7802901JA Intersil Corporation DATACOM, MANCHESTER ENCODER/DECODER, CDIP24, CERDIP-24
5962-9088801MRA Intersil Corporation DATACOM, MANCHESTER ENCODER/DECODER, CDIP20, CERDIP-20
HD1-15530-8 Intersil Corporation DATACOM, MANCHESTER ENCODER/DECODER, CDIP24, CERDIP-24
SF Impression Pixel

Search Stock (3)

  You can filter table by choosing multiple options from dropdownShowing 3 results of 3
Part Manufacturer Supplier Stock Best Price Price Each Buy Part
HDO4K-MANCHESTERBUS D Teledyne Lecroy Allied Electronics & Automation - $1465.00 $1465.00
WS10-MANCHESTERBUS D Teledyne Lecroy Allied Electronics & Automation - $1465.00 $1465.00
WSXS-MANCHESTERBUS D Teledyne Lecroy Allied Electronics & Automation - $1465.00 $1465.00

No Results Found

Show More

manchester Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
2001 - vhdl code manchester encoder

Abstract: vhdl code for manchester decoder vhdl code for clock and data recovery manchester encoder manchester verilog decoder manchester code verilog vhdl manchester vhdl code for nrz vhdl manchester encoder manchester encoder xilinx
Text: Application Note: CoolRunner® CPLDs R XAPP339 (v1.2) Jaunary 10, 2001 Manchester , and Verilog source code for a Manchester Encoder Decoder. The reasons to use Manchester code are , 6 for instructions. Introduction Manchester code is defined, and the advantages relative to Non-Return to Zero code are given. Target applications of Manchester code are discussed. Verilog and VHDL implementations of the Manchester Encoder-Decoder are available from the Xilinx website. The decoder and encoder


Original
PDF XAPP339 XC9572 XCR3064XL XAPP339 vhdl code manchester encoder vhdl code for manchester decoder vhdl code for clock and data recovery manchester encoder manchester verilog decoder manchester code verilog vhdl manchester vhdl code for nrz vhdl manchester encoder manchester encoder xilinx
2000 - vhdl code manchester encoder

Abstract: manchester verilog decoder manchester code verilog line code manchester vhdl manchester vhdl code for nrz Manchester code vhdl code for binary data serial transmitter vhdl code for manchester decoder vhdl code for clock and data recovery
Text: Application Note: CoolRunner® CPLDs R XAPP339 (v1.1) April 17, 2000 Manchester , and Verilog source code for a Manchester Encoder Decoder. The reasons to use Manchester code are , 6 for instructions. Introduction Manchester code is defined, and the advantages relative to Non-Return to Zero code are given. Target applications of Manchester code are discussed. Verilog and VHDL implementations of the Manchester Encoder-Decoder are available from the Xilinx website. The decoder and encoder


Original
PDF XAPP339 XC9572 XCR3064XL XAPP339 vhdl code manchester encoder manchester verilog decoder manchester code verilog line code manchester vhdl manchester vhdl code for nrz Manchester code vhdl code for binary data serial transmitter vhdl code for manchester decoder vhdl code for clock and data recovery
1998 - AN070

Abstract: philips application manchester manchester code verilog manchester verilog decoder manchester encoder an070
Text: INTEGRATED CIRCUITS AN070 Verilog implementation of a Manchester Encoder/Decoder in Philips , implementation of a Manchester Encoder/Decoder in Philips CPLDs AN070 In this application note, Manchester , applications of Manchester code are discussed. A verilog implementation of the Manchester Encoder­Decoder is , functions in CPLDs. In NRZ, only one level/data cell is required, while in Manchester , two levels are , frequency response for NRZ then ranges from DC to clock/2. The frequency response of Manchester code


Original
PDF AN070 AN070 philips application manchester manchester code verilog manchester verilog decoder manchester encoder an070
manchester verilog decoder

Abstract: DK20-9.5/110/124 manchester code verilog MD1010
Text: Philips Semiconductors Application note Verilog implementation of a Manchester Encoder/Decoder in Philips CPLDs AKJn_n ANU U INTRODUCTION In this application note, Manchester code is , Manchester code are discussed. A verilog implementation of the Manchester Encoder-Oecoder is given, along , . In NRZ, only one level/data cell is requited, while in Manchester , two levels are required. A DC , then ranges from DC to clock/2. The frequency response of Manchester code ranges from clock/2


OCR Scan
PDF mda0101010101 4400lrst manchester verilog decoder DK20-9.5/110/124 manchester code verilog MD1010
1997 - manchester code encoder diagram

Abstract: HD1-6409-9 differential manchester encoder hd-6409-9 HD3-6409-9 line code manchester HD9P6409-9 HD4-6409-9 5962-9088801MRA 5962-9088801M2A
Text: HD-6409 S E M I C O N D U C T O R CMOS Manchester Encoder-Decoder March 1997 Features Description · Converter or Repeater Mode The HD-6409 Manchester Encoder-Decoder (MED) is a high speed , , the MED converts Non return-to-Zero code (NRZ) into Manchester code and decodes Manchester code into Nonreturn-to-Zero code. For serial data communication, Manchester code does not have some of the deficiencies , converts the most commonly used code (NRZ) to Manchester code, the advantages of using Manchester code


Original
PDF HD-6409 HD-6409 manchester code encoder diagram HD1-6409-9 differential manchester encoder hd-6409-9 HD3-6409-9 line code manchester HD9P6409-9 HD4-6409-9 5962-9088801MRA 5962-9088801M2A
1998 - manchester verilog decoder

Abstract: manchester encoder an070 manchester code verilog Verilog implementation of a Manchester Encoder/Decoder philips application manchester philips application manchester verilog AN070 manchester encoder verilog code for uart communication manchester code
Text: INTEGRATED CIRCUITS AN070 Verilog implementation of a Manchester Encoder/Decoder in Philips , implementation of a Manchester Encoder/Decoder in Philips CPLDs AN070 In this application note, Manchester , applications of Manchester code are discussed. A verilog implementation of the Manchester Encoder­Decoder is , functions in CPLDs. In NRZ, only one level/data cell is required, while in Manchester , two levels are , frequency response for NRZ then ranges from DC to clock/2. The frequency response of Manchester code


Original
PDF AN070 manchester verilog decoder manchester encoder an070 manchester code verilog Verilog implementation of a Manchester Encoder/Decoder philips application manchester philips application manchester verilog AN070 manchester encoder verilog code for uart communication manchester code
1999 - manchester encoder

Abstract: HD-6409 manchester code encoder diagram HD9P6409-9 HD4-6409-9 HD3-6409-9 HD1-6409-9 5962-9088801MRA 5962-9088801M2A manchester
Text: HD-6409 CMOS Manchester Encoder-Decoder March 1997 Features Description · Converter or Repeater Mode The HD-6409 Manchester Encoder-Decoder (MED) is a high speed, low power device , return-to-Zero code (NRZ) into Manchester code and decodes Manchester code into Nonreturn-to-Zero code. For serial data communication, Manchester code does not have some of the deficiencies inherent in , commonly used code (NRZ) to Manchester code, the advantages of using Manchester code are easily realized


Original
PDF HD-6409 HD-6409 manchester encoder manchester code encoder diagram HD9P6409-9 HD4-6409-9 HD3-6409-9 HD1-6409-9 5962-9088801MRA 5962-9088801M2A manchester
2010 - vhdl code for clock and data recovery

Abstract: vhdl code for PLL manchester code differential manchester encoder differential manchester system design using pll vhdl code "differential manchester" vhdl code manchester encoder vhdl code for manchester decoder manchester verilog decoder
Text: signal integrity for the entire system. Manchester encoding is a method used to combine data and a clock to form a single self-synchronizing data stream, while Manchester decoding is to retrieve the , perform the clock data recovery. The Differential Manchester code is an alternative to the standard Manchester code. Both have their advantages and are being used in different application areas. One of the , Manchester code, Differential Manchester code will operate in the same manner if the signal is inverted


Original
PDF RD1051 1-800-LATTICE vhdl code for clock and data recovery vhdl code for PLL manchester code differential manchester encoder differential manchester system design using pll vhdl code "differential manchester" vhdl code manchester encoder vhdl code for manchester decoder manchester verilog decoder
1997 - Manchester code

Abstract: FN2951 HD-6409-9 HD9P6409-9Z96 HD9P6409-9Z HD9P6409-9 HD-6409 HD3-6409-9 manchester coding manchester
Text: HD-6409 ® Datasheet July 29, 2005 CMOS Manchester Encoder-Decoder Features The HD-6409 Manchester Encoder-Decoder (MED) is a high speed, low power device manufactured using self-aligned silicon , Manchester code and decodes Manchester code into Nonreturn-to-Zero code. For serial data communication, Manchester code does not have some of the deficiencies inherent in Nonreturn-to-Zero code. For instance , Manchester code, the advantages of using Manchester code are easily realized in a serial data link


Original
PDF HD-6409 HD-6409 FN2951 Manchester code HD-6409-9 HD9P6409-9Z96 HD9P6409-9Z HD9P6409-9 HD3-6409-9 manchester coding manchester
2002 - cyclic redundancy check verilog source

Abstract: vhdl code manchester encoder vhdl code for manchester decoder verilog code for uart communication vhdl code for clock and data recovery vhdl manchester manchester code manchester verilog decoder manchester vhdl code for uart communication
Text: Application Note: CoolRunnerTM CPLDs R XAPP339 (v1.3) October 1, 2002 Manchester , and Verilog source code for a Manchester Encoder Decoder. The reasons to use Manchester code are , Download, page 6 for instructions. Introduction Manchester code is defined, and the advantages relative to Non-Return to Zero code are given. Target applications of Manchester code are discussed. Verilog and VHDL implementations of the Manchester Encoder-Decoder are available from the Xilinx website


Original
PDF XAPP339 XC9572, XCR3064XL, XC2C64 XAPP339 cyclic redundancy check verilog source vhdl code manchester encoder vhdl code for manchester decoder verilog code for uart communication vhdl code for clock and data recovery vhdl manchester manchester code manchester verilog decoder manchester vhdl code for uart communication
differential manchester encoder

Abstract: decoding of return to zero format manchester code encoder diagram state line code manchester HD-6409 NON RETURN TO ZERO manchester code encoder diagram harris 6409 HD-6431 utilizes Manchester Bi-Phase
Text:  SEMICONDUCTOR PRODUCTS DIVISION Of HARRIS CORPORATION HD-6409 CMOS Manchester Encoder-Decoder (MED) Features • CONVERTER OR REPEATER MODE • INDEPENDENT MANCHESTER ENCODER AND DECODER , TEMPERATURE RANGE • 20 PIN PACKAGE Description The HD-6409 Manchester Encoder-Decoder (MED) is a high , MED converts Non Return to Zero code (NRZ) into Manchester code and decodes Manchester code into Non Return to Zero code. For serial data communication, Manchester code does not have some of the


OCR Scan
PDF HD-6409 HD-6409 -32pF TYPJ-30Ã HD-6431, HD-6433, HD-6495 differential manchester encoder decoding of return to zero format manchester code encoder diagram state line code manchester NON RETURN TO ZERO manchester code encoder diagram harris 6409 HD-6431 utilizes Manchester Bi-Phase
2002 - CODER MANCHESTER DIFFERENTIAL

Abstract: HD9P6409-9 HD-6409 HD4-6409-9 HD3-6409-9 HD1-6409-9 5962-9088801MRA 5962-9088801M2A manchester encoder line code manchester
Text: HD-6409 TM CMOS Manchester Encoder-Decoder March 1997 Features Description · Converter or Repeater Mode The HD-6409 Manchester Encoder-Decoder (MED) is a high speed, low power , converts Non return-to-Zero code (NRZ) into Manchester code and decodes Manchester code into Nonreturn-to-Zero code. For serial data communication, Manchester code does not have some of the deficiencies , converts the most commonly used code (NRZ) to Manchester code, the advantages of using Manchester code


Original
PDF HD-6409 HD-6409 CODER MANCHESTER DIFFERENTIAL HD9P6409-9 HD4-6409-9 HD3-6409-9 HD1-6409-9 5962-9088801MRA 5962-9088801M2A manchester encoder line code manchester
td 1555

Abstract: BUS-1555
Text: ~ 7^75^ MANCHESTER II DECODER FOR TEST EQUIPMENT FEATURES · 16 MHz , error detection, the BUS-1555 Manchester II Decoder Module avails itself to a wide range o f , decoder. The BUS-1555 w ill sample Manchester II inpu t data at 16 MHz, which im proves b it recognition , Manchester II phasing errors. Control logic outputs include Line Active, Frame, Sync Detector, Sync Type and , include both ground and on board avionics system. · ERROR FLAGS FOR SYNC MANCHESTER II ERROR HIGH AND


OCR Scan
PDF BUS-1555 MIL-STD-1553 BUS-1555 MIL-STD1553 BUS-63105 BUS-8559 td 1555
2013 - Not Available

Abstract: No abstract text available
Text: trademarks or requested trademarks of their respective holders. manchester-nrz_ds_19feb13 Teledyne , Manchester and NRZ Configurable Protocol Decode Quickly decode serial buses that use Manchester , help verify bus performance and debug • U  ser definable protocol decoding of Manchester and , color-coded decode is overlaid directly on physical layer waveform The Configurable Manchester and , Manchester or NRZ based The physical layer specs like bit rate, industry standard buses like PSI5, S


Original
PDF 19feb13
harris 6409

Abstract: Manchester code CTS Electronic Components converter 1011134 CMOS nrz Level Converter
Text: MANCHESTER '0' MANCHESTER '1' I MANCHESTER'1' | MANCHESTER'0' | MANCHESTER '0' | FIGURE 11. 5-36 HARRIS , T S/V b I HARRIS SEMICOND SECTOR HS rri DE| 4305271 GG11131 1 T-ys-si HD'6409 § CO CMOS Manchester ô Encoder-Decoder (MED) x Features • Converter or Repeater Mode • Independent Manchester , +125<>C Description The HD-6409 Manchester Encoder-Decoder (MED) Is a high speed, low power device , Nonreturn-to-Zero code (NRZ) into Manchester code and décodés Manchester code into Nonreturn-to-Zero code. For


OCR Scan
PDF GG11131 HD-6409-9. HD-6409-2/-8. -550C HD-6409 -30il -16Mft harris 6409 Manchester code CTS Electronic Components converter 1011134 CMOS nrz Level Converter
2005 - generation circuit of manchester

Abstract: hardware implementation of bpsk manchester encoder example manchester rf communication DATA BOOK manchester decoder manchester BPSK transmitters definition of microcontroller AN3435
Text: bit in Manchester-encoded data can become confusing, because each binary data bit encoded results in , Manchester-encoded data stream does require two levels for each transition, because by definition the information is , as many logic-level states to encode data in Manchester. However, the use of the phrase " Manchester , data bit or a Manchester-encoded bit. The term chip is often used to describe the level periods on , 5 shows an example of a Manchester-encoded serial-input data stream and the resulting output data


Original
PDF com/an3435 MAX1470: MAX1471: MAX1472: MAX1479: MAX7033: AN3435, APP3435, Appnote3435, generation circuit of manchester hardware implementation of bpsk manchester encoder example manchester rf communication DATA BOOK manchester decoder manchester BPSK transmitters definition of microcontroller AN3435
2007 - manchester coding

Abstract: atmel application note manchester coding utilizes Manchester Bi-Phase manchester Biphase U2270 CS11
Text: this article, Manchester. Also it should be mentioned that we are simply looking at coding digital , Manchester Coding Basics When beginning to work with communication systems, it is important to , our communication system. Manchester Coding Basics Application Note 1. Modulation Modulation , or interference will not be detected without some form of data integrity checks. 2 Manchester Coding Basics 9164A­AUTO­09/09 Manchester Coding Basics 2.2 BiPhase BiPhase adds a level of


Original
PDF
BUS-63105

Abstract: UT 63105 manchester RDO-RD15 63105 BUS-1555 7S57 C3C30 Biphase decoder manchester coding
Text: 04897 D T"7S~S7 ILC DATA DEVICE CORPORATION _ BUS-1555 MIL-STD-1553 MANCHESTER II DECODER FOR TEST , capability and precise message error detection, the BUS-1555 Manchester II Decoder Module avails itself to a , compatible with this decoder. The BUS-1555 will sample Manchester II input data at 16 MHz, which improves , , odd parity and Manchester II phasing errors. Control logic outputs include Line Active, Frame, Sync , include both ground and on board avionics system. ERROR FLAGS FOR SYNC MANCHESTER II ERROR HIGH AND LOW


OCR Scan
PDF 4B78769 BUS-1555 MIL-STD-1553 16MHz BUS-1555 BUS-63105 BUS-8559 UT 63105 manchester RDO-RD15 63105 7S57 C3C30 Biphase decoder manchester coding
2005 - M68EVB908Q

Abstract: M68EVB908Q 1.2 manchester encoder AN3015 HCS12x microcontroller Manchester CODING DECODING MC33493 HCS12X FSK DEcoder manchester code
Text: ( Manchester_Decoding_ook.c / XGATE_Manchester_decoding_ook.cxgate), or FSK modulation ( Manchester_decoding_fsk.c , of the core that will be performing the Manchester decoding is in Manchester_Decoder_General.h. , peripherals and internal RAM. The process of decoding Manchester-coded signals requires intensive interrupt , application note discusses a proposed implementation to decode Manchester-coded signals using the XGATE. The , process. Only one timer channel is needed. When a Manchester-encoded signal is sampled in a channel with


Original
PDF AN3015 HCS12X M68EVB908Q M68EVB908Q 1.2 manchester encoder AN3015 HCS12x microcontroller Manchester CODING DECODING MC33493 FSK DEcoder manchester code
Not Available

Abstract: No abstract text available
Text: HD-6409 Semiconductor March CMOS Manchester Encoder-Decoder 1997 Features Description • Converter or Repeater Mode The HD-6409 Manchester Encoder-Decoder (MED) is a high speed , mode, the MED converts Non return-to-Zero code (NRZ) into Manchester code and decodes Manchester code into Nonreturn-to-Zero code. For serial data communication, Manchester code does not have some of the , converts the most comm only used code (NRZ) to Manchester code, the advantages of using Manchester code


OCR Scan
PDF HD-6409 HD-6409
line code manchester

Abstract: manchester code encoder diagram state manchester code encoder diagram Technitrol Manchester code Manchester block diagram origin MB Manchester c source code technitrol 11 MEDM2150
Text: « 35-55 mA usage current. ö Independent Manchester II encoder/decoder operation, o On-chip divide-by-two , Technitrol Manchester II encoder/decoder module (MEDM™) serves as a complete Manchester interface between a , is available at any dedicated data rate, from 1 Mb/s to 50 Mb/$. It offers independent Manchester II , : T'75-51 Applications that employ Manchester code generally require very reliable data transmission and interfacing, and high noise immunity. Manchester II code has a 50% duty cycle and contains a data


OCR Scan
PDF 16-pin line code manchester manchester code encoder diagram state manchester code encoder diagram Technitrol Manchester code Manchester block diagram origin MB Manchester c source code technitrol 11 MEDM2150
Biphase decoder

Abstract: BUS-1555 manchester Manchester block diagram BUS-63105 BUS-8559
Text: -1555 MIL-STD-1553 MANCHESTER II DECODER FOR TEST EQUIPMENT FEATURES • 16 MHz CLOCK RATE DESCRIPTION AND , -1555 Manchester II Decoder Module avails Itself to a wide range of applications. The decoder is encapsulated in a , Manchester II input data at 16 MHz, which improves bit recognition and overall system capability. Error flags are provided for low and high bit count, odd parity and Manchester II phasing errors. Control logic , MANCHESTER II ERROR HIGH AND LOW BIT COUNT CONFORMS TO MIL-STD-1553 A&B 16 BIT PARALLEL AND NRZ SERIAL


OCR Scan
PDF 00073b3 BUS-1555 MIL-STD-1553 BUS-63105 BUS-8559 VII-16 Biphase decoder manchester Manchester block diagram
1997 - Not Available

Abstract: No abstract text available
Text: HD-6409 ® Data Sheet October 15, 2008 CMOS Manchester Encoder-Decoder Features The HD-6409 Manchester Encoder-Decoder (MED) is a high speed, low power device manufactured using , ) into Manchester code and decodes Manchester code into Nonreturn-to-Zero code. For serial data communication, Manchester code does not have some of the deficiencies inherent in Nonreturn-to-Zero code. For , Manchester code, the advantages of using Manchester code are easily realized in a serial data link


Original
PDF HD-6409 HD-6409 FN2951
hd1-6409-9

Abstract: No abstract text available
Text: MANCHESTER‘1†™ MANCHESTER‘0†™ \ MANCHESTER‘0†™ MANCHESTER ‘1’ ECLK BZO , Tflfl MANCHESTER‘O†™ I I \ , HD-6409 ff) HARRIS S E M I C O N D U C T O R CMOS Manchester Encoder-Decoder August 1996 Features Description • Converter or Repeater Mode The HD-6409 Manchester Encoder-Decoder (MED , the converter mode, the MED converts Non return-to-Zero code (NRZ) into Manchester code and decodes


OCR Scan
PDF HD-6409 HD-6409 00bfllfl3 hd1-6409-9
generation circuit of manchester

Abstract: BPSK transmitters AN3435 manchester APP3435 MAX1472 MAX1471 MAX7033 MAX1470 hardware implementation of bpsk
Text: definition of a bit in Manchester-encoded data can become confusing, because each binary data bit encoded , Manchester-encoded data stream does require two levels for each transition, because by definition the information is , as many logic-level states to encode data in Manchester. However, the use of the phrase " Manchester , data bit or a Manchester-encoded bit. The term chip is often used to describe the level periods on , 5 shows an example of a Manchester-encoded serial-input data stream and the resulting output data


Original
PDF MAX1470: MAX1471: MAX1472: MAX1479: MAX7033: AN3435, APP3435, Appnote3435, generation circuit of manchester BPSK transmitters AN3435 manchester APP3435 MAX1472 MAX1471 MAX7033 MAX1470 hardware implementation of bpsk
Supplyframe Tracking Pixel