gordos relays

Abstract: gordos relay gordos relay 4705 gordos 4705
Text: a Crouzet REED RELAYS 47 SERIES MINI-SIP DRY REED RELAY 74 SERIES SIP DRY REED RELAY FEATURES: ■These Gordos Relays are molded in semiconductor-grade molding compounds that meet Underwriters Laboratories 94V-0 flammability rating. ■Compatible with automatic insertion ■Logic Compatible 1 , Operating temp range -20°C to 85°C Storage temp range -20°C to 100°C REED RELAY SELECTION CHART , . 4705 Yes 12 C ontact Arrangem ent Schem atic (Side View) + 3 -5 Part N um ber 200


OCR Scan
PDF 741C-1 741C-2 gordos relays gordos relay gordos relay 4705 gordos 4705
CLARE PRMA1A05

Abstract: gordos relay clare mercury mercury-wetted contact relay DSS41A05 DSS41A05B PRMA1A05 clare hamlin mercury relay clare mercury-wetted relay gordos 741a PRMA2A05B
Text: 107DIP 171DIP RELAY SERIES L W H 0.290 x 0.280 x 0.750 L W H 0.275 X 0.300 X 0.750 L W H , RELAYS/COAXIAL RELAYS 134 MPCX MERCURY WETTED 102VX & 102HVX 120 COAXIAL RELAY SERIES L W , APPLICATION DATA HOW REED RELAYS WORK The term reed relay covers dry reed relays and mercurywetted contact , Dry reed relays have become an important factor in the relay field. They have the advantage of being , this type of reed relay are the freezing point of mercury (-38°C), poor resistance to shock and


Original
PDF 117SIP 107DIP 171DIP FEATDIP-35 721E0510 W172DIP-37 721E1210 W172DIP-38 721E2410 CLARE PRMA1A05 gordos relay clare mercury mercury-wetted contact relay DSS41A05 DSS41A05B PRMA1A05 clare hamlin mercury relay clare mercury-wetted relay gordos 741a PRMA2A05B
G280A25

Abstract: G240D25 GA52D10 GA5-4D10 G480D G280A45 GA5-4D25 GA5-6D25 G280D10 G480d50
Text: GORDOS SOLID STATE RELAYS G SERIES POWER RELAYS GA5 SERIES POWER RELAYS ■Back-to-back (dual) SCR output for severe inductive loads. ■Economical triac output for general purpose , SOLID STATE RELAYS GORDOS SOLID STATE RELAYS G, GA5 SERIES POWER RELAYS G SERIES MODEL NUMBER , / TEL: 800-643-3500 / 501-636-5000 / FAX: 501-636-2305 61 GORDOS SOLID STATE RELAYS G, GA5 SERIES , impedance (drop). At 60 Hz 100/j.s for random turn-on (suffix "R") models. With relay properly mounted on


OCR Scan
PDF E46203, E79183) 100/j G460D G575D G280A25 G240D25 GA52D10 GA5-4D10 G480D G280A45 GA5-4D25 GA5-6D25 G280D10 G480d50
Section 8

Abstract: PRMA1A12 DSS41A05B DSS41A05 HE3621A0510 DSS41A12 gordos relay DSS41A24B HE3621A2410 dss41a12b
Text: Application Data Introduction: In the past several years the dry reed relay has become an important product among relay specifiers, primarily because of the tremendous increases in low level switching for computers, business machines, and communication appliances. The dry reed relay has the great advantage of , long life. How Reed Relays Work: The basic element of the reed relay is the glass reed capsule , operation, which enables the reed relay to be driven by low cost IC's. · Small Physical Size · High


Original
PDF W49E1C1VG-24DC-SCO W49E1C1VW-5DC-SCO W49E1C1VW-12DC-SCO W49E1C1VW-24DC-SCO 653-3K 653-6K 653-12K 603-6B 603-12B 603-24B Section 8 PRMA1A12 DSS41A05B DSS41A05 HE3621A0510 DSS41A12 gordos relay DSS41A24B HE3621A2410 dss41a12b
gordos relays

Abstract: Gunther - Reed Relays ziatech intel 74LS244 rm65 grigsby 8031 Intel Microprocessor SDK-51 74LS244 uses and functions gunther reed SWITCH
Text: Gordos VSC Versatile Serial Control Systems GORDOS A CORPORATIONÆL GORDOS A CORPORATION ÆÀ Gordos VSC Versatile Serial Control Systems VSC-TR Translator Repeater Card Economical, real-world power I/O control and data acquisition capability for your existing computer system. The Gordos VSCTM , as an interface between your existing computer and Gordos industry-standard input/output modules, the , user. The Gordos VSC-311 " can also be used as an 8031 processor card on the STD bus with full serial


OCR Scan
PDF BP002 gordos relays Gunther - Reed Relays ziatech intel 74LS244 rm65 grigsby 8031 Intel Microprocessor SDK-51 74LS244 uses and functions gunther reed SWITCH
gordos relay

Abstract: gordos 831A gordos 832a2 GORDOS 831C-1 gordos 831A-5 gordos relay 831 gordos 832a 832A-4 relay gordos relay 831c3 831A-2
Text:  GORDOS REED RELAYS 83 SERIES MOLDED DIP THRU-HOLE THRU-HOLE 14 13 9 8 rçJl3_C3-1—i r—i LlU U L-J ^ 12 6 7 SURFACE MOUNT DRY REED RELAYS FEATURES: ■Choice of Gull or J-Lead Surface Mount or Thru-hole Configuration ■Surface Mount Versions Pass High Reliability Steam Aging , GORDOS REED RELAYS 83 SERIES MOLDED DIP THRU-HOLE AND SURFACE MOUNT DRY REED RELAYS Nominal Coil , Suppressed 0.5 0.5 1.5 includes Bounce on N.C. Pole REED RELAY SELECTION CHARTshad/ng denotes shortest lead


OCR Scan
PDF 32A-4J 32A-5 32A-6 32A-5G 32A-6G 32A-5J 32A-6J gordos relay gordos 831A gordos 832a2 GORDOS 831C-1 gordos 831A-5 gordos relay 831 gordos 832a 832A-4 relay gordos relay 831c3 831A-2
836C-2

Abstract: GORDOS 831C-1 gordos relays
Text: GORDOS REED RELAYS 83 SERIES MOLDED DIP THRU-HOLE AND SURFACE MOUNT DRY REED RELAYS FEATURES: ■Choice of Gull or J-Lead Surface Mount or Thru-hole Configuration ■Surface Mount Versions Pass High Reliability Steam Aging Solderability Test ■Surface Mount Versions Compatible with IR Reflow Systems â , : 800-643-3500 / 501-636-5000 / FAX: 501-636-2305 80 GORDOS REED RELAYS 83 SERIES MOLDED DIP THRU-HOLE AND , Suppressed 0.5 0.5 1.5 includes Bounce on N.C. Pole REED RELAYS REED RELAY SELECTION CHART


OCR Scan
PDF
1998 - gordos relay

Abstract: a 1712 8pin gordos relay 4705 gordos 4705 "Current to Voltage Converter" COMPONENT RESEARCH ALD2301 picoammeter ALD1712 relay gordos 8
Text: 1 & 2 are of type 4705 , Gordos Corporation. ALD1712A/ALD1712B ALD1712 1.5V VIN = dt ALD1712 3 8 0.1 V = 1/RC Control 1 - 1 +5V Relay 2 VIN 1/2 ALD2301 5V 2 , INTEGRATOR INTEGRATOR VOLTAGE PRESET 20K 20K 5V Relay 1 2 R 7 - t2 + 3 +


Original
PDF ALD1712A/ALD1712B ALD1712 ALD1712 300mV ALD2301 K11B104KSW gordos relay a 1712 8pin gordos relay 4705 gordos 4705 "Current to Voltage Converter" COMPONENT RESEARCH ALD2301 picoammeter relay gordos 8
2005 - gordos relay 4705

Abstract: gordos relay gordos 83 picoammeter ALD1712 ALD2301 k11b Gordos* relay
Text: specified. · RELAYS 1 & 2 are of type 4705 , Gordos Corporation. ALD1712A/ALD1712B ALD1712 1.5V VIN = dt ALD1712 3 8 0.1 V = 1/RC Control 1 - 1 +5V Relay 2 VIN 1/2 , CONSTANT INTEGRATOR INTEGRATOR VOLTAGE PRESET 20K 20K 5V Relay 1 2 R 7 - t2 +


Original
PDF ALD1712A/ALD1712B ALD1712 ALD1712 300mV ALD2301 K11B104KSW gordos relay 4705 gordos relay gordos 83 picoammeter ALD2301 k11b Gordos* relay
2010 - ALD1712

Abstract: ALD1712APAL ALD1712A CMOS Advanced Linear Devices gordos relay 4705 gordos relay gordos 4705 a 1712 8pin COMPONENT RESEARCH
Text: of type 4705 , Gordos Corporation. ALD1712A/ALD1712B ALD1712 1.5V VIN = dt ALD1712 3 8 0.1 V = 1/RC Control 1 - 1 +5V Relay 2 VIN 1/2 ALD2301 5V 2 C , INTEGRATOR VOLTAGE PRESET 20K 20K 5V Relay 1 2 R 7 - t2 + 3 + 5V 4 6


Original
PDF ALD1712A/ALD1712B ALD1712 ALD1712A/ALD1712B/ALD1712 300mV ALD1712 ALD1712APAL ALD1712A CMOS Advanced Linear Devices gordos relay 4705 gordos relay gordos 4705 a 1712 8pin COMPONENT RESEARCH
2010 - a 1712 8pin

Abstract: No abstract text available
Text: specified. • RELAYS 1 & 2 are of type 4705 , Gordos Corporation. ALD1712A/ALD1712B ALD1712 1.5V VIN = dt ALD1712 3 8 0.1 V = 1/RC Control 1 - 1 +5V Relay 2 VIN 1/2 , CONSTANT INTEGRATOR INTEGRATOR VOLTAGE PRESET 20K 20K 5V Relay 1 2 R 7 - t2 +


Original
PDF ALD1712A/ALD1712B ALD1712 ALD1712A/ALD1712B/ALD1712 300mV a 1712 8pin
gordos relay

Abstract: Gordos RTI-1282 OPTO-22 RTI-1280 RTI Electronics
Text: Three 8-Bit Read/Write Ports Control 24 Bidirectional Lines Compatible to Industry Standard I/O Relay Rack (OPTO-22, Gordos ) GENERAL Low Power CMOS Design Compatible to all CMOS STD CPU Cards Memory


Original
PDF RTI-1280 16SE/8D 12-Bit RTI-1281 RTI-1282 4-20mA gordos relay Gordos OPTO-22 RTI Electronics
GF200D10

Abstract: No abstract text available
Text: GORDOS SOLID STATE RELAYS DC OUTPUT SOLID STATE RELAYS GF SERIES FET OUTPUT GT SERIES TRANSISTOR OUTPUT ■Long Life Switching of DC Loads to 30 A ■10 |xA Leakage Current Permits Reliable Switching of Sensitive Devices ■Milliohm On-Resistance Minimizes Voltage Drop, Heat Dissipation â , 72756 USA / TEL: 800-643-3500 / 501-636-5000 / FAX: 501-636-2305 66 GORDOS SOLID STATE RELAYS DC , GORDOS SOLID STATE RELAYS GF, GT THERMAL DISSIPATION CURVES (refer to heat transfer/heat sink


OCR Scan
PDF GF100D15 GF50D30 GF200D10 GT60D10 GF200D10
gordos 4705

Abstract: Gordos relays 12v precision rail to rail operational amplifier
Text: . RELAYS 1 & 2 are of type 4705 , Gordos Corporation. Advanced Linear Devices ALD1 712A/ALD1712B


OCR Scan
PDF ALD1712A/ALD1712B ALD1712 ALD1712 -300m 4000pF 12A/ALD1712B gordos 4705 Gordos relays 12v precision rail to rail operational amplifier
MMS205

Abstract: r50e2y1 CLARE PRMA1A05 MMS-205 gordos relay Aromat DPDT Single Coil 5v latching relay DSS41A05B 721C2410 Transistor B556 B556
Text: 6.3 REED RELAYS APPLICATION DATA HOW REED RELAYS WORK The term reed relay covers dry reed , by simply reversing the relay coil polarity to close the switch, or by employing a second coil with , factor in the relay field. They have the advantage of being hermetically sealed and resistant to , relay coil. In typical true SPDT designs, the armature is mechanically tensioned against the normally , that position when coil power is removed from the relay coil. 9/04 6.4 ELECTRICAL


Original
PDF 117SIP 107DIP 171DIP 172DIP 102VX/HVX 117SIP, 107DIP, 171DIP/172DIP 102VX 102HVX MMS205 r50e2y1 CLARE PRMA1A05 MMS-205 gordos relay Aromat DPDT Single Coil 5v latching relay DSS41A05B 721C2410 Transistor B556 B556
1993 - AD2421-001

Abstract: Gordos AD2421-000 VMIVME-2528 VMIVME-1110 VMIC vmic 2120 AD242 PB32HQ AD2422-200
Text: -, 24-, and 32-channel digital OPTO 22, Gordos , or Crydom mounting racks · Allows VMIC digital input boards such as the VMIVME-1110, -1111, or -1181 to interface with OPTO 22, Gordos , or Crydom signal , interface with OPTO 22, Gordos , or Crydom signal conditioning input or output modules · Allows VMIC digital I/O boards such as the VMIVME-2510B, -2532A, or -2534 to interface with OPTO 22, Gordos , or , , Gordos , or Crydom. This will simplify system wiring, which will reduce wiring errors. Since VMIC


Original
PDF VMIACC-AD242X 32-channel VMIVME-1110, VMIVME-2120 -2170A VMIVME-2510B, -2532A, locateL-AC2316 64-WIRE 16-CHANNEL AD2421-001 Gordos AD2421-000 VMIVME-2528 VMIVME-1110 VMIC vmic 2120 AD242 PB32HQ AD2422-200
Gordos SSR

Abstract: gordos relays
Text: GORDOS SOLID STATE RELAYS DC OUTPUT SOLID STATE RELAYS GF SERIES FET OUTPUT GT SERIES TRANSISTOR OUTPUT ■Long Life Switching of DC Loads to 30 A ■10 (xA Leakage Current Permits Reliable Switching of Sensitive Devices ■Milliohm On-Resistance Minimizes Voltage Drop, Heat Dissipation â , / TEL: 800-643-3500 / 501-636-5000 / FAX: 501-636-2305 66 SOLID STATE RELAYS GORDOS SOLID STATE , ., ROGERS, AR 72756 USA / TEL: 800-643-3500 / 501-636-5000 / FAX: 501-636-2305 67 GORDOS SOLID STATE


OCR Scan
PDF GF100D15 GF50D30 GF200D1C GT60D10 Gordos SSR gordos relays
Not Available

Abstract: No abstract text available
Text: in |iF unless otherwise specified. • RELAYS 1 & 2 are of type 4705 , Gordos Corporation


OCR Scan
PDF ALD1712A/ALD1712B ALD1712 ALD1712 4000pF K11B104KSW 00G0374
LR84997

Abstract: gordos relay WRC4 1781-IB5S 1781-OB5S 1781-OM5M gordos relay IAC5 gordos relay oac5r g4 oac5a 1781-oa5s
Text: Output Zero Cross Output Zero Cross Output N.O. Relay N.O. Relay N.O. Relay N.C. Relay N.C. Relay N.C. Relay Switch Input/output Switch Input/output Switch Input/output N.O. Watchdog Timer N.C. Watchdog Timer Input Input Input Input Input Output Output Output Output N.O. Relay N.C. Relay , 24-280 V ac 24-480 V ac 24-480 V ac 24-480 V ac Relay Relay Relay Relay Relay Relay n/a n/a n/a N.O. Relay N.C. Relay 90-140 V ac/dc 3.3-32 V dc 180-280 V ac/dc 10-60 V ac/dc 3.3-32 V dc


Original
PDF OPTO-22 LR84997 gordos relay WRC4 1781-IB5S 1781-OB5S 1781-OM5M gordos relay IAC5 gordos relay oac5r g4 oac5a 1781-oa5s
gordos relay

Abstract: 1702B Gordos relays 12v ALD1702 C1987
Text: are of type 4705 , Gordos Corporation. This Material Copyrighted By Its Respective Manufacturer


OCR Scan
PDF ALD1702A/ALD1702B 702/ALD1703 ALD1702/ CL-4000pF 0111F R-10K ALD2301 K11B104KS gordos relay 1702B Gordos relays 12v ALD1702 C1987
BERG strip connector

Abstract: Gordos edge connector 22 edge connector 22 pin edge connector 14 pin BERG strip connector male BERG strips BERG 21 pin connector
Text: DIGITAL I/O MODULE MOUNTING BOARDS FOR 0.6 INCH MODULES (Compatible with "SM" Series Modules) PB8 SCREW TERMINAL LOGIC SUPPLY BARRIER STRIP 6-32 SCREW TERMINAL POWER BARRIER STRIP (see note 2) 8.0 (203,2) DIMENSIONS: INCHES (MILLIMETERS) TOLERANCE:+0.020 ( + 0,50) - 7.5 (190,5) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 - + REPLACEABLE 5 AMP LINE FUSE (8) (see note 4) GORDOS DIGITAL I/O MODULES SOLD SEPERATELY 0.3 (7,6) 0 1 2 3 4 5


Original
PDF
ASX 12 D transistor

Abstract: Grayhill 70s2-04-c-03-v transistor dtx 360 mosfet transistor dtx 360 mosfet dtx 360 S505-0SJ625-000 GORDOS SOLID STATE RELAY gordos relay all mosfet dtx 360 ssr grayhill
Text: STATE RELAYS 6 (ASX) SSRDIN 6 (DSX) RELAY SERIES L.E.D. STATUS LAMP L.E.D. STATUS LAMP , F " & " M " STYLES RELAY SERIES DC INPUT DC INPUT L W H 2.20 x 1.00 x 0.85 DC INPUT , : APPLICATION AND SELECTION CRITERIA FOR SOLID STATE RELAYS: SOLID STATE RELAY (SSR) is a relay with , is applied to the input of the SSR, the relay is energized by a light emitting diode. The light , NOMINAL LOAD CURRENT: Initially select a relay whose current rating exceeds the normal load current


Original
PDF SUP2410 240D10 70S2-03-C-25-S S505-0SJ625-000 D2425/NTD2425 120D25/240D25 ASX 12 D transistor Grayhill 70s2-04-c-03-v transistor dtx 360 mosfet transistor dtx 360 mosfet dtx 360 S505-0SJ625-000 GORDOS SOLID STATE RELAY gordos relay all mosfet dtx 360 ssr grayhill
3-pin interconnect strip

Abstract: j1 male connector pin
Text: ) SIGNAL INPUT/OUTPUT 50 CONDUCTOR MALE PIN CONNECTOR (see note 1) GORDOS DIGITAL I/O MODULES SOLD


Original
PDF
Not Available

Abstract: No abstract text available
Text: capacitance values are in jiF unless otherwise specified. ►RELAYS 1 & 2 are of type 4705 , Gordos


OCR Scan
PDF ALD1702A/ALD1702B ALD1702/ALD1703 ALD1702/ ALD1703 K11B104KSW
BERG STRIP female

Abstract: BERG strip connector BERG female connector Gordos
Text: AC INPUT DC INPUT AC OUTPUT DC OUTPUT 22 3.75 (95,3) 0.5 (12,7) GORDOS DIGITAL I/O


Original
PDF PB24M BERG STRIP female BERG strip connector BERG female connector Gordos