gb14048.5

Abstract: GB14048. 3 GB14048 UL File No. E41515 CSA C22.2 No. 14 lm 7803 EN418 emergency switch color code pushbutton emergency stop 2003010303070678 gb14048.3
Text: .14 E41515 TÜV Product Service EN60947-5-1 Inquire CQC (CCC) GB14048.5 2003010303070678 , , CSA C22.2 No.14, CCC( GB14048.5 ) Models with Separate Construction Rated voltage 125 VAC 250 VAC , Lighted SPST-NC A165E-R-24D-01 DPST-NC A165E-R-24D-02 Lamps Rated voltage Standard 5 VDC 12 VDC Bright 24 VDC 5 VDC 12 VDC 24 VDC LED color Red A16-5DR A16 , Switches Models with Separate Construction LED Ratings (only for Models with LEDs) 24 VDC± 5


Original
PDF A165E EN418. A165E-U) A165E-LS A165E-S-03U AA-235 gb14048.5 GB14048. 3 GB14048 UL File No. E41515 CSA C22.2 No. 14 lm 7803 EN418 emergency switch color code pushbutton emergency stop 2003010303070678 gb14048.3
gb14048.5

Abstract: GB14048. 3 GB14048 D4BS-85FS D4BS-2AFS D4BS55FS EN 60947-5-1 OMRON D4BS-35FS EN60947-5-1 gb14048.4
Text: TÜV (EN 60947-5-1), CCC ( GB14048.5 ) Item Utilization category 2A Rated operating voltage (Ue , 508 E76675 CSA CSA C22.2 No. 14 LR45746 CQC (CCC) GB14048.5 2003010305073833 , -conduit D4BS- 5 @@S D4BS-6@@S D4BS-7@@S 15 31.5 43 31.4 17 41 16 7 30±0.2 66.4 50.9 51 28.5 57 63 Four, M3. 5 head clamping screws 34.5 Six, 5.3 dia. mounting holes Four, M3. 5 x 10 cover clamping screws Two caps Cover 23 mm min. 19.61 N min. 20 mm min. Model


Original
PDF EN60947-5-1) D4BS-35FS D4BS-45FS D4BS-55FS D4BS-65FS 14NPT D4BS-75FS D4BS-25FS D4BS-15FS gb14048.5 GB14048. 3 GB14048 D4BS-85FS D4BS-2AFS D4BS55FS EN 60947-5-1 OMRON D4BS-35FS EN60947-5-1 gb14048.4
gb14048.5

Abstract: lm 7803 GB14048 GB14048. 3 a165e-02 A165E-02L EN 60947-5-1 OMRON A165E-LS-24D-01 UL File No. E41515 CSA C22.2 No. 14
Text: 508, CSA C22.2 No.14 EN 60947-5-1, EN 60947-5-5 GB14048.5 File No. E41515 Consult your representative , ( GB14048.5 ) Models with Separate Construction Rated Voltage 125 VAC 250 VAC 30 VDC Resistive Load 5A 3A 3A , mark. Note: Minimum applicable load: 5 VDC, 150 mA Note: Minimum applicable load: 5 VDC, 1 mA , Voltage 24 VAC/VDC Rated Current 8 mA Operation Voltage 24 VAC/DC ± 5 % TÜV (EN 60947-5-1) Models with , ± 5 % operation voltage, 24 VAC/VDC rated voltage Note: Models with separate construction (SPST-NC and


Original
PDF A165E EN418. A165E-U) GB14048 E41515 2003010arance A165E-R-24D-01 A165E-R-24D-02 A16Z-5070 gb14048.5 lm 7803 GB14048. 3 a165e-02 A165E-02L EN 60947-5-1 OMRON A165E-LS-24D-01 UL File No. E41515 CSA C22.2 No. 14
gb14048.5

Abstract: No abstract text available
Text: Approx. 75 g Max. 0.5 Nm acc. to IEC 60947 EN 60947-5-1 UL, CSA CCC ( GB14048.5 ) L.V. Directive 2006 , • Measures its own power supply • Power supply range: 208 to 480 VAC (±15%) • Output: 5 A , loads AC 15 DC 13 Mechanical life Electrical life SPDT relay, N.E. 250 VAC µ 5 A @ 250 VAC 5 A @ 24 VDC 2.5 A @ 250 VAC 2.5 A @ 24 VDC ≥ 30 x 106 operations ≥ 105 operations (at 5 A


Original
PDF DPA51 gb14048.5
2012 - gb14048.5

Abstract: 4116n D4B-4171N D4B-4A15N D4B-4117N D4B-4A16N SWITCHES GB14048 EN60947-5-1
Text: ) UL CSA CQC (CCC) UL508 C22.2 No. 14 GB14048.5 E76675 LR45746 2003010305077612 J9851083 TÜV , ) UL508 C22.2 No. 14 GB14048.5 E76675 LR45746 2003010305077612 * Adjustable roller lever, adjustable , TÜV (EN60947-5-1), CCC ( GB14048.5 ) Item Utilization category AC-15 2A 400 V Rated operating current , . Conduit size 2: G1/2 (PF1/2) (1-conduit) 4: M20 (1 conduit) 2. Built-in Switch 1: 1NC/1NO (snap-action) 5 , ) Inductive load NO 5 3 1.5 6 6 4 0.2 0.1 NC 2.5 1.5 0.8 Motor load NO The above values are continuous


Original
PDF
gb14048.5

Abstract: D4BL-2CRB EN 60947-5-1 OMRON
Text: . 14 GB14048.5 File No. R9451050 E76675 LR45746 2003010305073836 Certified Standard Ratings TÜV (EN 60947-5-1), CCC ( GB14048.5 ) Item Utilization category Rated operating current (Ie) Rated operating voltage , ) Switches D4BL- Red (116.5) Four, M3. 5 head clamping screws 10 15 7 Lock protection cap Four, 5.3 , before being locked Total Travel 6.8 Conduit opening D4BL-2GRD-AT Four, M3. 5 head clamping , b 2 K1 5 K2 K1 b K2 K4 Off-Delay Timer JP 1 2 3 4 5 6 6 PE T21 T23 T22 A B


Original
PDF
EN60947-5-1

Abstract: gb14048.5 GB14048. 3 EN60947 GB14048 EN60947-51 EN-60947-5-1 EN50013 D4BS-35FS D4BS-2AFS
Text: LR45746 BIA GS-ET-15 9303323 SUVA SUVA E6187.d CQC (CCC) GB14048.5 2003010305073833 s Approved Standard Ratings TÜV (EN60947-5-1), CCC ( GB14048.5 ) Utilization category AC , 3 1 1. Conduit 1: PG13. 5 (1 conduit) 2: G1/2 (1 conduit) 3: 1/2-14NPT (1 conduit) 5 : PG13. 5 , Type 1: Horizontal mounting 5 : 1NC/1NO (slow-action) 2: Vertical mounting 6: 1NC/NO (slow-action , separately.) Type 1-conduit Mounting direction 1NC/1NO (Slow-action) 2NC (Slow-action) Pg13. 5


Original
PDF EN60947-5-l AA-40 EN60947-5-1 gb14048.5 GB14048. 3 EN60947 GB14048 EN60947-51 EN-60947-5-1 EN50013 D4BS-35FS D4BS-2AFS
EN60947-5-1

Abstract: GB14048 AA-76 gb14048.5 AA78 g1224 2CRG D4BL-1CRA-A GS-ET19 EN1088 aa77
Text: ) GB14048.5 2003010305073836 Note: Ask your OMRON representative for information on approved models , -5-1), CCC ( GB14048.5 ) Item Standard model Indicator model AC-15 AC-15 Rated operating , Structure s Model Number Legend Switch D4BL - 1 2 3 4 5 1. Conduit Size (2-conduit) 1: PG13. 5 2: G1/2 3: 1/2-14NPT 2. Built-in Switch (with Safety Switch and Lock Monitor Switch Contacts , release B: Mechanical lock/110-VAC solenoid release G: 24-VDC Solenoid lock/Mechanical release 5


Original
PDF AA-83 EN60947-5-1 GB14048 AA-76 gb14048.5 AA78 g1224 2CRG D4BL-1CRA-A GS-ET19 EN1088 aa77
vctf cable

Abstract: D4C-4332 D4C-1750 D4C-4233 D4C-1201 D4C-1231
Text: , 3 UL UL508 CSA CSA C22.2 No.14 E76675 LR45746 *2 *2 CCC(CQC) GB14048.5 , (EN60947-5-1),CCC( GB14048.5 ) Degree of protection Durability Mechanical *3 *1 Electrical *2 Model , rubber cap; cable entrance sealed via encapsulating material. Cable lengths of 3 and 5 m available on , ) D4C-@@@-P (1)(2)(3) (4) (1) Rated Current (1) Rated Current (1) Rated Current 1: 5 A at 250 VAC, 4 A at 30 VDC 2: 5 A at 125 VAC (with LED indicator) 3: 4 A 30 VDC (with LED indicator) 4: 0.1 A


Original
PDF 002-M1J@ XS2H-D421 vctf cable D4C-4332 D4C-1750 D4C-4233 D4C-1201 D4C-1231
gb14048.5

Abstract: GB14048 omron switch D4Ns D4NS-4BF EN60947-5-1 G1 5C 22 330 GB14048. 3 EN1088 GS-ET-15 DC-13
Text: ( GB14048.5 ) Item TÜV Product Service Standard EN60947-5-1 (approved direct opening , note.) UL508, CSA C22.2 No.14 E76675 CQC (CCC) GB14048.5 2003010305077 330 Note: 1 , /Connector size 1: Pg13. 5 (1-conduit) 2: G1/2 (1-conduit) 3: 1/2-14NPT (1-conduit) 4: M20 (1-conduit) 5 : Pg13. 5 (2-conduit) 6: G1/2 (2-conduit) 7: 1/2-14NPT compatible (2-conduit model with M20 conduit size , . Operation Key Type 1: Horizontal mounting 2: Vertical mounting 3: Adjustable mounting (Horizontal) 5


Original
PDF M12-connector AA-17 gb14048.5 GB14048 omron switch D4Ns D4NS-4BF EN60947-5-1 G1 5C 22 330 GB14048. 3 EN1088 GS-ET-15 DC-13
vctf cable

Abstract: vctf 0.75 wire cable D4C-1233 D4C-1201 D4C-1402 D4C-1231 D4C-1424 D4C-4202 D4C-4332 D4C-1520
Text: , 3 UL UL508 CSA CSA C22.2 No.14 E76675 LR45746 *2 *2 CCC(CQC) GB14048.5 , (EN60947-5-1),CCC( GB14048.5 ) Degree of protection Durability Mechanical *3 *1 Electrical *2 Model , rubber cap; cable entrance sealed via encapsulating material. Cable lengths of 3 and 5 m available on , ) D4C-@@@-P (1)(2)(3) (4) (1) Rated Current (1) Rated Current (1) Rated Current 1: 5 A at 250 VAC, 4 A at 30 VDC 2: 5 A at 125 VAC (with LED indicator) 3: 4 A 30 VDC (with LED indicator) 4: 0.1 A


Original
PDF
gb14048.5

Abstract: HL5050 GB14048 GB14048. 3 HL-5030 HL-1HPA500 vctf 0.75 HL-5500 vct 600v cable SWITCHES GB14048
Text: -1HPA500 (HL5 0027C) - Specifications Approved Standards Agency CCC (CQC) Standard GB14048.5 File , . Approved Standard Ratings CCC ( GB14048.5 ) Applicable category and ratings AC-15 3 A/250 VAC General , Structure Model Number Legend HL- 5 @@ 1 2 1. Actuators 000: Roller lever 030: Adjustable roller lever , -5030 HL-5050 HL-5100 HL-5200 HL-5300 General-purpose Limit Switch HL-5000 K- 5 Limit , following Electrical Durability. 5 mm/s to 0.5 m/s Mechanical: 120 operations/min Electrical: 30 operations


Original
PDF HL-5000 C004-E2-11 gb14048.5 HL5050 GB14048 GB14048. 3 HL-5030 HL-1HPA500 vctf 0.75 HL-5500 vct 600v cable SWITCHES GB14048
D4NS-4BF

Abstract: D4ns-3bf GI CONDUIT D4NS-1AF D4Ns D4NS-4AF B0306 E76675 D4NS-9AF EN60947-5-1
Text: ) A300 CCC (China Compulsory Certification) Mark Agency CQC Standard GB14048.5 250 V File , Key D4NS- D4DS-K 1 2 3 1. Conduit/Connector size 1: Pg13. 5 (1-conduit) 2: G1/2 (1-conduit) 3: 1/2-14NPT (1-conduit), North America 4: M20 (1-conduit) 5 : Pg13. 5 (2-conduit) 6: G1/2 (2 , . Operation Key Type 1: Horizontal mounting 2: Vertical mounting 3: Adjustable mounting (Horizontal) 5 , configuration Slow-action 1NC/1NO Conduit opening/Connector Pg13. 5 Model D4NS-1AF G1/2 D4NS


Original
PDF M12-connector 1/2-14NPT DC-13 IEC269 EN50047 EN1088 UL508, GB14048 D4NS-4BF D4ns-3bf GI CONDUIT D4NS-1AF D4Ns D4NS-4AF B0306 E76675 D4NS-9AF EN60947-5-1
gb14048.5

Abstract: E76675 ZC-N2255 EN60947-5-1 GB14048 IEC269 IEC335 IEC60529
Text: Standard No.: GB14048.5 File number: 2003010303077620 2006/95/EC Side mounting Operating , Ambient humidity Rated voltage: 125 VAC, Inductive load: 10 A (NC) 10 A (NO), Motor load: 5 A (NC) 2.5 , : 6 A (NC) 6 A (NO), Motor load: 5 A (NC) 2.5 A (NO) Rated voltage: 14 VDC, Inductive load: 6 A (NC) 6 A (NO), Motor load: 5 A (NC) 2.5 A (NO) Rated voltage: 30 VDC, Inductive load: 5 A (NC) 5 A (NO), Motor load: 5 A (NC) 2.5 A (NO) Rated voltage: 125 VDC, Inductive load: 0.05 A (NC) 0.05 A (NO), Motor


Original
PDF ZC-N2255 gb14048.5 E76675 ZC-N2255 EN60947-5-1 GB14048 IEC269 IEC335 IEC60529
NEMA250

Abstract: E76675 EN60947-5-1 GB14048 IEC269 IEC60529
Text: : LR45746 Standard No.: EN60947-5-1 File number: J50022353 Standard No.: GB14048.5 File number , voltage: 125 VAC, Inductive load: 10 A (NC) 10 A (NO), Motor load: 5 A (NC) 2.5 A (NO) Rated voltage , Min. (No load) (Temperature, Humidityconditions: 5 CEL to 35 CEL, 40 %RH to 70 % RH) 750,000 operations Min. (Resistive load 10 A at 125 VAC) (Temperature, Humidityconditions: 5 CEL to 35 CEL, 40 %RH


Original
PDF UL508 E76675 LR45746 EN60947-5-1 J50022353 GB14048 2006/95/EC NEMA250 E76675 EN60947-5-1 IEC269 IEC60529
E76675

Abstract: GB14048 EN60947-5-1 IEC269 IEC60529 NEMA250
Text: number: J50022353 Standard No.: GB14048.5 File number: 2003010305032365 2006/95/EC Front mounting , VAC, Inductive load: 10 A (NC) 10 A (NO), Motor load: 5 A (NC) 2.5 A (NO) Rated voltage: 250 VAC , ) (Temperature, Humidityconditions: 5 CEL to 35 CEL, 40 %RH to 70 % RH) 750,000 operations Min. (Resistive load 10 A at 125 VAC) (Temperature, Humidityconditions: 5 CEL to 35 CEL, 40 %RH to 70 % RH) 3 (EN60947 , . Standard value 15 +/- 5 DEG Standard value 30 DEG Min. Standard value 12 DEG Max. Caution: All units


Original
PDF UL508 E76675 LR45746 EN60947-5-1 J50022353 GB14048 2006/95/EC E76675 EN60947-5-1 IEC269 IEC60529 NEMA250
AA204

Abstract: AA202 D4B-2A15N D4B-1116N D4B-70N J9851083 D4B-1181N AA-196 D4B-5111N AA203
Text: CQC (CCC) GB14048.5 2003010305077612 SUVA (See note.) SUVA 1-conduit: E6188/1.d 3-conduit: E6189/1.d CQC (CCC) GB14048.5 2003010305077612 Note: 1. Adjustable roller lever, adjustable , -5-1), CCC ( GB14048.5 ) Utilization category AC-15 Rated operating current (Ie) 2A Rated , 1: PG13. 5 (1-conduit) 2: G1/2 (PF1/2) (1-conduit) 3: 1/2-14NPT (1-conduit) 5 : PG13. 5 (3 , ) 3: 1NC/1NO (slow-action) gold-plated contacts 5 : 1NC/1NO (slow-action) (see note) 6: 1NC/1NO


Original
PDF WL-4A201 D4A-F00 D4B-0001N) AA-210 AA204 AA202 D4B-2A15N D4B-1116N D4B-70N J9851083 D4B-1181N AA-196 D4B-5111N AA203
Not Available

Abstract: No abstract text available
Text: 60947-5-1 UL, CSA CCC ( GB14048.5 ) L.V. Directive 2006/95/EC EMC Directive 2004/108/EC According to EN , 380 to 480 VAC (±15%) • Output: 5 A SPDT relay normally energized • For mounting on DIN-rail , life SPDT relay, N.E. 250 VAC µ 5 A @ 250 VAC 5 A @ 24 VDC 2.5 A @ 250 VAC 2.5 A @ 24 VDC ≥ 30 x 106 operations ≥ 105 operations (at 5 A, 250 V, cos ϕ = 1) ≤ 7200 operations/h


Original
PDF DPA53
Not Available

Abstract: No abstract text available
Text: . to IEC 60947 EN 60947-5-1 UL - CSA (except PPA01D, DPA01CM69), CCC ( GB14048.5 ) only DPA L.V , , L2, L3 PPA01: Terminals 5 , 6, 7 Measure their own supply 177 to 550 VAC 323 to 690 VAC 510 to , relay, N.E. 250 VAC µ 8 A @ 250 VAC 5 A @ 24 VDC 2.5 A @ 250 VAC 2.5 A @ 24 VDC 8 A @ 250 VAC 3 , ) L1, L2, L3 5 , 6, 7 208 to 480 VAC ± 15%, 45 to 65 Hz 380 to 600 VAC±15%, 45 to 65 Hz 208 to


Original
PDF DPA01, PPA01 DPA01) PPA01) DPA01
vctf cable

Abstract: D4C-1231 D4C-1250 D4C-1224 D4C-1750 D4C-4524 D4C-4233 D4C-1202 D4C-1320
Text: , 3 UL UL508 CSA CSA C22.2 No.14 E76675 LR45746 *2 *2 CCC(CQC) GB14048.5 , (EN60947-5-1),CCC( GB14048.5 ) Degree of protection Durability Mechanical *3 *1 Electrical *2 Model , rubber cap; cable entrance sealed via encapsulating material. Cable lengths of 3 and 5 m available on , ) D4C-@@@-P (1)(2)(3) (4) (1) Rated Current (1) Rated Current (1) Rated Current 1: 5 A at 250 VAC, 4 A at 30 VDC 2: 5 A at 125 VAC (with LED indicator) 3: 4 A 30 VDC (with LED indicator) 4: 0.1 A


Original
PDF
E76675

Abstract: EN60947-5-1 GB14048 IEC269 IEC335 IEC60529 ZC-Q2155 gb14048.5
Text: Standard No.: GB14048.5 File number: 2003010303077620 2006/95/EC Panel mounting, Side mounting , temperature Ambient humidity Rated voltage: 125 VAC, Inductive load: 10 A (NC) 10 A (NO), Motor load: 5 A , : 6 A (NC) 6 A (NO), Motor load: 5 A (NC) 2.5 A (NO) Rated voltage: 14 VDC, Inductive load: 6 A (NC) 6 A (NO), Motor load: 5 A (NC) 2.5 A (NO) Rated voltage: 30 VDC, Inductive load: 5 A (NC) 5 A (NO), Motor load: 5 A (NC) 2.5 A (NO) Rated voltage: 125 VDC, Inductive load: 0.05 A (NC) 0.05 A (NO), Motor


Original
PDF ZC-Q2155 E76675 EN60947-5-1 GB14048 IEC269 IEC335 IEC60529 ZC-Q2155 gb14048.5
Not Available

Abstract: No abstract text available
Text: Max. 0.5 Nm according to IEC 60947 EN 60947-5-1 UL, CSA CCC ( GB14048.5 ) L.V. Directive 2006/95/EC , • Adjustable delay function (0.1 to 30 s) • Output: 5 A SPDT relay N.E. • For mounting on , points from 2 to 5 % 1% Set points from 5 to 22% 2% Operating frequency Dielectric strength , change without notice (31.03.10) SPDT relay 250 VAC µ 5 A @ 250 VAC 5 A @ 24 VDC 2.5 A @ 250 VAC 2.5 A @ 24 VDC ≥ 30 x 106 operations ≥ 105 operations (at 5 A, 250 V, cos ϕ = 1) ≤ 7200


Original
PDF DPB71
gb14048.5

Abstract: A22E-M-12-EMS A22E-M-12-EMO A22E-M-12 A22E GB14048 A22EL-M-12A-11 A22EL-M A22E-M-11-EMO A22E-M-02-EMS
Text: Voltage Directive) 3 A at 220 VAC · CCC ( GB14048.5 ) 3 A at 240 VAC, 1.5 A at 24 VDC Ratings Contacts , direct opening mechanism) GB14048.5 EN60947-5-1 TÜV SÜD CQC (CCC) KOSHA *2 Note: Only models with , 220 VDC 380 VDC -Rated current (A) AC15 (inductive load) 10 5 3 2 1 AC12 (resistive load) 10 10 6 3 , applicable load: 10 mA at 5 VDC LED Indicators without Voltage Reduction Unit Rated voltage 6 VDC 6 VAC 12 VAC/VDC 24 VAC/VDC Rated current 60 mA 60 mA 30 mA 15 mA Operating voltage 6 VDC± 5 % 6 VAC± 5 % 12


Original
PDF 22-dia. 25-dia. /IP65 an22E A22Z-EG2 gb14048.5 A22E-M-12-EMS A22E-M-12-EMO A22E-M-12 A22E GB14048 A22EL-M-12A-11 A22EL-M A22E-M-11-EMO A22E-M-02-EMS
2011 - Not Available

Abstract: No abstract text available
Text: -5-1 GB14048.5 File No. E76675 LR45746 J50062486 2003010305072162 Approved models General-purpose models listed , 10 2 10 2 5 1.5 0.4 0.4 0.2 0.2 NC NO 15 A max. 15 A max. Inductive load (A) Inductive Motor load load NC NO NC NO 3 2.5 2 1.5 - - 5 2 5 2 1.5 1.5 0.05 0.05 0.03 0.03 Approved Standard Ratings TÜV (EN60947-5-1), CCC ( GB14048.5 ) Model SHL-@55 SHL-@55-01 SHL-@55-L SHL-@55-01L SHL-@55-01L2 SHL-@55-L3 SHL , ) 100 A (EN60947-5-1) 5 A (EN60947-5-1) Class II (grounding not required with double insulation) 1,000


Original
PDF
2008 - Not Available

Abstract: No abstract text available
Text: .2 No.14, CCC( GB14048.5 ) Models with Separate Construction Rated voltage 125 VAC 250 VAC 30 VDC 5A 3A , , CSA C22.2 No.14 EN60947-5-1, EN60947-5-5 GB14048.5 File No. E41515 Inquire 2003010303070678 mark , the contact unit. Only non-lighted models are available. None Non-lighted -24D LED 24 VAC/ VDC± 5 , SPST-NC DPST-NC Model A165E-01 A165E-02 A165E-01L A165E-02L Lamps Appearance LED color Rated voltage 5 , Construction Rated voltage 250 VAC 30 VDC 3A 3A Resistive load Note: Minimum applicable load: 5 VDC, 150 mA


Original
PDF 16-dia. A165E EN418. A165E-U)