The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
ATEXTWIFI Microchip Technology Inc BOARD EVAL 802.11B/G WIFI HDG104
PT1000-1400-VM API Delevan General Purpose Inductor, 1000uH, 15%, 1 Element, Iron-Core, RADIAL LEADED
PT100-1260HM API Delevan 1 ELEMENT, 100uH, POWDERED IRON-CORE, GENERAL PURPOSE INDUCTOR, RADIAL LEADED
PT1000R-2050-VM API Delevan General Purpose Inductor, 1000uH, 15%, 1 Element, Iron-Core, RADIAL LEADED, ROHS COMPLIANT
PT100-1100HM API Delevan 1 ELEMENT, 100uH, POWDERED IRON-CORE, GENERAL PURPOSE INDUCTOR, RADIAL LEADED
PT1000-1400HM API Delevan 1 ELEMENT, 1000uH, POWDERED IRON-CORE, GENERAL PURPOSE INDUCTOR, RADIAL LEADED

pt100 atex Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
2015 - 1XPt100

Abstract:
Text: CombiTemp TFRN TM Industrial – RTD temperature sensor Main features „„ Pt100 sensor element, „„ ATEX „„ Programmable by touch screen „„ Easy and full programmable 2- or 4 , Accuracy Pt100 output as to DIN/EN/IEN 60751 Transmitter output <±0.1 °C / <±0,25 °C Connections Threaded Sensor type RTD type Pt100 (acc. to DIN/EN/ IEC 60751) Single or Double 2 , Transmitter, type FlexTop 2202 - Standard Input Pt100 Input Pt100 / Pt1000 (universal) Output


Original
PDF Pt100 1xPt100 PT-100 RTD 3 wire transmitter pt100 temperature sensor PT100 temperature sensor data sheet PT100+3+wire+temperature+sensor+data+sheet PT1000
2015 - PT100 3 wire temperature sensor

Abstract:
Text: CombiTemp TFRH TM Hygienic – RTD temperature sensor Main features „„ Pt100 sensor , mounted 4.20 mA t ­ransmitter, FlexTop type 22xx „„ HART®, PA „„ ATEX „„ EHEDG , -50 … 250 °C Apply to Accuracy Pt100 output as to DIN/EN/IEN 60751 Transmitter output , without notice Temperature, Ambient RTD type Pt100 (acc. to DIN/EN/ IEC 60751) Single or Double 2 , Standard Input Pt100 Input Pt100 / Pt1000 (universal) Output Accuracy Input Output


Original
PDF Pt100 1xPt100 DN25/DN38 PT100 3 wire temperature sensor PT100 temperature sensor PT100 temperature sensor class B PT100 temperature sensor data sheet PT100 standard IEC 60751 accuracy
2014 - PT100 temperature sensor

Abstract:
Text: steel, AISI 316L (1.4404) High flexible silicone, grey Sensor element, Pt100 - DIN/EN/IEC 60751 Pt100 1/1 DIN class B Pt100 1/3 DIN class B Pt100 1/6 DIN class B Pt100 1/1 DIN class A ± (0.3 + , Single element 1 x Pt100 Output Further information can be found in separate data sheet for DFON, D21.09 Resistance, ceramic terminal Analogue, built in transmitter Pt100 signal, 2, 3 or 4 wire 4.20 mA, 4.20 mA HART Type LCD Single element 1 x Pt100 Front Glass Polycarbonate


Original
PDF Pt100 Pt100 PT100 temperature sensor PT100 temperature sensor data sheet PT100 class A pt100 temperature sensor transmitter 4-20 ma
2015 - PT100 3 wire temperature sensor

Abstract:
Text: . Output Pt100 /Pt1000 Ceramic terminal block. 4.20 mA temperature transmitter Sensor tube , . Sensor element, Pt100 - DIN/EN/IEC 60751 Pt100 DIN class B Pt100 1/3 DIN class B Pt100 1/6 DIN class B Pt100 DIN class A ± (0.3 + 0.005xt) °C ± 1/3 x (0.3 + 0.005xt) °C ± 1/6 x (0.3 + 0.005xt) °C ± (0.15 + 0.002xt) °C Single element Double element 1 x Pt100 2 x Pt100 Connection 2 , sensor insert Temperature transmitter Pt100 Single element 2-w 3-w White Double


Original
PDF Pt100/Pt1000 ZPX1-002 ZPX1-001 EN/2014-08-25 04-TCR6 PT100 3 wire temperature sensor PT100 standard IEC 60751 accuracy pt1000 class B, DIN EN 60751 PT1000 Sensor Data
2007 - V10681

Abstract:
Text: Arduous Environments ­ Ex certified including Ex d according to ATEX Constructed from durable , available ­ Ex certification according to ATEX with FM and CSA certified versions available Low cost of , Ex d according to ATEX SS/HDA_5 Description Our Heavy Duty Temperature Sensors have been , Sensor for Arduous Environments ­ Ex certified including Ex d according to ATEX SS/HDA_5 Sensor , certified including Ex d according to ATEX SS/HDA_5 Connection Heads Without Display Without


Original
PDF
2013 - Not Available

Abstract:
Text: BattTemp Pt100 Thermometer Battery powered thermometer Front-configurable display Input for Pt100 sensor Measuring range -200.850°C Ambient temperature -10.70°C Accuracy 0.3°C Battery lifetime approx. 3 years IP65 - Relative humidity 98% Ex ia IIC T4/T5, ATEX II 1G Part of the CombiTemp series Description BattTemp is a battery powered display with an internal Pt100 amplifier. BattTemp , wide range of Pt100 tube or cable sensors available. BattTemp is the replacement for mechanical style


Original
PDF Pt100 EN/2013-03-03
2010 - pt100/RTD PT100

Abstract:
Text: Data Sheet DS/TTH200-EN Head mounted Temperature Transmitter TTH200 HART, Pt100 (RTD , 61508 Approvals for explosion protection - ATEX , IECEx, Zone 0 - FM / CSA Configuration - DTM - EDD Contents Head mounted Temperature Transmitter TTH200 HART, Pt100 (RTD), thermocouples , .11 7.3 Safety specifications for Intrinsic Safety ATEX / 7.4 TTH200-E2, Non-Sparking ATEX


Original
PDF DS/TTH200-EN TTH200 Pt100 DS/TTH200seconds 3KXT231002R1001 DS/TTH200-EN pt100/RTD PT100 MIL-T-24388 PT200 reference table PT50 temperature sensor PT200 RTD reference table PT200 rtd ni1000 DIN 43760 PT100 B DIN 43729 rtd pt100 sensor JIS C1604 PT100 IEC 751
2004 - Resistance characteristic Ni1000

Abstract:
Text: current limitation Approvals for explosion protection ­ intrinsically safe ATEX ­ pressure proof enclosure/flameproof ATEX ­ pressure proof enclosure, explosionproof (acc. divisions) FM, CSA in preparation ­ Suitable for connecting to systems according to: ­ Entity model ­ FISCO model Dust Ex ATEX , Pt100 , via software switchable (no jumper necessary) Resistance (temperature linear) Resistance thermometer n · Pt100 up to Pt1000 (IEC 751: n = 0.1; 0.5; 1; 2; 5; 10) (JIS 1604: n = 0.1; 0.5; 1; 2; 10


Original
PDF TF202/TF202-Ex Resistance characteristic Ni1000 ABB Pt100 3 wire EC certificate PTB ATEX 1144 X accuracy of K type thermocouple pt100 atex PT1000 temperature sensor PT100 IEC 751 pt 100 temperature sensor abb Thermocouple Type L Ni120
2014 - PT100 3L

Abstract:
Text: the processing system. English page 1.4 Deutch Seite 5…8 Française Page 9.12 ATEX , /IEC 60751) Material Stainless steel, AISI 316 L Sensor element Pt100 Sensor tube , Single element Double element 1 × Pt100 2 × Pt100 Connection 2-wire or 4-wire Sensor , for M20 www.baumer.com 3-w 4-w Pt100 White White 2-w 4-w 2-w Red - Pt100 Red 3-w 2-w Red White White Double element Ambient temperature RTD output


Original
PDF
2004 - ABB Pt100 3 wire

Abstract:
Text: ­ approvals according to ATEX for Ex i installation with protection tube in Zone 0 ­ protection , Fieldbus TR04-Eco/TRO4 TS02/TS02-Ex TH02/TH02-Ex TF12/TF12-Ex TF02/TF02-Ex Pt100 /40K Pt100 to 1000/20K Ni100, Ni500/20K Pt50 to Pt100 to Pt1000/20k Ni100/20k Pt50 to Pt100 to Pt1000 Ni50 to Ni100 to Ni1000 Pt10 to Pt100 to Pt1000 Ni50 to Ni100 to Ni1000 Cu10, Cu100 Input , status Up to 2 digital values + status DMT: ATEX (in preparation) II 3G EEx n A II T6


Original
PDF
2013 - Siemens PT100 temperature sensor

Abstract:
Text: TH100 two-wire system ( Pt100 ) ■Overview ■Application Used in conjunction with Pt100 , 94/9/EC ( ATEX ), as well as FM and CSA regulations. ■Function The SITRANS TH100 dispenses with electrical isolation and universal sensor connection to provide a low-cost alternative for Pt100 , Pt100 resistance thermometer (2, 3 or 4-wire system) is amplified in the input stage. The voltage, which , potentially explosive areas Input Pt100 EMC_1 IC MUX A/D Uref Ic 6 A/D 5 Pt100 4


Original
PDF TH100 Pt100) Pt100 TH100 TH100/TH200. 7NG3190-6KB) TICA1234HEAT Pt100 Siemens PT100 temperature sensor pt100 temperature sensor circuit diagram pt100/MTBF SIEMENS Siemens PT100 temperature sensor 2 wire Siemens PT100 temperature sensor din iec 60751 pt100 circuit diagram pt100 multiplexer pt100/TH200
2013 - Not Available

Abstract:
Text: FlexTop 2202 Temperature Transmitter 4.20 mA transmitter for Pt100 sensors 2-, 3- or 4 , Engineering unit °C or °F PC datalogging Excellent temperature stability Ex ia IIC T5/T6, ATEX II 1G Description FlexTop 2202 is a 4.20 mA loop-powered transmitter for Pt100 sensors. The Flex-Program has a , ) Pt100 Standard IEC/DIN/EN 60 751-2 Long-term test IEC 770 6.3.2 RTD measuring current , NAMUR NAMUR NE21 Approval Ex ia IIC T5/T6, ATEX II 1G Supply range Minimum span 25Â


Original
PDF Pt100
Not Available

Abstract:
Text: FlexTop 2202 Temperature Transmitter 4.20 mA transmitter for Pt100 sensors 2-, 3- or 4 , , ATEX II 1G Ex nA II T5, ATEX II 3G Description FlexTop 2202 is a 4.20 mA loop-powered transmitter for Pt100 sensors. The Flex-Program has a datalogging facility enabling the user to monitor , . Vibrations GL, test 2 (IEC 68-2-6) Pt100 Standard IEC/DIN/EN 60 751-2 Long-term test IEC 770 , NAMUR NAMUR NE21 Approval Ex ia IIC T5/T6, ATEX II 1G Compensation for cable error


Original
PDF Pt100
2015 - ZPW2-321

Abstract:
Text: ATEX I M1 Ex ia I Ma ATEX II 1G D Ex ia IIC T6 or T5 Ga Ex ia IIIC T80°C or T95°C Da IP6x > 2x , G 1/2 EN 837 Clamp DIN ISO 2852 M12, 5 pins M12, 8 pins IP 67 3-A, ATEX M1 Ex ia I Ma ATEX II , Sensor -50 … +250 °C Ambient -40 … +160 °C Sensor element Pt100 Pt100 Media -40 … 85 °C Ambient -30 … 70 °C with DFON display Ambient -30 … 80 °C with BattTemp display Pt100 , 69K ATEX II 1G, Ex ia IIC T5 ATEX II 3G, Ex nA II T5 CombiView ® DFON and BattTemp (optional


Original
PDF 0x/12 11xxxxxx ZPW2-321 W02 pt100 ZPX3-7233
Not Available

Abstract:
Text: thermo detectors (RTD) Ni100/ Pt100 , thermoelement types B, E, J, K, L, N, R, S and T or low voltages in , . Resistance thermo detectors Ni100/ Pt100 in 2, 3 or 4-wire-technology can be operated alternatively at the input circuit of the measuring amplifier. The Ni100/ Pt100 input can either be used as external cold , errors: 0 resp. > 22 mA Intrinsically safe input circuits Ex ia Application area acc. to ATEX : II (1) G; II (1) D Installation in zone 2 Input for Pt100 / Ni100 resistors, thermocouples and millivolt


Original
PDF IM34-11EX-CI IM34-11EX-CI Ni100/Pt100, Ni100/Pt100 2013-07-13T20 D-45472
Not Available

Abstract:
Text: thermo detectors (RTD) Ni100/ Pt100 , thermoelement types B, E, J, K, L, N, R, S and T or low voltages in , thermo detectors Ni100/ Pt100 in 2, 3 or 4-wire-technology can be operated alternatively at the input circuit of the measuring amplifier. The Ni100/ Pt100 input can either be used as external cold junction , I I I Intrinsically safe input circuits Ex ia Application area acc. to ATEX : II (1) G; II (1) D Installation in zone 2 Input for Pt100 / Ni100 resistors, thermocouples and millivolt signals


Original
PDF IM34-11Ex-Ci/24VDC M34-11Ex-Ci/24VDC Ni100/Pt100, Ni100/Pt100 2013-07-13T20 D-45472
PT100 Amplifier

Abstract:
Text: circuits Ex ia Application area acc. to ATEX : II (1) G; II (1) D Installation in zone 2 Input for Pt100 , resistance thermo detectors (RTD) Ni100/ Pt100 , thermoelement types B, E, J, K, L, N, R, S and T or low , mA. Alternatively, Ni100/ Pt100 in 2, 3 or 4-wiretechnology can be operated at the measuring amplifier's input circuit. The Ni100/ Pt100 input can either be used as external cold junction compensation , ) The signals are transformed according to ITS 90/IEC 584 for thermocouples and IEC 751 for Pt100 RTDs


Original
PDF IM34-12EX-CRI IM34-12EX-CRI Ni100/Pt100, Ni100/Pt100 2013-07-13T20 D-45472 PT100 Amplifier
Not Available

Abstract:
Text: Application area acc. to ATEX : II (1) G; II (1) D Installation in zone 2 Input for Pt100 / Ni100 resistors , thermo detectors (RTD) Ni100/ Pt100 , thermoelement types B, E, J, K, L, N, R, S and T or low voltages in , . Alternatively, Ni100/ Pt100 in 2, 3 or 4-wiretechnology can be operated at the measuring amplifier's input circuit. The Ni100/ Pt100 input can either be used as external cold junction compensation for the , / Pt100 resistor in 2, 3 or 4-wire technology I I I Measuring range, lower limit -100…- 1 °C


Original
PDF IM34-12EX-RI IM34-12EX-RI Ni100/Pt100, Ni100/Pt100 2013-07-13T20 D-45472
Not Available

Abstract:
Text: thermo detectors (RTD) Ni100/ Pt100 , thermoelement types B, E, J, K, L, N, R, S and T or low voltages in , . Resistance thermo detectors Ni100/ Pt100 in 2, 3 or 4-wire-technology can be operated alternatively at the input circuit of the measuring amplifier. The Ni100/ Pt100 input can either be used as external cold , I Type of probe Connection of the Ni100/ Pt100 resistor in 2, 3 or 4-wire technology I I , Intrinsically safe input circuits Ex ia Application area acc. to ATEX : II (1) G; II (1) D Installation in


Original
PDF IM34-11EX-I IM34-11EX-I Ni100/Pt100, Ni100/Pt100 2013-07-13T20 D-45472
2010 - Not Available

Abstract:
Text: Accuracy < 0.1°C ( Pt100 ) Configurable linearisation, damping and status indication Current-trim and , , ATEX II 1G Ex nA II T5, ATEX II 3G Description FlexTop 2221 is a 4.20 mA loop-powered , -wire connection can be selected for the resistance input. The built-in temperature sensor or a remote Pt100 , 61326 NE 21 Approval Ex ia IIC T5/T6, ATEX II 1G Supply range < 0.05°C Emission , : T6: Approval Ex ia IIC T5/T6, ATEX II 1G -40 < Tamb < 85°C -40 < Tamb < 50Â


Original
PDF Pt100) UK/2010-03-03
2006 - pt100 atex

Abstract:
Text: Approvals for explosion protection ­ intrinsically safe ATEX ­ pressure proof enclosure/flameproof ATEX ­ , connecting to systems according to: ­ Entity model ­ FISCO model Dust Ex ATEX Field mounted , blocks 2 x AI (s) 1 x RB (s) 1 x TB (c) Input Resistance Resistance thermometer n · Pt100 up , measurement > 5 k Input filter 50/60 Hz Internal reference junction Pt100 , via software switchable (no , Thermocouple type U Resistance thermometer Pt100 Resistance thermometer Pt1000 Resistance thermometer Ni100


Original
PDF TF202/TF202-Ex pt100 atex AGLF ABB Pt100 3 wire NGV220-EX agsfd Thermocouple Type K NGV220-NO Ni100 sensor Thermocouple color codes cable Ni120 sensor
Not Available

Abstract:
Text: thermo detectors (RTD) Ni100/ Pt100 , thermoelement types B, E, J, K, L, N, R, S and T or low voltages in , thermometers Ni100/ Pt100 in 2, 3 or 4-wire technology can be operated alternatively at the measuring amplifier's input circuit. The Ni100/ Pt100 input can either be used as external cold junction compensation for , -wire technology) I I I Intrinsically safe input circuits Ex ia Application area acc. to ATEX : II (1) G, II (1) D, II 3G Input for Pt100 / Ni100 resistors, thermocouples and millivolt signals in 2, 3 or 4


Original
PDF IME-TI-11Ex-Ci/24VDC IMETI-11Ex-Ci/24VDC Ni100/Pt100, Ni100/Pt100 D-45472 2013-07-13T20
Cu53 rtd

Abstract:
Text: signals between 0/4…20 mA. The special device K63 analyzes standard PT100 /NI100 acc. to IEC 751, as well as Pt100 acc. to Gost, also CU50, CU53 CU100 and CuZn100 acc.to Gost. Moreover, standard , Intrinsically safe input circuits Ex ia Application area acc. to ATEX : II (1) G; II (1) D I Installation in zone 2 I HART® I Removable terminal blocks I Connection of PT100 sensors acc , supply unit 20…250 VAC 40…70 Hz 20…125 VDC ð 3 W Input circuits Voltage input Pt100


Original
PDF IM34-12Ex-CRi/K63 IM34-12EX-CRI/K63 PT100/NI100 Pt100 CU100 CuZn100 2013-07-13T20 D-45472 Cu53 rtd PT100 IEC 751
2004 - ABB Pt100 3 wire

Abstract:
Text: and solid bus current limitation Approvals for explosion protection ­ intrinsically safe ATEX ­ , mV.+ 75 mV 2 µV Input filter 50/60 Hz Input Internal reference junction Pt100 , via , Pt100 up to Pt1000 (IEC 751: n = 0.1; 0.5; 1; 2; 5; 10) (JIS 1604: n = 0.1; 0.5; 1; 2; 10) (SAMA: n = , thermometer Pt100 Resistance thermometer Pt1000 Resistance thermometer Ni100 Resistance thermometer Ni1000 , . junction ± 0.1 K ± 40 m ± 320 m ± 0.25 K ± 50 µV ± 10 µV Pt100 DIN IEC 751 Cl. B Mechanical


Original
PDF TF02/TF02-Ex ABB Pt100 3 wire pt100 temperature sensor circuit diagram TF02 Ni100 sensor 455 3968 PT100 PT100 temperature sensor ABB PT100 ABB ABB thermocouple pt100 4 wire BUZH, Aluminum
Not Available

Abstract:
Text: detectors (RTD) Ni100/ Pt100 , thermoelement types B, E, J, K, L, N, R, S and T or low voltages in a range , detectors Ni100/ Pt100 in 2, 3 or 4-wire-technology can be operated alternatively at the input circuit of the measuring amplifier. The Ni100/ Pt100 input can either be used as external cold junction , according to ITS 90/IEC 584 for thermoelements and IEC 751 for Pt100 RTDs and provided as temperature linear signals at the current output. Installation in zone 2 Input for Pt100 / Ni100 resistors


Original
PDF IM34-11Ex-Ci/K70 IM34-11EX-CI/K70 Ni100/Pt100, Ni100/Pt100 2013-07-13T20 D-45472