The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
LT1166CS8#TR Linear Technology LT1166 - Power Output Stage Automatic Bias System; Package: SO; Pins: 8; Temperature Range: 0°C to 70°C
LT3420EDD-1 Linear Technology LT3420 - Photoflash Capacitor Chargers with Automatic Refresh; Package: DFN; Pins: 10; Temperature Range: -40°C to 85°C
LT3420EDD#PBF Linear Technology LT3420 - Photoflash Capacitor Chargers with Automatic Refresh; Package: DFN; Pins: 10; Temperature Range: -40°C to 85°C
LT3420EDD-1#TR Linear Technology LT3420 - Photoflash Capacitor Chargers with Automatic Refresh; Package: DFN; Pins: 10; Temperature Range: -40°C to 85°C
LT3420EMS Linear Technology LT3420 - Photoflash Capacitor Chargers with Automatic Refresh; Package: MSOP; Pins: 10; Temperature Range: -40°C to 85°C
LTC2955IDDB-2#TRPBF Linear Technology LTC2955 - Pushbutton On/Off Controller with Automatic Turn-On; Package: DFN; Pins: 10; Temperature Range: -40°C to 85°C

automatic door opening sensor Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
welding machine wiring diagram

Abstract: sensor detector door opening system dc welding machine circuit diagram Electronic security code lock system - Door Lock - Safe Lock circuit diagram iec 60617 Electric Welding Machine diagram automatic door opening sensor IEC60947-5-1 F3SP welding machine diagram
Text: opening contacts and safety door switches must be used. · The principles of redundancy and diversity must , of the door . That can result in a significant gap in the opening edge on very wide guard doors , equipped with functions such as a direct opening mechanism for switches and a forcibly guided mechanism , switch · A pull-cord operated switch 2. Requirements · Electric contacts must have a direct opening , method (6) The automatic generation of an emergency stop signal in the event that the wire breaks or


Original
PDF
Not Available

Abstract: No abstract text available
Text: the fault either by pressing Emergency Stop, opening the guard door or disconnecting the air supply , from the machine to clear the fault either by pressing Emergency Stop, opening the guard door or , , opening the guard door or disconnecting the air supply. If any of these are done their respective faults , UNCONTROLLED COPY Page 22 of 66 RAST 2.5 Power Semi-Automatic Terminator Machine opening the guard door , . opening the guard door or disconnecting the air supply. If any of these are done their respective faults


Original
PDF TM-623006000
air cylinder festo

Abstract: PILZ PNOZ X3 safety relay
Text: disconnect switch on electrical cabinet door . 2. Touch screen will reset. 3. Laser sensor motor will , to clear the fault either by pressing Emergency Stop, opening the guard door or disconnecting the , from the machine to clear the fault either by pressing Emergency Stop, opening the guard door or , either by pressing Emergency Stop, opening the guard door or disconnecting the air supply. If any of , fault either by pressing Emergency Stop, opening the guard door or disconnecting the air supply. If


Original
PDF ATS-623006200 ADJUST0-1505 air cylinder festo PILZ PNOZ X3 safety relay
FANUC ELECTRICAL MANUAL

Abstract: Fanuc spindle motor hand movement based fan speed control T21i T14iFb fanuc 31i T21iFLb 10kva fanuc robodrill fanuc model
Text: . Enables robot jogging, robot hand opening /closing, automatic side door opening /closing, system status d , opening door : 730mm(Fb) Column cover (FL-net/DeviceNet/PROFIBUS-DP) Programmable mirror image Splashguard wide opening door : 1100mm(FLb) Rotary joint for DDR Fast data server (G51.1/G50.1) Automatic front door opening / Adjustment of center height,Adjustment (with Compact Flash Memory 1GB , Accessory(option) Wide opening door : 730mm for -T14iFb 1,100mm for -T14iFLb Top cover Coolant


Original
PDF contr-5512 iFsb/T21 iFb/T21 iFLb/T14 iFsb/T14 FANUC ELECTRICAL MANUAL Fanuc spindle motor hand movement based fan speed control T21i T14iFb fanuc 31i T21iFLb 10kva fanuc robodrill fanuc model
telemecanique selector

Abstract: telemecanique limit switch telemecanique push relay safety telemecanique XPS-MC32 XPS-MC16 off delay timer telemecanique TSXPCX1031 Telemecanique telemecanique hand switch
Text: device symbols: protection door with one opening contact, protection door with two opening contacts and protection door with lock (three opening contacts). The parameter setting window provides the following , . 21 Protection door with one channel, without lock . 22 Protection door with two channels, without lock . 22 Protection door with two channels, with lock


Original
PDF XPS-MC16 XPS-MC32, 26-GB 2GB/157/01 telemecanique selector telemecanique limit switch telemecanique push relay safety telemecanique XPS-MC32 off delay timer telemecanique TSXPCX1031 Telemecanique telemecanique hand switch
1999 - Not Available

Abstract: No abstract text available
Text: external manual restart sequence. After opening the door , the two external safety switch contacts Sa and , 1mA to 7A (5 mm gold plated contacts allow low current) • Automatic start or manual start modes â , housing 22,5 mm / 0.89 in width APPLICATIONS • Emergency-stop circuits on machines • Door , . In the automatic start mode, the module accepts immediate input from the safety device (light , (-5 %, +10 %) DC: 2 W (approximately) 50 to 60 Hz Manual START function: 40 ms Automatic START


Original
PDF 98/37/EC, FF-SRS5925
1999 - Not Available

Abstract: No abstract text available
Text: safety door monitoring (with cross fault monitoring, automatic start mode) Power 24 Vdc/Vac (+) S1 , , but only after initiating an external manual restart sequence. After opening the door , the two , 1mA to 7A (5 µm gold plated contacts allow low current) • Automatic start or manual start modes , housing 22,5 mm / 0.89 in width APPLICATIONS • Emergency-stop circuits on machines • Door , contacts (13/14, 23/24) will close and the normally closed contact (31/32) will open. In the automatic


Original
PDF 98/37/EC, FF-SRS5925
F39-MDG

Abstract: Safety bus EN954-1 GS-ET-15 NL-2132 EN 50041 IEC 60947-5-1 limit switch
Text: switches General safety limit switches Door monitoring Creating a safe industrial world , curtain F3SH multi-beam sensor 6 8 Type 2 & Type 4 F3S-TGR-SBX-KXC safety light , E3FS single-beam sensor 10 G9SA/B/X 12 14 Safety relay unit G9SX modular series , Safety light curtain, F3SH ­ Multi-beam sensor Omron's F3SN is a Type 4 sensor that provides , sensor that can detect a person entering a dangerous 189 mm to 1822 mm, with a detection distance of


Original
PDF
motion sensor doppler

Abstract: automatic door infrared sensor microwave motion sensor WB-010 10.525 GHZ Microwave Motion Sensor module X-Band Motion Detector automatic door opening sensor microwave motion sensors microwave sensor Dielectric Resonator Oscillator DRO WB-010
Text: work together with Passive Infrared (PIR) sensor . It can also be used for auto-door opening and , ) Microwave-PIR motion detector Automatic door opener Lighting control Speed measurement Characteristics , WB-010 10.525 GHZ Microwave Motion Sensor module General description WB-010 Miniature Microwave Motion Sensor is a X-Band Bi-Static Doppler transceiver Module. It s built-in Dielectric Resonator , Federal Commission(FCC) Rules, Part 15,Section 15.245 (use within a building or to open building door


Original
PDF WB-010 WB-010 WB-010signed 100HZ motion sensor doppler automatic door infrared sensor microwave motion sensor WB-010 10.525 GHZ Microwave Motion Sensor module X-Band Motion Detector automatic door opening sensor microwave motion sensors microwave sensor Dielectric Resonator Oscillator DRO
automatic door infrared sensor

Abstract: No abstract text available
Text: Motion Radar Sensor RAD Series • K-Band radar sensor compatible with all types of automatic doors. • 3-D adjustable sensor position offers precise orientation of the activation pattern. â , Motion Radar Sensor is a digital uni or bidirectional motion sensor for trouble-free opening of all types of automatic doors (sliding, swinging, folding, revolving, speed-doors, overhead doors, etc , ˜ 3 (1/8”) Door Status: OPEN: Locked open CLOSE: Locked closed AUTO: automatic detection mode


Original
PDF UL325 automatic door infrared sensor
2002 - Not Available

Abstract: No abstract text available
Text: change or power interruption Penlift: Automatic on door opening ; pens are door mounted and swing clear , Mounting Sensor ߜ Convenient Front Panel Programming ߜ 200 mm (8") Chart for 1, 7, or 32 , Recorder Available Complete with 120 Assorted Double-Sided Charts, 2 Sets of Pens, 6' Remote Sensor , relay contact closes and an audible alarm sounds. Flipping open a hinged front panel door permits , recorder. The door comes with a locking mechanism. The user may select 1, 7 or 32 day operation, program


Original
PDF CT485B 32-Day CT485-CWC D-112 CT485-MW(
2002 - CT485-CWC-6

Abstract: No abstract text available
Text: °F, 1% RH Zero: Automatic zero during chart change or power interruption Penlift: Automatic on door opening ; pens are door mounted and swing clear of the chart when door opens Pen Arms: Clear plastic to , Mounting Sensor ߜ Convenient Front Panel Programming ߜ 200 mm (8") Chart for 1, 7, or 32 , with 120 Assorted Double-Sided Charts, 2 Sets of Pens, 6' Remote Sensor Cable, Wall Mounting Kit , and an audible alarm sounds. Flipping open a hinged front panel door permits access to the power


Original
PDF CT485B 32-Day CT485B-RP-G CT485-CWC CT485-CWC-6
Not Available

Abstract: No abstract text available
Text: IRS01 Product Description Ordering Key IRS Long range sensor is a digital unidirectional motion sensor for trouble-free opening of all types of industrial automatic doors. It can be adapted , Long Range Motion Radar Sensor IRS Series • • • • • • • Vehicle and , motion towards or away from the sensor . Like most of other microwave detectors equipped with planar flat antenna, the sensor works on echo doppler signal for detecting movements. IRS 01 Approvals


Original
PDF CE0682, UL325 IRS01
hand movement based fan speed control

Abstract: FANUC ELECTRICAL MANUAL T21i touch screen controlled robot fanuc robodrill fanuc robot i 410 300 manual cell phone CONTROLLED ROBOT fanuc 31i 10kva fanuc robot
Text: /closing, automatic side door opening /closing, system status d i s p l a y, a n d r o b o t p r o g r a m , opening door : 730mm(Fa) Column cover (FL-net/DeviceNet/PROFIBUS-DP) Scaling (G51/G50) Splashguard wide opening door : 1100mm(FLa) Rotary joint for DDR Fast data server Programmable mirror image Automatic front door opening / Adjustment of center height,Adjustment (with Compact Flash Memory 1GB) (G51 , opening door : 730mm for -T14i Fa 1,100mm for -T14i FLa Top cover Coolant unit (tank) Signal


Original
PDF -T21i Fsa/T21i Fa/T21i a/T14i Fsa/T14i hand movement based fan speed control FANUC ELECTRICAL MANUAL T21i touch screen controlled robot fanuc robodrill fanuc robot i 410 300 manual cell phone CONTROLLED ROBOT fanuc 31i 10kva fanuc robot
2002 - FF-SNC400R2

Abstract: Honeywell m7420a1009-7 FF-SNC200R2 FF-SNC400RE SS316 FF-SNC1SA03PA R1506 SS316 screws Honeywell 38240 Honeywell 38240 meylan
Text: Supply voltage: 24 Vdc/Vac ±15 %; 110 Vac ±15 % (only available for the 4- sensor control unit) · Response time of the control unit: 15 ms · Manual or automatic restart · LED status indicator · 2- sensor control unit: (DIN rail mount 22,5 mm / 0.89 in width) 4- sensor control unit: (DIN rail mount 75 mm / 2.95 in width) 5- sensor extension module: (DIN rail mount 22,5 / 0.89 in width) TYPICAL APPLICATIONS , ): · Machine door or casting "open/closed" detection · Guard-in-place detection, gate/access door


Original
PDF 107097-13-EN FF-SNC400R2 Honeywell m7420a1009-7 FF-SNC200R2 FF-SNC400RE SS316 FF-SNC1SA03PA R1506 SS316 screws Honeywell 38240 Honeywell 38240 meylan
2002 - FF-SNC1SA05PA

Abstract: FF-SNC200R2 NFPA-79 FF-SNC400R2 automatic sliding door FF-SNC1SA05PA-QD FF-SNC1SA-05-QD
Text: fixed part of the safety switch to the machine frame and the actuator on to the opening edge of the door , of the safety switch to the machine frame and the actuator onto the opening edge of the door (Fig. 5 , FF-SNC is especially suited for applications where perfect door alignment can not be attained. The FF-SNC , installation alignment. The sensor and actuator small size makes it usable under tight space requirements. The , switches. The indicators located on the front cover of both control units provide individual door status


Original
PDF CC1816-025033 FF-SNC1SA05PA FF-SNC200R2 NFPA-79 FF-SNC400R2 automatic sliding door FF-SNC1SA05PA-QD FF-SNC1SA-05-QD
S41 sensor Magnetic

Abstract: Elan SRB sensor s42 Schmersal sliding Door control circuit S43-S44 s41 sensor Schmersal IEC 60947-5-1
Text: . . . . . . 5 8.3 Sensor configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . , automatic reset* Reset monitored* Reset not monitored, optionally automatic reset*, switch-off level 2 , short detection* CA/Q Reset not monitored, optionally automatic reset*, switch-off level 2 with , defined as the opening of enabling circuits 13-24 when the inputs S31-S32 and/or S41-S42 (S43-S44) are opened and as the opening of enabling circuits 13-14 and 13-24 when the inputs S12 and/or S22 are


Original
PDF 202CS 202CS/T 202CA/T 202CA/QT 202CA 202CA/Q 2006/42/EC: SRB202C. S41 sensor Magnetic Elan SRB sensor s42 Schmersal sliding Door control circuit S43-S44 s41 sensor Schmersal IEC 60947-5-1
1997 - motion sensor doppler

Abstract: microwave RADAR motion sensors doppler sensor microwave motion sensors 24 GHz Microwave Doppler Radar Speed Sensor motion DOPPLER motion sensor doppler effect motion sensor based on doppler effect microwave motion sensor automatic door opening sensor
Text: frequency (fO = 2.45 GHz) the sensor module KMY 24 can be registered for approval worldwide. 3.2 Applications Due to the compact size of the sensor modules, they are ideally suited for applications where space is at a premium. Typical applications are: · · · · · sanitation control automatic door , sensor . The reflected radiation is received by the patch antenna and mixed with the original radiation , approaching the sensor . This allows determination of the direction of the motion. The KMY 10 sensor module


Original
PDF
automatic door opening sensor

Abstract: OMH-RL25 garage door photoelectric H160 mounting bracket for transmitter
Text: units together A Series 29 photoelectric sensor monitors the threshold of an overhead door in a , Doors Long-range Retro-reflective Sensors A parking garage automatic gate counts the number of vehicles that enter or exit with a Series 29 photoelectric sensor . This is an inexpensive alternative to , retro-reflective mode, meaning that the sensor 's lens is mounted facing a cornercube style reflector. To optimize sensor performance, the reflector should be within the specified operating range of the sensor and at


Original
PDF
2013 - D8227

Abstract: D8203 D1260W D8128D
Text: . The keypad and annunciator show all testing data. An automatic sensor reset feature saves time; you , interface keypads • Four alarm‑output patterns • Automatic bell test • Programmable bell , , control relays, control authority levels, and control door access User Interface • Supervision of , present at opening • Two unique passcodes on the same keypad to disarm an area Without the second , Function A custom function activates when user credentials are presented to a D9210B door controller


Original
PDF D7412GV2 D5200 D9210BLC D8227 D8203 D1260W D8128D
24 GHz Microwave Doppler Radar Speed Sensor

Abstract: microwave motion sensors microwave RADAR motion sensors motion sensor doppler 24 GHz Microwave Sensor speed sensors Siemens siemens speed sensor motion DOPPLER motion sensor based on doppler effect automatic door opening sensor
Text: ) the sensor module KMY 24 can be registered for approval worldwide. 3.2 Applications Due to the compact size of the sensor modules, they are ideally suited for applications where space is at a premium. Typical applications are: · · · · · sanitation control automatic door opening lighting control , target. A Doppler shift occurs in the reflected radiation, if the target is moving relative to the sensor , sensor . This allows determination of the direction of the motion. The KMY 10 sensor module fulfills the


OCR Scan
PDF
1999 - 98/37/EC

Abstract: No abstract text available
Text: after initiating an external manual restart sequence. After opening the door , the two external safety , allow low current) • Line fault detection and detection of blocked start push-button • Automatic , APPLICATIONS • Emergency stop circuits on machines • Door protection • Conveyors/transfer lines â , (13/14.63/64) will close and the normally closed contact (81/82) will open. In the automatic start , ms Automatic START function: 1 s 23 Vdc (provided by control module) / 0 V 110 mAdc 21 Vdc when


Original
PDF 98/37/EC, Vdc/230 S33/S34; FF-SRS5988 98/37/EC
2014 - schneider NS1250N

Abstract: schneider overload relay WIRING DIAGRAM micrologic trip schneider merlin gerin switchgear
Text: door cutout. Disconnecting the circuit breaker is possible without opening the door and exposing live parts. Figure 2: Racking Handle and Mechanism Door Escutcheon Closing and Opening Push Buttons , which can be manually or motor charged. The closing time is less than five cycles. Closing and opening , fixed mounts, with either 3P or 4P construction. Field-Installable Trip Units, Sensor Plugs and Accessories: Trip units, sensor plugs and most accessories are field installable with only the aid of a


Original
PDF 0613CT0001 R05/14 R05/14 R12/13 schneider NS1250N schneider overload relay WIRING DIAGRAM micrologic trip schneider merlin gerin switchgear
1999 - Not Available

Abstract: No abstract text available
Text: Dual-channel safety door monitoring (with cross fault monitoring, automatic start mode) Protective gates are , . After opening the door , the two external safety switch contacts S1 and S2 will open (as illustrated , allow low current) • Line fault detection and detection of blocked start push-button • Automatic , APPLICATIONS • Emergency stop circuits on machines • Door protection • Conveyors/transfer lines â , automatic start mode, the module accepts input from the safety device (light curtain, mat, safety switches


Original
PDF 98/37/EC, Vdc/230 S33/S34; FF-SRS5988
2001 - D9112

Abstract: Radionics Radionics D9112 D192D automatic door bell sensor detector door opening system d1640 D1255 D8132 Radionics D1255
Text: . Automatic sensor reset feature allows continued testing of devices without time consuming trips to , supervision Automatic reset circuit protectors On-board CPU watchdog warning buzzer and diagnostic LEDs , are programmable Optional dual phone line switcher monitors 2 phone lines Automatic test and , · 2-amp alarm power @ 12 VDC 1.4-amp aux power @ 12 VDC 4 alarm output patterns Automatic bell , (Skeds) arm, disarm, bypass and unbypass points, control relays, control authority levels, control door


Original
PDF D9412G/D7412G 1000-event D9412G/D7412G 47487B D9112 Radionics Radionics D9112 D192D automatic door bell sensor detector door opening system d1640 D1255 D8132 Radionics D1255
Supplyframe Tracking Pixel