Catalog Datasheet MFG & Type PDF Document Tags
2002 - Not Available

Abstract:
Text: PaceMaker 3.0, see “Insessionid Calculation Modes Possible with PaceMaker” on page 10. Stage 3 - Read , -30 Data Sheet RC header to identify the flow to the PaceMaker. The following table shows the different , Four Levels of PaceMaker†™s Hierarchical Scheduling Scheduling at the Physical Port Layer Up to 63 , €¢ Downloaded by ashukla@partminer.com on December 19, 2006 from Vitesse.com PaceMaker 3TM Packet and Cell , protection serial link to switch fabric GENERAL DESCRIPTION The PaceMaker 3.0™ ( PaceMaker ) Packet and


Original
PDF VSC2400-30 OC-48 G52427,
2002 - digital pacemaker

Abstract:
Text: PaceMaker's Scheduling Subsystem Performance The PaceMaker 3.0 implements, among other algorithms, the The PaceMaker 3.0TM is a highly integrated theoretically proven optimal EDF traffic management , TRAFFIC MANAGEMENT FAMILY PaceMaker 3.0 TM PaceMaker 3.0TM (VSC2400-30) OC-48 Traffic , A P P L I C AT I O N S : !Pin-compatible with Vitesse PaceMaker 2.5 and OSCAR Complete , /frame/packet traffic PB-VSC2400-30-001 PaceMaker 3.0 TM PaceMaker 3.0TM (VSC2400-30) OC


Original
PDF VSC2400-30) OC-48 VSC2400-30UY OC-48 digital pacemaker pacemaker VSC2400-30 VSC2400-30UY
2002 - pacemaker

Abstract:
Text: PaceMaker's Scheduling Subsystem Performance The PaceMaker 3.0 implements, among other algorithms, the The PaceMaker 3.0TM is a highly integrated theoretically proven optimal EDF traffic management , TRAFFIC MANAGEMENT FAMILY PaceMaker 3.0 TM PaceMaker 3.0TM (VSC2400-30) OC-48 Traffic , A P P L I C AT I O N S : 4Pin-compatible with Vitesse PaceMaker 2.5 and OSCAR Complete , /frame/packet traffic PB-VSC2400-30-001 PaceMaker 3.0 TM PaceMaker 3.0TM (VSC2400-30) OC


Original
PDF VSC2400-30) OC-48 4OC-48 VSC2400-30UY OC-48 pacemaker PB-VSC2400-30-001 VSC2400-30 VSC2400-30UY
2000 - pacemaker

Abstract:
Text: PaceMaker 2.4TM OC-48 Traffic Management Engine Traffic Management Family Product Brief A New Level of Feature Integration and Performance The PaceMaker 2.4TM is a highly integrated cell , packet discard/Partial packet discard GFR service for cell/frame/packet traffic The PaceMaker 2.4 , provides new capabilities in traffic congestion management. The PaceMaker 2.4 also supports an , Internet infrastructure, PaceMaker 2.4 was developed to provide new QoS and Class of Service (CoS


Original
PDF OC-48 OC-48c pacemaker AAL5 SAR traffic heart rate monitor
2000 - IBM motherboard schematics

Abstract:
Text: PaceMaker 2.4 Evaluation SystemTM Product Brief Traffic Management Family Features: · Full Capacity OC-48 Packet and Cell Traffic Evaluation Platform · Complete PaceMaker 2.4TM , -based Development Platform with PCI PaceMaker 2.4 Engine and PHY Cards · Targeted at the "User" Environment , " development project schedule. The PaceMaker 2.4 Evaluation System provides a complete, full-capacity OC , applications. · The system is targeted to allow users to evaluate the functions of the PaceMaker 2.4TM


Original
PDF OC-48 604-based IBM motherboard schematics pacemaker pc motherboard schematics IBM powerpc motherboard schematics embedded system projects free VITESSE IBM PC AT schematics MPC860
2002 - pacemaker

Abstract:
Text: TRAFFIC MANAGEMENT FAMILY PaceMaker 2.5 TM Evaluation System PaceMaker 2.5 Evaluation , Traffic Management Evaluation Platform Improve Time to Market The PaceMaker 2.5 Evaluation SystemTM , high-speed packet switching and routing applications. 4Complete PaceMaker 2.5TM Reference Design , PaceMaker 2.5 Engine and PHY Cards 4Targeted at the "User" Environment 4Provides Ready-to-go Platform for , Packaging BENEFITS: 4Allows "Full Capacity" Testing and Evaluation of the PaceMaker 2.5 Functionality


Original
PDF VSC2940-25) OC-48 604-based pacemaker MTX-604 IBM motherboard schematics motorola ic 741 PC MOTHERBOARD SERVICE MANUAL VSC2940-25
2001 - pacemaker

Abstract:
Text: data www.vitesse.com PaceMaker's Scheduling Subsystem The PaceMaker 2.5 implements the , PaceMaker 2.5TM (VSC2400-25) OC-48 Traffic Management and SAR Engine Traffic Management Family , PaceMaker 2.5TM is a highly integrated cell and packet processing engine that integrates a number of common functions found inside today's high-speed networking equipment. PaceMaker 2.5, with its , PaceMaker 2.5 also supports an unrestricted number of multicast leaves, VC merging, and label swapping


Original
PDF VSC2400-25) OC-48 pacemaker digital pacemaker VSC2400-25 VSC2400-25UY
2002 - Not Available

Abstract:
Text: PaceMaker supports up to 64 physical ports. Figure 6. The Four Levels of PaceMaker†™s Hierarchical , Modes Possible with PaceMaker” on page 10. Stage 3 - Read Session Control Block (RSCB) module at , RC header to identify the flow to the PaceMaker. The following table shows the different insessionid , VSC2400-30 Data Sheet PaceMaker 3TM Packet and Cell Management Engine • Overall â , protection serial link to switch fabric GENERAL DESCRIPTION The PaceMaker 3.0™ ( PaceMaker ) Packet and


Original
PDF VSC2400-30 OC-48 G52427,
2002 - AAL5 SAR

Abstract:
Text: for the Internet infrastructure, PaceMaker products were developed to provide new QoS and Class of , highly successful PaceMaker 2.5, OSCAR is designed to allow customers to drive down costs and maximize , and PaceMaker : PaceMaker and OSCAR are designed to be used side-by-side in multiservice line cards , . PaceMaker would be used to manage egress flows to the network. Egress flows would typically require SAR as well as queue / buffer management, per-flow shaping and per-flow scheduling. With OSCAR and PaceMaker


Original
PDF VSC2401-25) OC-48 AAL5 SAR pacemaker pacemaker cross reference VSC2401-25
2010 - cardiac pacemaker

Abstract:
Text: processing power can be used to implement adaptive filtering, pacemaker detection, and ECG signal analysis , from muscle contraction), noise, and interference due to electrode movement, as well as pacemaker detection. It can be advantageous to implement a programmable pacemaker detection scheme with Blackfin rather than use a dedicated circuit in order to allow detection enhancements to keep pace with pacemaker evolution. While pacemaker detection has become a necessary feature in clinical and portable ECG devices in


Original
PDF ADSP-BF50x cardiac pacemaker defibrillator AED Defibrillator portable ECG ECG book ekg op amp digital pacemaker pacemaker AD7766 holter monitor
baby monitor circuit

Abstract:
Text: pacemaker was implanted. The rest is history. most common being pacemakers , with around 150,000 , stimulating the heart to beat was considered lunacy in 1930 when the first external pacemaker required AC , . The average recipient of a pacemaker is 70 years old. "Baby Boomers" who are now middle age will be


Original
PDF MED426 baby monitor circuit mems pacemaker pacemaker TVS Transient Voltage Suppressors implantable pumps implantable implantable medical device SA04 tvs array bare die
2008 - pacemaker

Abstract:
Text: -50061 for implantable cardiac pacemakers. When the voltage between the terminals rises to a dangerous , devices for triple-chamber pacemakers The ZL70271 is a five-terminal devices for dual-chamber pacemakers The ZL70273 is a six-terminal device optimized for size critical applications The ZL70272 is a , applications requirements Very small size supports trend for miniaturization Applications Pacemakers , APPLICATION Implantable medical electronics, such as pacemakers , ICDs, neurostimulators and bladder control


Original
PDF ZL70271/72/73/74/88 ZL70271, ZL70272, ZL70273, ZL70274 ZL70288 EN-45502 EN-50061 pacemaker digital pacemaker EN-45502 cardiac pacemaker ZL70271 EN50061 ZL70272 differential used in medical devices implantable device protect circuit ASIX Electronics
2006 - the circuit diagram of pacemaker

Abstract:
Text: regulations EN-45502, "Active implantable" and the EN50061 "Safety of Implantable Cardiac Pacemakers". 1.1 , 6, each of the dual chamber pacemaker's terminals and case are connected to a terminal on the , connected to the case of the pacemaker. For ZL70008/9, we recommend that the case be connected to T3 of the , wafer number 100% burn-in capability Applications · · Pacemakers , Implantable Cardioverter , protection to the pacemaker chip. In actuality, the voltages and currents the implanted device is subjected


Original
PDF ZL70002/08/09/10 EN-45502 EN50061 ZL70002/UDJ ZL70008/UDJ ZL70009/UDJ ZL70010/UDJ ZL70002/08/09/10 MIL-PRF-38535 the circuit diagram of pacemaker cardiac pacemaker digital pacemaker DIODE T4 pacemaker ZL70002 ZL70010
2003 - the circuit diagram of pacemaker

Abstract:
Text: regulations EN-45502, "Active implantable" and the EN50061 "Safety of Implantable Cardiac Pacemakers". 1.1 , 6, each of the dual chamber pacemaker's terminals and case are connected to a terminal on the , connected to the case of the pacemaker. For ZL70008/9, we recommend that the case be connected to T3 of the , wafer number 100% burn-in capability Applications · · Pacemakers , Implantable Cardioverter , protection to the pacemaker chip. In actuality, the voltages and currents the implanted device is subjected


Original
PDF ZL70002/08/09/10 EN-45502 EN50061 ZL70002/UDJ ZL70008/UDJ ZL70009/UDJ ZL70010/UDJ ZL70002/08/09/10 MIL-PRF-38535 the circuit diagram of pacemaker DIODE T5 digital pacemaker implantable medical device DIODE T4 zener t5 ZL70010 cardiac pacemaker pacemaker
2001 - the circuit diagram of pacemaker

Abstract:
Text: -45502, "Active implantable" and the EN50061 "Safety of Implantable Cardiac Pacemakers". 1.1 ZL70010 , described in EN-50061. In the application example shown in Figure 6, each of the dual chamber pacemaker's , surge protection terminal connected to the case of the pacemaker. For ZL70008/9, we recommend that the , lot and wafer number 100% burn-in capability Applications · · Pacemakers , Implantable , the voltage. This provides an effective means of protection to the pacemaker chip. In actuality, the


Original
PDF ZL70002/08/09/10 DS5666 EN-45502 EN50061 ZL70002/UDJ ZL70008/UDJ ZL70009/UDJ ZL70010/UDJ ZL70002/08/09/10 MIL-PRF-38535 the circuit diagram of pacemaker cardiac pacemaker A 4714 8 PIN UM 92 diode digital pacemaker pacemaker ZL70010
pacemaker

Abstract:
Text: regulations EN-45502, "Active implantable" and the EN50061 "Safety of Implantable Cardiac Pacemakers". 1.1 , 6, each of the dual chamber pacemaker's terminals and case are connected to a terminal on the , connected to the case of the pacemaker. For ZL70008/9, we recommend that the case be connected to T3 of the , wafer number 100% burn-in capability Applications · · Pacemakers , Implantable Cardioverter , protection to the pacemaker chip. In actuality, the voltages and currents the implanted device is subjected


Original
PDF ZL70002/08/09/10 EN-45502 EN50061 ZL70002/UDJ ZL70008/UDJ ZL70009/UDJ ZL70010/UDJ ZL70002/08/09/10 MIL-PRF-38535 pacemaker digital pacemaker the circuit diagram of pacemaker cardiac pacemaker
ZL70081

Abstract:
Text: equipment Implanted Medical Devices (IMD) such as cardiac pacemakers , implantable cardioverter , Deep brain stimulation Stimulatory Devices ­ Pacemaker ­ Implantable Cardioverter/Defibrillator , stimulation Defibrillator Cardiac pacemaker Heart Sensor Drug delivery/ Insulin pump Bladder , Cardiologist with Programmer Patient with Pacemaker / ICD Home Monitoring [Page 5] Transfer to , size Reasonable data rates - Pacemaker applications >20 kbps and higher projected in the future


Original
PDF ZL70100: ZL70081: ZL70262: mid-1990s, ZL70081 low cost hearing aid circuit diagram circuit diagram of pill camera circuit diagram of digital hearing aid insulin pump circuit diagram cardiac pacemaker 0.18-um CMOS technology characteristics Hearing Aid Circuit Diagram circuit diagram of low cost hearing aid hearing aid chip
2001 - the circuit diagram of pacemaker

Abstract:
Text: -45502, "Active implantable" and the EN50061 "Safety of Implantable Cardiac Pacemakers". 1.1 ZL70010 , described in EN-50061. In the application example shown in Figure 6, each of the dual chamber pacemaker's , surge protection terminal connected to the case of the pacemaker. For ZL70008/9, we recommend that the , and wafer number 100% burn-in capability Applications · · Pacemakers , Implantable , the voltage. This provides an effective means of protection to the pacemaker chip. In actuality, the


Original
PDF ZL70002/08/09/10 DS5666 EN-45502 EN50061 ZL70002UDJ ZL70008UDJ ZL70009UDJ ZL70010UDJ ZL70002/08/09/10 MIL-PRF-38535 the circuit diagram of pacemaker cardiac pacemaker pacemaker ZL0008 diac terminals EN-50061 digital pacemaker zener diode t5 EN50061
2002 - the circuit diagram of pacemaker

Abstract:
Text: -45502, "Active implantable" and the EN50061 "Safety of Implantable Cardiac Pacemakers". 1.1 ZL70010 , described in EN-50061. In the application example shown in Figure 6, each of the dual chamber pacemaker's , surge protection terminal connected to the case of the pacemaker. For ZL70008/9, we recommend that the , lot and wafer number 100% burn-in capability Applications · · Pacemakers , Implantable , the voltage. This provides an effective means of protection to the pacemaker chip. In actuality, the


Original
PDF ZL70002/08/09/10 DS5666 EN-45502 EN50061 ZL70002/UDJ ZL70008/UDJ ZL70009/UDJ ZL70010/UDJ ZL70002/08/09/10 MIL-PRF-38535 the circuit diagram of pacemaker cardiac pacemaker DIODE T5 pacemaker ZL70010
2003 - EN50061

Abstract:
Text: active implantable medical devices, and EN-50061 for implantable cardiac pacemakers. Surge Protection , ZL70002 is a seven-terminal device for triplechamber pacemakers The ZL70008 and ZL70009 are five-terminal devices for dual-chamber pacemakers The ZL70010 is a six-terminal device optimized for size critical , Glance Package: Solder bumped die Sample Availability: Now Applications Pacemakers Implantable , PROTECTION DEVICES ULTRA LOW POWER RF Implantable medical electronics, such as pacemakers , ICDs


Original
PDF ZL70002 ZL70009 100ns) ZLTM70002, ZL70008, ZL70009, ZL70010 ZL70204 EN-45502 EN-50061 EN50061 cardiac pacemaker implantable medical device
2014 - cardiac pacemaker

Abstract:
Text: not pose a significant health problem for most pacemaker wearers. However, people with pacemakers may , . 8 Interference with Pacemakers and Other Medical Devices , . 9 Precautions for pacemaker wearers , où l'équipement médical peut être utilisé. Interference with Pacemakers and Other Medical , method to measure EMI of implanted cardiac pacemakers and defibrillators from cellular devices. This


Original
PDF S000570, cardiac pacemaker
implants

Abstract:
Text: we're helping heart patients to avoid premature pacemaker replacement by protecting delicate pacemaker circuitry from www. .com Manuel Lynch Corporate Director of Worldwide Marketing and


Original
PDF
pacemaker

Abstract:
Text: requirements for RF SiP in Pacemakers Zarlink's embedded component research projects Review of other embedded , Pacemaker CONFIDENTIAL Examples Diseases and Implants Implantable electronic devices treat these conditions: ­ Profound Deafness Cochlear Implant ­ Heart conditions Pacemakers ­ Diabetes Insulin pumps ­ Paralysis Stroke victims "Dropped Foot Implant" [Page 6] CONFIDENTIAL Pacemakers Pacemakers dominate the implant market It is the most effective was to treat arrythmia Relatively young


Original
PDF
2013 - ZL70572

Abstract:
Text: -45502, "Active Implantable" and EN-50061, "Safety of Implantable Cardiac Pacemakers". R e vis i on 13 1-1 , described in EN-50061. In the application example shown in Figure 2-1, each of the dual chamber pacemaker's , surge protection terminal connected to the case of the pacemaker. For ZL70571/72, it is recommended , Capability – Lot Acceptance Testing (LAT) Included • Pacemakers and Neurostimulators â , . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I Figure 2-1 • Pacemaker


Original
PDF ZL70571/72/73/74/88 ZL70588 EN-45502 EN-50061 MIL-PRF-38535 ZL70571UDJ ZL7057x-DS/107092-13/4 ZL70572
2012 - Not Available

Abstract:
Text: -45502, "Active Implantable" and EN-50061, "Safety of Implantable Cardiac Pacemakers". R e vis i on 12 1-1 , described in EN-50061. In the application example shown in Figure 2-1, each of the dual chamber pacemaker's , surge protection terminal connected to the case of the pacemaker. For ZL70571/72, it is recommended , Capability – Lot Acceptance Testing (LAT) Included • Pacemakers and Neurostimulators â , . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I Figure 2-1 • Pacemaker


Original
PDF ZL70571/72/73/74/88 ZL70588 EN-45502 EN-50061 MIL-PRF-38535 ZL70571UDJ ZL7057x-DS/107092-12/4