The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
LTC1531CSW#TRPBF Linear Technology IC COMP ISOLATED SLF-PWRD 28SOIC
LT1034-2.5#TR Linear Technology IC SPECIALTY ANALOG CIRCUIT, Analog IC:Other
LT1009M2 Linear Technology IC SPECIALTY ANALOG CIRCUIT, Analog IC:Other
LT1034-1.2#TR Linear Technology IC SPECIALTY ANALOG CIRCUIT, Analog IC:Other
LTC202 Linear Technology IC SPECIALTY ANALOG CIRCUIT, Analog IC:Other
LT1009 Linear Technology IC SPECIALTY ANALOG CIRCUIT, Analog IC:Other

isolated 4 to 20ma analog transmitter circuit Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
2014 - Not Available

Abstract: No abstract text available
Text: Isolated Transmitter TxxxxB Series Single channel Analog signal FEATURES Four-port , repaired or changed for free. Applied circuit See Application Notes for Isolated Transmitter for , Output Signal T1530B 4 ~ 20mA 0~10V 24V None T1533B 4 ~ 20mA 0~10V 24V 24V T1630B 4 ~ 20mA 0~5V 24V None 24V T1633B 4 ~ 20mA 0~5V 24V T1650B 4 ~ 20mA 0 , None 4 ~ 20mA 4 ~ 20mA 24V None 4 ~ 20mA 4 ~ 20mA 24V 24V None T1130B T1133B


Original
PDF 2500VDC/60S) 35PPM/â IEC61326-1) 17-B/1
PT100 temperature sensor JUMO

Abstract: PT100 JUMO 0-10V to 0-20mA converter 0-10V 4.....20MA Current to voltage Converter 4-20mA to 0-10v PT-1000 sensor resistance to Current Converter 0-20mA Pt 100 sensor connection namur standard Pt 1000 sensor connection
Text: , resistance transmitter , potentiometer, voltage (up to ±10V), current (up to ± 20mA ) Outputs 0/ 4 - , to ±10V), current (up to ± 20mA ) thermocouple, resistance thermometer, resistance transmitter , 0.1 steps 30 per conductor for 4 -wire circuit 15 per conductor for 2- and 3-wire circuit up to , current 4 to 20mA 0 to 20mA -20 to + 20mA -60 to -60 to freely programmable within the limits , 0 -500 0 -1 -5 0 -10 -60 to 2-, 3- or 4 -wire circuit Shortest span Input for DC


Original
PDF 1-800-554-JUMO TTL/RS232 PT100 temperature sensor JUMO PT100 JUMO 0-10V to 0-20mA converter 0-10V 4.....20MA Current to voltage Converter 4-20mA to 0-10v PT-1000 sensor resistance to Current Converter 0-20mA Pt 100 sensor connection namur standard Pt 1000 sensor connection
2000 - DIN 43710

Abstract: 7070-25 JUMO dTRANS T02 Ex jumo TTL RS232 converter dtrans JUMO dTRANS T02 LCD USB TTL jumo 707021 W5Re-W26Re PT100 temperature sensor JUMO
Text: , resistance transmitter , potentiometer, voltage (up to ±10V), current (up to ± 20mA ) Outputs 0/ 4 - , -wire circuit ) 15 per conductor (for 2-wire circuit ) Sensor current 4 to 20mA 0 to 20mA -20 to + 20mA , stranded or solid wire up to 2.5mm² conductor cross-section. Depending on the type, the 0/ 4 - 20mA or 0/2 , to ±10V), current (up to ± 20mA ) thermocouple, resistance thermometer, resistance transmitter , Range Accuracy up to 400 up to 2000 ±500m ±1 Connection circuit 2-, 3- or 4


Original
PDF 1-800-554-JUMO TTL/RS232 DIN 43710 7070-25 JUMO dTRANS T02 Ex jumo TTL RS232 converter dtrans JUMO dTRANS T02 LCD USB TTL jumo 707021 W5Re-W26Re PT100 temperature sensor JUMO
2004 - visipak

Abstract: action instruments visipak V430-0000 4-20ma DIGITAL CURRENT SOURCE V430-2000 0-20mA 0.5V V430 10VA V430-3000 4-20ma controller
Text: second cycle. The unit has an isolated 24V excitation source to power a two-wire transmitter or the , span from 4 to 20mA is less than 501 counts, an error message will appear. Output Loop Resistance , latching alarm. An isolated 4-20mA transmitter output that follows the rate input is also available. The totalized count alarms can be configured to trip at an absolute or offset count (e.g., setpoint #1 4 , & 4-20mA Transmitter Output The V430 accepts 4-20mA, 0-20mA, 0-5V, 1-5V, 0-10V analog inputs and


Original
PDF 4-20mA, V430-0000 V430-1000 V430-2000 4-20mA V430-3000 115VAC 741-F 721-0695-00-F visipak action instruments visipak V430-0000 4-20ma DIGITAL CURRENT SOURCE V430-2000 0-20mA 0.5V V430 10VA V430-3000 4-20ma controller
isolated 4 to 20ma analog transmitter circuit

Abstract: EN50081-1 EN50082-1 SCM5B42-02 SCM5B42 SCM5B42-01 SCMXR1
Text: transmitter to be directly connected to the SCM5B42 without requiring an external power supply. The regulated supply will provide a nominal +20VDC at a loop current of 4mA to 20mA . q ISOLATED +20VDC CURRENT LOOP , Nominal 20V at 4mA to 20mA Isolated Excitation Protection Continuous Transient Input Protection , is required between an isolated 2-wire transmitter and the input stage of the control room computer , voltage output is logic switch controlled, which allows these modules to share a common analog bus


Original
PDF SCM5B42 SCM5B42 20VDC 1500Vrms EN50081-1, EN50082-1, SCM5B42-01 SCM5B42-02 isolated 4 to 20ma analog transmitter circuit EN50081-1 EN50082-1 SCM5B42-02 SCM5B42-01 SCMXR1
SYM20C15

Abstract: Voltage to Current Converter 4-20mA XTR116 dC digital voltmeter advantage & disadvantage A519HRT xtr115 rtd maxim 4-20ma receiver HT2012
Text: transmitter to 4 wire receiver- there would have to be some form o f level shifting or isolation in both the , transmitter is being driven by a Digital to Analog Converter (DAC), the calibration can done by adjusting the , - simplicity for the user. A power supply, a transmitter , a receiver, and two to four wires is all it takes. A , electrical background. A massive installed base hasn't hurt, I'm sure. There used to be a 20mA digital , transmitter and receiver connected together by conductors. The transmitter sends an analog current where 0% of


OCR Scan
PDF 4-20mA SYM20C15 Voltage to Current Converter 4-20mA XTR116 dC digital voltmeter advantage & disadvantage A519HRT xtr115 rtd maxim 4-20ma receiver HT2012
2014 - 7d560

Abstract: No abstract text available
Text: years warranty. Applied circuit Please refer to Isolated Transmitter Application Notes Design , to a 4 ~ 20mA standard signal isolation accurately conversion, which be used in a variety of , signal is converted to standard 4 ~ 20mA signal within the two-wire current loop. HART send the , for the Transmitting of the sensor signal to the 4 ~ 20mA standard current signal and the HART , HART FEATURES Convert voltage to current and offer isolated power output Self-powered, no


Original
PDF 2KVAC/1mA/60s) 50ppm/â 7d560
2014 - Not Available

Abstract: No abstract text available
Text: Isolated Transmitter TAxxxPW series Programmable analog isolators with isolated power output , Isolated Transmitter TAxxxPW series Application Precautions 1. 2. 3. 4 . Please read the , Isolated Transmitter TAxxxPW series Dimensions Note: 1. Packing information please refer to , power output which are mainly applied in industrial automation systems can isolated convert analog input signal of the industrial field instruments to the matched analog output signal for the DCS/PLC


Original
PDF 50PPM/Â
2007 - RH -005c RELAY DC 5V

Abstract: C250 RH -005c RELAY modbus RS485 relay spdt 5v 2a design PID Controller Digital temperature controller with PT100 rtd
Text: 50.0 · 4 to 20mA analog output · Logic 18V time proportioning ( to drive solid state relays , , PID single loop controller Analog , configurable in the range of 4 to 20mA Autotune facility , _7 .Specification Analog Input Number One as standard One optional 4 to 20mA remote set point input Input , Process Input · · · · Primary Outputs Thermocouple RTD 4 to 20mA Volts, millivolts 1 x , sensors and built-in transmitter supply. Optional isolated retransmission for input to recorders


Original
PDF SS/C250 125mm NEMA4X/IP66 RS485/Modbus C100/0700) SS/C250 RH -005c RELAY DC 5V C250 RH -005c RELAY modbus RS485 relay spdt 5v 2a design PID Controller Digital temperature controller with PT100 rtd
AN-4483

Abstract: isolated 4 to 20ma analog transmitter circuit AN4483 pwm modulator Galvanic isolation transformer abstract precision 4-20ma current source APP4483 MAX4236 BSP149
Text: % duty cycle and 20mA at 100%. For PWM input frequencies in the range 500Hz to 50kHz, the circuit , Aug 05, 2010 APPLICATION NOTE 4483 PWM-controlled 4­20mA transmitter is galvanically isolated , transmitter and external to it. External to the transmitter are spurious paths in the outside loop wiring and its power supply. Internal to the transmitter , shunt paths and ground loops are usually created at the point where you insert a control signal into the transmitter circuitry. To eliminate errors introduced


Original
PDF 4-20mA MAX4636 MAX6138 25ppm, com/an4483 AN4483, APP4483, Appnote4483, AN-4483 isolated 4 to 20ma analog transmitter circuit AN4483 pwm modulator Galvanic isolation transformer abstract precision 4-20ma current source APP4483 MAX4236 BSP149
2007 - modicon 984 ANALOG OUTPUT

Abstract: ABB Pt100 3 wire modicon SSC160 modbus protocol 4 to 20mA relay spdt 230v 5A C160 rs485 modbus connection modbus RS485
Text: Analog , configurable in the range of 4 to 20mA Max. load 15V (750 at 20mA ) Accuracy 0.25% of span , . Pipe-mounted C160 Indicator Universal Process Input · · · · · Thermocouple RTD 4 to 20mA Volts , flashing LEDs to the right of the main display. Isolated Retransmission The C160 has, as standard, a 4 , A standard feature in the C160 is flow totalization. This totals any 4 to 20mA flow signal. With , ) Milliamps 0 to 20mA 0.2% or 2A Milliamps 4 to 20mA 0.2% or 2A Volts 0 to 5V 0.2% or


Original
PDF SS/C160 IP66/NEMA4X RS485/Modbus SS/C160 modicon 984 ANALOG OUTPUT ABB Pt100 3 wire modicon SSC160 modbus protocol 4 to 20mA relay spdt 230v 5A C160 rs485 modbus connection modbus RS485
2000 - Current to voltage Converter 4-20mA using LM324

Abstract: Voltage to Current Converter 4-20mA XTR110 LM324 isolated 4 to 20ma analog transmitter circuit LM324 as 0 to 10 V to 4 to 20mA converter Siliconix Handbook Voltage to Current Converter 4-20mA LM324 XTR110 XTR110KP
Text: 20mA Out RL VL FIGURE 9. Isolated 4mA to 20mA Channel. +24V 15 16 12 4 0V to +10V 3 5 9 2 , ® XTR110 PRECISION VOLTAGE-TO-CURRENT CONVERTER/ TRANSMITTER FEATURES q 4mA TO 20mA TRANSMITTER q SELECTABLE INPUT/OUTPUT RANGES: 0V to +5V, 0V to +10V Inputs 0mA to 20mA , 5mA to 25mA Outputs , transmission. It accepts inputs of 0 to 5V or 0 to 10V and can be connected for outputs of 4 to 20mA , 0 to 20mA , INFORMATION Figure 1 shows the basic connections required for 0 to 10V input and 4 to 20mA output. Other


Original
PDF XTR110 XTR110 input/2000) XTR110AG XTR110BG XTR110KP XTR110KU XTR110KU/1K images/xtr110 Current to voltage Converter 4-20mA using LM324 Voltage to Current Converter 4-20mA XTR110 LM324 isolated 4 to 20ma analog transmitter circuit LM324 as 0 to 10 V to 4 to 20mA converter Siliconix Handbook Voltage to Current Converter 4-20mA LM324
2004 - V438

Abstract: visipak led moving message display circuits c action instruments visipak V438-0000 digital Water Meter V438-3000 Eurot Eurotherm 4-20ma DIGITAL CURRENT SOURCE
Text: Input Spans Input Minimum Span 0 to 5V 0.16V 0 to 10V 0.32V 4 to 20mA 1.6mA 11 , -1V) 4 to 20mA 1.6/(No. of pts -1mA) Model V438 Wiring Diagrams DC Input Digital Indicator , results. Specifications BASIC METER Inputs Field selectable: 4 to 20mA , 1 to 5V, 0 to 5V and 0 , counts less than the rate corresponding to 4mA (for example, 4mA = 0, 20mA = 501). If the span from 4 , Status Optional 2 Relay Output & 4-20mA Transmitter Output Isolated 24VDC Excitation for 2


Original
PDF 4-20mA, 4-20mA 24VDC 004mA V438-0000 V438-1000 V438-2000 V438-3000 V438 visipak led moving message display circuits c action instruments visipak V438-0000 digital Water Meter V438-3000 Eurot Eurotherm 4-20ma DIGITAL CURRENT SOURCE
2B22J

Abstract: "Pressure transmitter" type 501 isolated 4 to 20ma analog transmitter circuit 2B22L 2B22 circuit diagram 0-10V industrial interface "Isolation Amplifier" 10-50ma 2B22K 2B23 AC1579
Text: €” Isolated 4 to 20mA Interface Pressure Transmitter : In Figure 9, model 2B22 is used in a pressure , 0 to +10V. The isolated output current range is 4 to 20mA , and the 2B22 can be operated with 0 to , microcomputer and standard 4 to 20mA analog loops. DESIGN FEATURES AND USER BENEFITS High Reliability: Model , block diagram for model 2B22 is shown in Figure 2 below. The 2B22 produces an isolated 4 to 20mA output , 4 to 20mA output from accidental shorts to a.c line voltages. The circuit shown in Figure 6 can be


OCR Scan
PDF 2B20B) 2B22L 2B22J "Pressure transmitter" type 501 isolated 4 to 20ma analog transmitter circuit 2B22 circuit diagram 0-10V industrial interface "Isolation Amplifier" 10-50ma 2B22K 2B23 AC1579
2007 - Digital temperature controller with PT100 rtd

Abstract: commander ABB Wire RTD Transmitter relay spdt 230v 2a C10012 C100 op1 m power thermocouple IEC751 PID controller 751
Text: outputs. M OP2 · 4 to 20mA analog · Logic 18V time proportioning ( to drive solid state , /retransmission Size Analog , configurable in the range of 4 to 20mA Max. load 15V (750 at 20mA , SS/C100_12 Universal Process Input Primary Outputs · Thermocouple · RTD · 4 to 20mA · , standard inputs: One as standard One optional ( 4 to 20mA remote set point input) Input sampling rate , None ­ One additional relay ­ Two additional relays + one digital input + remote set point 4 to 20mA


Original
PDF SS/C100 RS485/Modbus SS/C100 Digital temperature controller with PT100 rtd commander ABB Wire RTD Transmitter relay spdt 230v 2a C10012 C100 op1 m power thermocouple IEC751 PID controller 751
2007 - RH -005c RELAY DC 5V

Abstract: RH -005c RELAY relay spdt 5v 2a relay spdt 230v 2a fm transmitter flow chart Data Logger modbus OF RELAY -5V, 230V INPUT PT100 RTD IEC 751 C150 modicon
Text: · · · · Outputs Thermocouple RTD 4 to 20mA Volts, millivolts · Analog retransmission , totals any 4 to 20mA flow signal. With the built-in transmitter power supply and root extraction this , installed from Retransmission Analog , configurable in the range of 4 to 20mA Type 1 One relay Two , main display. Retransmission The C150 has, as standard, a 4 to 20mA output for retransmission of , Milliamps 4 to 20mA 0.2% or 2A Volts 0 to 5V 0.1% or 200V Volts 1 to 5V 0.1% or


Original
PDF SS/C150 RS485/Modbus C100/0700) SS/C150 RH -005c RELAY DC 5V RH -005c RELAY relay spdt 5v 2a relay spdt 230v 2a fm transmitter flow chart Data Logger modbus OF RELAY -5V, 230V INPUT PT100 RTD IEC 751 C150 modicon
logoprint

Abstract: PT-100 thermocouple sensitivity chart calibration of jumo logoprint ER8 jumo jumo TTL RS232 converter cable 954012 smps circuit diagram AC to DC smps circuit diagram download pages isolated 4 to 20ma analog transmitter circuit PT-100 temperature transducer
Text: °C max. 30 per core for 4 -wire circuit max. 20 per core for 2- and 3-wire circuit for Pt 100 up to 260 , resistance transmitter : 3-wire circuit potentiometer: 2-, 3- or 4 -wire circuit Shortest span 6 , 1V in 1mV steps) ±20µA ±20µA ±40µA 4 - 20mA 0 - 20mA -20 to + 20mA Shortest span , -wire 4 -wire -200 to +250°C -200 to +850°C -200 to +250°C -200 to +850°C ±0.6°C ±1.0°C ±0.5°C ±0.8°C 500µA 250µA 500µA 250µA Pt 100 JIS 2/3-wire 2/3-wire 4 -wire 4 -wire -200 to


Original
PDF 1-800-554-JUMO 24-character TTL/RS232 RS422 RS485 logoprint PT-100 thermocouple sensitivity chart calibration of jumo logoprint ER8 jumo jumo TTL RS232 converter cable 954012 smps circuit diagram AC to DC smps circuit diagram download pages isolated 4 to 20ma analog transmitter circuit PT-100 temperature transducer
2009 - manual gefran 200

Abstract: manual gefran 40T gefran 200 manual gefran 40t gefran 40t manual GEFRAN display 200 gefran 40T 48 E216851 gefran 200
Text: 24V±10% (10Vmin / 20mA ). One output of 4 to 20mA (max. 500Ω) is available for retranmitting the , 0 to 60mV / 12 to 60mV 0 to 10V / 2 to 10V 0 to 5V / 1 to 5V 0 to 1V / 0,2 to 1V 0 to 20mA / 4 , reset, hold, flash zero, display of the peak value (max., min. or peak to peak). Isolated 2/ 4 wires , instruments have a lexan membrane faceplate (guaranteed to IP65) which has 3 keys, a 4 digit display and 3 , Pt100, Pt100J 2 / 3 wire • PTC and NTC themistors • Linear inputs 0 to 60/12 to 60mV, 0 to 20/ 4


Original
PDF 48x48 Pt100, Pt100J 10Mohm E216851 2004/108/CE 2006/95/CE manual gefran 200 manual gefran 40T gefran 200 manual gefran 40t gefran 40t manual GEFRAN display 200 gefran 40T 48 E216851 gefran 200
2B22J

Abstract: isolated 4 to 20ma analog transmitter circuit 2B22K 2B22 2B22L
Text: 1LSB (19.9961mA). Figure 8. D/A Converter — Isolated 4 to 20mA Interface Pressure Transmitter : In , voltage ranges from 0 to +1V to 0 to +10V. The isolated output current range is 4 to 20mA , and the 2B22 , between the D/A converter output of a microcomputer and standard 4 to 20mA analog loops. DESIGN FEATURES , Figure 2 below. The 2B22 produces an isolated 4 to 20mA output current which is proportional to the , (e.g. 1 to 5mA, 4 to 20mA , 10 to 50mA, 1 to 5V) and convert them to isolated 4 to 20mA output. A


OCR Scan
PDF 2B22L 2B22J isolated 4 to 20ma analog transmitter circuit 2B22K 2B22 2B22L
2B35

Abstract: isolated 4 to 20ma analog transmitter circuit 0-10V signal isolator circuit diagram 0-10V industrial interface Isolated 4-20ma 2B22 bridge transducer 4-20ma transmitter 2B22L 2B22K 2B22J
Text: 0 to +10V. The isolated output current range is 4 to 20mA , and the 2B22 can be operated with 0 to , standard 4 to 20mA analog loops. DESIGN FEATURES AND USER BENEFITS High Reliability: Model 2B22 is a , (e.g. 1 to 5mA, 4 to 20mA , 10 to 50mA, 1 to 5 V) and convert them to isolated 4 to 20mA output. A , of 20mA less 1LSB (19.9961mA). Figure 8. D/A Converter - isolated 4 to 20mA Interface Pressure , . The high level voltage output of the 2B30 is converted to the isolated 4 to 20mA current for


OCR Scan
PDF 2B22L 2B35 isolated 4 to 20ma analog transmitter circuit 0-10V signal isolator circuit diagram 0-10V industrial interface Isolated 4-20ma 2B22 bridge transducer 4-20ma transmitter 2B22L 2B22K 2B22J
2B22J

Abstract: isolated 4 to 20ma analog transmitter circuit
Text: interface between the D/A converter output of a microcomputer and standard 4 to 20mA analog loops. DESIGN , shown in Figure 2 below. The 2B22 produces an isolated 4 to 20mA output current which is proportional to , 50mA, 1 to 5V) and convert them to isolated 4 to 20mA output. A typical hook-up of model 2B22 is , is converted to the isolated 4 to 20mA current for transmission to a remote recorder or indicator , programmable to accept voltage ranges from 0 to +1V to 0 to +10V. The isolated output cur rent range is 4 to


OCR Scan
PDF 2B22L 2B22J isolated 4 to 20ma analog transmitter circuit
Vishay nobel AST 3

Abstract: BASEEFA 02 ATEX 0053 Zener PH Vishay nobel nobel modbus-rtu Baseefa02ATEX0053 vishay nobel gate 3s
Text: AST 3IS Vishay Nobel Transmitter Transducers FEATURES · Unique design to allow transducers in hazardous areas without the need of zener barriers · Analog output ± 10VDC, ± 0 - 20 or 4 - 20mA · Serial communications: RS-485, MODBUS RTU protocol · Relay outputs · Compact DIN rail , its heart a unique Nobel patented analog to digital converter. The unit is equipped with analog as , % ± 3.3mV/V <0.005% of used range 8.8VDC to 6VDC with 1 to 6 of 350 ohm transducers, isolated 500V


Original
PDF 10VDC, RS-485, 95/98/2000/NT4/ME/XP. 08-Apr-05 Vishay nobel AST 3 BASEEFA 02 ATEX 0053 Zener PH Vishay nobel nobel modbus-rtu Baseefa02ATEX0053 vishay nobel gate 3s
2004 - STRAIN GAUGE

Abstract: 0-200mV tare "strain gauge" V430 10VA led digital panel amp volt meter isolated 4 to 20ma analog transmitter circuit visipak ohms meter panel
Text: counts less than the rate corresponding to 4mA (for example, 4mA = 0, 20mA = 501). If the span from 4 to 20mA is less than 501 counts, an error message will appear. Loop Power Isolated , up to 20mA at , up to +199990 Count Spans 4 Visual Alarm Points with Front Panel LED Status The V434 is a 1/8 , latching alarm. An isolated 4-20mA transmitter output is also available as an option. The V434 accepts , , 10V or 24V excitation source to power a bridge or strain gauge, or the optional two-wire transmitter


Original
PDF 0-30mV, 0-200mV, 100mV 24VDC 004mA V434-0000 V434-1000 V434-2000 4-20mA V434-3000 STRAIN GAUGE 0-200mV tare "strain gauge" V430 10VA led digital panel amp volt meter isolated 4 to 20ma analog transmitter circuit visipak ohms meter panel
2005 - modicon plc PID EXAMPLE

Abstract: LT 543 7 segment display 24V 5A SPST RELAY water tank LOGIC CONTROL PLC 7 SEGMENT DISPLAY LT 543 C501 10VA pt100 multiplexer modicon isolated 4 to 20ma analog transmitter circuit
Text: from the rest of the circuitry Analog range 4 Operators 0 and 20mA (programmable), accuracy , 0 to 20mA analog or 17V @ 20mA digital Power consumption <10VA Power interruption protection , operation Comprehensive input/output capabilities ­ up to three analog inputs, two analog outputs, four , Analog /Logic 2 x Relay Outputs PID Control Alarms Retransmission Transmitter Power Supply (45mA , offers comprehensive sequencing, to complement its advanced analog control features, and six logic


Original
PDF SS/C501 C100/0700) SS/C501 modicon plc PID EXAMPLE LT 543 7 segment display 24V 5A SPST RELAY water tank LOGIC CONTROL PLC 7 SEGMENT DISPLAY LT 543 C501 10VA pt100 multiplexer modicon isolated 4 to 20ma analog transmitter circuit
2005 - commander cr100

Abstract: commander ABB KPC-100 KPC100-1047 CR100 digital thermometer using 8051 ABB Pt100 3 wire 5 digit led display IEC751 EN61010-1
Text: IP65/NEMA3 protection Outputs Retransmission Analog configuration in the range of 4 to 20mA Max , individual channels or common to both Isolated analog retransmission ­ easy connection to management , · · · · · Single Pen Thermocouple RTD 4 to 20mA Volts, Millivolts Tx Power Supply , Thermocouple RTD 4 to 20mA Volts, Millivolts Tx Power Supply 5-digit LED display · Two Relays · , standard: · Two alarm relays · Isolated analog retransmission · Two digital inputs ·


Original
PDF 100mm SS/CR100 CR100 IP65/NEMA3 SS/CR100 commander cr100 commander ABB KPC-100 KPC100-1047 CR100 digital thermometer using 8051 ABB Pt100 3 wire 5 digit led display IEC751 EN61010-1
Supplyframe Tracking Pixel