The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
LTC2919CDDB-3.3#TRMPBF Linear Technology LTC2919 - Precision Triple/Dual Input UV, OV and Negative Voltage Monitor; Package: DFN; Pins: 10; Temperature Range: 0°C to 70°C
LTC2919HDDB-2.5#TRMPBF Linear Technology LTC2919 - Precision Triple/Dual Input UV, OV and Negative Voltage Monitor; Package: DFN; Pins: 10; Temperature Range: -40°C to 125°C
LTC2919HMS-5#PBF Linear Technology LTC2919 - Precision Triple/Dual Input UV, OV and Negative Voltage Monitor; Package: MSOP; Pins: 10; Temperature Range: -40°C to 125°C
LTC2919IMS-3.3#PBF Linear Technology LTC2919 - Precision Triple/Dual Input UV, OV and Negative Voltage Monitor; Package: MSOP; Pins: 10; Temperature Range: -40°C to 85°C
LTC2919CDDB-5#TRMPBF Linear Technology LTC2919 - Precision Triple/Dual Input UV, OV and Negative Voltage Monitor; Package: DFN; Pins: 10; Temperature Range: 0°C to 70°C
LTC2919HDDB-3.3#TRMPBF Linear Technology LTC2919 - Precision Triple/Dual Input UV, OV and Negative Voltage Monitor; Package: DFN; Pins: 10; Temperature Range: -40°C to 125°C

awm STYLE 2919 COMPUTER CABLE 30V Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
2012 - awm 2919 cable specification

Abstract: AWM STYLE 2919 low voltage COMPUTER CABLE "awm style 2919" 2919 low voltage COMPUTER CABLE Belden ul 2919 awm+2919+vw-1+low+voltage+computer
Text: Temperature Range: UL Temperature Rating: -30°C To +80°C 80°C (UL AWM Style 2919 ) Page 1 of 3 09-04-2012 , Capacitance Computer Cable for EIA RS-232/422 UL Temperature Rating: Bulk Cable Weight: Max. Recommended Pulling Tension: Min. Bend Radius/Minor Axis: 80°C (UL AWM Style 2919 ) 82 lbs/1000 ft. 115.500 lbs. 4.500 , 30 V RMS Description UL AWM Style 2919 300 V RMS CM Max. Recommended Current: Current 1.1 Amps , Capacitance Computer Cable for EIA RS-232/422 For more Information please call 1-800-Belden1 Description


Original
PDF RS-232/422 1-800-Belden1 73/23/EEC) 93/68/EEC. awm 2919 cable specification AWM STYLE 2919 low voltage COMPUTER CABLE "awm style 2919" 2919 low voltage COMPUTER CABLE Belden ul 2919 awm+2919+vw-1+low+voltage+computer
2003 - Belden ul 2919

Abstract: AWM STYLE 2919 low voltage COMPUTER CABLE awm 2919 cable specification belden 2919 Belden AWM 2919 awm+2919+vw-1+low+voltage+computer
Text: °C (UL AWM Style 2919 ) Bulk Cable Weight 30 lbs/1000 ft. Min. Bend Radius (Install) 2.5 in , . Operating Voltage - UL 30 V RMS (UL AWM Style 2919 ); 150 V RMS Other Maximum Continuous Currents 1 , Specification UL Style 2919 (30 V 80°C) FLAME TEST: UL Flame Test UL 1581 Vertical Tray PLENUM , 8132 Paired - Low Capacitance Computer Cables for EIA RS-232/485 For more information please , 3 % Coverage (%) 100 65 8132 Paired - Low Capacitance Computer Cables for EIA RS-232/485


Original
PDF RS-232/485 1-800-Belden1 Belden ul 2919 AWM STYLE 2919 low voltage COMPUTER CABLE awm 2919 cable specification belden 2919 Belden AWM 2919 awm+2919+vw-1+low+voltage+computer
2003 - awm 2919 cable specification

Abstract: Belden AWM 2919 belden 2919 Belden ul 2919 AWM STYLE 2919 low voltage COMPUTER CABLE awm STYLE 2919 15 pair 9829 Western Electric
Text: Ohms/1000 ft Max. Operating Voltage - UL 30 V RMS (UL AWM Style 2919 ); 300 V RMS (CM) Other , CHARACTERISTICS: Operating Temperature Range -30°C To +80°C UL Temperature Rating 80°C (UL AWM Style 2919 ) Bulk Cable Weight 41 lbs/1000 ft. Max. Recommended Pulling Tension 57 lbs. Min , STANDARDS: NEC/(UL) Specification CM CEC/C(UL) Specification CM AWM Specification UL Style , 9829 Paired - Low Capacitance Computer Cables for EIA RS-232/422 For more information please


Original
PDF RS-232/422 1-800-Belden1 awm 2919 cable specification Belden AWM 2919 belden 2919 Belden ul 2919 AWM STYLE 2919 low voltage COMPUTER CABLE awm STYLE 2919 15 pair 9829 Western Electric
2012 - Not Available

Abstract: No abstract text available
Text: AWM Style 2919 ) 99.709 Kg/Km Page 1 of 3 09-04-2012 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 8108 Multi-Conductor - Low Capacitance Computer Cable for EIA RS-232/422 , Description UL AWM Style 2919 300 V RMS CM Max. Recommended Current: Current 1.1 Amps per conductor @ , Capacitance Computer Cable for EIA RS-232/422 For more Information please call 1-800-Belden1 Description , Directive 2003/11/EC (BFR): CA Prop 65 (CJ for Wire & Cable ): MII Order #39 (China RoHS): CM CM UL Style


Original
PDF RS-232/422 1-800-Belden1 73/23/EEC) 93/68/EEC.
2012 - Not Available

Abstract: No abstract text available
Text: AWM Style 2919 ) 41 lbs/1000 ft. 2.500 in. Page 1 of 3 09-04-2012 Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 9931 Multi-Conductor - Low-Capacitance Computer Cable for EIA , °C (Ohm/1000 ft) 4.4 Max. Operating Voltage - UL: Voltage 30 V RMS (UL AWM Style 2919 ) 300 V RMS , Low-Capacitance Computer Cable for EIA RS-232/423 For more Information please call 1-800-Belden1 Description , (China RoHS): CM CM UL Style 2919 (30 V 80°C) Yes Yes Yes 01/01/2004 Yes Yes Yes Yes Flame Test UL


Original
PDF RS-232/423 1-800-Belden1 73/23/EEC) 93/68/EEC.
2012 - Not Available

Abstract: No abstract text available
Text: +80°C 80°C (UL AWM Style 2919 ) 197.931 Kg/Km 905.209 N 139.700 mm Applicable Specifications and , /EC (BFR): CA Prop 65 (CJ for Wire & Cable ): MII Order #39 (China RoHS): CM CM UL Style 2919 (30 V 80 , -232/422 Max. Operating Voltage - UL: Voltage 30 V RMS Description UL AWM Style 2919 300 V RMS CM , Capacitance Computer Cable for EIA RS-232/422 For more Information please call 1-800-Belden1 Description , Data METRIC MEASUREMENT VERSION 8118 Multi-Conductor - Low Capacitance Computer Cable for EIA RS


Original
PDF RS-232/422 1-800-Belden1 73/23/EEC) 93/68/EEC.
2012 - Not Available

Abstract: No abstract text available
Text: AWM Style 2919 ) 44.646 Kg/Km 63.500 mm Page 1 of 3 09-04-2012 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 8132 Multi-Conductor - Low Capacitance Computer Cable for EIA , Directive 2003/11/EC (BFR): CA Prop 65 (CJ for Wire & Cable ): MII Order #39 (China RoHS): CL2 UL Style 2919 , Capacitance Computer Cable for EIA RS-232/485 For more Information please call 1-800-Belden1 Description , Style 2919 ); 150 V RMS Max. Recommended Current: Current 1 Amp per conductor @ 25°C Notes


Original
PDF RS-232/485 1-800-Belden1 73/23/EEC) 93/68/EEC.
2012 - Not Available

Abstract: No abstract text available
Text: Axis: -30°C To +80°C 80°C (UL AWM Style 2919 ) 52.087 Kg/Km 68.580 mm Page 1 of 3 09-04-2012 , 30 V RMS (UL AWM Style 2919 ); 150 V RMS Max. Recommended Current: Current 0.9 Amps per conductor , Capacitance Computer Cable for EIA RS-232/485 For more Information please call 1-800-Belden1 Description , Capacitance Computer Cable for EIA RS-232/485 Applicable Specifications and Agency Compliance (Overall , (China RoHS): CL2 UL Style 2919 (30 V 80°C) Yes Yes Yes 01/01/2004 Yes Yes Yes Yes Flame Test UL


Original
PDF RS-232/485 1-800-Belden1 73/23/EEC) 93/68/EEC.
2012 - Not Available

Abstract: No abstract text available
Text: °C (UL AWM Style 2919 ) 40.181 Kg/Km 53.975 mm Applicable Specifications and Agency Compliance (Overall , Max. Operating Voltage - UL: Voltage 30 V RMS (UL AWM Style 2919 ) 300 V RMS Max. Recommended , Low-Capacitance Computer Cable for EIA RS-232/RS423 For more Information please call 1-800-Belden1 Description , Cable for EIA RS-232/RS423 CEC/C(UL) Specification: AWM Specification: EU CE Mark: EU Directive 2000/53 , ): CM UL Style 2919 (30 V 80°C) Yes Yes Yes 01/01/2004 Yes Yes Yes Yes Flame Test UL Flame Test


Original
PDF RS-232/RS423 1-800-Belden1 73/23/EEC) 93/68/EEC.
2006 - Not Available

Abstract: No abstract text available
Text: °C (UL AWM Style 2919 ) Bulk Cable Weight 41 lbs/1000 ft. Max. Recommended Pulling Tension 57 , Deg. C 4.4 Ohms/1000 ft Max. Operating Voltage - UL 30 V RMS (UL AWM Style 2919 ); 300 V RMS , 9829 Paired - Low Capacitance Computer Cable for EIA RS-232/422 For more information please , UL Style 2919 (30 V 80°C) EU CE Mark (Y/N) Yes EU RoHS Compliant (Y/N) Yes EU RoHS , Capacitance Computer Cable for EIA RS-232/422 PUT-UPS AND COLORS: Item Description 9829 060100 2 PR #24


Original
PDF RS-232/422 1-800-Belden1 73/23/EEC) 93/68/EEC.
2006 - awm 2919 cable specification

Abstract: No abstract text available
Text: Temperature Range -30°C To +80°C UL Temperature Rating 80°C (UL AWM Style 2919 ) Bulk Cable Weight , COMPLIANCE: APPLICABLE STANDARDS: NEC/(UL) Specification CL2 AWM Specification UL Style 2919 (30 V , Voltage - UL 30 V RMS (UL AWM Style 2919 ); 150 V RMS Max. Recommended Current 0.9 Amps per , 8133 Paired - Low Capacitance Computer Cable for EIA RS-232/485 For more information please , 8133 Paired - Low Capacitance Computer Cable for EIA RS-232/485 OUTER SHIELD DRAIN WIRE : Outer


Original
PDF RS-232/485 1-800-Belden1 73/23/EEC) 93/68/EEC. awm 2919 cable specification
2012 - AWM STYLE 2919 low voltage COMPUTER CABLE

Abstract: No abstract text available
Text: : Bulk Cable Weight: Min. Bend Radius (Install)/Minor Axis: -30°C To +80°C 80°C (UL AWM Style 2919 , Prop 65 (CJ for Wire & Cable ): MII Order #39 (China RoHS): CL2 UL Style 2919 (30 V 80°C) Yes Yes Yes 01 , @ 20°C (Ohm/km) 16.7331 Max. Operating Voltage - UL: Voltage 30 V RMS (UL AWM Style 2919 ); 150 V , Capacitance Computer Cable for EIA RS-232/485 For more Information please call 1-800-Belden1 Description , MEASUREMENT VERSION 8132 Multi-Conductor - Low Capacitance Computer Cable for EIA RS-232/485 Applicable


Original
PDF RS-232/485 1-800-Belden1 73/23/EEC) 93/68/EEC. AWM STYLE 2919 low voltage COMPUTER CABLE
2012 - Not Available

Abstract: No abstract text available
Text: . Bend Radius/Minor Axis: -30°C To +80°C 80°C (UL AWM Style 2919 ) 58 lbs/1000 ft. 3.300 in. Applicable , Prop 65 (CJ for Wire & Cable ): MII Order #39 (China RoHS): CL2 UL Style 2919 (30 V 80°C) Yes Yes Yes 01 , °C (Ohm/1000 ft) 3.7 Max. Operating Voltage - UL: Voltage 30 V RMS (UL AWM Style 2919 ); 150 V RMS , Capacitance Computer Cable for EIA RS-232/485 For more Information please call 1-800-Belden1 Description , 8138 Multi-Conductor - Low Capacitance Computer Cable for EIA RS-232/485 Notes: Datalene® insulation


Original
PDF RS-232/485 1-800-Belden1 73/23/EEC) 93/68/EEC.
2011 - Not Available

Abstract: No abstract text available
Text: : -30°C To +80°C UL Temperature Rating: 80°C (UL AWM Style 2919 ) Bulk Cable Weight: 52 lbs , . Operating Voltage - UL: Voltage 30 V RMS (UL AWM Style 2919 ) 300 V RMS Max. Recommended Current , Low-Capacitance Computer Cable for EIA RS-232/423 For more Information please call 1-800-Belden1 Description , Specification: UL Style 2919 (30 V 80°C) EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU , Specifications & Technical Data ENGLISH MEASUREMENT VERSION 9934 Multi-Conductor - Low-Capacitance Computer


Original
PDF RS-232/423 1-800-Belden1 73/23/EEC) 93/68/EEC.
2012 - AWM STYLE 2919 low voltage COMPUTER CABLE

Abstract: No abstract text available
Text: Radius/Minor Axis: -20°C To +80°C 80°C (UL AWM Style 2919 ) 29 lbs/1000 ft. 33 lbs. 2.750 in. Page 1 of , Prop 65 (CJ for Wire & Cable ): MII Order #39 (China RoHS): CM CM UL Style 2919 (30 V 80°C) Yes Yes Yes , . Operating Voltage - UL: Voltage 30 V RMS (UL AWM Style 2919 ); 300 V RMS Max. Recommended Current , Low Capacitance Computer Cable for EIA RS-232/422 For more Information please call 1-800 , Multi-Conductor - Low Capacitance Computer Cable for EIA RS-232/422 Applicable Specifications and Agency


Original
PDF RS-232/422 1-800-Belden1 73/23/EEC) 93/68/EEC. AWM STYLE 2919 low voltage COMPUTER CABLE
2005 - awm 2919 cable specification

Abstract: No abstract text available
Text: UL Temperature Rating 80°C (UL AWM Style 2919 ) Bulk Cable Weight 47 lbs/1000 ft. Min , Deg. C 4.4 Ohms/1000 ft Max. Operating Voltage - UL 30 V RMS (UL AWM Style 2919 ), 300 V RMS , 9830 Paired - Low Capacitance Computer Cable for EIA RS-232/422 For more information please , STANDARDS: NEC/(UL) Specification CM CEC/C(UL) Specification CM AWM Specification UL Style , Capacitance Computer Cable for EIA RS-232/422 PUT-UPS AND COLORS: Item Description 9830 0601000 3 PR


Original
PDF RS-232/422 1-800-Belden1 73/23/EEC) 93/68/EEC. awm 2919 cable specification
2012 - Not Available

Abstract: No abstract text available
Text: /Minor Axis: -30°C To +80°C 80°C (UL AWM Style 2919 ) 96.733 Kg/Km 101.600 mm Applicable Specifications , for Wire & Cable ): MII Order #39 (China RoHS): CL2 UL Style 2919 (30 V 80°C) Yes Yes Yes 01/01/2004 , . Operating Voltage - UL: Voltage 30 V RMS (UL AWM Style 2919 ); 150 V RMS Max. Recommended Current , Low Capacitance Computer Cable for EIA RS-232/485 For more Information please call 1-800 , - Low Capacitance Computer Cable for EIA RS-232/485 2.3368 13 Mechanical Characteristics


Original
PDF 8142FO RS-232/485 1-800-Belden1 73/23/EEC) 93/68/EEC.
2012 - AWM STYLE 2919 low voltage COMPUTER CABLE

Abstract: No abstract text available
Text: Temperature Rating: Bulk Cable Weight: -30°C To +80°C 80°C (UL AWM Style 2919 ) 63.993 Kg/Km Page 1 of 3 , 30 V RMS (UL AWM Style 2919 ); 150 V RMS Max. Recommended Current: Current 0.9 Amps per conductor , Capacitance Computer Cable for EIA RS-232/485 For more Information please call 1-800-Belden1 Description , Low Capacitance Computer Cable for EIA RS-232/485 Bulk Cable Weight: Min. Bend Radius/Minor Axis , RoHS): CL2 UL Style 2919 (30 V 80°C) Yes Yes Yes 01/01/2004 Yes Yes Yes Yes Flame Test UL Flame


Original
PDF RS-232/485 1-800-Belden1 73/23/EEC) 93/68/EEC. AWM STYLE 2919 low voltage COMPUTER CABLE
2012 - Not Available

Abstract: No abstract text available
Text: +80°C 80°C (UL AWM Style 2919 ) 43 lbs/1000 ft. 60.500 lbs. 3.250 in. Page 1 of 3 09-04-2012 Detailed , Cable ): MII Order #39 (China RoHS): CM CM UL Style 2919 (30 V 80°C) Yes Yes Yes 01/01/2004 Yes Yes Yes , /1000 ft) 4.2 Max. Operating Voltage - UL: Voltage 30 V RMS 300 V RMS Description UL AWM Style 2919 , Capacitance Computer Cable for EIA RS-232/422 For more Information please call 1-800-Belden1 Description , - Low Capacitance Computer Cable for EIA RS-232/422 Put Ups and Colors: Item # 8105 060100 8105


Original
PDF RS-232/422 1-800-Belden1 73/23/EEC) 93/68/EEC.
2012 - awm 2919 cable specification

Abstract: No abstract text available
Text: AWM Style 2919 ) 30 lbs/1000 ft. 2.300 in. Applicable Specifications and Agency Compliance (Overall , : Voltage 30 V RMS (UL AWM Style 2919 ) 300 V RMS Max. Recommended Current: Current 1.8 Amps per , Low-Capacitance Computer Cable for EIA RS-232/423 For more Information please call 1-800-Belden1 Description , Data ENGLISH MEASUREMENT VERSION 9927 Multi-Conductor - Low-Capacitance Computer Cable for EIA RS , RoHS): CM CM UL Style 2919 (30 V 80°C) Yes Yes Yes 01/01/2004 Yes Yes Yes Yes Flame Test UL Flame


Original
PDF RS-232/423 1-800-Belden1 73/23/EEC) 93/68/EEC. awm 2919 cable specification
2012 - awm 2919 cable specification

Abstract: AWM STYLE 2919 low voltage COMPUTER CABLE
Text: +80°C 80°C (UL AWM Style 2919 ) 66.969 Kg/Km 293.581 N 82.550 mm Page 1 of 3 09-04-2012 Detailed , Cable ): MII Order #39 (China RoHS): CM CM UL Style 2919 (30 V 80°C) Yes Yes Yes 01/01/2004 Yes Yes Yes , Resistance: DCR @ 20°C (Ohm/km) 42.653 Max. Operating Voltage - UL: Voltage 30 V RMS (UL AWM Style 2919 , Capacitance Computer Cable for EIA RS-232/422 For more Information please call 1-800-Belden1 Description , MEASUREMENT VERSION 1423A Multi-Conductor - Low Capacitance Computer Cable for EIA RS-232/422 Notes


Original
PDF RS-232/422 1-800-Belden1 73/23/EEC) 93/68/EEC. awm 2919 cable specification AWM STYLE 2919 low voltage COMPUTER CABLE
2012 - awm 2919 cable specification

Abstract: 9938
Text: °C (UL AWM Style 2919 ) 190.490 Kg/Km 120.650 mm Applicable Specifications and Agency Compliance , for Wire & Cable ): MII Order #39 (China RoHS): CM CM UL Style 2919 (30 V 80°C) Yes Yes Yes 01/01/2004 , Voltage - UL: Voltage 30 V RMS (UL AWM Style 2919 ) 300 V RMS Max. Recommended Current: Current 1.5 , Low-Capacitance Computer Cable for EIA RS-232/423 For more Information please call 1-800-Belden1 Description , Low-Capacitance Computer Cable for EIA RS-232/423 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37


Original
PDF RS-232/423 1-800-Belden1 73/23/EEC) 93/68/EEC. awm 2919 cable specification 9938
2012 - Not Available

Abstract: No abstract text available
Text: Radius/Minor Axis: -30°C To +80°C 80°C (UL AWM Style 2919 ) 34 lbs/1000 ft. 27.500 lbs. 2.750 in. Page , 2003/11/EC (BFR): CA Prop 65 (CJ for Wire & Cable ): MII Order #39 (China RoHS): CM CM UL Style 2919 (30 , . Operating Voltage - UL: Voltage 30 V RMS Description UL AWM Style 2919 300 V RMS CM Max. Recommended , Capacitance Computer Cable for EIA RS-232/422 For more Information please call 1-800-Belden1 Description , 8102 Multi-Conductor - Low Capacitance Computer Cable for EIA RS-232/422 Applicable Specifications


Original
PDF RS-232/422 1-800-Belden1 73/23/EEC) 93/68/EEC.
2012 - AWM STYLE 2919 low voltage COMPUTER CABLE

Abstract: awm 2919 cable specification Belden AWM 2919 belden 2919 Belden ul 2919 UL 2919 AWM CABLE
Text: 30 V RMS (UL AWM Style 2919 ); 300 V RMS Max. Recommended Current: Current 2.1 Amps per conductor , Capacitance Computer Cable for EIA RS-232/422 For more Information please call 1-800-Belden1 Description , Weight: Max. Recommended Pulling Tension: Min. Bend Radius/Minor Axis: -20°C To +80°C 80°C (UL AWM Style , Technical Data METRIC MEASUREMENT VERSION 9680 Multi-Conductor - Low Capacitance Computer Cable for EIA , (China RoHS): CM CM UL Style 2919 (30 V 80°C) Yes Yes Yes 01/01/2004 Yes Yes Yes Yes Flame Test UL


Original
PDF RS-232/422 1-800-Belden1 73/23/EEC) 93/68/EEC. AWM STYLE 2919 low voltage COMPUTER CABLE awm 2919 cable specification Belden AWM 2919 belden 2919 Belden ul 2919 UL 2919 AWM CABLE
2006 - Belden 8105

Abstract: 31296
Text: Temperature Rating 80°C (UL AWM Style 2919 ) Bulk Cable Weight 52.5 lbs/1000 ft. Max. Recommended , AWM Specification UL Style 2919 (30 V 80°C) EU CE Mark (Y/N) Yes EU RoHS Compliant (Y/N , Resistance @ 20 Deg. C 4.2 Ohms/1000 ft Max. Operating Voltage - UL 30 V RMS (UL AWM Style 2919 , 8105 Paired - Low Capacitance Computer Cable for EIA RS-232/422 For more information please , Page 1 of 3 % Coverage (%) 100 65 8105 Paired - Low Capacitance Computer Cable for EIA RS


Original
PDF RS-232/422 1-800-Belden1 73/23/EEC) 93/68/EEC. Belden 8105 31296
Supplyframe Tracking Pixel