The Datasheet Archive

Top Results (4)

Part Manufacturer Description Datasheet Download Buy Part
UPS12458 GE Critical Power CUST INTERFACE CARD-RELAY CARD
UPS18802 GE Critical Power OPTION CARD-USB, RS232 & RELAY
CLTEQ-RELAY-A2440 TE Connectivity Ltd CLTEQ-RELAY-A2440
FW1120D00 (2-1617530-0) TE Connectivity (2-1617530-0) FW1120D00=FW RELAY

interposing relay Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
2010 - interposing relay

Abstract: Allen-Bradley auxiliary contact 595-A 592-EUTB 500F-BOD930 592-EEHE 509-FOD 599-KA04 509-BOD Bulletin 709 Motor Starter Coil 599-k04
Text: poles) 19.8 65.7 61 4860 254 6 ( Interposing relay ) 52.44 3.96 74.40 7 ( Interposing relay ) 8 9.84 74.40 9§ - - 9.84 144 4 - Economized DC Coil 9 ( Interposing relay ) 3 - Economized DC Coil 8 ( Interposing relay ) 85.110% - Economized , starters are shipped with an interposing relay as standard. Size 7 starters are shipped with a 250 VA control circuit transformer and an interposing relay with a 120V coil. Voltage is then rectified to DC for


Original
PDF 800T/H 500-SG008A-EN-P interposing relay Allen-Bradley auxiliary contact 595-A 592-EUTB 500F-BOD930 592-EEHE 509-FOD 599-KA04 509-BOD Bulletin 709 Motor Starter Coil 599-k04
BROWN BOVERI relay

Abstract: interposing relay RXMM 1 BROWN BOVERI relay type S B03-9301E BROWN BOVERI BROWN BOVERI type s relay B03-1212 B03-9382E relay
Text: supervisory control interposing relay applications where minimum mounting space is available for either small , BOVERI DllSl 3UXiM3ry relay , Data subject to change without notice 4 or 6 contacts Abstract • Self-reset • DC voltage operated • 2 relay units per module k • 2 or 3 medium- (trip-) duty contacts per relay unit no, nc, or transfer • 1.6 W maximum power consumption per relay unit Application The RXMM 1 dml auxiliary relays are particularly useful where more than one general purpose auxiliary relay


OCR Scan
PDF B03-1212 ce3-1212E 002-AD B03-9301E B03-1003E B03-9382E S-72171 BROWN BOVERI relay interposing relay RXMM 1 BROWN BOVERI relay type S BROWN BOVERI BROWN BOVERI type s relay relay
Not Available

Abstract: No abstract text available
Text: . For inhibit, the customer will have to provide an isolated solid state switch or interposing relay to


Original
PDF KBRG-212D/-213D KBRG-240D/225D/255 KBRG-212D/213D KBRG-212D KBRG-213D A34260) A49083) SCREWRG-213D
ca2-Dn22

Abstract: ca2dn22 EN1050 XPS-ot XPS-AT XPS-AS GNKL CA2-DN XPS-AL XPS-ASf
Text: Components for safety applications Preventa safety modules Intermediate relay concepts Operation of the control circuit without interposing relays 1 The control signal from the protection , interposing relays Feedback loop KM6 KM5 Emergency stop Preventa safety module KM5 KM6 , contacts M Independent safety circuits Preventa safety modules provide a reliable interposing relay function by overcoming a number of risks associated with : - control circuit fault (inputs), -


Original
PDF
709 series K Allen-Bradley Starter

Abstract: Allen-Bradley auxiliary contact 595-A Allen-Bradley starter 709 A2JD Allen-Bradley auxiliary contact 595-AB westinghouse contactor 195-FA11 interposing relay 196-fta smp1 OVERLOAD RELAY
Text: -AAA-A2B. Only available on sizes 00 to 5. When using 24V coils on sizes 4 or 5, an interposing relay may be , transformer). Only available on sizes 00 to 5. When using 24V coils on sizes 4 or 5, an interposing relay , coils on size 4 or 5, an interposing relay may be required. See coil VA values on page 24 , SMP­1 Overload Relays Control Circuit Schematic for Separate Control with Interposing Relay , Interposing Relay L1 L2 Primary Fuses (When Used) H2 "J" H3 H1 H4 FUSE X 1 (When


Original
PDF
2013 - Not Available

Abstract: No abstract text available
Text: Description The XTA-MRNO-6 is an interposing relay module with six digital inputs and six mechanical relay , Ethernet I/O: BusWorks XT Series ® XTA-MRNO Mechanical Relay Output Modules BOTTOM VIEW , CHANNEL (1 OF 6) R2A 21 22 23 24 LED RELAY DIGITAL INPUT TVS IN+ R4A 21 22 23 24 , TB2 OF TX2 38V RELAY OUTPUT RLY RLY DRIVER ISOLATED CONTACTS 100K BUFF 0.1uF 10K (PULL-DOWN) 114.5 (4.51) RTN RTN DIGITAL INPUT RELAY OUTPUT 4-32V DC 0-4V DC RTN


Original
PDF
RK 891 031-aa

Abstract: interposing relay RK 211 074 RK 211 064 RXMS1 ABB make RED 670 rk 223 069 ec abb rk 216 RXME 1 rk 211 072
Text: flown, i.e. as a series trip current flag (target). SCADA Interposing Relay type RXSF 1 Interposing , interposing relay type RXSF 1 · Immune to AC induced voltages across coil up to 150 V AC · Maximum , Scada interposing relay RXSF 1 Ordering Number: 1MRK 001 799-AP A 11 12 13 15 17 14 16 , , down to 1,5 ms · Up to 15 contacts in one relay · Low power consumption Application The , RXMA 1, RXMA 2 and RXMM 1 are used as position repeat relays, as interposing relays in control


Original
PDF 015-BEN 031-AA, 284-AAA 001-BEN 019-BEN 017-BEN 002-BEN 007-BEN 003-BEN RK 891 031-aa interposing relay RK 211 074 RK 211 064 RXMS1 ABB make RED 670 rk 223 069 ec abb rk 216 RXME 1 rk 211 072
rz-24 relay

Abstract: 8530660000 interposing relay
Text: 8556020000 8556030000 8556090000 8556100000 1793970000 PUMP MOTOR INTERPOSING RELAY n i _


OCR Scan
PDF
2002 - dr5te4u

Abstract: DR5TE4U contactor coil rectifier LC1-F115 LC1-D40 LX1D6M5 LC1 F150 LC1-D115 LC1 F115 LC1 Schneider lx1d6f7
Text: Stop button, or · Use an interposing relay . LX1D6 For additional information on D-Line


Original
PDF 8502CT9901R2/01 dr5te4u DR5TE4U contactor coil rectifier LC1-F115 LC1-D40 LX1D6M5 LC1 F150 LC1-D115 LC1 F115 LC1 Schneider lx1d6f7
2013 - VS6902

Abstract: No abstract text available
Text: the interposing relay . The majority of SIS applications are de-energize-to-trip. If a , Auxiliary Relay Diode module to achieve additional functionality.  Enables diagnostics of field wiring all the way to a high-current discrete end device  Monitors that the relay changed state , DeltaV offers the Auxiliary Relay Energize to Actuate (ETA Direct) module. For applications where the current to the final device needs to be switched on when the system trips, there is the Auxiliary Relay


Original
PDF
2008 - c316fna3

Abstract: contactor wiring diagram with timer
Text: interposing relay which can switch a specified 50/60 Hz AC source to the contactor or starter coil , blocks and overload relay . 16 16 16 16 16 PG03300001E For more information visit , into the overload relay base Table 16-19. Starters with Series B Overload Relays 16 16 16 16 16 16 Series 00 – 0 1–2 5 6 7–8 C B B C B Overload Relay Size 32A or 75A , to a carton. Catalog Numbers are for 3 heater packs. Sizes 5 – 8 use the 32A overload relay with


Original
PDF PG03300001E c316fna3 contactor wiring diagram with timer
2013 - Not Available

Abstract: No abstract text available
Text: 5.H – NOT RECOMMENDED – Using in Intermediate ( Interposing ) Relay for a Status Contact 7000 , user must install an interposing relay within the breaker that will interface between the drive , description in this section regarding wire sizing and routing. 'CR1' represents an interposing relay to be , Automation medium voltage AC drive to the circuit breaker. The Drive Input Control (DIC) relay contacts , breaker. Protection Circuit trips 86 Lockout Relay 86 DIC (In Drive) Trip Circuit


Original
PDF 7000-AT003B-EN-P 7000-AT003A-EN-P
2006 - wye-delta controller with timer

Abstract: Allen-Bradley contactor B110 OVERLOAD RELAY smp1 OVERLOAD RELAY 100-b110 interposing relay star delta wiring diagram motor start y smp1 400 vac 193-NX15 1203-SG2 schematic
Text: contactor exceeds the triac or relay rating an interposing relay must be used. ATTENTION: When power is , wiring ATTENTIONS. T1 T2 T3 T1 3-20 40 50 SMP-3 60 M Interposing Relay 10 , ÌÌ ÌÌ ÌÌ A1 A1 Ì Interposing Relay CRF SMP-3 20 30 40 50 60 CRR FOR , L1 30 CRF CRF Interposing Relay 10 To 120V AC Supply ÌÌ ÌÌ CRR 20 FOR , (with Triac Control) L1 ÌÌ ÌÌ Low ÌÌ ÌÌ A2 CRH A1 CRL A2 Interposing Relay SMP


Original
PDF NX1311 wye-delta controller with timer Allen-Bradley contactor B110 OVERLOAD RELAY smp1 OVERLOAD RELAY 100-b110 interposing relay star delta wiring diagram motor start y smp1 400 vac 193-NX15 1203-SG2 schematic
Allen-Bradley starter 709

Abstract: Allen-Bradley 709 starter Allen-Bradley bulletin 712 Bulletin 709 Motor Starter Coil Allen-Bradley 800T Bulletin 509 contactor coils Allen-Bradley bulletin 509 starter Allen-Bradley 709 Allen-Bradley reduced voltage starter Allen-Bradley contactor 100
Text: , an interposing relay may be required. Specific data for long wire run applications is available from , sample unit has a 3-pole Bulletin 509 size 1 starter, a Bulletin 700P relay and a Bulletin 800T transformer type pilot light ("ON" application). In this example, the starter and relay are energized at the , volt-ampere burdens of all devices that could be sealed at one time. Device 509 size 1 starter 700P relay , device or devices: Device Inrush VA Burden 509 size 1 starter 192 700P relay 138 800T pilot light + â


OCR Scan
PDF
2011 - Not Available

Abstract: No abstract text available
Text: voltage or current is to be switched, an interposing relay circuit can be used. Figure 11 shows an example of a circuit to switch higher currents or voltages. Figure 11. Wiring an Interposing Relay to


Original
PDF
RK216

Abstract: RXMH-2 rxma1 RK 211 074 rxmh2 067 ABB RXMVB2 RXMA2 rk211 RK223 284-BA RK211
Text: interposing relay , in automatic devices and as output relay in protection relays. Type RXMM 1 is a space saving relay with two coils, each with 3 contacts for applications where few contacts are needed. Type RXMS 1 is particularly suitable as tripping relay due to its extremely short operate time. A special , ms •Up to 15 contacts on one relay I Application The relays are intended for installations where , where high disturbance immunity is required. Type RXSF 1 is a signal flag relay intended for use as


OCR Scan
PDF 1MDB08003-EN 031-AA 284-AA/-AAA 031-BA 284-BA/-BAA 32S-2S 284-AAA 1MDB13003-EN 1MDB13004-EN 1MDB14003-EN RK216 RXMH-2 rxma1 RK 211 074 rxmh2 067 ABB RXMVB2 RXMA2 rk211 RK223 284-BA RK211
2010 - bulletin 2193F

Abstract: 2100-CA001 Allen-Bradley soft starter smc-3 powerflex 753 powerflex 753 programming manual Allen-Bradley soft starter 2193M LOGIX5561 Cutler-Hammer HMCP 4 POLE 1200 AMPS MANUAL CHANGE OVER SWITCH 600V
Text: unit doors closed: · Overload detection (monitor warnings and trips) · Change overload relay setting


Original
PDF 2100-SG003A-EN-P bulletin 2193F 2100-CA001 Allen-Bradley soft starter smc-3 powerflex 753 powerflex 753 programming manual Allen-Bradley soft starter 2193M LOGIX5561 Cutler-Hammer HMCP 4 POLE 1200 AMPS MANUAL CHANGE OVER SWITCH 600V
2004 - wiring diagram contactor

Abstract: wiring diagram to hold contactor with NO, NC Allen-Bradley bulletin 1502 mitsubishi contactor JHP-70A contactor mitsubishi contactor for 3 phase Capacitors ac contactor Allen-Bradley 1502 medium voltage contactor service manual AEROSHELL 43
Text: No file text available


Original
PDF 1502-UM050C-EN-P wiring diagram contactor wiring diagram to hold contactor with NO, NC Allen-Bradley bulletin 1502 mitsubishi contactor JHP-70A contactor mitsubishi contactor for 3 phase Capacitors ac contactor Allen-Bradley 1502 medium voltage contactor service manual AEROSHELL 43
2007 - 1503VC-BMC5

Abstract: wiring diagram contactor INTELLIVAC contactor wiring diagram with timer EH 80 contactor Allen-Bradley bulletin 1500 1503VC-BMC4 1503VC relay contactor wiring diagrams Allen-Bradley bulletin 1502
Text: inputs (see Table 1.A). If the control device is not compatible consider using an interposing relay , isolating/loading these signals, as required (using interposing relays or load resistors.) Consult factory , intended to be the `Neutral', `Return', or `-' side of the control power. Status Relays Status relay , required (using interposing relays or load resistors). Consult factory for assistance, if needed. The , I/O modules with relay outputs have R-C snubber circuits across the contact to suppress voltage


Original
PDF 1503VC 1503-UM053A-EN-P 1503VC-BMC5 wiring diagram contactor INTELLIVAC contactor wiring diagram with timer EH 80 contactor Allen-Bradley bulletin 1500 1503VC-BMC4 1503VC relay contactor wiring diagrams Allen-Bradley bulletin 1502
2007 - 1503VC-BMC4

Abstract: contactor wiring diagram with timer Allen-Bradley bulletin 1500 wiring diagram contactor 1503VC-BMC3 INTELLIVAC up 1503 v timer contactor contactor 80158
Text: .A). If not compatible, consider using an interposing relay connected as shows in Figure 3.6 , . Consider means of isolating/loading these signals, as required (using interposing relays or load resistors , `Neutral', `Return', or `-' side of the control power. Status Relays Status relay connections are , required (using interposing relays or load resistors). Consult factory for assistance, if needed. The , I/O modules with relay outputs also have R-C snubber circuits across the contacts to suppress noise


Original
PDF 1503VC 1503-UM052C-EN-P 1503-UM052B-EN-P 1503VC-BMC4 contactor wiring diagram with timer Allen-Bradley bulletin 1500 wiring diagram contactor 1503VC-BMC3 INTELLIVAC up 1503 v timer contactor contactor 80158
2008 - rockwell powerflex 753 wiring diagram

Abstract: 22A D4P0N104 Powerflex User Manual Allen-Bradley 22A-D2P3N104 powerflex 753 programming manual 140M-C2E-C16 powerflex 4 22B-D010N104 22B-D024N104 22-RJ45CBL-C20 22A-A3P6N103
Text: systems. · A relay pre-charge limits inrush current. · Integral brake transistor, available on all , costs and simplify control schemes. - Timer function: Relay or opto outputs controlled by drive , Counter function: Relay or opto outputs controlled by drive performing counter function. Counter function is activated by a digital input programmed as "Counter Input." - Basic Logic: Relay or opto outputs , one (1) form C relay output can be used to indicate various drive, motor or logic conditions


Original
PDF 22-TD001G-EN-P 22-TD001F-EN-P rockwell powerflex 753 wiring diagram 22A D4P0N104 Powerflex User Manual Allen-Bradley 22A-D2P3N104 powerflex 753 programming manual 140M-C2E-C16 powerflex 4 22B-D010N104 22B-D024N104 22-RJ45CBL-C20 22A-A3P6N103
interposing CT

Abstract: abb rxdsb 4 ABB SLCE 8 RXDSB 4 ASEA BROWN BOVERI interposing current transformers RXDSB4 1MDU04007-EN ABB SLCE 16 BROWN BOVERI relay CE interposing relay
Text: relay , indicator and test switch Type SLCE interposing current transformers: •Secondary current 1 A or , balance the main CT ratios. In addition, interposing CT's,may be. relay can include up to about two , times for restrained and unrestrained operation, with RXMS 1 as the tripping relay Type SLCE interposing , per- cent of rated current, 1 A or 5 A • Unrestrained operation settable to 8,13 or 20 times relay rated current •Provided with separate interposing CT's for ratio and phase angle matching and


OCR Scan
PDF 1MDB04007-EN 1MDU04007-EN AG03-5005E interposing CT abb rxdsb 4 ABB SLCE 8 RXDSB 4 ASEA BROWN BOVERI interposing current transformers RXDSB4 ABB SLCE 16 BROWN BOVERI relay CE interposing relay
interposing CT

Abstract: abb rxdsb 4 Transformer differential protection RADSB RK 625 interposing relay interposing 1MRK 514 001-BEN RADSB RK 625 001 CC radsb RXMS 1mdu04007-en
Text: 20 times relay rated current · Provided with separate interposing CT's for ratio and phase angle , Built-in trip relay , indicator and test switch Type SLCE interposing current transformers: · Secondary , delayed V/Hz relay e.g. type RATUB which has an inverse-time operating characteristic. Interposing CT , Application The RADSB is a protective relay intended for all types of three-phase power transformers. By , connected. The relay is also well suited for generator and step-up transformer overall protection, often


Original
PDF 002-BEN SE970883) 1MDU04007-EN AG03-5005E 015-BEN 001-BEN 003-BEN interposing CT abb rxdsb 4 Transformer differential protection RADSB RK 625 interposing relay interposing 1MRK 514 001-BEN RADSB RK 625 001 CC radsb RXMS 1mdu04007-en
interposing CT

Abstract: slce capacitor interposing relay interposing 016-BEN RXSGA 1mdu04007-en interposing CT, technical 1MRK 514 001-BEN calculation of transformer differential relay setting
Text: Built-in 6 contact trip relay , phase indicator and test switch · Sensitivity can be set to 15, 20, 25 or 30% of rated current, 1 A or 5 A · Long CT secondary leads are feasible with 1 A relay · Unrestrained operation settable to 5, 10 or 15 times relay rated current Application · Separate interposing CT's may be used for ratio matching purposes · DC/DC converter with built-in loss-of-voltage , , large motors, cables and short lines, shunt and series reactors. The relay is insensitive to the DC


Original
PDF 016-BEN SE970169) 1MDU09023-EN 1MDU04007-EN 002-BEN 015-BEN 001-BEN 003-BEN interposing CT slce capacitor interposing relay interposing 016-BEN RXSGA 1mdu04007-en interposing CT, technical 1MRK 514 001-BEN calculation of transformer differential relay setting
2009 - vfd WITH BYPASS star delta wiring diagram motor

Abstract: wiring diagram slip ring motor resistance starter autotransformer starter medium voltage Schneider contactor ac dc switch telemecanique altivar 31 fault codes wiring diagram altivar 31 altivar 302
Text: . 91 Full Section Empty Mounting Units ( Relay Section , standard. Not available with neutral bus or relay sections. 20.00 508 or 20.00 12.00 508


Original
PDF 8998CT9701R07/09 1-888-SquareD 8998CT9701R7/02, vfd WITH BYPASS star delta wiring diagram motor wiring diagram slip ring motor resistance starter autotransformer starter medium voltage Schneider contactor ac dc switch telemecanique altivar 31 fault codes wiring diagram altivar 31 altivar 302
Supplyframe Tracking Pixel