Text: Aerovox 740 Belleville Avenue New Bedford, MA 02745-6194 TEL: 508-994-9661 FAX: 508-990-8696 E-mail: pulsepower@ aerovox.com WEB PAGE: http://w w w .aerovox.com Defibrillator Capacitors for , option Pulse Capacitors for Defibrillator Applications Aerovox defibrillator capacitors are used for , Defibrillator Capacitors for Bi-phasic and Mono-phasic Wave Forms I .25 ±.04 H ±.08 OVAL ROUND (P , CONTACT AEROVOX. Typical Ratings fo r Defibrillator Applications Mfd 54|xF 32nF 32jj.F 35fxF 49(xF


OCR Scan
PDF 232EW195D QL232EW115D QR222EW100P QR212EW105D QP212EW105N NH3G/641 defibrillator Aerovox energy discharge KD442 ql232 Aerovox aerovox electrolytic biphasic "defibrillator"
2013 - DF01209

Abstract: No abstract text available
Text: defibrillators. If your product or application requires a specialized capacitor, our expert Custom Applications , Defibrillator Capacitors Film Capacitors FOR EXTERNAL DEFIBRILLATOR APPLICATIONS RoHS , the industry leader in film capacitors for external defibrillator applications. Aerovox’s defibrillator capacitors are designed with extensive process validation and manufactured under a rigorous , Defibrillator Capacitors RoHS COMPLIANT Film capacitors for External Defibrillator Applications Aerovox


Original
PDF DF01209
2011 - ql232

Abstract: QR172YW105V Aerovox "defibrillator" defibrillator
Text: for use in hospitals, emergency rooms, first responders and public access defibrillators. If your , Defibrillator Capacitors Film Capacitors FOR EXTERNAL DEFIBRILLATOR APPLICATIONS RoHS COMPLIANT Intelligent Capacitor Solutions Defibrillator Capacitors RoHS COMPLIANT Film capacitors for External Defibrillator Applications Reliability and high level performance position Aerovox as the industry leader in medical capacitors. Aerovox's defibrillator capacitors are designed with extensive process validation to


Original
PDF DF1110 ql232 QR172YW105V Aerovox "defibrillator" defibrillator
2012 - Aerovox

Abstract: QR222EW105V QR172YW105V w048 aerovox capacitor oval Type p aerovox capacitor hp defibrillator QS222EW195N 240/"AC/TN26/15/STP/afps aerovox Capacitor
Text: for use in hospital, emergency room, first responder and public access defibrillators. If your product , Defibrillator Capacitors FILM CAPACITORS FOR EXTERNAL DEFIBRILLATOR APPLICATIONS RoHS COMPLIANT Intelligent Capacitor Solutions Defibrillator Capacitors RoHS COMPLIANT FILM CAPACITORS FOR EXTERNAL DEFIBRILLATOR APPLICATIONS Reliability and high level performance position Aerovox as the industry leader in film capacitors for external defibrillator applications. Aerovox's defibrillator capacitors are


Original
PDF DF01209 Aerovox QR222EW105V QR172YW105V w048 aerovox capacitor oval Type p aerovox capacitor hp defibrillator QS222EW195N 240/"AC/TN26/15/STP/afps aerovox Capacitor
2006 - defibrillator

Abstract: biphasic aerovox defibrillator circuits ql232 QL232EW240V QR222EW105V room for hospital QR172YW105V QR232EW195V
Text: Aerovox Corp.® Type Q Defibrillator Capacitors RoHS Compliant Defibrillator Capacitors for Bi-Phasic and Mono-Phasic Wave Forms Type Q capacitors are specifically designed to give long life and a small size for use in hospital emergency room and public access defibrillators. Type Q utilizes the latest metallized film technology with designs up to 6000 Vdc and an energy density to 1.47 J/cm3 , Round Round Round Ratings are representative of OEM defibrillator capacitors. Contact Aerovox to


Original
PDF QL232EW120V QL502EW032V QL422YW048V QL232EW195V QL602EW032V QL232EW240V QR172YW105V QR222EW105V QR252EW090V QR222EW195V defibrillator biphasic aerovox defibrillator circuits ql232 QL232EW240V QR222EW105V room for hospital QR172YW105V QR232EW195V
1996 - defibrillator circuits

Abstract: "Isolation Amplifier" ecg mosfet TRANSISTOR ECG ecg simulator circuit defibrillator power supply ECG isolation amplifier PT100 RTD signal conditioning noise problem ecg simulator circuit with transistor ecg simulator ECG Amplifier
Text: monitoring equipment from defibrillator transients and electrosurgery (ESU) interference. Process control , 2N3904s), and the isolation amp's internal insulation protect the amplifier from defibrillator and ESU , the defibrillator , which generates electrical pulses. The ESU has two modes: coagulate and cut. In , (earth) ground. During ESU and defibrillator operation, the two 2N3904 transistors clamp the INA110's , 100pA. The 330k input resistors limit the peak defibrillator input current to less than 10mA, but they


Original
PDF
2000 - ecg simulator circuit

Abstract: "Isolation Amplifier" ecg ECG isolation amplifier defibrillator circuits ecg simulator defibrillator automatic defibrillator defibrillator power supply electro surgery rf electro surgery
Text: monitoring equipment from defibrillator transients and electrosurgery (ESU) interference. Process control , 2N3904s), and the isolation amp's internal insulation protect the amplifier from defibrillator and ESU , the defibrillator , which generates electrical pulses. The ESU has two modes: coagulate and cut. In , (earth) ground. During ESU and defibrillator operation, the two 2N3904 transistors clamp the INA110's , 100pA. The 330k input resistors limit the peak defibrillator input current to less than 10mA, but they


Original
PDF
2010 - cardiac pacemaker

Abstract: defibrillator AED Defibrillator ekg op amp portable ECG ECG book pacemaker digital pacemaker holter monitor AD7766
Text: . Additionally, ECG devices need to be able to react quickly when the patient is shocked with a defibrillator. , , such as electrocardiogram (ECG/EKG) devices and automated external defibrillator (AED) devices. These , defibrillator technology. System developers strive to build devices with these factors in mind and, in many , pacemaker or ICD (implantable cardioverter defibrillator , an implanted pacemaker device with defibrillator


Original
PDF ADSP-BF50x cardiac pacemaker defibrillator AED Defibrillator ekg op amp portable ECG ECG book pacemaker digital pacemaker holter monitor AD7766
Not Available

Abstract: No abstract text available
Text: 2830 S. Fairview Street Santa Ana, CA 92704 Phone: (714) 979-8220 Fax: (714) 559-5989 DESCRIPTION: • • • • MSAFA1N100D Fast MOSFET Die for Implantable Cardio Defibrillator Applications N-Channel enhancement mode high density MOSFET die Passivation: oxynitride, 4um Frontside , specified MSAFA1N100D Fast MOSFET Die for Implantable Cardio Defibrillator Applications DYNAMIC , MOSFET Die for Implantable Cardio Defibrillator Applications MECHANICAL CHARACTERISTICS V G S v s


Original
PDF MSAFA1N100D MSAFA1N100DL, MSC1054
1999 - defibrillator

Abstract: MOSFET 1000 VOLTS soft solder die bonding MSAFA1N100D MSAFA1N100DL
Text: 2830 S. Fairview Street Santa Ana, CA 92704 Phone: (714) 979-8220 Fax: (714) 559-5989 DESCRIPTION: · · · · MSAFA1N100D Fast MOSFET Die for Implantable Cardio Defibrillator Applications N-Channel enhancement mode high density MOSFET die Passivation: oxynitride, 4um Frontside (top , MSAFA1N100D Fast MOSFET Die for Implantable Cardio Defibrillator Applications DYNAMIC CHARACTERISTICS , Defibrillator Applications MECHANICAL CHARACTERISTICS V G S v s V D S v s ID 4.9 4.7 VGS(V) 4.5


Original
PDF MSAFA1N100D MSAFA1N100DL, MSC1054 defibrillator MOSFET 1000 VOLTS soft solder die bonding MSAFA1N100D MSAFA1N100DL
AQ0800

Abstract: defibrillator OE RSG Series EN60601-1 EN 60950 "defibrillator" open frame 24v 1.25a
Text: compliant SAFETY ··Type BF, CF & Defibrillator proof variants available ··UL60601-1 and UL60950 ··IEC , Rating, defibrillator proof CF: CF Leakage Current Rating CFD: CF Leakage Current Rating, defibrillator proof Industrial Grade xx: Standard Option All combinations may not make valid part numbers


Original
PDF D-63069 AQ0800 defibrillator OE RSG Series EN60601-1 EN 60950 "defibrillator" open frame 24v 1.25a
2013 - Not Available

Abstract: No abstract text available
Text: R A D E ••Type B, BF, CF & Defibrillator proof variants available ••UL 60601-1:2003 , ••CE Marked ••CF Patient Contact ••Defibrillation Proof Defibrillator proof Type CF , Brick 2.39” (60.6) 1.54” (39.01) Converter height 0.5” (12.7) Defibrillator


Original
PDF 5-264V 47-63Hz) EN61000-3-2 EN60601-1 EN55011
2001 - defibrillator

Abstract: MSAFA1N100D MSAFA1N100DL
Text: 2830 S. Fairview Street Santa Ana, CA 92704 Phone: (714) 979-8220 Fax: (714) 559-5989 DESCRIPTION: · · · · MSAFA1N100D Fast MOSFET Die for Implantable Cardio Defibrillator Applications N-Channel enhancement mode high density MOSFET die Passivation: oxynitride, 4um Frontside (top , MOSFET Die for Implantable Cardio Defibrillator Applications DYNAMIC CHARACTERISTICS: SYMBOL , otherwise specified MSAFA1N100D Fast MOSFET Die for Implantable Cardio Defibrillator Applications


Original
PDF MSAFA1N100D MSAFA1N100DL, MSC1054 defibrillator MSAFA1N100D MSAFA1N100DL
defibrillator

Abstract: ma 2830 msc diode MSAFA1N100P3
Text: Santa Ana Division MSAFA1N100P3 MOSFET Device Features · · · · · · · Low On-State resistance Avalanche and Surge Rated High Frequency Switching Ultra low Leakage Current UIS rated Available with Lot Acceptance Testing "L" Suffix Available with "J" leads Applications 1 Amp 1000 V N-Channel enhancement mode high density · Implantable Cardio Defibrillator Testing and Screening , MSAFA1N100P3 Fast MOSFET for Implantable Cardio Defibrillator Applicaions Dynamic Electrical


Original
PDF MSAFA1N100P3 defibrillator ma 2830 msc diode MSAFA1N100P3
Not Available

Abstract: No abstract text available
Text: M M1Santa Ana,^ C A _ _ ■A p CA M ■Nbcrosemi Progress Powered ly Technology 2830 S. Fairview Street Santa Ana, CA 92704 Phone: (714) 979-8220 Fax: (714)559-5989 MSAFA1N100D Fast MOSFET Die for Implantable Cardio Defibrillator Applications DESCRIPTION: • • • â , MSAFA1N100D Fast MOSFET Die for Implantable Cardio Defibrillator Applications Progrese Powered by , Implantable Cardio Defibrillator Applications Progress Powered by Technology MECHANICALCHARACTERISTICS


OCR Scan
PDF MSAFA1N100D MSC1054
2005 - Not Available

Abstract: No abstract text available
Text: Medium Power Film Capacitors FD Design GENERAL DESCRIPTION FD series use metallized dielectric, controlled self-healing technology, high specific energy. USUAL APPLICATIONS The FD capacitors are designed for discharge applications such as Laser, electronic flash, cardiac defibrillator , etc. FD series offer a very high specific energy level, higher than 1500J per liter for cardiac defibrillator application. Operating temperature: Storage temperature: Capacitance range: Capacitance tolerance


Original
PDF 1500J FDBB6S0157K-- FDBB6P0107K-- FDBB6X0706K--
2006 - defibrillator

Abstract: FDV16Q0206K laser diode lifetime 100000
Text: Medium Power Film Capacitors FD Design GENERAL DESCRIPTION FD series use metallized dielectric, controlled self-healing technology, high specific energy. USUAL APPLICATIONS The FD capacitors are designed for discharge applications such as Laser, electronic flash, cardiac defibrillator , etc. FD series offer a very high specific energy level, higher than 1500J per liter for cardiac defibrillator application. Operating temperature: Storage temperature: Capacitance range: Capacitance tolerance


Original
PDF 1500J FDBB6S0157K-- FDBB6P0107K-- FDBB6X0706K-- defibrillator FDV16Q0206K laser diode lifetime 100000
2011 - Discharge

Abstract: "defibrillator" capacitor 1400V
Text: Medium Power Film Capacitors FD (RoHS Compliant) GENERAL DESCRIPTION FD series use metallized dielectric, controlled self-healing technology, high specific energy. USUAL APPLICATIONS The FD capacitors are designed for discharge applications such as Laser, electronic flash, cardiac defibrillator , etc. FD series offer a very high specific energy level, higher than 1500J per liter for cardiac defibrillator application. PACKAGING MATERIAL Cylindrical with thermosetting sleeve, sealed with


Original
PDF 1500J 06K-FDV16L0606K-FDV16L0406K-FDV16L0206K-- Discharge "defibrillator" capacitor 1400V
2010 - defibrillator

Abstract: laser diode lifetime 100000 "defibrillator"
Text: Medium Power Film Capacitors FD (RoHS Compliant) GENERAL DESCRIPTION FD series use metallized dielectric, controlled self-healing technology, high specific energy. USUAL APPLICATIONS The FD capacitors are designed for discharge applications such as Laser, electronic flash, cardiac defibrillator , etc. FD series offer a very high specific energy level, higher than 1500J per liter for cardiac defibrillator application. PACKAGING MATERIAL Cylindrical with thermosetting sleeve, sealed with


Original
PDF 1500J defibrillator laser diode lifetime 100000 "defibrillator"
Si8660

Abstract: defibrillator circuits Si8630 defibrillator power supply SI823 digital galvanic isolator blood pressure measurement digital circuit HCPL-3120 reliability data HV transformer 5kv ultrasound therapy block diagram
Text: VDDB VDDB Q2 RDT2 Q4 VOB VOB GNDB GNDB Figure 3: ISOdriver-Based Defibrillator Power Stage Defibrillator Application Figure 3 shows the power stage for a defibrillator where two , Equipment Otoscopes/Opthalmascopes System Examples Blood pressure, ECG, Defibrillator IV pumps


Original
PDF Si84xx Si85xx Si823x Si822x AN398 Si8660 defibrillator circuits Si8630 defibrillator power supply SI823 digital galvanic isolator blood pressure measurement digital circuit HCPL-3120 reliability data HV transformer 5kv ultrasound therapy block diagram
ZL70081

Abstract: low cost hearing aid circuit diagram circuit diagram of pill camera circuit diagram of digital hearing aid insulin pump circuit diagram cardiac pacemaker 0.18-um CMOS technology characteristics Hearing Aid Circuit Diagram circuit diagram of low cost hearing aid hearing aid chip
Text: defibrillator (ICD), neurostimulators, etc. ­ Why introduce MICS ? - Removes limitations associated with , Deep brain stimulation Stimulatory Devices ­ Pacemaker ­ Implantable Cardioverter/ Defibrillator , stimulation Defibrillator Cardiac pacemaker Heart Sensor Drug delivery/ Insulin pump Bladder


Original
PDF ZL70100: ZL70081: ZL70262: mid-1990s, ZL70081 low cost hearing aid circuit diagram circuit diagram of pill camera circuit diagram of digital hearing aid insulin pump circuit diagram cardiac pacemaker 0.18-um CMOS technology characteristics Hearing Aid Circuit Diagram circuit diagram of low cost hearing aid hearing aid chip
2014 - glucose

Abstract: No abstract text available
Text: in their use. Some ambulances may carry AEDs in addition to manual defibrillators. AEDs, as their , like defibrillators are deployed in many public places such as sports venues, schools, airports , resistor manufacturer and supplier. Automatic External Defibrillators (AEDs) Automatic external defibrillators operate on the same principle as the external defibrillators found in hospitals. They are used , external defibrillators are those where the charge is delivered via paddles placed on the chest whereas


Original
PDF
2004 - capacitor 104 1KV

Abstract: No abstract text available
Text: Medium Power Film Capacitors FD Design GENERAL DESCRIPTION FD series use metallized dielectric, controlled self-healing technology, high specific energy. USUAL APPLICATIONS The FD capacitors are designed for discharge applications such as Laser, electronic flash, cardiac defibrillator , etc. FD series offer a very high specific energy level, higher than 1500J per liter for cardiac defibrillator application. ELECTRICAL CHARACTERISTICS Operating temperature: Storage temperature: Capacitance range


Original
PDF 1500J FDBB6S0157K-FDBB6P0107K-FDBB6X0706K-- capacitor 104 1KV
2007 - heart rate monitor

Abstract: infusion pump remote heart rate monitor defibrillator airborn laptop security station Patient Monitor
Text: Patient Monitor Defibrillator Healthcare Mainframe Computer Dialysis Machine Access Point , Devices Medical Beds Defibrillator Telemetry Ultrasound Medical Imaging Systems Blood Processing


Original
PDF
defibrillator

Abstract: defibrillator circuit diagram phase shifter transformer charge controller using power grid block diagram "defibrillator" igbt capacitor charge pump Igbt high voltage low current
Text: Summer 2000 Issue Article A Schocking System Solution for Implantable Cardioverter Defibrillators Jonas Weiland New Business Development Micro Power Products High Voltage Half Bridge: a Breakthrough Defibrillator Module ICD Background Implantable Cardioverter Defibrillators (ICD) have been in common use for a number of years. The ICD applies a high voltage pulse between two electrodes , diagram of a two-phase defibrillator system and the high voltage bridge required to generate the


Original
PDF MED427 Q4-2000. defibrillator defibrillator circuit diagram phase shifter transformer charge controller using power grid block diagram "defibrillator" igbt capacitor charge pump Igbt high voltage low current