The Datasheet Archive

Top Results (6)

Part ECAD Model Manufacturer Description Datasheet Download Buy Part
SN74CBT16211DGVR SN74CBT16211DGVR ECAD Model Texas Instruments 24-Bit Bus-Exchange Switch 56-TVSOP -40 to 85
SN74ALVCHR162269DL SN74ALVCHR162269DL ECAD Model Texas Instruments ALVC/VCX/A SERIES, 12-BIT EXCHANGER, TRUE OUTPUT, PDSO56
5962-9852101QXA 5962-9852101QXA ECAD Model Texas Instruments 24-BIT FET BUS-EXCHANGE SWITCHES 56-CFP -55 to 125
74ABTH162460DGGRG4 74ABTH162460DGGRG4 ECAD Model Texas Instruments ABT SERIES, 4-BIT EXCHANGER, TRUE OUTPUT, PDSO56, GREEN, PLASTIC, TSSOP-56
SN74CB3T3383DWG4 SN74CB3T3383DWG4 ECAD Model Texas Instruments CB3T/3VT SERIES, 5 2-BIT EXCHANGER, TRUE OUTPUT, PDSO24, GREEN, PLASTIC, SOIC-24
74CBT16209ADGVRE4 74CBT16209ADGVRE4 ECAD Model Texas Instruments CBT/FST/QS/5C/B SERIES, DUAL 9-BIT EXCHANGER, TRUE OUTPUT, PDSO48, GREEN, PLASTIC, TVSOP-48

heat exchanger Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
2007 - arstech

Abstract: No abstract text available
Text: efficient liquid-to-air heat exchanger with flat copper tubes and plain fins to transfer the heat to the , very low fluid permeation for long operating life. NOMENCLATURE Heat Load (W) Q Heat Exchanger , following key components: • • • • Pump Cold plates Heat Exchanger Flexible Tubing Coolant HOUSING SYSTEM FAN HEAT EXCHANGER FILL PORT PUMP FEP TUBING VGA MEMORY HEAT , BASE PLATE FIN ARRAY Figure 2 Copper Cold Plate Heat Exchanger The heat exchanger component of


Original
PDF IPACK2007 IPACK2007-33870 D2570-96 arstech
2007 - PT100 temperature sensor ABB motor

Abstract: 230v transformer sccf PT 2258 circuit diagram he250 block diagram of suction pump thread gl18 condensate pump unit motor operated valve for gas SR25
Text: Inlet Conditions Sample Gas Pressure Heat Exchanger Material Sample Gas Pressure pabs without , Inlet Temperature 140 °C Sample Gas Inlet Dew Point max. 70 °C, max. 60 °C for heat exchanger , with glass heat exchanger : GL coupling nuts with inset 6 x 4 x 1 threads for a hose or pipe (2 per heat exchanger ) The fixing brackets are fitted in the factory. 10 SCC-C Sample Gas Cooler , Connection Sample Gas and Condensate Connections Heat Exchanger Material Sample Gas Inlets and


Original
PDF
2012 - Not Available

Abstract: No abstract text available
Text: WL 1000 Liquid to Air Heat Exchanger System Innovative Technology for a Connected World WATER COOLED HEAT EXCHANGER UNITS FOR MEDICAL AND INDUSTRIAL SYSTEMS The WL1000 is a re-circulating liquid to air heat exchanger that offers dependable, compact performance by removing large amounts of , flow rate. Heat from coolant is absorbed by a radiant heat exchanger and dissipated into the ambient , Heat Exchanger System Innovative Technology for a Connected World performance curves


Original
PDF WL1000
2008 - heat exchanger

Abstract: heat and mass transfer heat exchanger process data sheet plate heat exchanger SHELL AND TUBE HEAT EXCHANGER heat exchanger process 800XA
Text: IndustrialIT System 800xA Asset Optimization Heat Exchanger Asset Monitor Data Sheet The , walls of the heat exchanger (HX), changing the HX's thermo conductivity properties. Regardless of the , Plant processes may have to be slowed down to allow the primary fluid more time in the heat exchanger , declines There are many critical issues that effect efficiency and performance of a heat exchanger , . The Heat Exchanger Asset Monitor (HXAM), identifies condition changes on any heat exchanger


Original
PDF 800xA 3BUS094354 heat exchanger heat and mass transfer heat exchanger process data sheet plate heat exchanger SHELL AND TUBE HEAT EXCHANGER heat exchanger process 800XA
2012 - Not Available

Abstract: No abstract text available
Text: WL 500 Liquid to Air Heat Exchanger System Innovative Technology for a Connected World WATER COOLED HEAT EXCHANGER UNITS FOR MEDICAL AND INDUSTRIAL SYSTEMS The WL500 is a re-circulating liquid to air heat exchanger that offers dependable, compact performance by removing large amounts of , flow rate. Heat from coolant is absorbed by a radiant heat exchanger and dissipated into the ambient , CLV-customerservice@lairdtech.com www.lairdtech.com/thermal TM WL 500 Liquid to Air Heat Exchanger System Innovative


Original
PDF WL500
2012 - Not Available

Abstract: No abstract text available
Text: WL 3000 Liquid to Air Heat Exchanger System Innovative Technology for a Connected World WATER COOLED HEAT EXCHANGER UNITS FOR MEDICAL AND INDUSTRIAL SYSTEMS The WL3000 is a re-circulating liquid to air heat exchanger that offers dependable, compact performance by removing large amounts of , flow rate. Heat from coolant is absorbed by a radiant heat exchanger and dissipated into the ambient , Heat Exchanger System Innovative Technology for a Connected World performance curves


Original
PDF WL3000
three phase bridge inverter in 180 degree and 120

Abstract: single phase half controlled full wave bridge rec transformer calculation formula AN-305 three phase bridge inverter 120 degree ac to dc inverter by thyristor power semiconductor 1973 thyristor st 103
Text: fluid, such as: 1. Thermal resistance from case to heat exchanger (often referred to as case to heat sink). 2. Thermal resistance from heat exchanger to cooling fluid. Thermal resistance from case to heat exchanger is a function of the size of the thyristor base and presence or absence of silicone , Exchanger Size of Thyristor Case Thermal Resistance to Heat Exchanger Hex Base Threaded Stud JEDEC No , resistance from heat exchanger to cooling fluid must be determined from the configuration and size of the


OCR Scan
PDF AN-305 three phase bridge inverter in 180 degree and 120 single phase half controlled full wave bridge rec transformer calculation formula AN-305 three phase bridge inverter 120 degree ac to dc inverter by thyristor power semiconductor 1973 thyristor st 103
2008 - heat exchanger

Abstract: SHELL AND TUBE HEAT EXCHANGER heat exchanger process data sheet shell and tube heat exchanger process heat exchanger process
Text: IndustrialIT System 800xA Asset Optimization Heat Exchanger Asset Monitor Data Sheet The , walls of the heat exchanger (HX), changing the HX's thermo conductivity properties. Regardless of the , Plant processes may have to be slowed down to allow the primary fluid more time in the heat exchanger , . The Heat Exchanger Asset Monitor (HXAM), identifies condition changes on any heat exchanger , training, permit the HXAM to continuously monitor heat exchanger performance over the long term


Original
PDF 800xA 3BUS094354 heat exchanger SHELL AND TUBE HEAT EXCHANGER heat exchanger process data sheet shell and tube heat exchanger process heat exchanger process
2012 - Not Available

Abstract: No abstract text available
Text: WL 2000 Liquid to Air Heat Exchanger System Innovative Technology for a Connected World WATER COOLED HEAT EXCHANGER UNITS FOR MEDICAL AND INDUSTRIAL SYSTEMS The WL2000 is a re-circulating liquid to air heat exchanger that offers dependable, compact performance by removing large amounts of , flow rate. Heat from coolant is absorbed by a radiant heat exchanger and dissipated into the ambient , Heat Exchanger System Innovative Technology for a Connected World performance curves


Original
PDF WL2000
c45 scr

Abstract: 2000A thyristor scr prx scr 02AM
Text: EXCHANGERS) M O O NOTE: TYPICALLY THE DEVICE TO . · HEAT EXCHANGER THERMAL RESIST- j ANCE B 0.005` C/W. THIS MUST 8 t -AOOEO TO THE HEAT EXCHANGER - SJHERMAL RESISTANCE TO OET DiVICE ^XTO AM BC Nr THERMAL RESISTANCE. NOTE! TYPICALLY THE DEVICE TO I " HEAT EXCHANGER THERMAL RESIST- " I ANCE IS O.OOS*C/W. THIS MUST BE *.OOED TO THE HEAT EXCHANGER " I DERMAL RESISTANCE TO GET^OEVICEJ JO AMBIENT1 THERMAL RESISTANCE , EXCHANGER THERMAL RESIST- " ANCE IS 0.005'C/W; THIS MUST BE ADDED TO THE HEAT EXCHANGER THERMAL RESISTANCE


OCR Scan
PDF 00030e DurandBP107, Amperes/500-1800 MAX/10 c45 scr 2000A thyristor scr prx scr 02AM
2015 - hydrosink

Abstract: No abstract text available
Text: , heat exchanger , small tank, Bologna Design Center EUDC@aavid.com : a smart and more efficient , single components, the biggest one (in terms of dimensions) is the heat exchanger ; it is a common , customer’s cabinet, with remote location for pump and heat exchanger ; otherwise, it is possible to have , material compatibility issues: as the heat exchanger is a full aluminum one, the flow path must be made , liquid cold plate (LCP) and of the heat exchanger (HEX): Both parameters have the same relevance: if


Original
PDF 97/23/EC hydrosink
2012 - Not Available

Abstract: No abstract text available
Text: WL 5000 Liquid to Air Heat Exchanger System Innovative Technology for a Connected World WATER COOLED HEAT EXCHANGER UNITS FOR MEDICAL AND INDUSTRIAL SYSTEMS The WL 5000 is a re-circulating liquid to air heat exchanger that offers dependable, compact performance by removing large amounts of , flow rate. Heat from coolant is absorbed by a radiant heat exchanger and dissipated into the ambient , Heat Exchanger System Innovative Technology for a Connected World performance curves


Original
PDF
2015 - Not Available

Abstract: No abstract text available
Text: air through a horizontally arranged heat exchanger . One or multiple axial fans extract outside air through a heat exchanger arranged in V-form. Challenge Challenge Outside air is sucked through a heat exchanger . The condenser, with a horizontally arranged exchanger , has an axial fan with , heat exchanger . This results in the air inflow being disturbed. If multiple fans are used in one condenser, the uneven air inflow becomes stronger. Due to the size of the heat exchanger , the


Original
PDF
2012 - Not Available

Abstract: No abstract text available
Text: WL 1500 Liquid to Air Heat Exchanger System Innovative Technology for a Connected World WATER COOLED HEAT EXCHANGER UNITS FOR MEDICAL AND INDUSTRIAL SYSTEMS The WL1500 is a re-circulating liquid to air heat exchanger that offers dependable, compact performance by removing large amounts of , flow rate. Heat from coolant is absorbed by a radiant heat exchanger and dissipated into the ambient , CLV-customerservice@lairdtech.com www.lairdtech.com/thermal TM WL 1500 Liquid to Air Heat Exchanger System Innovative


Original
PDF WL1500
2011 - Peltier Thermo

Abstract: No abstract text available
Text: ² °C] S [m²] ∆Tsolid/Tfluid [°C] The surface of the heat exchanger with surrounding air is mainly defined by the power to extract The volume of the heat exchanger is generating the pressure drop , convection Therefore all other solutions are only used to transfer the heat to the heat exchanger The , Solution Solutions Division Limited distance between heat source and heat exchanger (< 1m) Start up , Fluid Power Thermal Solution Solutions Division The current water to air heat exchanger is


Original
PDF
2007 - Not Available

Abstract: No abstract text available
Text: transfer from the top wall. The heat exchanger system consisted of two parallel heat pipes with condenser , a heat coating (plain aluminium finish). These coatings were selected exchanger . based on their , coated surface can also be very effective. The case having a white coated enclosure with heat exchanger , through the heat exchanger . In the cases of doublewalled enclosure and radiation shield there isn’t any , Transfer mechanism inside enclosure with heat exchanger system 80 N C _S L N C _L V N C _W


Original
PDF Ph-91-20-66030625 Fax-91-20-66030626 Pune-411005,
1998 - Not Available

Abstract: No abstract text available
Text: the TNETX3150 as an example The following procedure is used to determine if a heat exchanger is , device requires a heat exchanger . If the ambient air temperature (Ta) exceeds | 78qC with an airflow of 100 FPM, the device requires a heat exchanger . If 85 qC still air is all that is available to cool , calculate the maximum temperature the device may encounter and the value of the heat exchanger required to , environment is within tolerance. If the thermal environment is out of tolerance, the rating of a heat


Original
PDF SPWA017
2003 - bottle filling circuit diagram

Abstract: Uras14 AO2000 Limas11 AEROSOL FLAMMABLE CORROSIVE wiring diagram for water pump motor PT100 connected diagram condensate water tank H2O2 dosing for analyzer protection kiln TEMPERATURE CONTROL
Text: Description Analysis Cabinet Probe Retractor Control Box Heat Exchanger Pneumatic and Electric , rpm-regulated heat exchanger · Cooling water system monitoring with temperature, flow rate and pressure , ACK Advance Cement Kiln Operator's Manual 11 Heat Exchanger Figure 4 1 2 Heat Exchanger , outlet Drain Heat exchanger motor ACK Advance Cement Kiln Operator's Manual 42/23-54 EN Rev. 2 , Heat Exchanger Probe H Probe Retractor Analysis Cabinet Control Box Pneumatic and


Original
PDF
APPLICATIONS OF dc chopper circuit

Abstract: ac to dc chopper transformer ANSI 45 rectifier 1/Varo integrated rectifiers chopper transformer
Text: section of the system and may be cooled by forced air, direct water cooling or use of a heat exchanger , – convection, forced air, direct water or via a heat exchanger system • Enclosures NEMA 1, 3R , methods. These include forced air, direct water, or combination of closed loop heat exchanger systems , loop de-ionized water to water heat exchanger , while the ambient and dry-type transformers are cooled by the air to water heat exchanger . Sealed Air To Liquid Cooled When portions of the


Original
PDF
Not Available

Abstract: No abstract text available
Text: dew point is reached, then moisture in the air will condense onto the cold side heat exchanger , Cooler in a vertical orientation, so condensation runs off the cold side heat exchanger . If the , angle in horizontal orientation to allow for condensation to run off the cold side heat exchanger . The , heat exchanger . Reference the below diagram for mounting hole locations and cold side heat exchanger dimensions. The cut out should be 2.5 mm’s larger than the cold side heat exchanger . Six mounting holes


Original
PDF AA-250-XX
2007 - intel 965 motherboard circuit diagram

Abstract: intel 775 motherboard diagram 775 MOTHERBOARD CIRCUIT diagram D975XBX2 intel lga775 MOTHERBOARD pcb CIRCUIT diagram LGA775 SOCKET PIN LAYOUT hand movement based fan speed control computer motherboard circuit diagram lga775 PC MOTHERBOARD intel 815 circuit diagram LGA775 socket design guidelines
Text: ® ALCT Reference Design Major Components .56 17. Heat Exchanger Fan , .57 19. Diagram of Location of Heat Exchanger VR and Socket Airflow Cooling 20. Processor Maximum Current Draw for Heat Exchanger Fan Speed .59 21. Intel® Quiet , component specification. Working fluid temperature as it leaves the pump (or enters the heat exchanger ). , QX6800, an active liquid-cooled design, should be designed to manage the heat exchanger inlet


Original
PDF QX6800 intel 965 motherboard circuit diagram intel 775 motherboard diagram 775 MOTHERBOARD CIRCUIT diagram D975XBX2 intel lga775 MOTHERBOARD pcb CIRCUIT diagram LGA775 SOCKET PIN LAYOUT hand movement based fan speed control computer motherboard circuit diagram lga775 PC MOTHERBOARD intel 815 circuit diagram LGA775 socket design guidelines
44In42Sn14Cd

Abstract: ASM800 heat exchanger heat sink heat sink for power diode CW laser diode 808 nm CW Laser laser diode array indalloy 8
Text: SILVER BULLET • Packaged Laser Diode Bar • Easily Soldered To A Heat Exchanger 20W CW , inch Au overTIW barrier Soldering'151 Detailed Instructions Provided Heat Exchanger Capacity'71 45W Heat Exchanger Thermal Resistance <0.25°C-cm2/W NOTES: 5.A dry nitrogen environment should be , °C Heat Sink1" 20 . . w Operating Current 20W at 25°C Heat Sink . 25 30 A Threshold Current 25°C Heat Sink . 5.5 8.0 A Slope Efficiency 25°C Heat Sink 0.95 1.05 . W/A Efficiency 20W at 25Â


OCR Scan
PDF a06rm Emitters121 Size121 Pitch12' Tolerance01 44In42Sn14Cd ASM800 heat exchanger heat sink heat sink for power diode CW laser diode 808 nm CW Laser laser diode array indalloy 8
2008 - ac drives ls 600 manual

Abstract: 20-HIM-A3 20D-STEG-B1 20-HIM-A3 Fault codes 20-HIM-A3 powerflex BAY38 ac drives ls 600 manual programming 20D-P2-ENC0 20D-DL2-ENET0 rockwell powerflex 750 series wiring diagram
Text: PowerFlex 700L Liquid-to-Liquid Heat Exchanger User Manual Wiring and Grounding Guidelines for Pulse Width , · The PowerFlex 700L Liquid-to-Liquid Heat Exchanger provides customers a cost effective, standard cooling loop solution for use with the PowerFlex 700L drive. The liquid to liquid heat exchanger utilizes , supply from the user. · A chiller or liquid to air heat exchanger can also be used with the PowerFlex , patented liquid-cooled heatsink design to transfer over 80% of the drive heat loss to the liquid coolant


Original
PDF 20L-TD001A-EN-P ac drives ls 600 manual 20-HIM-A3 20D-STEG-B1 20-HIM-A3 Fault codes 20-HIM-A3 powerflex BAY38 ac drives ls 600 manual programming 20D-P2-ENC0 20D-DL2-ENET0 rockwell powerflex 750 series wiring diagram
2015 - Not Available

Abstract: No abstract text available
Text: and amplifier components are all located in the rack. Only the compact heat exchanger needs to be , (47.24 in × 80.71 in × 45.28 in) Mechanical specifications of heat exchanger (indoor, floor , Electrical specifications of heat exchanger Nominal operating voltage range Current at 230 V Power , ) Coolant Heat exchanger capacity 3000 W model max. 9.5 kW 10 000 W model max. 41 , altitude Recommended distance between amplifier system and heat exchanger max. 20 m outside


Original
PDF BBL200 v0101 BBL200
2000 - ASM940-40

Abstract: australia heat sink ASM01C020 ASM02C040 ASM05C055 ASM940-20 CW laser diode
Text: · Packaged 1, 2, 3 Bar Laser Diode Array · Easily Soldered to a Heat Exchanger · Available , DIMENSIONS Metalization Soldering (4) Heat Exchanger Capacity (5) Heat Exchanger Thermal Resistance , diode bars on a BeO substrate. These modules can be either mounted on customer supplied heat exchangers or on a variety of heat exchangers offered by IMC. For customers who wish to build their own , prescreened according to customer supplied specification before being mounted on heat exchangers. Laser diode


Original
PDF 940nm 785-1064nm laser2000 ASM940-40 australia heat sink ASM01C020 ASM02C040 ASM05C055 ASM940-20 CW laser diode
Supplyframe Tracking Pixel