The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
LF198S Linear Technology IC SAMPLE AND HOLD AMPLIFIER, PDSO, Sample and Hold Circuit
LF198AJ8 Linear Technology IC SAMPLE AND HOLD AMPLIFIER, CDIP8, Sample and Hold Circuit
LF198AS Linear Technology IC SAMPLE AND HOLD AMPLIFIER, PDSO, Sample and Hold Circuit
LF198AN8 Linear Technology IC SAMPLE AND HOLD AMPLIFIER, PDIP8, Sample and Hold Circuit
LF198J8 Linear Technology IC SAMPLE AND HOLD AMPLIFIER, CDIP8, Sample and Hold Circuit
LT1490AIS8#TRA1PBF Linear Technology Dual and Quad Micropower Rail-to-Rail Input and Output Op Amps

glenair fittings and entraco conduit Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
2002 - entraco

Abstract: Glenair entraco glenair fittings and entraco conduit Glenair 06324 MIL-STD-1344 mil-c-81511 Glenair MIL-C-28840 MS3400 Glenair BRAID
Text: Conduit Systems Glenair FIRST Fittings and Adapters for Series 75 Metal-Core Conduit (750-145 , ) Conduit System consists of easily installed, two-piece conduit fittings and Glenair 's Series 75 metal , Glenair FIRST Fittings and Adapters for Series 75 Metal-Core Conduit (750-145 & 750-147) Testing , sample of an Entraco fitting mated with Glenair conduit and visa versa will be subjected to Shielding , Entraco Conduit with Glenair Fittings , Glenair Conduit with Entraco Fittings Sulfur Dioxide Salt Fog


Original
PDF 717-148-AB entraco Glenair entraco glenair fittings and entraco conduit Glenair 06324 MIL-STD-1344 mil-c-81511 Glenair MIL-C-28840 MS3400 Glenair BRAID
entraco

Abstract: glenair fittings and entraco conduit Glenair entraco entraco AX M26482 tube conduit Cross Reference AX0-851-YYXX-SP M24758 M24235
Text: -2 Series Conduit Fittings and one M24758-24 Series Adapter. GLENAIR PART NUMBER M24758-X Entraco , Entraco to Glenair MIL-PRF-24758A Cross Reference Entraco is a registered trademark of Smiths Industries, Icore Division Entraco to Glenair Cross Reference CONDUIT ENTRACO PART NUMBER CC 249 - XX CC 261 - XX ENTRACO PART NUMBER (1/32 In. Increments) DECIMAL ID (Inch) CONDUIT , CONDUIT SIZE: See Page 1 M24235 SIZE 32 AX#685-YYXX=SP STUFFING TUBE SIZE 28 ENTRACO


Original
PDF MIL-PRF-24758A M24758-24X M24758-2 M24758-24 M24758-X Refere8-20 765-MWW-YYXX M28840 M22992 M26500 entraco glenair fittings and entraco conduit Glenair entraco entraco AX M26482 tube conduit Cross Reference AX0-851-YYXX-SP M24758 M24235
2002 - entraco

Abstract: glenair fittings and entraco conduit Glenair entraco entraco fittings CONDUIT
Text: Conduit Systems Glenair FIRST Fittings and Adapters for Series 75 Metal-Core Conduit (750-145 , Anti-Decoupling Springs T he Glenair Field Installable and Repairable Shipboard Termination (FIRST) Conduit System consists of easily installed, two-piece conduit fittings and Glenair 's Series 75 metal , Sealing-Truly the FIRST and Last Conduit System You'll Ever Need PRODUCT FACTS Broad Spectrum RFI/EMI/EMP Shielding Interchangeability with Entraco * Reduced Radar Cross section Easy Installation and Repair


Original
PDF
2014 - glenair fittings and entraco conduit

Abstract: Glenair entraco RG-233 RG233 SHIPBOARD CONDUIT R/SHIPBOARD CONDUIT
Text: Conduit Systems M24758 Flexible Waterproof EMI/EMP Conduit and End Fittings General , to shipboard warning systems and naval avionics. Glenair uniquely offers three types of conduit , complete range of conduit , tubing and fittings have been tested and approved to all applicable Mil-Spec , , TEMPEST and lightning strike. Glenair 's MIL-C-24758 conduit systems also provide: • Crush , complete range of fittings , transitions, adapters, shielding, overbraiding, and jacketing can satisfy the


Original
PDF M24758 MIL-C-24758 glenair fittings and entraco conduit Glenair entraco RG-233 RG233 SHIPBOARD CONDUIT R/SHIPBOARD CONDUIT
2013 - Conduit Component Selection Guide

Abstract: No abstract text available
Text: of MILPRF-24758A(SH) conduit and fittings . Per current U.S. Navy policy, only MIL-PRF , parts together: (1) Specify user installable components (bulk lengths of conduit , fittings and , than regular (MIL-C-915 and MIL-C-24640) cables and require larger diameter conduit and fittings , so , installation are available from Glenair . Please see page 55 for tool order information. All conduit fittings , MIL-PRF 24758A Glenair MIL-PRF-24758A Conduit Component Selection Guide A T his


Original
PDF 4758A MIL-PRF-24758A MILPRF-24758A MIL-C-24758 M24758-2, M24758-9 M24758-25) M24758-24 MIL-PRF-24758-25 Conduit Component Selection Guide
2010 - MIL-C-24640

Abstract: MIL-C-24643 MIL-D-38999 MIL-C-915 M24758A tube conduit MS312x ms3400 MS347X MIL-PRF-24785-25
Text: of MILPRF-24758A(SH) conduit and fittings . Per current U.S. Navy policy, only MIL-PRF , parts together: (1) Specify user installable components (bulk lengths of conduit , fittings and , than regular (MIL-C-915 and MIL-C-24640) cables and require larger diameter conduit and fittings , so , bulk conduit is supplied with a brass metal core, phosphorus bronze metal overbraiding and Glenair , routing requirements of your system. NOTE 1: All conduit fittings and adapters feature a combination of


Original
PDF 4758A MIL-PRF-24758A MILPRF-24758A MIL-C-24758 M24758-2, M24758-9 M24758-25) M24758-24 MIL-PRF-24785-25 MIL-C-24640 MIL-C-24643 MIL-D-38999 MIL-C-915 M24758A tube conduit MS312x ms3400 MS347X
2003 - fittings

Abstract: CONDUIT
Text: environmental conduit systems to connector adapters and other fittings must be accomplished so as to eliminate entry points for electromagnetic interference and environmental damage. Conduit fittings must also , Metal-Core Conduit Fittings are precision machined to exacting specifications, and are in wide use in many , Series 75 Metal-Core Conduit User-Installable Fittings for Series 75 Flexible Metal-Core Conduit PRODUCT FEATURES ! Conduit Fittings for Every Interconnect Application


Original
PDF
2012 - Backshells, Adapters and Transitions

Abstract: No abstract text available
Text: Conduit Introduction D o-it-yourself conduit , conduit-to-connector backshells and other fittings , unique and versatile “Hat Trick” conduit system fittings provide three key functions—conduit a n , /RFI conduit backshells, fittings and adapters are ideally suited for conventional conduit wire , installable fittings are designed for use with shielded conduit and feature easy-to-assemble ground ring , shield termination. See Section B, part numbers 712-839, 712-852, 713-356, and 713-376. © 2012 Glenair


Original
PDF M24758 Backshells, Adapters and Transitions
2008 - Drawing a Bead on Wire Protection Products

Abstract: October 2008 QwikConnect October 2008 boston insulated wire
Text: terminated bulk conduit , adapters and fittings , Glenair BlueJacket is “Haze Gray and Underway” and more , EMI in shielded applications. ■■High-performance jacketing for conduit and cables: Glenair , , whether with factory- or fieldinstallable fittings . Conduit is also ideal for prototyping and mock-ups , performance of electric vehicles. Glenair power connectors, cables and conduit are deployed in high-voltage , configurations, customized designs and wired conduit assemblies. Choose fittings in standard aluminum, brass


Original
PDF
2012 - Introduction and Quick Selection Guide

Abstract: MIL-C-13909
Text: Series 75 Metal-Core Conduit Series 75 Flexible Metal-Core Conduit System Introduction and , applications. Metalcore conduit is the material of choice for TEMPEST secure communications and intensive EMI , IAW MIL-C-13909/A-A-52240, MIL-PRF-24758A and MIL-DTL-28840. Series 75 Do-It-Yourself Fittings are , family of backshells and fittings , plus heavy-duty environmental metal and weight-saving hybrid composite , fittings . Part No. Description Page No. Flexible Metal-Core Conduit Configurations 750-190


Original
PDF MIL-C-13909/A-A-52240, MIL712-845 MIL-C-24758 Introduction and Quick Selection Guide MIL-C-13909
2003 - 8896

Abstract: Glenair BRAID
Text: Resistance and Conduit Pull Force Crush resistance values are expressed as a "percent crush" with a force , factory installed fittings .) Bulk Conduit Length Tolerances The following tolerances apply to the , FITTINGS , ADAPTERS, AND TRANSITIONS * Inner Core: Brass Stainless Steel Nickel/Iron Aluminum , . Consult the factory for other specific end fittings or adapters you may require. Conduit Adapter Installation Torques The accompanying table lists suggested torque values for tightening conduit fittings to


Original
PDF MIL-C-38999, 8896 Glenair BRAID
2009 - Selection Guide

Abstract: Convoluted ETFE material TG70
Text: planning for installation of Glenair polymer plastic and composite convoluted tubing and fittings , combinations of conduit fittings and adapters that allow the user to efficiently terminated the tubing and , Convoluted Tubing A B Introduction to Conduit Interconnect Technologies and Packaging , mechanical requirements of the application. (3) Select the transition fittings and connector adapters that , : Select Tubing Size Conduit size is identified by its inside diameter (ID) expressed in inches and


Original
PDF
2003 - glenair assembly procedures

Abstract: adapter, conduit D-12 Convoluted CONDUIT
Text: Fittings CONDUIT Fitting/ Conduit Assembly X CONN.REF. COUPLING NUT FITTING BODY © 2003 Glenair , length in Step 1. 3. Disassemble fitting from connector. Prepare conduit and assemble to adapters per , internet at www.glenair.com. 712-127 Series Fittings CONDUIT CORE Fitting/ Conduit Assembly SHIELD , pre-assembly preparation step 2 using conduit shears or an equivalent. Pull shield back and trim conduit , foreign matter and remove. 2. Slide compression nut onto conduit . 3. Flair shield approximately .06


Original
PDF
2012 - Interface Standards and Connector Designators

Abstract: HE302
Text: Conduit Introduction Conduit Backshells, Fittings and Adapters Interface Standards and Connector Designators Conduit Adapter Interface Standards A Desig. A Spec. MIL-C-5015 MIL-C , Conduit Introduction Conduit Backshells, Fittings and Adapters Interface Standards and Connector , Introduction A Conduit Backshells, Fittings and Adapters Interface Standards and Connector Designators , : sales@glenair.com Conduit Introduction Conduit Backshells, Fittings and Adapters Interface Standards and


Original
PDF MIL-C-5015 MIL-C-26482 MIL-C-81703 MIL-C-83723 40M39569 NFC93422 MS3400 HE302 MIL-C-22992 Interface Standards and Connector Designators HE302
2012 - M 52440 ASP

Abstract: No abstract text available
Text: unwired) conduit assemblies made from both Mil-qualified and Glenair commercial-off-the-shelf components , . • Conduit can also be cut to length on-site and fitted with Glenair user-installable adapters , CONNECTOR PLUG CONDUIT ASSY. DESCRIPTION THIS COPYRIGHTED DOCUMENT IS THE PROPERTY OF GLENAIR , INC. AND , connector backshell shown. These heavy duty EMI/RFI conduit backshells, fittings and adapters are ideally , unique and versatile “Hat Trick” conduit system features cleverly designed fittings that provide


Original
PDF
2012 - Factory Terminated Conduit Assemblies

Abstract: No abstract text available
Text: unwired) conduit assemblies made from both Mil-qualified and Glenair commercial-off-the-shelf components , and convenience. • Conduit can also be cut to length on-site and fitted with Glenair , 12  Glenair supplies and ships wired, terminated, and tested conduit assemblies worldwide. We , Conduit Material Choices, Material Properties, and Military Specifications Glenair Material Code , installed fittings .) Conduit Resistance and (O.D.) Conduit Pull Force Dash No. Pull Force Pounds


Original
PDF
2012 - Style 1 and Style 2 Conduit Fittings

Abstract: standard minimum lengths
Text: Conduit Introduction Standard Minimum Lengths Style 1 and Style 2 Conduit Fittings Standard , following chart defines the standard minimum lengths for straight conduit fittings , 713*S100 through 713 , the connector for the shell size and conduit dash number combinations listed. These lengths also , 48 64 Not Recommended Style 1/ Style 2 Conduit Fittings To provide an optimized termination between all series of conduit and the connector it is necessary to select either style 1 or style 2


Original
PDF
2003 - catalog 74

Abstract: Convoluted fittings
Text: Assemblies- The Perfect Solution for Prototype Applications and On-Site Assembly Glenair Series 74 Helical Convoluted Tubing User-Installable Fittings , Adapters and Transistions Threaded, user-installable fittings provide complete convenience for prototype applications and field assembly Common user-installable fittings for the Series 74 Tubing are presented in this section. Glenair 's series 74 User-Installable Fittings permit you to accomodate last-minute engineering changes, and to quickly assemble conduit


Original
PDF
2013 - M28840/17

Abstract: glenair 490
Text: with lightweight soldered fittings , or field terminated bulk conduit , adapters and fittings , Glenair , -24578A(SH) conduit , fittings and adapters. But for repair of existing systems, Glenair still manufactures , -24758 Conduit Systems and Fittings . See www.glenair.com. MIL-PRF 24758A “BlueJacket” Shipboard , Shielding Practices Handbook Glenair Qualified GR 2000 and RP2000 Series Fittings MasterSeal , users have simple expectations, such as conduit fittings that don’t leak or corrode and will last


Original
PDF MIL-PRF-24758A* F-24758A 271310Z MIL-24758A M28840/17 glenair 490
2002 - 445 Glenair

Abstract: uef 160 zn 413
Text: Conduit Systems 712-460 FIRST Swivel Adapter for Glenair Conduit Fittings Mates with Series , availability. 2. Dimensions of "B" and "F2" Hex Flats may vary based on "A" Thread and Conduit size ordered , FAX 818-500-9912 90 Conduit Systems 712-460 FIRST Swivel Adapter for Glenair Conduit Fittings Mates with Series 75 Metal-Core Conduit (750-145 & 750-147) TABLE I Dash A Thread Number , Bulkhead Feed-Thru Adapters and Other Glenair Adapters and Transitions Metric Dimensions (mm) are


Original
PDF 500-Hour 445 Glenair uef 160 zn 413
2011 - Not Available

Abstract: No abstract text available
Text: components and assemble your own conduit system. Did you know that Glenair can pre-assemble Guardian conduit systems for you? Glenair engineers can assemble point-to-point and multi-branch Guardian systems with , protection against contamination and moisture. Step 1 Select conduit /jacket type (see pages 6-7 for , for feed-thru and junction box applications. Select appropriate end fittings and adapters from the , multi-legged assemblies, select appropriate transition fittings from pgs. 26-37 ©2011 Glenair , Inc


Original
PDF
2013 - SHIPBOARD CONDUIT

Abstract: No abstract text available
Text: conduit , adapters and fittings , Glenair BlueJacket is “Haze Gray and Underway” and more than ready , Haze Gray and Underway! Introducing the Glenair MIL-PRF-24758A “BlueJacket” Conduit System M ost topside shipboard conduit users have simple expectations, such as conduit fittings that donâ , chemicals and fluids. Glenair’s U.S. Navy qualified MILPRF-24758A conduit system delivers on these expectations–and a whole lot more. Our shielded brass conduit meets all EMI shielding and surface transfer


Original
PDF MIL-PRF-24758A MILPRF-24758A M24758A SHIPBOARD CONDUIT
2014 - Metal and Polymer Core Conduit Systems

Abstract: No abstract text available
Text: SERIES 72, 74, AND 75 Metal and Polymer Core Conduit Product Families Metal and Polymer Core Conduit Systems The flexible, lightweight alternative to standard jacketed cables Series 72 Annular Polymer Core Conduit Systems Series 74 Helical Polymer Core Conduit Systems Series 75 Metal-Core , metal-core and polymercore conduit systems provide superior wire protection, electromagnetic compatibility , turnkey factory-terminated systems or convenient user-installable fittings and materials. © 2014


Original
PDF MIL-PRF-24758/Special-Purpose Metal and Polymer Core Conduit Systems
2006 - Radial sma OPTICAL FIBER

Abstract: heat shrinkable feed-throughs optical fiber free book Aircraft Fuel Fittings 12 strand multimode fiber optic cable spark absorber d38999 flammability zirconia convert linear Fiber Optic Center media converter optical fibre
Text: light-weight composite junction box, as well as the conduit , fittings , fiber optic connectors and termini , -29504 qualified termini, Glenair extruded fiber optic cable, as well as feedthrough fittings and adapters are , use in fiber optic assemblies. Likewise, accessory elbows, conduit transitions, and other fittings , most important, conduit fittings and transitions can more easily be opened for repair or to expand , fittings , or in-line and box-mounted fiber optic connectors. Glenair is uniquely positioned to provide


Original
PDF
2012 - Why Choose Conduit Instead of a Standard Cable Assembly?

Abstract: why choose conduit
Text: metal-core conduit , and machined, die-cast and injection molded backshells, adapters and fittings . In addition, we offer turnkey (wired and un-wired) conduit assemblies made from both Mil-qualified and , crush resistance and high-levels of EMI shielding. Connector-toconduit backshells, transition fittings and special adapters are available in factory assembled and user installable styles. Conduit offers , protection from heat, chemicals, and fluids. Glenair is unique in the industry because we produce all our


Original
PDF
Supplyframe Tracking Pixel