Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    Part Img DS2506 datasheet by Maxim Integrated Products

    • EPROM, 64-kbit Add-Only Memory
    • Original
    • No
    • No
    • Obsolete
    • EAR99
    • 8542.32.00.71
    • 8542.32.00.70
    • Always verify details of parts you are evaluating, as these parts are offered as suggestions for what you are looking for and are not guaranteed.

    DS2506 datasheet preview

    Datasheet Impression

    DS2506 Price & Stock

    Distributor Stock Lead Time Min Order Qty Price Buy
    DigiKey () 1
    • 1 $6.56
    • 10 $6.56
    • 100 $6.56
    • 1000 $6.56
    • 10000 $6.56
    Buy Now
    528
    • 1 -
    • 10 -
    • 100 -
    • 1000 $4.74
    • 10000 $4.74
    Buy Now
    • 1 -
    • 10 -
    • 100 -
    • 1000 -
    • 10000 -
    Buy Now

    DS2506 Frequently Asked Questions (FAQs)

    • The DS2506 can support up to 256 devices on a single 1-Wire bus, but the actual number of devices that can be connected depends on the specific application and the bus capacitance. A good rule of thumb is to limit the number of devices to 10-20 to ensure reliable operation.
    • To ensure reliable communication over long 1-Wire bus lengths, use a twisted pair cable, keep the bus capacitance low, and use a repeater or a buffer like the DS2482-100 to amplify the signal. Additionally, ensure that the bus is properly terminated and that the master device is capable of driving the bus.
    • The VPP (Programming Voltage) pin is used to program the EPROM memory of the DS2506. It is not required for normal operation and can be left unconnected if programming is not needed. However, if programming is required, VPP must be connected to a voltage source between 11.5V and 12.5V.
    • Yes, the DS2506 can operate with a 5V power supply, but the device's programming voltage (VPP) must be between 11.5V and 12.5V. If programming is not required, the device can operate with a 5V power supply, but the EPROM memory will not be accessible.
    • The DS2506 has built-in error detection and correction mechanisms, including cyclic redundancy checks (CRCs) and retry mechanisms. However, it is still important to implement error handling in the application software to handle cases where the error correction mechanisms fail. This may include retrying the data transfer, checking the integrity of the data, and taking corrective action if an error is detected.
    Supplyframe Tracking Pixel