The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
RH1011MJ8 Linear Technology IC COMPARATOR, 4000 uV OFFSET-MAX, 250 ns RESPONSE TIME, CDIP8, CERDIP-8, Comparator
RH1011MW Linear Technology IC COMPARATOR, 4000 uV OFFSET-MAX, 250 ns RESPONSE TIME, CDFP10, CERPACK-10, Comparator
RH1011MJ8#PBF Linear Technology IC COMPARATOR, 4000 uV OFFSET-MAX, 250 ns RESPONSE TIME, CDIP8, CERDIP-8, Comparator
RH1011MW#PBF Linear Technology IC COMPARATOR, 4000 uV OFFSET-MAX, 250 ns RESPONSE TIME, CDFP10, CERPACK-10, Comparator
LTC4558EUD Linear Technology IC 1-CHANNEL POWER SUPPLY SUPPORT CKT, PQCC20, 3 X 3 MM, 0.75 MM HEIGHT, PLASTIC, QFN-20, Power Management Circuit
LTC3873ETS8-5#TR Linear Technology IC SWITCHING CONTROLLER, 240 kHz SWITCHING FREQ-MAX, PDSO8, 1 MM HEIGHT, PLASTIC, TSOT-23, 8 PIN, Switching Regulator or Controller

faston 250 crimp height Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
Tyco 408-5842

Abstract: 408-9640 DC2-1982 4-0827 635X0 faston flag receptacles faston flag receptacles crimp height LR7189 Tyco faston insulated crimp
Text: Application Tooling Checking Terminal Crimp Height or Gaging Die Closure Conversion Guide For Miniature , be made to ensure crimped contact formation is consistent as shown in Figure 3. i A. Crimp Height , in ensuring optimum electrical and mechanical performance of the crimped terminal. The crimp height , the Same Crimp Height 0.13 [.005] (See Table) Max Wire Barrel Flash Section X-X , Crimp Height Flag Receptacle 0.25 [.010] (See Table) Y Max Wire Barrel Flash 0.38


Original
PDF
faston flag receptacles crimp height

Abstract: 466502-2 AMPOMATOR CLS IV PIGGYBACK 408-7424 90165-1 7432 408-9640 49710 408-8040
Text: Checking Terminal Crimp Height or Gaging Die Closure Force Gage 92­100505 Heavy Duty Miniature , crimped receptacle. The crimp height must be within the dimensions provided in Figure 3. B. Conductor , ] Max Burr Wire Barrel Crimp Height Wire Barrel Flash 0.13 [.005] Max (Refer to Table on , Piggyback Receptacles RECEPTACLE 114-2082 WIRE SIZE (AWG) APPLIED WIRE BARREL CRIMP HEIGHT , Straight 1.96-2.06 [.077-.081] 22 250 Series Flag 14 CRIMP WIDTH (Ref) 1.73-1.83


Original
PDF
466779

Abstract: 408-6976 58080-3 Tyco AMP document 408-6976 Tyco faston insulated proper hand crimping procedure B 722 P 408-9902 Tyco (AMP) document 408-6976 AMP crimper 69710-1 408-2095 UL-310
Text: FASTON Terminals CAUTION ! 114- 2123 Crimp height dimensions must not be applied directly to , Plus, and Ultra-Fast Plus Tab Series 110/125, 187, 205, and 250 Fully-Insulated FASTON Terminals , ] 250 250 Flag Terminals Figure 4 3.5. Crimp Requirements The terminal must be crimped in the , or flash-over as a result of this testing procedure. B. Crimp Height Because these terminals are fully insulated, crimp height readings cannot be measured over the insulation. Proper crimp height must


Original
PDF
114-2079

Abstract: faston flag receptacles crimp height 565435-5 2082 tyco 408-9640 114-2036 Tyco faston 686327-1 567768 faston crimp height
Text: WIDTH (REF) 1.77 [.070] 2.79 [.110] WIRE BARREL CRIMP HEIGHT +0.05 [+.002] SIZE 250 , Application Specification 114-2079 FASTON * Flag Receptacles with F" - Crimp Feature NOTE , applied crimp height . See Section 5, TOOLING. DO NOT nick, scrape, or cut the wire conductor during the , height must be within the dimension provided in Figure 3. B. Effective Crimp Length For optimum crimp , Must Both Be Visible In This 0.13 [.005] Figure 3 Table) Wire Barrel Crimp Height (See


Original
PDF
tyco crimp height chart

Abstract: 408-7424 59824-1 solder crimp height faston crimp height general maintenance for applicators 58433-3 59824-1 7432 Tyco 408-7424 59824-1 Tyco Amp
Text: Crimp Area Insulation 250 -Series Fully-Insulated PIDG FASTON Receptacle (Typ) Color-Coded Insulation 250 -Series PIDG FASTON Tab (Typ) Figure 1 2. REFERENCE MATERIAL 2.1. Revision Summary S , Corporation Rev A PIDG FASTON Tabs and Fully-Insulated Receptacles 114-13076 B. Crimp Height Procedure Because these contacts have insulated wire barrels, crimp height readings cannot be measured , Crimp Height or Gaging Die Closure Force Gage 92­100505 Hand Crimping Tool 90276­2 Miniature


Original
PDF
AMPOMATOR CLS IV

Abstract: hand tool faston flag receptacles crimp height 59824-1 Tyco Amp faston flag receptacles crimp height smema AMP UK 45 faston 110 board mount tabs Crimping micro applicator smema control AMP TYCO PLATFORM CRIMP TOOL
Text: for crimp height . For use with miniature style applicators only. (Shown with optional Crimp Quality , applicators Wide range of optional equipment such as tool-less precision crimp height adjust, batch counter , inspection. It measures the crimp height of each termination, and evaluates the quality of each crimp . If a , of terminal without the need for frequent changeovers of applicators or adjustment of crimp height , [610] Height - 18 [457] Weight - 250 lb [113 kg] Electrical - 120 to 220 VAC, 50 or 60 Hz (217600


Original
PDF
354500-1

Abstract: 408-7432 tyco crimp height chart tyco pull force chart 114-2025 46633 408-7424 LR7189 Tyco faston faston 250 crimp height
Text: WIDTH CRIMP HEIGHT INSULATION BARREL CRIMP WIDTH 6.35 [. 250 ] SERIES 4.06-5.33 [.160-.210 , Action Hand Tool 189508-1 Checking Terminal Crimp Height or Gaging Die Closure Force Gage 92-100505 , WIRE BARREL CRIMP WIDTH CRIMP HEIGHT INSUL BARREL CRIMP WIDTH 9.52 [.375] SERIES 12 10 8 , BARREL CRIMP WIDTH 2.16-3.18 [.085-.125] (2) 16 CRIMP HEIGHT 5.1-6.1 [.200-.240 , INSULATION DIAMETER STRIP LENGTH 114- 2025 CRIMP HEIGHT INSULATION BARREL CRIMP WIDTH WIRE


Original
PDF
amp 408-1559

Abstract: 818380-1 59824-1 Tyco Amp 59824-1, 408-7424 59824-1 solder crimp height 567200-2 applicator 567200-3 bellmouth 408-7278 E-66717
Text: Checking Terminal Crimp Height Gaging Die Closure Hand Crimping Tool 90246-1 Crimping Die Assemblies , Receptacle Contacts 114-1002 D. Crimp Height Because these contacts are insulated, crimp height readings cannot be measured over the insulation. Therefore, to check for proper crimp height , a piece of , solder must be as stated in Figure 3. The height of the crimped solder must be checked against the crimp , .). CAUTION Crimp height dimensions must not be applied directly to the contact. Applying crimp


OCR Scan
PDF
567200-2

Abstract: 567200-3 59824-1 Tyco Amp 565435-5 59824-1 408-7278 checking terminal crimp height 408-7424 108103 408-1559 Tyco faston
Text: Corporation Rev D PIDG FASTON Receptacle Contacts 114- 1002 CRIMP HEIGHT INSPECTION WIRE SIZE , requirements for application of PIDG FASTON receptacle contacts. The contacts are available in Series 250 , 90185-1 Checking Terminal Crimp Height Gaging Die Closure Hand Crimping Tool 90246-1 Crimping Die , Corporation 3 of 13 PIDG FASTON Receptacle Contacts 114- 1002 3.3. Crimp Requirements NOTE , . See Figure 3. D. Crimp Height Because these contacts are insulated, crimp height readings cannot


Original
PDF
408-7424

Abstract: UL-310 pull force requirements 408-7432 instructions 8082 Tyco 408-7424 faston crimp height tensile strength crimping pull test 8082 codes 567200-2 ELT 406
Text: Terminal Crimp Height Gaging Die Closure Force Gage 92-100505 For Testing FASTON Terminals Miniature , FASTON Receptacle Contacts 114- 13047 B. Crimp Height Procedure Because these contacts are fully , AWG) Mating End ( 250 - Series) Insulation Barrel Yellow Budget FASTON Receptacle Contact , [.328-.296] COLOR CODING CRIMP HEIGHT (SOLDER DIAMETER) 3.18 [.125] 18 16 14 12 10 2.92 , [. 250 ] 6 35 [ 250 ] POUNDS 8 57.8 13 89 RED NEWTONS 35.6 22 20 CRIMP PULL


Original
PDF
114-2036

Abstract: faston flag receptacles crimp height UL-310 114-2079 7432 Application# 687892-3 B 408-7432 amp cls iiiG 408-7424 6.35x0.8
Text: Application Specification 114-2036 FASTON * Straight Receptacles with F-" Crimp Feature , of 12 LOC B FASTON Straight Receptacles with F-" Crimp Feature 114-2036 2. REFERENCE , and product code 1110 are representative numbers of FASTON Straight Receptacles with "F­" Crimp , Feature FASTON Flag Receptacles with "F­" Crimp Feature FASTON Piggyback Receptacles FASTON "F­" Crimp , Crimp Height Force Gage 92­100505 Heavy Duty Miniature Quick­Change Applicators (End­Feed Type) Heavy


Original
PDF
faston flag receptacles crimp height

Abstract: DC21982 458000 408-7424 1725950-3 faston crimp height 354500-1 408-7432 Tyco faston 49710
Text: Application Specification FASTON * F-" Crimp Center-Strip Flag Receptacles NOTE i , 1 of 8 LOC B FASTON F-" Crimp Center-Strip Flag Receptacles 114-2126 2.4. Specifications , "F­" Crimp Feature FASTON AMPLIVAR* Contact Tab FASTON Flag Receptacles with Tab Lok Feature FASTON Flag Receptacles with "F­" Crimp Feature FASTON Piggyback Receptacles 2.5. Instructional Material , Checking Contact Crimp Height Force Gage 92­100505 Miniature (Mini) and Quick­Change Applicators General


Original
PDF
bellmouth standard

Abstract: 408-9640 bellmouth faston crimp height crimp quality monitor faston 250 crimp height
Text: AMPLIVAR FASTON Tab Contacts 114-2070 3.5. Crimped Contact Criteria A. Crimp Height The crimp , reverse coil reeled. They are designed to mate with a variety of FASTON Series 187 and 250 Receptacle , used. WIRE BARREL CRIMP WIRE SIZE LEAD WIRE (CMA) STRIP LENGTH HEIGHT WIDTH TYPE , contact wire barrel crimp height (contact Tyco Electronics) and crimp width (see Figure 2) must be within , ] Max. Crimp Height Measured Cutoff Tab Shall Not Exceed 0.51 [.020] Over this Flat Portion


Original
PDF
bellmouth standard

Abstract: 108-20019 114-20023 114-2002 faston crimp height gt 1081 faston 250 connector FASTON connector 140230 001602
Text: Application Specification 114-20023 Rev.G8 FASTON * Connector,. 250 " sr. Receptacle Contact , requirements for application of . 250 " sr. FASTON * Receptacle contacts (Standard and Piggy-Back versions) & , Barrel Crimp . A. Crimp Dimensions and Type: Crimp height , width and type shall be as shown in Figure 6 , ) 1.00 (17AWG) 1.50 (16AWG) 2x1.00 2.50 (14AWG) WIDTH REF. mm HEIGHT +/-0.03 mm 2.30-3.30 , INSUL. BARREL CRIMP T Y P E F WIDTH REF. mm HEIGHT REF. mm 3.30 - T Y P E


Original
PDF FTEC174 bellmouth standard 108-20019 114-20023 114-2002 faston crimp height gt 1081 faston 250 connector FASTON connector 140230 001602
AMP Faston flag connector

Abstract: faston flag receptacles with tab-lok crimp LR49710 114-2079 1725950-3 114-2078 FASTON connector faston flag receptacles crimp height 408-7424 2082 tyco
Text: 114­2070 114­2078 114­2079 114­2082 Document Title FASTON 110 Series Flag Receptacles with "F" Crimp , Application Tooling Checking Terminal Crimp Height Gaging Die Closure Miniature Quick­Change Applicator , Flash Crimp Height (See Table) NOTE: Wire barrel may roll a Section X-X maximum of 10° to , 16 14 18 16 14 SUPPORT CRIMP WIDTH HEIGHT WIDTH (REF) +0.05 [.002] (REF , 6.35 [. 250 ] Figure 3 4 of 9 Tyco Electronics Corporation Rev B FASTON Reversible


Original
PDF
Tyco 408-7424

Abstract: bellmouth standard faston flag receptacles crimp height 408-7424 Tyco faston 187-series application notes on wire drawing machine
Text: ­[ ] Checking Terminal Crimp Height or Gaging Die Closure Heavy Duty Miniature Quick­Change Applicators, (End , should appear after crimping and lists proper crimp criteria. A. Crimp Height The crimp applied to , Support .015 Rear Bellmouth Barrel Shall Grip the Wire Firmly Section X-X Crimp Height 0.13 , Application Specification 114-2152 AMPLIVAR* FASTON * Flag Receptacles NOTE i 15 SEP , application of AMPLIVAR FASTON Flag Receptacles. These right­hand receptacles are offered in designs fitting


Original
PDF
TERMINAL CRIMPING -GOLD 62040-2

Abstract: 62381 62306-2 505075-1 281006 bellmouth adjustment for applicators general maintenance for applicators 63964-1 62310 ups 6kva
Text: terminals accept .125 [3.18], .187 [4.75] and . 250 [6.35] receptacle terminals s FASTON Receptacle terminals accept .187 [4.75] and . 250 [6.35] tab terminals s FASTON Stator Receptacle accept . 250 x , Series 187 Tab Terminals AMPLIVAR FASTON Series 250 Tab Terminals 114-2144 114-2152 AMPLIVAR FASTON Series . 250 Straight Receptacle Terminals AMPLIVAR Flag FASTON Series 187 & 250 Receptacle , upon special request, contact Tyco Electronics Engineering for details. 250 Series FASTON Tabs1


Original
PDF controllngth--125 Width--54 Height--70 in-32 26-AWG 125mm25mm2] Electrical--3x208 50-60Hz; Weight--1850 TERMINAL CRIMPING -GOLD 62040-2 62381 62306-2 505075-1 281006 bellmouth adjustment for applicators general maintenance for applicators 63964-1 62310 ups 6kva
E9071003

Abstract: UL-310 696369-1 calibration of crimping tool 3-520132-2 calibration for 565435-5 LR-7189
Text: Tabs Product Facts One-piece Fully Insulated Premier Line FASTON Receptacle crimp helps prevent , "F" crimp FASTON Terminals. The "User-Friendly" design combines easy mating with rounded corners. The , Fully Insulated FASTON Receptacles A Housing Terminal Tab Slot Wire Crimp Area Insulation Guide , premier line FASTON receptacle with insulation crimp helps prevent shock and short hazards Designed for , .032 x . 250 0.81 x 6.35 .032 x . 250 0.81 x 6.35 Ultra-Fast Plus Fully Insulated FASTON Receptacles


Original
PDF
Tyco 114-2078

Abstract: faston flag receptacles crimp height tyco crimp height specification faston flag receptacles with tab-lok crimp AMPOMATOR CLS IV 114-2078 47417 TE 250 for crimping 6873 bellmouth standard
Text: for the application of FASTON Flag Receptacles with Tab­Lok Feature. This special wire barrel crimp , termination tooling for the i CAUTION applied crimp height . See Section 5, TOOLING. Do NOT nick , . Crimp Dimensions When checking crimp height , the measurement must be taken perpendicular to the flag , tooling anvil indent as shown in Figure 4. _ Spindle 90 Crimp Width Crimp Height Flag , the crimp ). i Rev M Tyco Electronics Corporation 5 of 11 FASTON Flag Receptacles


Original
PDF
565435-5

Abstract: No abstract text available
Text: - machined dies fully bottom to the precise crimp height required. The resulting termination is free , overstress nor understress the terminal barrel - machined dies fully bottom to the precise crimp height , FASTON Receptacles and Tabs B . 250 6.35 .800 20.32 Red/Black Red .205 16-14 2,050-5,180 , FASTON Terminals (Insulated and Uninsulated) PIDG FASTON Receptacles and Tabs Product Facts , pressure evenly to the center of the crimp area The TE Mated Tool/Terminal Concept TE


Original
PDF perf00 565435-5
UL-310

Abstract: E9071003 187 series faston tab 521087-1 2-520183-2 2-520080-2
Text: Tabs Product Facts One-piece Fully Insulated Premier Line FASTON Receptacle crimp helps prevent , "F" crimp FASTON Terminals. The "User-Friendly" design combines easy mating with rounded corners. The , (Continued) Ultra-Fast Fully Insulated FASTON Receptacles A Housing Terminal Tab Slot Wire Crimp Area , premier line FASTON receptacle with insulation crimp helps prevent shock and short hazards Designed for , -314919-1 Hand Tools - Extraction 250 Series-314917-1 Ultra-Pod fully insulated FASTON receptacles offer


Original
PDF
2006 - 567200-3

Abstract: applicator 567200-3 696363-1
Text: center of the crimp area n n PIDG FASTON Receptacles and Tabs The Tyco Electronics Mated Tool , fully bottom to the precise crimp height required. The resulting termination is free of contamination , machined dies fully bottom to the precise crimp height Resulting termination is free of contamination , W W W PIDG FASTON Receptacles and Tabs L L L L L . 250 Series .205 , FASTON E L Description For Tab . 250 x .032 Wire Range 22-18 16-14 Ins. Dia. Max. .134 3.40


Original
PDF
567200-2

Abstract: 59824-1 59828-1 567200-3 applicator 567200-3 90281-1 90246-1 640911-1 61060-1 MIL-T-10727
Text: understress the terminal barrel - machined dies fully bottom to the precise crimp height required. The , overstress nor understress the terminal barrel - machined dies fully bottom to the precise crimp height , 6.35 . 250 6.35 PIDG FASTON Flag Receptacles Dimensions L .866 22.00 .866 22.00 .950 , FASTON Terminals (Insulated and Uninsulated) PIDG FASTON Receptacles and Tabs Product Facts , crimping pressure, transmitting this pressure evenly to the center of the crimp area The Tyco


Original
PDF
187-series

Abstract: 187 series faston tab bellmouth standard faston crimp height 408-8039
Text: requirements for application of AMPLIVAR FASTON .187 and . 250 Series Straight Receptacle Contacts. The series , of AMPLIVAR FASTON Series . 250 Straight Receptacle Contacts. Use of these numbers will identify the , . Crimp Height and Width The crimp applied to the wire barrel portion of the contact is the most , . Care must be taken to prevent cutting, nicking, or scraping of the insulation. Crimp Height Magnet , ELECTRONICS FOR DIMENSIONS AND CRIMP CRITERIA FOR . 250 -SERIES CONTACTS) WIRE SIZE CURRENT (AMPERES


Original
PDF
09-50-1041

Abstract: No abstract text available
Text: /160 µA typical 115/230 VAC Input Protection • T3.15 A/ 250 V internal fuse in line and neutral , Molex PN 09-65-2038 Pin 1 Line Pin 2 Neutral 0.25” Faston Earth T1 Q1 0.25 (0.6) Faston , (3.6) SMD Height 0.95 (24.2) Output Connector J2 Molex PN 09-65-2048 1 +V1 2 +V1 3 RTN 4 , with Molex Series 5194 Crimp Terminals Notes 1. All dimensions in inches (mm). Tolerance .xx =  , 0.25 (0.6) Faston Ground Tab 2.52 (64.0) Bottom View 1.40 (35.6) Notes 1. All dimensions


Original
PDF EN61000-3-2tes ECS25 30-May-14 ECS60 09-50-1041
Supplyframe Tracking Pixel