The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
LTC1921IMS8 Linear Technology LTC1921 - Dual -48V Supply and Fuse Monitor; Package: MSOP; Pins: 8; Temperature Range: -40°C to 85°C
LTC1921CMS8#PBF Linear Technology LTC1921 - Dual -48V Supply and Fuse Monitor; Package: MSOP; Pins: 8; Temperature Range: 0°C to 70°C
LTC1921CS8#TR Linear Technology LTC1921 - Dual -48V Supply and Fuse Monitor; Package: SO; Pins: 8; Temperature Range: 0°C to 70°C
LTC1921CS8 Linear Technology LTC1921 - Dual -48V Supply and Fuse Monitor; Package: SO; Pins: 8; Temperature Range: 0°C to 70°C
LTC1921IS8#TR Linear Technology LTC1921 - Dual -48V Supply and Fuse Monitor; Package: SO; Pins: 8; Temperature Range: -40°C to 85°C
LTC1921CS8#TRPBF Linear Technology LTC1921 - Dual -48V Supply and Fuse Monitor; Package: SO; Pins: 8; Temperature Range: 0°C to 70°C

blown fuse indicator Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
blown fuse indicator

Abstract: MSC101N1M E213122 c2120* transistor Q216674 w219784 fuse 32A 10x38 690V datasheet of blown fuse indicator S218217 k2151
Text: without blown fuse indicator light Ref.number Cat. Number Q218215 Q216674 C212085 E213122 , blown fuse indicator light Ref. Number Cat. Number W219784 D232602 K215151 R226611 E232603 , - Un 690V Nb. of Poles 1+N 3+N Model without blown fuse indicator light Ref.number Cat. Number Y201317 S218217 MSC101N1M MSC103N3M Model with blown fuse indicator light Ref. Number , MSC 10 Fuse Holder MSC 10 fuse holder ­ no accessories Ith max. 32A - Un 690V for 10x38 fuses


Original
PDF MSC10, 10x38 Q218215 Q216674 C212085 E213122 M215659 E217193 F218735 MSC8/10N blown fuse indicator MSC101N1M E213122 c2120* transistor Q216674 w219784 fuse 32A 10x38 690V datasheet of blown fuse indicator S218217 k2151
2CSM200923R1801

Abstract: 2CSM204753R1801 IEC 60947-3 ac-22b 2CSM204733R1801 2CSM200983R1801 2CSM204713R1801 2CSM200883R1801 2CSM204703R1801 IEC 60947-3 AC-22B IP20 2CSM202483R1801
Text: during maintenance. Versions with blown fuse indicator allow to check whether the fuse is still working , 6 2CSC400699F0201 N 32 E 9N s: version with blown fuse indicator light E 90 , blown fuse indicator light Technical features Type Fuse Kind of current Rated frequency Rated , . Versions with blown fuse indicator allow to check whether the fuse is still working correctly or not. E , 91/32 PVs Rated current 1 1 In 2 32 2 E 92/32 PV s: version with blown fuse


Original
PDF 2CSC400696F0201 2CSM200923R1801 2CSM204753R1801 IEC 60947-3 ac-22b 2CSM204733R1801 2CSM200983R1801 2CSM204713R1801 2CSM200883R1801 2CSM204703R1801 IEC 60947-3 AC-22B IP20 2CSM202483R1801
2004 - ferraz 10x38 32 A URB

Abstract: Protistor urd IEC 60269-4 ferraz ferraz protistor Protistor url Z076934 A050URD2T13I A050URB10T13I 2A 10x38 ferraz ferraz shawmut fuse 10x38
Text: Watts loss 0.8 IN IN Tested breaking capacity 600 V without blown fuse indicator URD * 100 , trip-indicator: 20 V * higher ratings without blown fuse indicator see 10x38gRB - 690 VAC SCAC170 12/04 , fuses 10.3x38 - Without blown fuse indicator Current Rating Designation Ref. Number Catalog Number , VAC Electrical characteristics Time vs current characteristics WITHOUT BLOWN FUSE INDICATOR WITH , 60269-4 Without blown fuse indication 0.10 up to 0.80 A* With trip-indicator (1 to 30 A), a Ferraz


Original
PDF 10x38 SCAC173 ferraz 10x38 32 A URB Protistor urd IEC 60269-4 ferraz ferraz protistor Protistor url Z076934 A050URD2T13I A050URB10T13I 2A 10x38 ferraz ferraz shawmut fuse 10x38
2008 - Not Available

Abstract: No abstract text available
Text: N J 150 L D1 D G M B e With blown fuse indicator A C H N J 150 L , 630 800 1000 1250 Watts loss (W) 45 51 77 80 With blown fuse indicator Designation , General Purpose IEC Fuses General Purpose IEC Fuses NH Fuses (Plain Blades) gG Plastic body with/without French striker gG 500V Size 4 from 630 to 1250 A • BLADE-STYLE FUSES: WITH BLOWN FUSE INDICATOR or TRIP-INDICATOR • COMPLYING WITH IEC 269.1 and 2.1, NF EN 60269.1 & 2 NF C 63210 - 63211 AND


Original
PDF 1900g GPEU51
2008 - Not Available

Abstract: No abstract text available
Text: J 150 L J 150 L A C H With blown fuse indicator D2* 77 F* 14 G 2,5 , Watts loss (W) 41 49 70 75 With blown fuse indicator Designation Ref. Number aM aM aM , General Purpose IEC Fuses General Purpose IEC Fuses NH Fuses (Plain Blades) aM Plastic body with/without French striker aM 500V Size 4 from 630 to 1250 A • BLADE-STYLE FUSES: WITH BLOWN FUSE INDICATOR OR TRIP-INDICATOR • COMPLYING WITH IEC 269.1 AND 2.1, NF EN 60269.1 & 2 NF C 63210 - 63211 AND


Original
PDF 1900g GPEU59
0116 led

Abstract: T0108-0 37805 FU633 blown fuse indicator 598.26 PC16 PR30 0115
Text: with or without blown fuse indicator . 16 mm block with disconnect link bar locked on blue holder. DIN 1 - DIN 3 Color Part numbers Color Type Type Without blown fuse indicator : Grey M 10/16.SF 0115 377.24 For fusion indicator to be ordered separately : Grey M 10/16.SFL 0115 , .217" 2, 3 3 Insulating tip 4 Blown fuse indicator (2) 24-8 AWG 24-8 AWG 24-8 AWG 24-8 , T01080 001229 M 10/16.SF. Fuse holder terminal blocks for 6,35 x 32 mm 1/4 x 1 1/4 in


Original
PDF T01080 0116 led T0108-0 37805 FU633 blown fuse indicator 598.26 PC16 PR30 0115
LR21455

Abstract: 6J60A3B 6SM30A2 6CC30A1SPQ 6SC30A2-C 6SM30A3 6M30A3S CLASS J blown fuse indicator 6SM30A2I 6CC30A3SPQ
Text: Base Material: Thermoplastic POWER Without Blown Fuse Indicator Stock No. 70193202 70193203 70193204 , No. LR21455 Base Material: Thermoplastic Without Blown Fuse Indicator Stock No. 70193208 70193209 , 13.63 22.08 2-4 7.67 13.21 21.33 5-9 7.44 12.82 19.98 With Blown Fuse Indicator FUSES With Blown Fuse , . Fuse Holders Applications. Marathon Fuse Holders can be used in various applications, including control , . Copper Box Connectors are available on 30 and 60 amp fuse holders. Add Cu after the catalog number


Original
PDF E35113 UL4248-1 FSM25E FSM37E FSM50E LR21455 6J60A3B 6SM30A2 6CC30A1SPQ 6SC30A2-C 6SM30A3 6M30A3S CLASS J blown fuse indicator 6SM30A2I 6CC30A3SPQ
2008 - Not Available

Abstract: No abstract text available
Text: K A C A C H N N L L J With trip-indicator J With blown fuse indicator , /without French striker aM 500V Size 2 and 3 from 125 to 630 A • BLADE-STYLE FUSES: WITH BLOWN FUSE INDICATOR OR TRIP-INDICATOR • COMPLYING WITH IEC 269.1 AND 2.1, NF EN 60269.1 & 2 NF C 63210 - , 17 24 28 34 24 28 34 41 aM aM aM aM aM aM aM aM aM aM aM With blown fuse indicator 2 2 2 2 2 2 2 3 3 3 3 /125 /160 /200 /250 /315 /400 /500 /315 /400 /500


Original
PDF GPEU57
2008 - NH2GG50V250

Abstract: K095045 M095047 NH3GG50V630
Text: K A C A C H N N L L J J With blown fuse indicator With trip-indicator , 45 With blown fuse indicator Designation Ref. Number gG gG gG gG gG gG gG gG gG gG , General Purpose IEC Fuses General Purpose IEC Fuses NH Fuses (Plain Blades) gG Plastic body with/without French striker gG 500V Size 2 and 3 from 125 to 630 A • BLADE-STYLE FUSES: WITH BLOWN FUSE INDICATOR or TRIP-INDICATOR • COMPLYING WITH IEC 269.1 and 2.1, NF EN 60269.1 & 2 NF C 63210 -


Original
PDF GPEU49 NH2GG50V250 K095045 M095047 NH3GG50V630
2008 - NH1GG50V250

Abstract: B0950 NH1GG50V200 NH0GG50V200
Text: A C A C H N N L L J J With blown fuse indicator With trip-indicator , gG gG gG gG gG gG gG gG gG With blown fuse indicator 0 / 40 0 / 50 0 / 63 0 / 80 0 , General Purpose IEC Fuses General Purpose IEC Fuses NH Fuses (Plain Blades) gG Plastic body with/without French striker gG 500V Size 0 and 1 from 40 to 250 A • BLADE-STYLE FUSES: WITH BLOWN FUSE INDICATOR or TRIP-INDICATOR • COMPLYING WITH IEC 269.1 AND 2.1 NF EN 60269.1 & 2 NF C 63210 - 63211 AND


Original
PDF GPEU47 NH1GG50V250 B0950 NH1GG50V200 NH0GG50V200
1653350001

Abstract: Lb 598 d ask 1 ld 35x75
Text: ASK 1 ASK 1 LD ASK 1 LD with blown fuse indicator and circuit disconnect ·tile'll II II i , For C ircuit Breakers, see pages 2/20-26 m jk KOKS 1/PE N o te for blown fuse indicator version , ith lever o pen, load is d isco n n ected co m pletely. N o te for blown fuse indicator version: In , 980273* 980275* 980277* 980279* 950331 990850 990851 OR Blown fuse (red) indicator ) versions , available with LED rt L , rt L t t i blown fuse indicators, which speed identificat on of fuse ailures and


OCR Scan
PDF
ATQ Fuses

Abstract: blown fuse indicator FLQ 6 fuse KLK Fuses A25Z-2 LR21455 A60Q
Text: Product Data Sheet 6SM30AXI Replace "X" with 1, 2, 3 or 4 for number of poles Midget Enclosed Fuse Holder 30 Amps, 600 Volts AC/DC with Blown Fuse Indicator 80V min for blown fuse indicator Wire Range: #6 - #14 AWG Cu Recommended Torque: 17.7 lbf-in. (2.0 N·m) Holds fuse size 13/32 , fuse rating for that physical size) · Copper wire only · 600 Volts AC/DC · Approved for 100,000 Amps , outside these ratings needs to be judged in the end-use application. Materials: · Fuse Clip: Copper


Original
PDF 6SM30AXI A13X-2, A25Z-2, A60Q-2, E35113 M1987, LR21455 MN35-2 ATQ Fuses blown fuse indicator FLQ 6 fuse KLK Fuses A25Z-2 LR21455 A60Q
blown fuse indicator

Abstract: ATQR Fuses can we replace ac fuse with dc fuse LR21455
Text: Product Data Sheet 6SC30AXI Replace "X" with 1, 2, 3 or 4 for number of poles Class CC Enclosed Fuse Holder 30 Amps, 600 Volts AC/DC with Blown Fuse Indicator 80V min for blown fuse indicator Wire Range: #6 - #14 AWG Cu Recommended Torque: 17.7 lbf-in. (2.0 N·m) Holds fuse size 13/32 , rating based on maximum fuse rating for that physical size) · Copper wire only · 600 Volts AC / DC · , Fuse Clip: Copper alloy, plated · Box Connector: Plated Steel · Insulator base: Glass-filled


Original
PDF 6SC30AXI E35113 M1987, LR21455 MN35-2 blown fuse indicator ATQR Fuses can we replace ac fuse with dc fuse LR21455
2005 - Not Available

Abstract: No abstract text available
Text: (Solid and Stranded)[MCM] (AWG) = 22-8 Operation/Application: Blown Fuse Indicator = Without Blown Fuse Indicator Type = None Application = In-Line Circuit Protection Amperes (Amps.) = 25.0 Packaging Related , ) Product Highlights: 0300 Series Block Series Fuse Block Block Type = Dovetail Base In-Line Circuit , Drawin g for all de sign activity) Product Type Features: Product Type = Fuse Block Screw Size = 10-32


Original
PDF
2005 - Tier

Abstract: 105-BU 1-1437392-7
Text: ) Conditions for Usage: Wire Range (Solid and Stranded)[MCM] (AWG) = 30-12 Temperature, Max. (°C) = 125 Blown Fuse Indicator = Without Operation/Application: Blown Fuse Indicator Type = None Wire Strip Length (mm


Original
PDF 105-BU 105-BU Tier 105-BU 1-1437392-7
2006 - buchanan fuse blocks

Abstract: mcm 750 fuse Tyco of blown fuse indicator deutsch fuse
Text: Operation/Application: q Application = In-Line Circuit Protection q Blown Fuse Indicator = Without q Blown Fuse Indicator Type = None q Amperes (Amps.) = 25.0 Packaging Related Features , Series Fuse Block Block Type = Fuse Mount Style = Channel Mount (Dovetail Base) Contact Type = , Product Details for 0352 - Tyco Electronics Product Type Features: q Product Type = Fuse Block q , Fuse q q Mount Style = Channel Mount (Dovetail Base) q Wire Range (Solid and Stranded


Original
PDF
2001 - A072F

Abstract: A480R5R-1HE A072F1DORO-6R A480R6R-1 A072F1DORO-9R A480R9R-1 A072B2DARO-18R A240R A480R12R-1 A072F1DORO-2R
Text: ® A480R MEDIUM VOLTAGE FUSES / R-RATED 4.8kV Ferrule Style Blown Fuse Indicator 2Lb. Force , ) Blown Fuse Indicator Extends 0.5 in. (12.7mm) when fuse opens, with 2 lbs. of force at end of travel , Fuse Indicator (Tripped Position) 1.0 (25.4) 3 (76) E Catalog Numbering System, Ratings , . The motor starter manufacturer generally specifies the R-rated fuse size. Amp-trap R-rated fuses are , . E 25 E AMP-TRAP® A240R MEDIUM VOLTAGE FUSES / R-RATED 2.4kV Ferrule Style Indicator


Original
PDF A240R/A480R/A072F/A072B A480R) A072F) A072F/A072B A072F A072B, A072F2 A480R5R-1HE A072F1DORO-6R A480R6R-1 A072F1DORO-9R A480R9R-1 A072B2DARO-18R A240R A480R12R-1 A072F1DORO-2R
blown fuse indicator

Abstract: No abstract text available
Text: Housing Material: Phenolic Wire Range (Solid and Stranded) [MCM] (AWG): 18-8 Fuse Puller: With Blown Fuse Indicator : Without Blown Fuse Indicator Type: None Copyright and , .): 25.0 Product Type: Terminal Block 12.70 [0.500] Block Type: Fuse Wire Strip Length


Original
PDF
FU520

Abstract: 115 663.23 29013 RC510 RC65 FEM8S FU525 115 661.21
Text: wiring of fuse /line applications. * Blocks with LED indicators are labeled "+" on the outside of the lever. The indicator can be reversed in the field if required. Spacing 8 mm (.315") M 4/8.SF 8 mm block. with blown fuse indicator M 4/8.SFL with neon lamp 110 V 220 V M 4/8.SFD with LED 24 V M 4 , with blown fuse indicator equipped with two test sockets 2 mm (.079") M 4/8.SFLT with neon lamp 100 V , M 4/8.SF - Up to 10A, 8 mm spacing, with or without indicator . With or without indicator , the


Original
PDF FU520 FU525 RC810 RC610 RC510 FU520 115 663.23 29013 RC510 RC65 FEM8S FU525 115 661.21
Buchanan

Abstract: CBB0500
Text: Housing Material: Nylon Wire Range (Solid and Stranded)[MCM] (AWG): 18-12 Blown Fuse Indicator : Without Blown Fuse Indicator Type: None Copyright and Privacy Statement Visit Tyco


Original
PDF CBB0500 Buchanan CBB0500
2006 - BUCHANAN 725

Abstract: No abstract text available
Text: 30 q Blown Fuse Indicator = Without Other: q Blown Fuse Indicator Type = None q


Original
PDF
2006 - buchanan terminal blocks

Abstract: No abstract text available
Text: Channel Mount (Dovetail Base) Wire Range (Solid and Stranded)[MCM] (AWG) = 22-10 q Blown Fuse Indicator = Without q Blown Fuse Indicator Type = None q Amperes (Amps.) = 30.0 q Housing


Original
PDF
3B106P

Abstract: B100
Text: ] (AWG): 18-8 Blown Fuse Indicator : Without Blown Fuse Indicator Type: None Copyright


Original
PDF 3B106P 3B106P B100
blown fuse indicator

Abstract: CBB1500
Text: ): 18-12 Blown Fuse Indicator : Without Blown Fuse Indicator Type: None Copyright and


Original
PDF CBB1500 CBB1500 blown fuse indicator
c 33740

Abstract: 110VDC LED Driver 16164-2 161644 220vac LED driver 33740 blown fuse C 337-40 T 10A H 250V fuse
Text: . Fuse terminals are available with LED blown fuse indicators, which speed identification of fuse failures and reduces costly down time. The maximum operating voltage for the indicator fuse blocks is determined by the LED's rating. A 2mA residual cur rent passes through the LED when the fuse is blown . Opening the fuseholder eliminates the residual current. ZSI 2.5 with blown fuse indicator for AC or DC , 2.5 with blown fuse Indicator must have power input to side oppo site hinge. If 2 blown fuse Single


OCR Scan
PDF
Supplyframe Tracking Pixel