The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
LTC2942CDCB#PBF Linear Technology LTC2942 - Battery Gas Gauge with Temperature, Voltage Measurement; Package: DFN; Pins: 6; Temperature Range: 0°C to 70°C
LTC2941CDCB#PBF Linear Technology LTC2941 - Battery Gas Gauge with I2C Interface; Package: DFN; Pins: 6; Temperature Range: 0°C to 70°C
LTC2942IDCB#TRMPBF Linear Technology LTC2942 - Battery Gas Gauge with Temperature, Voltage Measurement; Package: DFN; Pins: 6; Temperature Range: -40°C to 85°C
LTC2942CDCB#TRMPBF Linear Technology LTC2942 - Battery Gas Gauge with Temperature, Voltage Measurement; Package: DFN; Pins: 6; Temperature Range: 0°C to 70°C
LTC2941IDCB#TRPBF Linear Technology LTC2941 - Battery Gas Gauge with I2C Interface; Package: DFN; Pins: 6; Temperature Range: -40°C to 85°C
LTC4150CMS#PBF Linear Technology LTC4150 - Coulomb Counter/Battery Gas Gauge; Package: MSOP; Pins: 10; Temperature Range: 0°C to 70°C

magnet wire gauge equivalent Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
1999 - simple circuit magnetic reed switch

Abstract: cr2 lithium 40509 rain gauge
Text: $5.50 Environmental Sensing A 1- Wire www.sensorsmag.com Rain Gauge ©Reprinted from SENSORS , SENSING A 1- Wire Rain Gauge The conventional tipping bucket method of rainfall measurement can be , temperature using Dallas's 1- Wire technology [1]. Adding a rain gauge to the station requires only that it be , bucket rain gauge mechanism to operate on the 1- Wire net is a simple matter of wiring its reed switch , gathered in the lid portion of the gauge trickles down into the upper bucket through a small-diameter hole


Original
PDF
1999 - rain gauge

Abstract: weather station rain SENSOR magnetic reed switch simple circuit magnetic reed switch DS2423 magnet wire gauge equivalent rainfall board weather station DS2407
Text: Environmental Sensing A 1- Wire www.sensorsmag.com Rain Gauge ©Reprinted from SENSORS, December 1999 , SENSING A 1- Wire Rain Gauge The conventional tipping bucket method of rainfall measurement can be , a rain gauge to the station requires only that it be connected to the 1- Wire bus by plugging it , the same bus. Measuring Rainfall the 1- Wire Way Adapting the standard tipping bucket rain gauge , adding an LCD readout. Summary The rain gauge is a useful and desirable addition to the 1- Wire


Original
PDF
Not Available

Abstract: No abstract text available
Text: m o l e x " M agKrim p” LEAD WIRE to MAGNET WIRE Vs— / Magnet Wire Gauge 12 14,15 - Lead Wire Gauge 14 16 19195-0003 19195-0003 - 19195-0009 19195-0003 , recommended for aluminum magnet wire finer than 21 gauge 19195-0008 - 19195-0038 - - , 19195-0038 MAGNET WIRE to MAGNET WIRE Magnet Wire Gauge 2 5 19195-0005 Wires Per , 19195-0038 19195-0038 19195-0038 - Not recommended for aluminum magnet wire finer than 21 gauge


OCR Scan
PDF
2014 - "15/32-32 UNS-2A"

Abstract: 103SR19A-1 15/32-32 UNS-2A
Text: various environmental conditions. LEAD WIRE GAUGE AND LENGTH OPTIONS Lead wires of different gauges , ±0,76 mm [3 x 0.24 in ±0.03 in] 3X 24 gauge conductor wire leads (individual wires) 3 x , mm [3 x 0.24 in ±0.03 in] 3X 24 gauge conductor wire leads (individual wires) 3 x 1000 mm  , . 103SR13A-8 3 x 6,01 mm ±0,76 mm [3 x 0.24 in ±0.03 in] 3X 24 gauge conductor wire leads (individual , gauge conductor cable 3 x 6,01 mm ±0,76 mm [3 x 0.24 in ±0.03 in] 3X 24 gauge conductor wire


Original
PDF 103SR 005971-1-EN "15/32-32 UNS-2A" 103SR19A-1 15/32-32 UNS-2A
2002 - TBM15

Abstract: Thomas Betts erg 3000 Thomas Betts 13600 Thomas Betts 13600 maintenance manual ERG3000 204210 ERG-3008 13610A hand switch ERG-3001
Text: . * Not recommended for aluminum magnet wire finer than 21 gauge . (a) Four wires max. (b) Six wires max , . . . . . . . O8 Magnet Wire Ordering Information. . . . . . . . . . . . . . . . . . . . . . . . . , The tough, high temperature insulation on magnet wire used by electrical motor and transformer manufacturers creates problems in splicing and terminating. The durability of magnet wire insulation has made , aluminum magnet wire to copper is faced with the problem of the different coefficients of thermal


Original
PDF 15500TB. 204210MT 204210S 204210SH 204210-1H 204210-3H 204MT14 204MT38 204T14 204T38 TBM15 Thomas Betts erg 3000 Thomas Betts 13600 Thomas Betts 13600 maintenance manual ERG3000 204210 ERG-3008 13610A hand switch ERG-3001
103SR13A-11

Abstract: 1N10 hall sensor 2A magnet switch
Text: MAGNET IS FROM THE NORTH TO THE SOUTH POLE OF THE MAGNET 22 GAUGE IRRADIATED PVC INSULATED CONDUCTORS , MAGNET 22 GAUGE IRRADIATED PVC INSULATED CONDUCTORS WITH THERMOPLASTIC POLYURETHANE JACKET DATE CODE , 39.370s.300 22 GAUGE CONDUCTOR CABLE (3) /f\ 15/32-32 UNS-2A HEX NUT (2) 1.000^.040 SENSING FACE /6 , -' 'Vs (+) RED WIRE HALL TRIGGER CIRCUIT SENSOR AND AMPLIFIER OUTPUT (0) NORMALLY HIGH BROWN WIRE S ■GROUND (-) BLACK WIRE BLOCK DIAGRAM SHOWING CURRENT SINKING OUTPUTS NOTES n ZIX


OCR Scan
PDF C064722 C074092E C081515A 103SR13A-11 103SR13A-11 1N10 hall sensor 2A magnet switch
103SR13A-12

Abstract: circuit sensor
Text: MAGNET IS FROM THE NORTH TO THE SOUTH POLE OF THE MAGNET 22 GAUGE PVC INSULATED CONDUCTORS WITH MOLDED , SOUTH POLE OF THE MAGNET /A 22 GAUGE PVC INSULATED CONDUCTORS WITH MOLDED PVC JACKET 7K DATE CODE , 78.960s.300 22 GAUGE CONDUCTOR CABLE (3) /f\ 15/32-32 UNS-2A HEX NUT (2) 1.000^.040 SENSING FACE /6 , . HALL SENSOR TRIGGER CIRCUIT AND AMPLIFIER 5-' HC ' 5—I-' Vs (+) RED WIRE OUTPUT (0) NORMALLY HIGH WHITE WIRE GROUND (-) BLACK WIRE BLOCK DIAGRAM SHOWING CURRENT SINKING OUTPUTS NOTES n Â


OCR Scan
PDF D074092B 81515A 103SR13A-12 103SR13A-12 circuit sensor
1994 - EF25 transformer

Abstract: etd39 core type smps full bridge transformer design Nyleze AN-16 topswitch EF20 TRANSFORMER TDK EF25 epoxylite 203 EE19 TDK Ferrite Core PC40 EPOXYLITE 814 EFD20 TDK Ferrite Core PC40
Text: Wire . PI-1810-032896 Figure 4. Use of Insulating Sleeving. than the equivalent size of magnet , Materials A wire table provides dimensional and electrical characteristics for magnet wire , and is used , table is provided in Appendix A with data on AWG wire sizes from 18 gauge through 44 gauge . SWG and , . Wire tables can be obtained from some of the magnet wire manufacturers listed in Appendix A. A , application. Magnet Wire Transformer Construction Materials The following paragraphs describe the basic


Original
PDF AN-18 AN-16. EF25 transformer etd39 core type smps full bridge transformer design Nyleze AN-16 topswitch EF20 TRANSFORMER TDK EF25 epoxylite 203 EE19 TDK Ferrite Core PC40 EPOXYLITE 814 EFD20 TDK Ferrite Core PC40
T0650

Abstract: T0100 T0300 T0400 T0500 T0600
Text: : from 0.750" to 3.00". · Lead length "X" : 12 inches (typical). · Lead wire gauge sizes from #22 to , Magnet wires or small ribbon cables. · Maximum temp. ratings from 60°C up to 260°C. Options · , 0.080" to 0.250". · Lead length "X" : 72 inches (typical). · Lead-wire gauge sizes from #32 to #40 AWG , glass probe thermistor types<0.040" OD. · Insulation sleeve body, open end. · Magnet wires or small , gauge sizes from #32 to #40 AWG. TYPE T0300: Features · Thermistor sub-assemblies for use as


Original
PDF T0100: T0200: T0650 T0100 T0300 T0400 T0500 T0600
T0100

Abstract: T0300 T0400 T0500 T0600 T0650
Text: : 12 inches (typical). · Lead wire gauge sizes from #22 to #30 AWG. Crown Industrial Estate , end. · Magnet wires or small ribbon cables. · Maximum temp. ratings from 60°C up to 260 , "B" : from 0.080" to 0.250". · Lead length "X" : 72 inches (typical). · Lead-wire gauge sizes from , Magnet wires or small ribbon cables. · Maximum temp. ratings from 60°C up to 260°C. Options · , (typical). · Lead-wire gauge sizes from #32 to #40 AWG. TYPE T0300: Features · Thermistor


Original
PDF T0100: T0200: T0100 T0300 T0400 T0500 T0600 T0650
2003 - EE19 core

Abstract: HIGH FREQUENCY Transformer ee19 EE19 type core Transformer ee19 EE19 transformer schematic of tny268 EE19 type bobbin TOP244P IC tny268 core ee19 transformer schematic
Text: : Horizontal 8 pins [3] Magnet Wire : # 31 AWG [4] Magnet Wire : # 35 AWG [5] Triple Insulated , 66 turns in 2 layers with # 31 AWG magnet wire ­ first layer 33T from right to left starting from , from left to right with # 35 AWG magnet wire starting temporarily from pin 6 and finish at pin 4, wind , winding-2) Wind 33 turns in one layer with # 31 AWG magnet wire from left to right starting , Thickness (= 2 mm * film thickness) mm Bare conductor diameter Primary Wire Gauge (Rounded to next AWG


Original
PDF TNY268P 3V/10mA DER-11 TNY268P EE19 core HIGH FREQUENCY Transformer ee19 EE19 type core Transformer ee19 EE19 transformer schematic of tny268 EE19 type bobbin TOP244P IC tny268 core ee19 transformer schematic
Not Available

Abstract: No abstract text available
Text: OF THE MAGNET 22 GAUGE PVC INSULATED CONDUCTORS WITH MOLDED PVC JACKET DATE CODE LOCATED IN THIS AREA , 78.74 Od= .300 /2 3X 22 GAUGE CONDUCTOR CABLE /2\ 2X PLASTIC NUT /8 OOOzh. 040 .125 SENSING , , THE CIRCUIT CANNOT BE DAMAGED BY MAGNET 1C OVERDR1VE ELECTRICAL CHARACTERISTICS M 1 N TYP MAX , AMPLIFIER *—1-« V s (+) RED WIRE OUTPUT (0) NORMALLY HIGH WHITE OR BROWN WIRE GROUND (-) BLACK WIRE , OF THE MAGNET WILL OPERATE THE SENSOR WHEN MAGNET IS POSITIONED AS SHOWN IN FIGURE 2. THIS ASSUMES


OCR Scan
PDF
2006 - MBRS160

Abstract: NCP1014 MBR140 equivalent 2W flyback transformer 1,5kV schematic dvd NCP1014 equivalent winding temp gauge 1N5229B Zener Diode EQUIVALENT flyback transformer 5 watts 8 pin C 47uf/400v
Text: / Material / Gauge / Insulation Data Aux/Vcc winding (1 - 2) 9 turns of 32HN (0.25 mm dia) magnet wire , (3 - 4) 88 turns of #32HN (0.25 mm dia) magnet wire over 2 layers with 44 turns per layer. Allow , Vishay H11A817A optocoupler or equivalent . 3. L1 is Coilcraft BU16-4530R5BL or similar CM EMI inductor , secondary (6 - 5) 5 turns of #26HN (0.46 mm) wire spiral wound with 3 mm end margins. Self-leads to pins. 5V secondary (5 - 7) 4 turns of 0.46 mm wire spiral wound between the turns of the previous


Original
PDF DN06003/D NCP1014 NCP1014 MBRS160 MBR140 equivalent 2W flyback transformer 1,5kV schematic dvd NCP1014 equivalent winding temp gauge 1N5229B Zener Diode EQUIVALENT flyback transformer 5 watts 8 pin C 47uf/400v
103SR18-1

Abstract: No abstract text available
Text: 24.0 VDC LATCHING DEVICE 3X 6.00Ozh .3000 .250±. 030 i_ 000d= . 040 3X 24 GAUGE CONDUCTOR WIRE , WITHIN 0.025 SWITCH SYMBOL FIG. NOTES 7A ZA FLUX ENTERING THE SOUTH POLE OF THE MAGNET WILL OPERATE THE SENSOR WHEN THE MAGNET IS POSITIONED AS SHOWN IN FIGURE 2. THIS ASSUMES THE CONVENTION THAT THE DIRECTION OF THE EXTERNAL FLUX OF A MAGNET IS FROM THE NORTH TO THE SOUTH POLE OF THE MAGNET . BIPOLAR , RELEASE RESPECTIVELY (FIGURES 2 AND 3) LEADWIRES (INDIVIDUAL WIRES) ARE 24 GAUGE STRANDED WITH XLPE


OCR Scan
PDF 23AUG88 00Ozh 103SR18-1 103SR18-1
103SR17A-2

Abstract: No abstract text available
Text: 39.370=h .300 4.5 TO 24 VDC BI POLAR DEVICE 3X 22 GAUGE CONDUCTOR CABLE 5/32-32 UNS-2A 2X HEX NUT , WIRE OUTPUT (0) NORMALLY HIGH WHITE WIRE GROUND (-) BLACK WIRE BLOCK DIAGRAM SHOWING CURRENT SINKING OUTPUTS NOTES AA FLUX ENTERING THE SOUTH POLE OF THE MAGNET WILL OPERATE THE SENSOR WHEN MAGNET IS , MAGNET IS FROM THE NORTH TO THE SOUTH POLE OF THE MAGNET . BIPOLAR DEVICES REQUIRE THE THE PRESENTATION OF , ) /2\ 22 GAUGE WITH XLPE INSULATED CONDUCTORS WITH MOLDED PVC JACKET 7K DATE CODE LOCATED IN THIS AREA


OCR Scan
PDF 103SR17A-2 103SR17A-2
137 hall SENSOR

Abstract: 103SR13A-8 MICRO switch hall Sensor
Text: FLUX OF A MAGNET IS FROM THE NORTH TO THE SOUTH POLE OF THE MAGNET 22 GAUGE PVC INSULATED CONDUCTORS , 39.370± . 300 3X 22 GAUGE CONDUCTOR CABLE Z2\ 4.5 TO 24 VDC UNIPOLAR DEVICE 5/32-32 UNS-2A STAINLESS , ) RED WIRE OUTPUT (0) NORMALLY HIGH WHITE WIRE GROUND (-) BLACK WIRE BLOCK DIAGRAM SHOWING CURRENT SINKING OUTPUTS NOTES /1\ FLUX ENTERING THE SOUTH POLE OF THE MAGNET WILL OPERATE THE SENSOR WHEN MAGNET


OCR Scan
PDF 103SR13A-8 137 hall SENSOR 103SR13A-8 MICRO switch hall Sensor
Not Available

Abstract: No abstract text available
Text: OF THE MAGNET 2 2 GAUGE PVC INSULATED CONDUCTORS WITH MOLDED PVC JACKET /3 \ /A DATE CODE LOCATED IN , OPERATING OPERATE RELEASE DIFF 3 9 .3 7 *.3 0 /2 3X 2 2 GAUGE CONDUCTOR CABLE / 2 MIN , TO 90 % 10% o X 0 5 1 Û_ O' (/) NUMBER o / s o < CL (+) RED WIRE DRAWING , AMPLIFIER | OUTPUT (0) NORMALLY HIGH WHITE OR BROWN WIRE ^GROUND ( - ) BLACK WIRE BLOCK DIAGRAM , OF THE MAGNET WILL OPERATE THE SENSOR WHEN MAGNET IS POSITIONED AS SHOWN IN FIGURE 2. THIS ASSUMES


OCR Scan
PDF SR4P3-B10
MICRO switch hall Sensor

Abstract: 103SR13A-2
Text: FLUX OF A MAGNET IS a FROM THE NORTH TO THE SOUTH POLE OF THE MAGNET /Z\ 22 GAUGE PVC INSULATED , u 39.370± . 300 3X 22 GAUGE CONDUCTOR CABLE ZÏX 4.5 TO 24 VDC UNIPOLAR DEVICE 5/32-32 UNS , ) RED WIRE OUTPUT (0) NORMALLY HIGH WHITE WIRE GROUND (-) BLACK WIRE BLOCK DIAGRAM SHOWING CURRENT SINKING OUTPUTS NOTES ZK FLUX ENTERING THE SOUTH POLE OF THE MAGNET WILL OPERATE THE SENSOR WHEN MAGNET


OCR Scan
PDF 40TED 103SR13A-2 MICRO switch hall Sensor 103SR13A-2
1N10

Abstract: 103SR13A-9 2 wire LT HALL SENSOR
Text: rr Vs ( + ) RED WIRE OUTPUT (0) NORMALLY HIGH BROWN WIRE GROUND (-) BLACK WIRE BLOCK DIAGRAM SHOWING CURRENT SINKING OUTPUTS NOTES /1\ FLUX ENTERING THE SOUTH POLE OF THE MAGNET WILL OPERATE THE SENSOR WHEN MAGNET IS POSITIONED AS SHOWN IN FIGURE 2. THIS ASSUMES THE CONVENTION THAT THE DIRECTION OF THE EXTERNAL FLUX OF A MAGNET IS a FROM THE NORTH TO THE SOUTH POLE OF THE MAGNET /2\ 22 GAUGE , I 18.000±.300 4.5 TO 24 VDC UNIPOLAR DEVICE 3X 22 GAUGE CONDUCTOR CABLE ZZ\ 5/32-32 UNS-2A 2X


OCR Scan
PDF 103SR13A-9 1N10 103SR13A-9 2 wire LT HALL SENSOR
T1600

Abstract: Thermistor types T1700 T1000 T1100 T1200 T1300 T1400 T1500
Text: types <0.050" OD. · Small diameter metal tubing, open end. · Magnet wires or small ribbon cables. · , length "X" : 12 inches (typical). · Lead-wire gauge sizes from #32 to #40 AWG. TYPE T1100: Features , glass probe thermistor types <0.040" OD. · Small diameter metal tubing, open end. · Magnet wires or , inches (typical).* Lead-wire gauge sizes from #32 to #40 AWG. TYPE T1200: Features · Rugged, fast , thermistor types <0.100" OD. · Small diameter metal tubing, closed end. · Magnet wires or small ribbon


Original
PDF T1000: T1100: T1600 Thermistor types T1700 T1000 T1100 T1200 T1300 T1400 T1500
Not Available

Abstract: No abstract text available
Text: 2Mounting Gauge #20-18 AWG Magnet Wire Hole Diameter 0.052" (1.32mm) 1Wire Applicator , 4000 WT t Please Consult Factory For Product Performance Data Based On A Specific Wire Gauge , Wire , lPlease Consult Factory For Product Performance Data Based On A Specific Wire Gauge , Wire Style, Wire , Product Performance Data Based On A Specific Wire Gauge , Wire Style, Wire Insulation Diameter and PCB , Consult Factory For Product Performance Data Based On A Specific Wire Gauge , Wire Style, Wire Insulation


OCR Scan
PDF outpe14-6
103SR13A-1

Abstract: hall sensor 2A magnet switch
Text: 4.5 TO 24 VDC UNIPOLAR DEVICE 6.00 0=b .300(3 ) OPERATING OOOdz. 040 24 GAUGE CONDUCTOR WIRE , . 040 OPERATING 24 GAUGE CONDUCTOR WIRE LEADS (3) /2\ GAUSS OPERATE MAX 495 RELEASE MIN 200 DIFF , CURRENT SINKING OUTPUTS oo I_I + Vs NOTES FLUX ENTERING THE SOUTH POLE OF THE MAGNET WILL OPERATE THE SENSOR WHEN MAGNET IS POSITIONED AS SHOWN IN FIGURE 2. THIS ASSUMES THE CONVENTION THAT THE DIRECTION OF THE EXTERNAL FLUX OF A MAGNET IS FROM THE NORTH TO THE SOUTH POLE OF THE MAGNET LEADWIRES


OCR Scan
PDF 103SR13A-1 103SR13A-1 hall sensor 2A magnet switch
T1600

Abstract: T1700 T1000 T1100 T1200 T1300 T1400 T1500 Thermistor types
Text: <0.050" OD. · Small diameter metal tubing, open end. · Magnet wires or small ribbon cables. · Maximum , length "X" : 12 inches (typical). · Lead-wire gauge sizes from #32 to #40 AWG. TYPE T1100: Features , glass probe thermistor types <0.040" OD. · Small diameter metal tubing, open end. · Magnet wires or , inches (typical).* Lead-wire gauge sizes from #32 to #40 AWG. TYPE T1200: Features · Rugged, fast , thermistor types <0.100" OD. · Small diameter metal tubing, closed end. · Magnet wires or small ribbon


Original
PDF T1000: T1100: T1600 T1700 T1000 T1100 T1200 T1300 T1400 T1500 Thermistor types
103SR14A-2

Abstract: hall switch
Text: FLUX OF A MAGNET IS a FROM THE NORTH TO THE SOUTH POLE OF THE MAGNET /Z\ 22 GAUGE PVC INSULATED , 39.370± . 300 4.5 TO 24 VDC POLAR DEVICE 3X 22 GAUGE CONDUCTOR CABLE /2\ 5/32-32 UNS-2A 2X HEX NUT , ) RED WIRE OUTPUT (0) NORMALLY HIGH WHITE WIRE GROUND (-) BLACK WIRE BLOCK DIAGRAM SHOWING CURRENT SINKING OUTPUTS NOTES ZK FLUX ENTERING THE SOUTH POLE OF THE MAGNET WILL OPERATE THE SENSOR WHEN MAGNET


OCR Scan
PDF 103SR14A-2 103SR14A-2 hall switch
2004 - EE16 10 pin bobbin transformers

Abstract: lnk354 EE16 bobbin tokin 473 PC40EE16-Z LNK354P vogt transformer EE16 6 pin bobbin transformers ee1625 EE16 9 pin bobbin transformers
Text: or equivalent Gapped for AL of 70 nH/T2 Bobbin: EE16 Horizontal 10 pin Magnet Wire : #37 AWG Magnet Wire : #34 AWG Magnet Wire : #28 AWG Triple Insulated Wire : #25 AWG. Tape: 3M 1298 Polyester Film, 2.0 , Primary Wire Gauge (Rounded to next smaller standard AWG value) Bare conductor effective area in circular , Output Capacitor RMS Ripple Current Secondary Bare Conductor minimum circular mils Secondary Wire Gauge , Output Winding Bare Conductor minimum circular mils Wire Gauge (Rounded up to next larger standard AWG


Original
PDF EP-73 LNK354P) EPR-73 25-Oct-04 EN550022 CISPR-22 EE16 10 pin bobbin transformers lnk354 EE16 bobbin tokin 473 PC40EE16-Z LNK354P vogt transformer EE16 6 pin bobbin transformers ee1625 EE16 9 pin bobbin transformers
Supplyframe Tracking Pixel