The Datasheet Archive

Top Results (6)

Part ECAD Model Manufacturer Description Datasheet Download Buy Part
SP160-SM02-T SP160-SM02-T ECAD Model Superior Sensor Technology Differential Pressure Sensor Optimized for Medical ±5K Pa to ±40K Pa - Single Tray
SP160-SM02-M SP160-SM02-M ECAD Model Superior Sensor Technology Differential Pressure Sensor Optimized for Medical ±5K Pa to ±40K Pa - Multi Tray
SP110-SM02-M SP110-SM02-M ECAD Model Superior Sensor Technology Differential Pressure Sensor Optimized for Medical ±250 Pa to ±2500 Pa - Multi Tray
SP110-SM02-T SP110-SM02-T ECAD Model Superior Sensor Technology Differential Pressure Sensor Optimized for Medical ±250 Pa to ±2500 Pa - Single Tray
SP110-SM02-C SP110-SM02-C ECAD Model Superior Sensor Technology Differential Pressure Sensor Optimized for Medical ±250 Pa to ±2500 Pa - Cut Tape
SP160-SM02-C SP160-SM02-C ECAD Model Superior Sensor Technology Differential Pressure Sensor Optimized for Medical ±5K Pa to ±40K Pa - Cut Tape

equivalent for TRIAC BT136 Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
2001 - BT136 equivalent

Abstract: equivalent for TRIAC BT136 equivalent components of triac bt136 BT136 TRIAC equivalent full automatic Washing machines circuit diagram triac diac applications circuit diagram BT136 600 equivalent full automatic Washing machines microcontroller om1654 triac power control
Text: available for triggering the triac . This is even more relevant if several triacs are controlled by one , drive current available for triac triggering is even less than the 10mA to 15mA suggested above , triggering. Figure 3 shows an example of normalised IL versus Tj for the BT136 series D. 3 IL(Tj) IL , normalised IGT versus Tj for the BT136 series D. 0 50 Tj / C 100 150 Fig. 2. BT136 series D , so low that its peak value is equivalent to IL, it will take one quarter cycle, or 5ms for 50Hz


Original
PDF 1970s. 1990s BT136 equivalent equivalent for TRIAC BT136 equivalent components of triac bt136 BT136 TRIAC equivalent full automatic Washing machines circuit diagram triac diac applications circuit diagram BT136 600 equivalent full automatic Washing machines microcontroller om1654 triac power control
1998 - triac diac applications circuit diagram

Abstract: BT136 equivalent equivalent components of triac bt136 om1654 full automatic Washing machines circuit diagram equivalent for TRIAC BT136 full automatic Washing machines microcontroller Triacs equivalent BT136 600 equivalent Precision triac control thermostat
Text: available for triggering the triac . This is even more relevant if several triacs are controlled by one , drive current available for triac triggering is even less than the 10mA to 15mA suggested above , triggering. Figure 3 shows an example of normalised IL versus Tj for the BT136 series D. 3 IL(Tj) IL , normalised IGT versus Tj for the BT136 series D. 0 50 Tj / C 100 150 Fig. 2. BT136 series D , so low that its peak value is equivalent to IL, it will take one quarter cycle, or 5ms for 50Hz


Original
PDF 1970s. 1990s triac diac applications circuit diagram BT136 equivalent equivalent components of triac bt136 om1654 full automatic Washing machines circuit diagram equivalent for TRIAC BT136 full automatic Washing machines microcontroller Triacs equivalent BT136 600 equivalent Precision triac control thermostat
1997 - Triac slow on

Abstract: BT136 application note OM1654 triac bt151 bt134 triac dimmer triac snubber calculation triac snubber BT151 triac pin diagram of diac bt136 BT151 motor speed control
Text: versus Tj for the BT136 series D. Latching current IL If the triac is triggered by a gate current at , substitution of a Hi-Com for an equivalent conventional triac will almost always be possible. Hi-Com triacs , motor and inductive loads without the need for a protective snubber. The use of a Hi-Com triac greatly , commutation capability triac for use in inductive and motor load applications. These modifications have been , specifically designed to give superior triac commutation performance in the control of motors for domestic


Original
PDF
zo405mf

Abstract: triac ZO405MF BTA16-600b application motor control SCR tyn612 BTB16-600bw application motor control BTa16-600bw application motor control BTA16-600B heating control diagram 220v dimmer light bt139 bta41-600b application BTA40-700B
Text: ) Ignitor for HID lamp (2) High voltage pulses generator (with a triac ) LIC01-195H / LIC01 , DEVICES OR SYSTEMS MUST BE EXPRESSLY AUTHORIZED. STMicroelectronics PRODUCTS ARE NOT AUTHORIZED FOR USE , STMicroelectronics. As used herein: 1.Life support devices or systems are those which (a) are intended for surgical , in accordance with instructions for use provided with the product, can be reasonably expected to , .Page 19 IGNITORS: FLC for Industrial Applications


Original
PDF I-00161 PL-00-513 SGTHYRI/0303 zo405mf triac ZO405MF BTA16-600b application motor control SCR tyn612 BTB16-600bw application motor control BTa16-600bw application motor control BTA16-600B heating control diagram 220v dimmer light bt139 bta41-600b application BTA40-700B
thyristor DTF

Abstract: BT151 motor speed control BT136 TRIAC equivalent BT136 application note BTA208-600B equivalent om1654 bt138e triac diac rectifier DC motor speed control using diac and triac TRIAC MAC 15A
Text: normalised lL versus Tj for the BT136 series D. How quickly the load current readies the triac 's lL will , to give superior triac commutation performance in the control of motors for domestic equipment and , need for a protective snubber. The use of a Hi-Com triac greatly simplifies circuit design and gives , possible to achieve a high commutation capability triac for use in inductive and motor load applications , specifically designed to give superior triac commutation performance in the control of motors for domestic


OCR Scan
PDF
2000 - DIMMER BT136 600

Abstract: TRIAC BT 136 schematic diagram of remote controlled light dimmer SCHEMATIC dimmer DIMMER BT136 light dimmer working circuit using triac ac load dimmer with microcontroller triac dimmer microcontroller with zero crossing c SCHEMATIC simple dimmer BT136 application note
Text: Ignition capability of the Z86E02 MCU requires a logic-level triac ( for example, BT 136/600 D). The gate , level. The power level is an equivalent for the firing angle. A higher power level yields a smaller , . After T1 clocks out, a timer1 interrupt is serviced. The triac ignites for approximately 100 µsec, and , ; P20 : output for triac gate .triac_gate .equ bitno0 ; P21-P27 : output idle N.C. ; Port 0 pin , the ld ; let T1 run triac T1,#ignition_time for the AN001701-Z8X0400 Application


Original
PDF AN001701-Z8X0400 DIMMER BT136 600 TRIAC BT 136 schematic diagram of remote controlled light dimmer SCHEMATIC dimmer DIMMER BT136 light dimmer working circuit using triac ac load dimmer with microcontroller triac dimmer microcontroller with zero crossing c SCHEMATIC simple dimmer BT136 application note
1998 - triac BT 408

Abstract: DIMMER BT136 600 TRIAC BT 136 SCHEMATIC dimmer triac dimmer microcontroller with zero crossing c light dimmer working circuit using triac conrad DIMMER BT136 Zilog dimmer equivalent for TRIAC BT136
Text: logic-level triac ( for example, BT 136/600 D). The gate of this triac is decoupled with a 220nF/16V capacitor , , there are two external diodes for maximum port protection. The triac is ignited in the T2+G­ and T2­G , equivalent for the firing angle. A higher power level yields a smaller firing angle, that is, a smaller T1 , interrupt is serviced. The triac ignites for approximately 100 µsec, and T1 repeats for exactly 10 msec , ; P20 : output for triac gate .triac_gate .equ bitno0 ; P21-P27 : output idle N.C. ; Port 0 pin


Original
PDF Z86E02, 512-byte Z86E02 AN001700-Z8X0299 triac BT 408 DIMMER BT136 600 TRIAC BT 136 SCHEMATIC dimmer triac dimmer microcontroller with zero crossing c light dimmer working circuit using triac conrad DIMMER BT136 Zilog dimmer equivalent for TRIAC BT136
2001 - BUT11APX equivalent

Abstract: BU4508DX equivalent 2SD1876 2Sd1651 equivalent BYS21-45 smd zener diode color band 2SD1878 data sheet 2SC5296 equivalent BT151-600R BUK98150 spice
Text: East: see Italy For all other countries apply to: Philips Semiconductors, Marketing Communications , reliable and may be changed without notice. No liability will be accepted by the publisher for any , Document order number: 9397 750 07874 For package information see inside Surface Mount Packages , hassle-free solution. As a subscriber, you receive free bi-weekly business news and technology updates for , offers enhanced immunity to loss of control and satisfies the needs of the vast majority of triac


Original
PDF BT148-600R BT148-400R BUT11APX equivalent BU4508DX equivalent 2SD1876 2Sd1651 equivalent BYS21-45 smd zener diode color band 2SD1878 data sheet 2SC5296 equivalent BT151-600R BUK98150 spice
2001 - BU4508DX equivalent

Abstract: BUT11APX equivalent S0806MH P0201MA TO92 BT136 application note diode cross reference BYW96E ct 2A05 diode BU2508Dx equivalent ST2001HI equivalent BU2508DF equivalent
Text: BT136 X - 600 E voltage (V) Note: The common ending for Thyristor parts is 'R' (RMS) GRADES , BEOGRAD, Tel. +381 11 3341 299, Fax.+381 11 3342 553 Middle East: see Italy For all other countries , be changed without notice. No liability will be accepted by the publisher for any consequence of its , order number: 9397 750 07874 For package information see inside 6535 07-03-2001 06:33 , business news and technology updates for your chosen areas, and every e-mail message contains links to


Original
PDF BT148-600R BT148-400R BU4508DX equivalent BUT11APX equivalent S0806MH P0201MA TO92 BT136 application note diode cross reference BYW96E ct 2A05 diode BU2508Dx equivalent ST2001HI equivalent BU2508DF equivalent
2011 - CFL inverter circuit schematic diagram

Abstract: diac D30 cfl circuit diagram DIAC DB3 EQUIVALENT DIMMER BT136 equivalent for TRIAC BT136 EQUIVALENT NO. OF DB3 DIAC diac DB3 application note LC filter dimmer Triac diac DB3 dimmer application note
Text: diagram of a triac wall dimmer for 120 V (RMS) mains input. Cfilter Itriac Lfilter Triac ( BT136 , representative of most dimmers for 120 V mains input applications, is used as the triac wall dimmer. When using , primary side. The expression for Plamp in Equation 3 is derived using the equivalent circuit shown in , Fig 8. Resonant tank equivalent for inductive mode heating The relationship between the power , . . . . . . . . .10 Resonant tank equivalent for inductive mode heating . . . . . . . . . . . . .


Original
PDF AN10932 UBA2014 CFL inverter circuit schematic diagram diac D30 cfl circuit diagram DIAC DB3 EQUIVALENT DIMMER BT136 equivalent for TRIAC BT136 EQUIVALENT NO. OF DB3 DIAC diac DB3 application note LC filter dimmer Triac diac DB3 dimmer application note
2010 - cfl circuit diagram

Abstract: CFL inverter circuit schematic diagram diac D30 cfl ballast TRIAC ACS 12 dimmer CFL diac DB3 application note DIAC DB3 dimmable Fluorescent BALLAST D30 DIAC
Text: dimming circuit Figure 1 shows the circuit diagram of a triac wall dimmer for 120 V (RMS) mains input. Cfilter Itriac Lfilter Triac ( BT136 ) Diac (DB3) Rvar 470 k Vin Load 120 V RMS R , current IH where an IH of 15 mA to 20 mA is sufficient for most triac dimmers. AN10932 Application , primary side. The expression for Plamp in Equation 3 is derived using the equivalent circuit shown in , Fig 8. Resonant tank equivalent for inductive mode heating The relationship between the power


Original
PDF AN10932 UBA2014 cfl circuit diagram CFL inverter circuit schematic diagram diac D30 cfl ballast TRIAC ACS 12 dimmer CFL diac DB3 application note DIAC DB3 dimmable Fluorescent BALLAST D30 DIAC
2002 - GT 32 DIAC specification sheet

Abstract: Q6016RH4 equivalent TO812NH specifications TYN604 scr TO805MH Transistor s106d1 TO805MH equivalent smd transistor E72 transistor c103m S6015L equivalent
Text: TRIAC * * For detailed information, see specific data sheet in product catalog. ©2002 Teccor , factory for more information. Features · · · · · Compak Sensitive Gate Triac · · · · , Teccor for the use of the circuits or devices described in this publication. Furthermore, no license of , AN1007 Explanation of Maximum Ratings and Characteristics for Thyristors - AN1008 Miscellaneous Design Tips and Facts - - - - - - - - - - - - - - - - - - - - - - AN1009 Thyristors for Ignition of


Original
PDF S8012D SK055N S6010L S8012R SK055R S6010LS2 S8012V SK065K S6010LS3 S8015L GT 32 DIAC specification sheet Q6016RH4 equivalent TO812NH specifications TYN604 scr TO805MH Transistor s106d1 TO805MH equivalent smd transistor E72 transistor c103m S6015L equivalent
2004 - triac mw 137 600G

Abstract: Transistor s106d1 transistor c103m TYN604 scr pin diagram Triac AC INRUSH CURRENT LIMITER opto diac TYN604 scr datasheet triac bta40-700b firing circuit alternistor "application note" UJT 2N2646
Text: Teccor for the use of the circuits or devices described in this publication. Furthermore, no license of , AN1007 Explanation of Maximum Ratings and Characteristics for Thyristors - AN1008 Miscellaneous Design Tips and Facts - - - - - - - - - - - - - - - - - - - - - - AN1009 Thyristors for Ignition of , normally two- or three-terminal devices for either unidirectional or bidirectional circuit configurations , tools ( for controlled actions such as motor speed, stapling event, battery charging) · Outdoor


Original
PDF patent6008V S8008D SK020L S6008VS2 S8008L SK025L S6008VS3 S8008R SK025N S6010D triac mw 137 600G Transistor s106d1 transistor c103m TYN604 scr pin diagram Triac AC INRUSH CURRENT LIMITER opto diac TYN604 scr datasheet triac bta40-700b firing circuit alternistor "application note" UJT 2N2646
BT136-600E equivalent

Abstract: D2499 equivalent D1878 equivalent BT139-600 equivalent C4927 d1577 d1554 C5386 c5129 e13005 equivalent
Text: "Philips Type" refers to closest Philips alternative or equivalent if available. Always consider the application and compare data specifications before recommending the suitable Philips type. Type Notes: 1 - dual device. 2 - competitor RDS(on) falls between two Philips types, hence either stated , -800B BTA216X-800B BT139X-600G BTA216X-600B BT139X-600G BTA216X-600B BTA216X-800B BTA216X-800B BT136 -600E BT136 -600D BT136 -600D BT136 -600E BT136 -600D BT136 -600D BT136 -800E BT136 -600D BT136 -600D BT137


Original
PDF 10TQ045S 11DQ03 11DQ04 11EQ03 11EQ04 11EQS 15DF4 1N3645 BT136-600E equivalent D2499 equivalent D1878 equivalent BT139-600 equivalent C4927 d1577 d1554 C5386 c5129 e13005 equivalent
2008 - Q6012LH2

Abstract: mw 137 600g shindengen cf 318 rca thyristor manual SCR TAG 665 600 triac mw 137 600G SCR Handbook, rca motorola triac mac635-8 triac tag 252 600 S106D1
Text: Alternistor Triac is specifically designed for applications required to switch highly inductive loads. The , * SENSITIVE TRIAC * * For detailed information, see specific data sheet in product catalog. ©2008 , , customized solutions for your products. Product Sampling Programs-Most of our products are available as samples for testing and verification within your circuit design. Visit Littelfuse.com or contact a Littelfuse product representative for additional information. Product Evaluation Labs and


Original
PDF EC114 EC2114v1E0807 Q6012LH2 mw 137 600g shindengen cf 318 rca thyristor manual SCR TAG 665 600 triac mw 137 600G SCR Handbook, rca motorola triac mac635-8 triac tag 252 600 S106D1
2008 - BUT11ApX equivalent

Abstract: PH4030AL philips uhp lamp driver power supply circuit diagram using ic tea1530 BT136 testing power management selection guide BU4508DX equivalent 2n7002 12w nxp BSN304 equivalent bu2508af equivalent
Text: PHP3055E For application examples please see: LFPAK for DC/DC converters on page 50 PDA Backlight Supply on page 51 Buck conversion for high-end graphics cards (VGA) on page 51 Power switching in CCFL , PSMN102-200Y PHB20NQ20T PSMN130-200D PHP20NQ20T PSMN165-200K PHD9NQ20T PHP9NQ20T For , For application examples please see: P-channel MOSFETs for `floating gate' load switching on page 48 , -100B Power Management selection guide 2008 19 High voltage bipolar transistors for lighting, self


Original
PDF
2012 - diac advantageS AND DISADVANTAGES

Abstract: No abstract text available
Text: Charge Pump (VSCP) that is intended to create the necessary hold current for the triac in the dimmer. An , (RMS) applications. Cfilter Itriac Lfilter triac ( BT136 ) diac (DB3) Rvar 470 kÎ , €). See Figure 2 for details. Vi α+ α 2 ωt 019aaa333 Fig 2. Triac with , current. The current can rise high enough within the trigger period of the triac . However, for CFLs, it , triac conduction even at deep dimming since IH is exceeded for low phase-cut angles (down to A = 130Â


Original
PDF AN10961 UBA2027X UBA2027X UBA2027X. diac advantageS AND DISADVANTAGES
2000 - triac with snubber

Abstract: RF transistor W2W TRIAC RCA Westinghouse SCR handbook BATTERY CHARGER SCR ZO 607 TRIAC 11Z13 TRIAC zo 607 MA AC 220v fan motor speed control triac bt136 220v dimmer light bt139
Text: and cathode terminal for an SCR or between gate and a main terminal MT1 for a Triac , for a short pulse , biased for an SCR. For a Triac , a bias condition between the gate and main terminal MT1. The gate dc , Conducting SCR { Triac * JEDEC is an acronym for the Joint Electron Device Engineering Councils, an , Breakover as a Function of Gate Current A triac works the same general way for both positive and negative , ) QUADRANT IV MT2(­), G(+) G(+) MT2(­) Figure 2.3. Quadrant Definitions for a Triac Gate


Original
PDF DL137/D May-2000 r14525 DL137/D triac with snubber RF transistor W2W TRIAC RCA Westinghouse SCR handbook BATTERY CHARGER SCR ZO 607 TRIAC 11Z13 TRIAC zo 607 MA AC 220v fan motor speed control triac bt136 220v dimmer light bt139
2000 - TRIAC zo 607 MA

Abstract: ZO 607 TRIAC Westinghouse SCR handbook tl-130 transformer BRX49 equivalent 800w class d circuit diagram schematics triac MAC 97 AB triac MAC 97 A6 ZO 103 TRIAC 1N5760
Text: terminal for an SCR or between gate and a main terminal MT1 for a Triac , for a short pulse duration , the gate and cathode terminals with these terminals forward biased for an SCR. For a Triac , a bias , Thyristor { Triac * JEDEC is an acronym for the Joint Electron Device Engineering Councils, an , Characteristics Illustrating Breakover as a Function of Gate Current A triac works the same general way for , and Applications. Although information in this book has been carefully checked, no responsibility for


Original
PDF DL137/D May-2000 r14525 TRIAC zo 607 MA ZO 607 TRIAC Westinghouse SCR handbook tl-130 transformer BRX49 equivalent 800w class d circuit diagram schematics triac MAC 97 AB triac MAC 97 A6 ZO 103 TRIAC 1N5760
1995 - triac drive circuit pulse transformer

Abstract: transformer winding formula triac pulse train triggering BTA08-700CW gate pulse transformer triac drive circuit triac triggering gate drive pulse transformer triac gate drive circuit triac control circuit with pulse transformer
Text: voltage. With the equivalent diagram and triac gate characteristics it is possible to determine the , the gate. For proper triac triggering the gate current rise time is very important in a circuit , APPLICATION NOTE ® TRIAC CONTROL BY PULSE TRANSFORMER Ph. RABIER Among the many ways to drive a triac the pulse transformer is one of the easiest. By applying some simple rules it can be used to design an efficient triac triggering circuit without reduction of the commutation capability


Original
PDF
2004 - transformer winding formula

Abstract: 12v transformer winding formula Triac GK Series introduction of pulse transformer BTA08-700CW gate drive pulse transformer triac drive circuit pulse transformer BZW04-376BT transformer 220V 12V 8A transformer 220V to 12V
Text: equivalent diagram and triac gate characteristics it is possible to determine the output current. This has to , For proper triac triggering the gate current rise time is very important in a circuit with very high , AN436 APPLICATION NOTE TRIAC CONTROL BY PULSE TRANSFORMER INTRODUCTION Among the many ways to drive a triac the pulse transformer is one of the easiest. By applying some simple rules it can be used to design an efficient triac triggering circuit without reduction of the commutation capability of


Original
PDF AN436 transformer winding formula 12v transformer winding formula Triac GK Series introduction of pulse transformer BTA08-700CW gate drive pulse transformer triac drive circuit pulse transformer BZW04-376BT transformer 220V 12V 8A transformer 220V to 12V
1995 - transformer winding formula

Abstract: BTA08-700CW triac pulse train triggering triac drive circuit pulse transformer BZW04-376BT TRIAC TRIGGER PULSE TRANSFORMER TRIAC EQUIVALENT triac control circuit with pulse transformer triac EQUIVALENT circuit gate drive pulse transformer
Text: voltage. With the equivalent diagram and triac gate characteristics it is possible to determine the , the gate. For proper triac triggering the gate current rise time is very important in a circuit , APPLICATION NOTE ® TRIAC CONTROL BY PULSE TRANSFORMER Ph. RABIER Among the many ways to drive a triac the pulse transformer is one of the easiest. By applying some simple rules it can be used to design an efficient triac triggering circuit without reduction of the commutation capability


Original
PDF
BT131 equivalent

Abstract: BRX49 equivalent S6015L equivalent BTA16-600B equivalent BT134 equivalent BTA12-600B equivalent X0405MF equivalent equivalent mcr22 2N5064 equivalent BT131 600 equivalent
Text: 134W-800G BT136 -600D BT136 -600E BT136 -800E BT136B-600E BT136B-800E BT 136S-600 BT 136S-600D BT , 80 60 60 60 60 60 60 58 58 58 82 82 82 82 82 82 82 82 CE Closest equivalent , . SE Exact mechanical, slight electrical differences. SM Exact electrical equivalent , slight , 60 60 64 64 64 64 64 CE Closest equivalent (slight to significant electrical and/or , – ■■■K E l 132 132 Exact electrical equivalent , slight mechanical differences. 5


OCR Scan
PDF 2N5060 2N5061 2N5062 2N5063 2N5064 2N6071 2N6071A 2N6071B 2N6072 2N6072A BT131 equivalent BRX49 equivalent S6015L equivalent BTA16-600B equivalent BT134 equivalent BTA12-600B equivalent X0405MF equivalent equivalent mcr22 2N5064 equivalent BT131 600 equivalent
2008 - thyristor scr oscillator circuit

Abstract: shockley diode DIAC EQUIVALENT circuit diac with triac ac speed control SCHEMATIC circuit scr oscillator shockley diode application DIAC EQUIVALENT scr firing METHODS Thyristor Shockley diac triac control circuit motor
Text: Although the gates are shown separately for each SCR, a Triac has a single gate and can be triggered by , .17 Gating Modes The most common quadrants for Triac gating-on are Quadrants I and III, where the gate , basic fundamentals of SCR, Triac , SIDAC, and DIAC Thyristors so the user understands how they differ , ) Reverse Biased Gate Junction N P Anode Equivalent Diode Relationship Forward Bias and , Reverse Biased Junction (-) Anode Equivalent Diode Relationship J2 N Figure AN1001


Original
PDF
nt 101 thermostat

Abstract: OM1682 triac control IC triac burst fire control ic simmerstat thermostat NT 101 philips thermistor 2322 642 ntc 6k8 refrigerator thermostat philips NTC thermistor 2322
Text: has as equivalent Figure 10 while the triac is OFF, and Figure 11 while the triac is ON. For heating , design for the OM1682 triac controller IC INTEGRATED ELECTRONIC SOLUTIONS 1BUTLER DRIVE HENDON SA , Input sensing bridge design for the OM1682 triac controller IC 10.1 10.2 10.3 10.4 10.5 10.6 2 , bridge design for the OM1682 triac controller IC AN003 1 SUMMARY This application note describes the design of input sensing circuits for the OM1682 Precision Triac Controller IC. The sensor


Original
PDF AN003 OM1682 OM1682 PAX/AN95001 nt 101 thermostat triac control IC triac burst fire control ic simmerstat thermostat NT 101 philips thermistor 2322 642 ntc 6k8 refrigerator thermostat philips NTC thermistor 2322
Supplyframe Tracking Pixel