Part Manufacturer Description Datasheet Download Buy Part
RH1034MW-1.2 Linear Technology Micropower Dual Reference
LTC1258CMS8 Linear Technology IC 1-OUTPUT THREE TERM VOLTAGE REFERENCE, 2.385 V, PDSO8, PLASTIC, MSOP-8, Voltage Reference
LT1019CN-10 Linear Technology IC 1-OUTPUT THREE TERM VOLTAGE REFERENCE, 10 V, PDIP, Voltage Reference
LT1019IS-10 Linear Technology IC 1-OUTPUT THREE TERM VOLTAGE REFERENCE, 10 V, PDSO, Voltage Reference
LT1021BIN-5 Linear Technology IC 1-OUTPUT THREE TERM VOLTAGE REFERENCE, 5 V, PDIP, Voltage Reference
LT1021CIN-10 Linear Technology IC 1-OUTPUT THREE TERM VOLTAGE REFERENCE, 10 V, PDIP, Voltage Reference

omron limit switch cross reference Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
2011 - omron limit switch cross reference

Abstract: D4E-2C10N D4EN vctf 0.75 1H-10 3M Touch Systems
Text: ( ) : Reference Value (57) 18 Cross Roller Plunger D4E-1B00N D4E-2B00N D4E-1B10N D4E-2B10N 3.5 PT , ) 31.4±0.8 mm ( ) : Reference Value (60) M12 × 1 18 Cross Roller Plunger D4E-1B20N *1 D4E , ) 41.3±0.8 mm ( ) : Reference Value (60) M12 × 1 18 Sealed Cross Roller Plunger D4E-1E20N *1 PT , current 1.5 to 2 times the rated current to the Limit Switch in series in order to protect the Limit Switch from damage due to short-circuiting. When using the Limit under the EN ratings, use a gI or gG 10


Original
PDF
omron limit switch cross reference

Abstract: OMRON switch Cross Reference D4E-1C20N D4E-1E20N limit switch, long cross roller plunger 3M Touch Systems 2h00
Text: parentheses are reference values. (60) M12 x 1 18 Small Sealed Switch D4E-@N 143 Cross , ( reference (0.3 mm) value) OP 28.4 4.2+0.2 0 21.5 16 dia. (57) 146 Small Sealed Switch , with a breaking current 1.5 to 2 times the rated current to the Limit Switch in series in order to protect the Limit Switch from damage due to short-circuiting. When using the Limit under the EN ratings , precision of the Limit Switch . Make sure that the shape of the cam is smooth enough. Check that OT has a


Original
PDF omron247 X019-E1-07. omron limit switch cross reference OMRON switch Cross Reference D4E-1C20N D4E-1E20N limit switch, long cross roller plunger 3M Touch Systems 2h00
2008 - omron limit switch cross reference

Abstract: omron d4e 2A10N D4E-1C20N OMRON switch Cross Reference D4E-1A23L2N EN60947-5-1 d4e-2b20n gb14048.5 D4E-2D20N
Text: 2 times the rated current to the Limit Switch in series in order to protect the Limit Switch from , on the service life and precision of the Limit Switch . Make sure that the shape of the cam is , Small Sealed Switch D4E-@N CSM_D4E-_N_DS_E_3_1 Slim and Compact Switch with Better Seal , switch ensure smooth snap action and long life expectancy. · Protection cover protects the built-in switch from dust and oil. Plunger incorporates a tough seal cap that lasts for a long time. · One touch


Original
PDF
2007 - vctf cable

Abstract: omron limit switch cross reference 2c21* RELAY film hot 2F21 D4E-1E20N D4E-1C20N vctf 0.75 wire cable OMRON 250v relay ac 11 pin D4E-1F20N
Text: other location where the Limit Switch is exposed to special machining oil. Consult your OMRON , breaking current 1.5 to 2 times the rated current to the Limit Switch in series in order to protect the Limit Switch from damage due to short-circuiting. When using the Limit under the EN ratings, use a gI , overtravel (OT) have significant effect on the service life and precision of the Limit Switch . Make sure , ://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. 10 Precautions for All Limit


Original
PDF
2007 - welding machine wiring diagram

Abstract: g9sx-BC202 G9SX-AD322-T15 hot air gun fan controller circuit s34 zener diode g9sx-bc 24vdc motor forward reverse control diagram varistor S14 k1 IEC/EN 60947-5-1 OMRON RELAY Cross Reference
Text: Switching 2. Safety Door Switch 2. Cover 3. Conveyor cart 4. Mode selector 3. Safety Limit , G9SX-AD322-T15 (24 VDC) (2-channel Safety Limit Switch Input / Auto Reset) Feedback Loop 11 12 KM1 21 , L1 L2 X1 X2 KM1 KM2 Emergency Stop Switch Reset Switch Safety Limit Switch , enable easier system expansion. Logical AND connections simplify adding safety switch inputs. (c)Copyright OMRON Corporation 2007 All Rights Reserved. 1 G9SX Applications Parts


Original
PDF IEC/EN61508 EN954-1 welding machine wiring diagram g9sx-BC202 G9SX-AD322-T15 hot air gun fan controller circuit s34 zener diode g9sx-bc 24vdc motor forward reverse control diagram varistor S14 k1 IEC/EN 60947-5-1 OMRON RELAY Cross Reference
2000 - ALPS SKHCAC

Abstract: alps switch Tactile Switch Cross Reference ALPS relay cross reference EVQ-23407 TACTILE SWITCH PLA relay SKHVBD OMRON switch Cross Reference SKHUBB
Text: Cross Reference E Switch Part Number Omron Part Number TL-1100-D-F160-Q TL-1100-D-F260-Q TL , Switch Cross Reference E Switch Part Number Omron Part Number TLE-1105-F-F100-Q TLE , Switch Cross Reference ITT Canon ITT Canon Part Number Omron Part Number Cross Type Major , Reference Tactile Switch Cross Reference Panasonic Panasonic Part Number Omron Part Number , type of switch Tactile Switch Cross Reference ALPS Tactile Switch Cross Reference ALPS Part


Original
PDF 1/00/1M ALPS SKHCAC alps switch Tactile Switch Cross Reference ALPS relay cross reference EVQ-23407 TACTILE SWITCH PLA relay SKHVBD OMRON switch Cross Reference SKHUBB
IEC-947-5-1

Abstract: IEC947-5-1 E76675 IEC947 LR45746 nema B300 IEC947-51 vctf cable D4C-1620 D4C-1610
Text: D4C D4C Slim Enclosed Limit Switches D4C Sealed, Compact, Slim Prewired Limit Switch , (inch) D4C- 03 Cross Roller Plunger Switch D4C- 33 Sealed Cross Roller Plunger Switch D4C , service life and precision of a limit switch . For this reason, the cam angle should be 30° max. The , cable s Ordering Information s LIMIT SWITCHES Actuator 3 m (9.8 ft) cable 5 m (16.4 ft , -1731 Roller plunger D4C-1602 D4C-1702 Sealed roller plunger D4C-1632 D4C-1732 Cross roller


Original
PDF D4C-1601 D4C-1701 D4C-1631 D4C-1731 D4C-1602 D4C-1702 D4C-1632 D4C-1732 D4C-1603 D4C-1703 IEC-947-5-1 IEC947-5-1 E76675 IEC947 LR45746 nema B300 IEC947-51 vctf cable D4C-1620 D4C-1610
tt 3043

Abstract: equivalent transistor TT 3043 y96E-44SA D4CC-1041 D4CC-1024 D4CC-1010 D4CC-1003 D4CC-1002 D4CC-1001 pt 2399
Text: D4CC D4CC Slim Connector-Ready Limit Switches D4CC Compact, Enclosed Limit Switch , service life and precision of a D4CC Limit Switch . For this reason, the dog angle must be 30° max.; the , Limit Switch with a tightening torque of 3.5 to 4.5 kg·cm (2.4 to 3.1 in·lbs) after changing the , D4CC is a SPDT limit switch for standard loads. The WLA_ cannot be replaced with a D4CC Limit Switch , Plates. Refer to the following figure to set the stroke of a D4CC Limit Switch mounted on a panel


Original
PDF D4CC-1001 D4CC-3001 D4CC-1002 D4CC-3002 D4CC-1003 D4CC-3003 D4CC-1010 D4CC-3010 D4CC-1024 D4CC-3024 tt 3043 equivalent transistor TT 3043 y96E-44SA D4CC-1041 D4CC-1024 D4CC-1010 D4CC-1003 D4CC-1002 D4CC-1001 pt 2399
OMRON DIP switch

Abstract: 219-2MST 218-4LPST OMRON switch Cross Reference 90HBW08S 209-6LPST relay cross reference AN 7104 218-10LPST diode cross reference
Text: Omron does not produce that type of DIP switch CTS Cross Reference CTS Part Number OMRON Part , 195-9MS A6ER-9104 S 4 Cross Type CTS Cross Reference CTS Part Number OMRON Part , CTS Cross Reference CTS Part Number OMRON Part Number 209-4MST A6T-4104 S 209-6LPST , 6 Cross Type Grayhill Cross Reference Grayhill Part Number OMRON Part Number 94HCB10 , Cross Type Grayhill Cross Reference Grayhill Part Number OMRON Part Number 76PSB07 A6ER


Original
PDF DBW10S A6S-0102 90B02S A6T-2102 90B04S A6T-4102 90B06S A6T-6102 90B08S A6T-8102 OMRON DIP switch 219-2MST 218-4LPST OMRON switch Cross Reference 90HBW08S 209-6LPST relay cross reference AN 7104 218-10LPST diode cross reference
EXW516M

Abstract: WLF5H12-F Polyvinyl Chloride PVC
Text: Miniature Explosion-proof Limit Switch WLF5-F Miniature Limit Switch Boasting Rigid , and Cautions ! ! WARNING WARNING Note: The Explosion-proof Limit Switch must be , not damage the covering of the cable connected to the Explosion-proof Limit Switch , otherwise the , Safety Precautions Do not apply electric current to the Explosion-proof Limit Switch while wiring. Do not touch the charged parts of the Explosion-proof Limit Switch or the wires of the cable connected


Original
PDF WLF5H12-F WLF5H12-F C105-E1-1 0696-1M EXW516M Polyvinyl Chloride PVC
switch omron

Abstract: 5 pin DC CROSS ARM ZE-NRN
Text: -2S Cross Roller Plunger Switch PT D-76 ZE/ZV/ZV2 Unit: mm (inch) omRon Z E/Z V /Z V 2 , omRon Enclosed Limit Switches Large Switching Capacity and Long Service Life 15-amp, 125 VAC , -77 ZE/ZV/ZV2 ZE-N22-2S Sealed Roller Plunger Switch omRon ZE/ZV/ZV2 ' S ta in le ss s te e l roller ZE-N21-2S Sealed Cross Roller Plunger Switch ' S tainle ss 6teet roller ZE-NA2-2S Sealed Roller Arm Lever Switch Limit Switches 10.1 dia. x 7.9 (0.75 dia. *0.31) ZE-NCL-2S Sealed Rod Lever


OCR Scan
PDF 15-amp, ZE-Q22-2S ZE-Q21-2S ------------------------------ZE-QA277-2S ZE-NA277-2S switch omron 5 pin DC CROSS ARM ZE-NRN
G9SX-BC202

Abstract: automatic 3 phase changer T11T12 T21T22 transistor s34 block diagram of plc s7 plc wiring diagram s7 200 G9SX-BC202-RT 6 channel relay to control robot preset switch KM6 II
Text: switch Limit switch Use approved devices with Direct Opening Mechanism complying with IEC/EN , Emergency Stop Switch is pressed, the entire machine will stop. · When a door is open, the corresponding part will not activate. Emergency Stop Switch Tool changer door Main Door Pallet Changer , EI ERR Safety Door Switch No. Basic Unit G9SX-BC T21 T22 X2 S14 S24 L1 A2 L2 Safety Door Switch Safety Door Switch Logical connection T31 T32 T33 T11 T12 Y1 X1 X2


Original
PDF IEC/EN61508 EN954-1 J150-E1-04 75-344-7093/Fax: G9SX-BC202 automatic 3 phase changer T11T12 T21T22 transistor s34 block diagram of plc s7 plc wiring diagram s7 200 G9SX-BC202-RT 6 channel relay to control robot preset switch KM6 II
1999 - IEC947-5-1

Abstract: IEC-947-5-1 E76675 IEC947 IEC947 en60947 Switches vctf cable D4C-1602 D4C-1603 D4C-1610 D4C-1632
Text: Slim Enclosed Limit Switches D4C Sealed, Compact, Slim Prewired Limit Switch s s s s s , ) EN60947-1 Dimensions Unit: mm (inch) s LIMIT SWITCHES D4C- 4 01 Pin Plunger Switch D4C , Roller Plunger Switch 5 D4C D4C Unit: mm (inch) D4C- 03 Cross Roller Plunger Switch D4C- 33 Sealed Cross Roller Plunger Switch D4C- 10 Bevel Plunger Switch 6 D4C D4C , , and overtravel have a significant effect on the service life and precision of a limit switch . For


Original
PDF D4C-1601 D4C-1701 D4C-1631 D4C-1731 D4C-1602 D4C-1702 D4C-1632 D4C-1732 D4C-1603 D4C-1703 IEC947-5-1 IEC-947-5-1 E76675 IEC947 IEC947 en60947 Switches vctf cable D4C-1602 D4C-1603 D4C-1610 D4C-1632
2007 - din en iso 13855

Abstract: welding machine wiring diagram manual welding machine wiring diagram iron EI core OMRON plc programming manual IEC/EN 60947-5-1 G9SX-BC202 IEC 60947-5-1 limit switch KM A1 G9SX-GS226-T15-RC hot air gun fan controller circuit
Text: ://www.ia.omron.com/ Limit Switch (c)Copyright OMRON Corporation 2007 All Rights Reserved. 1 G9SX-GS , Door Switch monitors the opening and closing of the door during normal operation. · The Limit , operating mode: Door Switch monitors the door. Maintenance mode: Limit Switch monitors the hazard source , Manual Switching Function 2. Safety Door Switch 2. Cover 3. Conveyor cart 3. Safety Limit , Limit Switch D4F Safety output 4. Mode selector 1. Emergency Stop Switch Programmable


Original
PDF
2013 - Not Available

Abstract: No abstract text available
Text: Inductive Coupler F92A CSM_F92A_DS_E_5_1 Transmit Limit Switch ON/OFF Signals without , electromagnetically coupled. When the F92A coil forms a closed loop (when the detecting side limit switch is in the , there is no need to consider the lead wire color (brown/blue). B 8 6 4 Switch ON OFF , will be detected even if switch is open. Operating Principle The Coupler transmits ON/OFF signals , — Designing • Make sure to use a connecting switch suitable for microloads. • Use a connecting switch


Original
PDF
1999 - D4CC-3001

Abstract: No abstract text available
Text: Slim Connector-Ready Limit Switches D4CC Compact, Enclosed Limit Switch s s s s s s , the service life and precision of a D4CC Limit Switch . For this reason, the dog angle must be 30 , . Secure the head of a D4CC Limit Switch with a tightening torque of 3.5 to 4.5 kg•cm (2.4 to 3.1 , SPECIAL MOUNTING PLATE The D4CC is a SPDT limit switch for standard loads. The WLA_ cannot be replaced with a D4CC Limit Switch since the WLA_ contacts are normally open. There is no difference in


Original
PDF D4CC-1001 D4CC-3001 D4CC-1002 D4CC-3002 D4CC-1003 D4CC-3003 D4CC-1010 D4CC-3010 D4CC-1024 D4CC-3024 D4CC-3001
2010 - welding machine wiring diagram

Abstract: din en iso 13855 G9SX-GS226-T15-RC welding machine wiring diagram manual T71-T72 G9SX-GS226-T15-RT G9SX-BC202 welding machine transformer wiring diagram G9SX-GS226-T15 automatic brake failure indicator
Text: Switching Function During normal operation. During maintenance. · The Limit Switch monitors the , . operate while the door is closed. Door Switch Limit Switch 1 G9SX-GS With the G9SX-GS , monitors the door. Maintenance mode: Limit Switch monitors the hazard source. A safe area is ensured , Limit Switch 1. Emergency Stop Switch A22E Safety Door Switch D4NS Basic Unit G9SX-BC Safety Limit Switch D4F Safety output 4. Mode selector 1. Emergency Stop Switch The


Original
PDF
2007 - Z-15GW22-B

Abstract: Z-01H-B z-15hw24-b Z-15eW22-B diode zener Z -15H omron limit switch cross reference Z-15G Z-15G-B Z-15GD Z-15GD-B
Text: OMRON Corporation 2007 All Rights Reserved. 10 Z Panel Mount Cross Roller Plunger Z-15GQ21-B Z , General-purpose Basic Switch Z Best-selling Basic Switch Boasting High Precision and Wide , type is identical in construction to the general-purpose basic switch except that it has two pairs of , switching is ensured if the model is used as a twin-contact switch . Maintained-contact Models · The maintained-contact type has a reset button at the bottom of the switch case, in addition to the pushbutton (plunger


Original
PDF
2007 - omron limit switch cross reference

Abstract: welding machine wiring diagram A-20G-B dc welding machine circuit diagram metal film fused resistor 47 A-20GD-B A-20GQ-B A20GV21B A20GQ22B
Text: switch burnout may result. http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights , the switch , use a contact protection circuit to limit arcing and remove the source of the silicon gas , General-purpose Basic Switch A High-capacity Switch Capable of Handling 20 A Loads with Large Inrush Currents Same shape as OMRON Z Basic Switches except in pin plunger position, yet endures , : Pin plunger : Short spring plunger : Panel mount plunger : Panel mount cross roller plunger


Original
PDF -20G-B -20GD -20GD-B -20GQ -20GQ-B -20GQ22 -20GQ22-B -20GQ21-B omron limit switch cross reference welding machine wiring diagram A-20G-B dc welding machine circuit diagram metal film fused resistor 47 A-20GD-B A-20GQ-B A20GV21B A20GQ22B
2009 - jis c 8201-5-1

Abstract: EN60947-5-1 omron limit switch cross reference GB14048 D 4203D D4F omron zb omron D4F-120-1R D4F-220-3R EN81
Text: Small Safety Limit Switch D4F CSM_D4F_DS_E_3_1 Smallest Class of Safety Limit Switches in , certification. · The world's smallest limit switch with a direct opening mechanism (four-contact construction model). · High-sensitivity safety limit switch . · Built-in switches with two- or four-contact , Information List of Models Safety Limit Switches (with Direct Opening Mechanism) Consult with your OMRON , ), and CCC Be sure to read the "Safety Precautions" on page 6 and the "Precautions for All Safety Limit


Original
PDF EN60947-5-1) jis c 8201-5-1 EN60947-5-1 omron limit switch cross reference GB14048 D 4203D D4F omron zb omron D4F-120-1R D4F-220-3R EN81
light following robot diagram

Abstract: g9sx-BC202 IEC/EN 60947-5-1 IEC 60947-5-1 limit switch KM A1 EN60204-1 welding machine wiring diagram PFP-M EN61508 circuit diagram of door lock system mos fet marking k1
Text: switch Limit switch Use approved devices with Direct Opening Mechanism complying with IEC/EN , Switch Input / Manual Reset) + G9SX-AD322-T15 (24 VDC) (2-channel Safety Limit Switch Input / Auto Reset , limit switch S4: Limit switch Safety limit switch S3 Limit switch S4 KM3 to KM6: Contactor M2 , -channel Safety Limit Switch Inputs / Manual Reset) Lock release signal KM1 (See note 2.) KM2 KM6 S2 , etc. Timing chart GND Motor controller (Operation command) S1: Safety limit switch KM6


Original
PDF EN954-1 IEC/EN61508 J150-E2-01 NL-2132 light following robot diagram g9sx-BC202 IEC/EN 60947-5-1 IEC 60947-5-1 limit switch KM A1 EN60204-1 welding machine wiring diagram PFP-M EN61508 circuit diagram of door lock system mos fet marking k1
z-15hw24-b

Abstract: Z-15G Z-15GD Z-15GQ Z-15GW Z-15GW22 Z-15GK355-B Z-15GQ55-B
Text: rubbers are available from OMRON . When the rod is fully swung, the switch may operate when the lever , GENERAL PURPOSE Basic Switch Z General Purpose Basic Switch High precision basic switch , roller lever Hinge roller lever Unidirectional short hinge roller lever Panel mount cross , plunger Short spring plunger Panel mount plunger Panel mount roller plunger Panel mount cross roller , mount roller plunger Panel mount cross roller plunger Hinge lever Short hinge roller lever Hinge


Original
PDF 1-800-55-OMRON z-15hw24-b Z-15G Z-15GD Z-15GQ Z-15GW Z-15GW22 Z-15GK355-B Z-15GQ55-B
Z-15HNJ55-B

Abstract: Z-15G Z-15HNJS55-B Z-15GW22-B omron MH z-15gd55-b Z-15GW22 Z-15GW Z-15GQ Z-15GD
Text: rubbers are available from OMRON . When the rod is fully swung, the switch may operate when the lever , GENERAL PURPOSE Basic Switch Z General Purpose Basic Switch High precision basic switch , roller lever Hinge roller lever Unidirectional short hinge roller lever Panel mount cross , plunger Short spring plunger Panel mount plunger Panel mount roller plunger Panel mount cross roller , mount roller plunger Panel mount cross roller plunger Hinge lever Short hinge roller lever Hinge


Original
PDF NL-2132 2356-81-300/Fax: 847-843-7900/Fax: 835-3011/Fax: Z-15HNJ55-B Z-15G Z-15HNJS55-B Z-15GW22-B omron MH z-15gd55-b Z-15GW22 Z-15GW Z-15GQ Z-15GD
diode cross reference

Abstract: unimax OMRON microswitch V3L-139-D8 unimax switch series 9 relay cross reference V3L 121 D8 V3L-1122-D8 LM 1117 e61-60k
Text: Omron does not produce that type of switch Microswitch Cross Reference Microswitch Part Number , Omron 14 - 26 Unimax - Omron 27 - 33 Cross Reference Guide Key E= Exact Cross : Fit, form , Microswitch Cross Reference Microswitch Part Number OMRON Part Number Cross Type BZ-2RW822-A2 Z , calls out as follows: 5 Microswitch Cross Reference Microswitch Part Number OMRON Part , Microswitch Cross Reference Microswitch Part Number OMRON Part Number UM40B10B01 SS-5GL-F S


Original
PDF -15G3-1C25-K TMCJG6ST2740C diode cross reference unimax OMRON microswitch V3L-139-D8 unimax switch series 9 relay cross reference V3L 121 D8 V3L-1122-D8 LM 1117 e61-60k
2009 - E2EX5MF1

Abstract: e2e-x5f1 omron e2e-x2f1 Omron e2e inductive proximity sensor G9SX-LM224 IEC 60947-5-1 limit switch ex d megger E2E-X2MF1 ISO13849-1
Text: VDC) (Guard Lock Safety Door Switch (Mechanical Lock), 2-channel Safety Limit Switch Inputs/2 , T33 G9SX-LM224-F10 T41 T42 AND Control circuit S1: Safety Limit Switch S2: Guard Lock , closed Guard closed opened Limit switch S1 Timing Chart for Maintenance Mode (M1: OFF, M2: ON) Limit switch S1 Guard Lock Safety Door Switch S2 Guard Lock Safety Door Switch S2 Enabling , ), 2-channel Safety Limit Switch Inputs/2-channel Enabling Switch Inputs/Manual Reset) + G9SX-BC202


Original
PDF EN954-1) ISO13849-1) D-71154 7032-811-0/Fax: 847-843-7900/Fax: 6835-3011/Fax: 21-5037-2222/Fax: J172-E1-01 E2EX5MF1 e2e-x5f1 omron e2e-x2f1 Omron e2e inductive proximity sensor G9SX-LM224 IEC 60947-5-1 limit switch ex d megger E2E-X2MF1 ISO13849-1