-2 PXM-45
Text: redundancy for maximum service flexibility Services · · · · · · · · · Frame Relay ATM Frame , .35 Ethernet Fast Ethernet Optional Redundancy All core components are optionally redundant to 100-percent system redundancy , including the control processor, switching fabric, critical backplane signals, and , = RPM 1:N Redundancy License for 8250/ 8850 chassis RPM-1-TO-N-8X50 RPM 1:N Redundancy License , Serial version 2 MGX-FRSM-HS2 Frame Service Module, High-speed Serial version 2 MGX-FRSM-HS2


Original
PDF PXM-45 MGX8230SW-1140 MGX8230-SW-1140 MGX8250SW-1132 MGX8250-SW-1132 MGX8230-SW-1132 MGX8230SW-1132 CEI 23-16/VII rj48 to db9 RJ48 DB15 to BNC mgx-ac2-2 CAB-5682-06 bs 1363 cable MGX-RPM-PR-512 IEC-61000-4-2
2012 - CRC-8 ccitt

Abstract: No abstract text available
Text: : 001-85007 Rev. * PSoC® CreatorTM Component Datasheet Cyclic Redundancy Check (CRC) Version , PSoC® CreatorTM Component Datasheet Cyclic Redundancy Check (CRC) 2.30 Features 1 to 64 , General Description The default use of the Cyclic Redundancy Check (CRC) component is to compute the CRC , : 001-85007 Rev. * Revised December 10, 2012 Cyclic Redundancy Check (CRC) PSoC® CreatorTM Component , . * PSoC® CreatorTM Component Datasheet Cyclic Redundancy Check (CRC) Component Parameters Drag a


Original
PDF
2012 - crc8 1wire

Abstract: CRC-16 ccitt CRC-64-ISO CRC-8 ccitt ECMA-182 code 4 bit LFSR
Text: . * PSoC® CreatorTM Component Datasheet Cyclic Redundancy Check (CRC) Version Description of , PSoC® CreatorTM Component Datasheet Cyclic Redundancy Check (CRC) Features 1 to 64 bits Time , Description 2.20 The default use of the Cyclic Redundancy Check (CRC) component is to compute the CRC , : 001-79292 Rev. * Revised May 15, 2012 Cyclic Redundancy Check (CRC) PSoC® CreatorTM Component , . * PSoC® CreatorTM Component Datasheet Cyclic Redundancy Check (CRC) Component Parameters Drag a


Original
PDF
2005 - ALTERA 2GX

Abstract: cyclic redundancy code
Text: SerialLite II MegaCore Function Errata Sheet October 2005, MegaCore Version This document addresses known errata and documentation changes for the SerialLite II MegaCore® function version 1.0.0 , Segment Size" on page 3 4. "Cyclic Redundancy Code Checking (CRC) Cannot Be Enabled in Some , : Quartus II Version 5.1 Service Pack-2GX Lane rates above 3.125 Gbps and corresponding data path widths of 32 bits per lane Quartus II Version 5.1 Service Pack 1 Unidirectional mode Asymmetric


Original
PDF
PLC projects

Abstract: Engineering Design Automation
Text: /pressroom Opto 22 Introduces SNAP PAC Redundancy Option Kit Hardware and Software Kit Designed to Build , released the SNAP PAC Redundancy Option Kit (SNAP-PAC-ROK), used to design an Ethernet-based redundant , Project Professional 9.0 software suite, combined with the SNAP PAC Redundancy Option Kit, customers can , " redundancy ," provides many advantages. Foremost among these is a significant reduction in the control system , facilities of one of the world's largest oil companies. He claims that redundancy features make Opto 22


Original
PDF opto22 PLC projects Engineering Design Automation
DPCI-154-1203

Abstract: CPCI-354T-1203
Text: Sharing and Internal OR-ing Diodes for N+1 Redundancy cHigh Current 5 V and 3.3 V Outputs c150 W in 3 U , Input with Power Factor Correction c48 VDC Input Version and AC Universal Input Version Available Both , redundancy and modularity. These low-cost, ® ® high density units meet the electrical and mechanical , systems, telecommunications and industrial equipment requiring redundancy and modularity. These low-cost , applications that require redundancy over extended temperature ranges. These high-density, single-output


Original
PDF 50-Up DPCI-154-1203 CPCI-354T-1203
2011 - crc 64

Abstract: CRC32-C CRC-15-CAN CRC32C CRC-8 ccitt
Text: Redundancy Check (CRC) Version Description of Changes Add validator to Resolution parameter. Add reset , PSoC CreatorTM Component Datasheet ® Cyclic Redundancy Check (CRC) 2.10 Features 1 to 64 , General Description The default use of the Cyclic Redundancy Check (CRC) component is to compute the CRC , : 001-73569 Rev. * Revised October 17, 2011 Cyclic Redundancy Check (CRC) PSoC CreatorTM Component , . * PSoC CreatorTM Component Datasheet ® Cyclic Redundancy Check (CRC) Component Parameters Drag


Original
PDF
2006 - Sil4726

Abstract: SII4726 SiI3132 Manager 4726 SATA hard disk controller SIL4 MAN-002000-000
Text: SiI 4726 Manager User's Guide Version 2.6 Document Number: MAN-002000-000 Document Number: MAN-002000-000 Version 2.6 Copyright © 2006, Silicon Image, Inc. All rights reserved. No part , Document Number: MAN-002000-000 Version 2.6 Contents About this guide , . 21 Sil 4726 Manager User's Guide Page iii Document Number: MAN-002000-000 Version 2.6 , . 54 Sil 4726 Manager User's Guide Page iv Document Number: MAN-002000-000 Version 2.6


Original
PDF MAN-002000-000 Sil4726 SII4726 SiI3132 Manager 4726 SATA hard disk controller SIL4 MAN-002000-000
2010 - CRC-8 ccitt

Abstract: ECMA-182 CRC-15-CAN
Text: 29 Cyclic Redundancy Check (CRC) PSoC® CreatorTM Component Data Sheet Version 2.0 , PSoC® CreatorTM Component Data Sheet Cyclic Redundancy Check (CRC) 2.0 Features · · · · · · , components General Description The default use of the Cyclic Redundancy Check (CRC) component is to , Number: 001-62889 Rev. *A Revised November 30, 2010 Cyclic Redundancy Check (CRC) PSoC® CreatorTM , PSoC® CreatorTM Component Data Sheet Cyclic Redundancy Check (CRC) Parameters and Settings Drag


Original
PDF
TC1700

Abstract: RS-449 1300nm optic laser TCRM192 laser diode v35
Text: Mode (850/1300/1550nm) · Built-In Power Redundancy · Optical Redundancy (optional) · Recessed , redundancy is standard when the TC1700R is used with the TCRM192 Rack Assembly and optional in standalone versions. Optical redundancy is optional. and multiple interfaces, the TC1700 Diagnostics are , temperature version (-20° to 70°C), Model TC1700T, is also available. *Contact factory for higher requirements (Laser version ) TC Communications, Inc. 17575 Cartwright Rd. Irvine, CA 92614 U.S.A. Tel


Original
PDF TC1700 RS-232 850/1300/1550nm) TC1700 256Kbps RS-449 1300nm optic laser TCRM192 laser diode v35
AC800F

Abstract: ABB distributed control systems abb harmony opc freelance 2000 DCP10 AC800F* OPC freelance 2000 freelance 2000 engineering DCS Automation PDF Notes modicon system sisco
Text: components required. Redundancy and configuration synchronization Link Connectivity Gateway , , supporting data buffering/burst handling, exception reporting, and redundancy . Heartbeat messages are , Requirements Operating System Database Application Windows NT Workstation or Server version 4.0 / Windows 2000 Microsoft Access version '97 / 2000 GENERAL PC REQUIREMENTS Characteristics Minimum , SOFTWARE LEVELS System Version Levels Network 90 semAPI version 2.4 and Harmony OPC server


Original
PDF 2000TM DCP10 AC800F, 3BCA030015R1601 AC800F ABB distributed control systems abb harmony opc freelance 2000 DCP10 AC800F* OPC freelance 2000 freelance 2000 engineering DCS Automation PDF Notes modicon system sisco
2010 - DF1 PROTOCOL

Abstract: MySQL opto counter B100 B200 B3000 G4D32RS Wireless display project
Text: , database connectivity, and support for Ethernet link redundancy and controller redundancy . Legacy , for segmented networks or Ethernet link redundancy . Wired+Wireless models can run on a wireless LAN , (such as a SNAP-LCM4 or M4RTU) via an Ethernet connection, controller firmware version R4.1a or newer , A computer with at least the minimum processor and memory required for your version of Microsoft , table compares the features in version 9.0 of PAC ProjectTM Basic and PAC Project Professional. See Opto


Original
PDF opto22 DF1 PROTOCOL MySQL opto counter B100 B200 B3000 G4D32RS Wireless display project
2009 - 1756-EN2T

Abstract: 1756-rm Allen-Bradley 1756-RM 1756-RMC1 LOGIX5563 1756-CPR2 1756-TD001 1756-cn2r 1756 Rm CPU 1756-l63
Text: ControlLogix Enhanced Redundancy System Catalog Numbers 1756-CN2, 1756-CN2R, 1756-CN2RXT, 1756 , . . . . . . . . . . 11 Chapter 1 About Enhanced Redundancy Systems Features of the Enhanced Redundancy System . . . Enhanced versus Standard Redundancy . . . . . Enhanced Redundancy System Components. . . . . Example of an Enhanced Redundancy System. Enhanced Redundancy System Operations . . . . . , 29 29 32 33 Chapter 2 Design an Enhanced Redundancy System 5Publication 1756-UM535A-EN-P -


Original
PDF 1756-CN2, 1756-CN2R, 1756-CN2RXT, 1756-EN2T, 1756-EN2TXT, 1756-L61, 1756-L62, 1756-L63, 1756-L63XT, 1756-L64 1756-EN2T 1756-rm Allen-Bradley 1756-RM 1756-RMC1 LOGIX5563 1756-CPR2 1756-TD001 1756-cn2r 1756 Rm CPU 1756-l63
ABB CMC

Abstract: cnet abb CMC-50 cmc 50 cmc50
Text: Primarily the modules differ in the higher transmission rate on the redundancy link. Only modules of the same type may set redundant. If nevertheless a CMC 50-2 is set as a redundancy partner to a CMC 50 or CMC 50-1 or a CMC 50-1 is set as redundancy partner to a CMC 50 the active unit will generate an error message: " Redundancy link failure". The disturbance LED on the front panel signals a partial disturbance. In this case the redundancy balancing will be done via the Cnet (C). The transmission of


Original
PDF
ASEA

Abstract: RADSS Boveri B03 ABB CT
Text: fault current? High CT or pilot Number of circuits > 10? No Operate speed? [ 1 cycle Built-in redundancy , RADSS Version D B03-6010E Selection guide B03-0260E Bus protection Pa9e 2 Dedicated CT's? High fault current? High CT or pilot burden? Number of circuits > 10? Built-in redundancy ? All CT's equal? RADHA B03-6011E Yes \ No Yes Yes Yes Yes No RADSS Version D B03-6010E ASEA RELAYS S


OCR Scan
PDF B03-0260E B03-6011E B03-6010E S-72183 ASEA RADSS Boveri B03 ABB CT
TC1620R

Abstract: LED 1550nm TC1620 TC1620S TC1620T E1 HDB3 DSA004778
Text: reliability. Important features include Local and Remote Loopback, Power/Optical redundancy (optional), multiple power options and a replaceable Line Interface Module. Power redundancy is standard; optical redundancy is optional. The PC Card version is typically used with the TCRM192 Rack Mount Card Cage, which can hold up to 10 single or five double-modem type cards. An extreme temperature version (-20oC to , T1/E1 Fiber Optic Modem Model TC1620R/S · Distances up to 100km · Power/Optical Redundancy


Original
PDF TC1620R/S 100km 850/1300/1550nm) 12/24/-48VDC, 115/230VAC TC1620R) TC1620S) TC1620R/S 100km 1550nm. TC1620R LED 1550nm TC1620 TC1620S TC1620T E1 HDB3 DSA004778
2010 - EGR Valve Position Sensor

Abstract: No abstract text available
Text: integrated within the sensor too. Furthermore full redundancy can be achieved by employing a dual core version or the simple placement of two sensors within the housing. The robust PSC360 is sealed and flange , version . Typ 17mA for redundant version . • IP65 (others upon request) STANDARDS • EN 55022 class B , redundant 3 = full redundancy W Output Type Shaft PSC360 PSC360U A- Switch ERA , output function NOTES: (1) "L" version is only available for PSC360U (2) Switch available only for


Original
PDF PSC-360 PSC-360 PSC360 PSC360U EGR Valve Position Sensor
Supplyframe Tracking Pixel