The maximum capacitance load for the AFM45US24C2 is 10uF. Exceeding this value may affect the stability of the output voltage.
While the AFM45US24C2 has a rated operating temperature range of -40°C to +85°C, it's recommended to derate the output power by 2.5% per °C above 60°C to ensure reliable operation.
To ensure EMC, follow proper PCB layout and design guidelines, use a metal enclosure, and add EMI filters or shielding as necessary. Additionally, the AFM45US24C2 has built-in EMI filters, but external filtering may still be required depending on the application.
The recommended input fuse rating for the AFM45US24C2 is 2A slow-blow or 1A fast-acting, depending on the application and system requirements.
Yes, you can parallel multiple AFM45US24C2 modules, but ensure that each module has its own input fuse and that the output voltages are matched within 1% to prevent current imbalance.