The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
20C330 TE Connectivity Ltd RELAY ANCHOR CLIP
690686-1 TE Connectivity (690686-1) CRIMPER BOLT SPECIAL
690686-3 TE Connectivity (690686-3) CRIMPER, BOLT - SPECIAL
690686-2 TE Connectivity (690686-2) CRIMPER BOLT-SPECIAL
CAT-VCXI TE Connectivity (CAT-VCXI) VCXI BIMETALLIC BOLTED LUGS
CAT-BLMC TE Connectivity (CAT-BLMC) BLMC BOLTED MECHANICAL LUGS

anchor bolts Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
2000 - 37690B

Abstract: ES45T-R Andrew ANTENNA 6,4
Text: 3.0 ANCHOR BOLT REQUIREMENTS 3.1 Typical anchor bolt installation configurations and dimensions are shown in Figure 2. 3.2 Andrew Type 47429A Anchor Bolt Kit includes anchor bolts , alignment plates and , conditions, water table and frost line is required prior to its use for actual fabrication. 11. Anchor bolts , fabrication. 11. Anchor bolts to be tightened 1/6 of a turn after using snug tightening as defined by the AISC , method. 12. Both top and bottom alignment plates are needed to hold bolts to correct dimensions. Base


Original
PDF 37690B ES45T-T ES45T-R 37690B Andrew ANTENNA 6,4
2005 - ASTM A36

Abstract: 37690B ES45T-R ES45T-T satellite Andrew ANTENNA
Text: 3.0 ANCHOR BOLT REQUIREMENTS 3.1 Typical anchor bolt installation configurations and dimensions are shown in Figure 2. 3.2 Andrew Type 47429A Anchor Bolt Kit includes anchor bolts , alignment plates and , conditions, water table and frost line is required prior to its use for actual fabrication. 11. Anchor bolts , fabrication. 11. Anchor bolts to be tightened 1/6 of a turn after using snug tightening as defined by the AISC , method. 12. Both top and bottom alignment plates are needed to hold bolts to correct dimensions. Base


Original
PDF 37690B ES45T-T ES45T-R ASTM A36 37690B satellite Andrew ANTENNA
TOGGLE CLIP

Abstract: anchor bolts "Toggle Switch" AMP50 SO-215 toggle switch 250V Single Pole toggle Switch TS1001 46way TO608
Text: TURNED ANCHOR BOLTS AS PER SPECIFICATIONS,1 DRAWING OR SAMPLE M-6 x 23 mm. LONG M-8*28mm M-10x33 & M , PRECISION COLD FORGED SCREWS I BOLTS FROM 2 VM TO 8 MM THREADS AS PER INn. STANDARD & SPECIAL TYPE PRECISION


OCR Scan
PDF 2-AMP250V 10-AMP250V TS-1001 SHT-360/ SC-1205/10/ 60-AMP S0-260/360 SO-215 15-AMP TS-1501 TOGGLE CLIP anchor bolts "Toggle Switch" AMP50 toggle switch 250V Single Pole toggle Switch TS1001 46way TO608
2008 - 170H3027

Abstract: HILTI M16 bolt 6vf11 battery hawker 6vf11 UN2794 KS-23997 FAT100 anchor bolts 847135688 J85504D-1 KS-24194
Text: Ordering Information Battery Stand Batteries Options Kits and Thermal Probe Hardware Anchor Bolts and , Information 3 - 3 Supplemental Battery Stand J85504D-1 Lists 16, 17, and 18 Anchor Bolts and Washer , unpacking and handling equipment and tools are available. Anchoring · Anchor bolts for mounting , reinforcing bars occurs during installation of the battery stand. · Anchor bolts are provided in kit , required to properly anchor the battery stand (4 each - anchor bolts and washer plates). · When


Original
PDF J85504D-1 T-83280-30. 170H3027 HILTI M16 bolt 6vf11 battery hawker 6vf11 UN2794 KS-23997 FAT100 anchor bolts 847135688 KS-24194
Not Available

Abstract: No abstract text available
Text: Mounting base 1 Concrete anchor bolts 4 End cap 1 M6 flat washers 2 Retainer springs 2 M8 insertion nuts 6 M8 x 20 mm hex bolts 6 M6 insertion nuts 2 M6 x 10 mm hex bolts 2 M8 flat washers ■6 Installation instructions 1 Model Number


Original
PDF DAR-CB90-Y
Andrew towers M46

Abstract: Andrew M46 m46 andrew tower s42 andrew tower Andrew LIGHT MEDIUM tower m36 andrew tower Communications tower Andrew towers Andrew towers M36
Text: foundation settlement or wind-induced tower translation ensuring perfect, stress-free tower alignment. Anchor bolts are not necessary. A fixed base is available for special applications. Reduced Guy Vibration. Flexible anchor shafts have a dampening effect on wind-induced guy vibrations. The shafts are galvanized , ) intervals. Step bolts are provided on one leg of each M36, but a ladder mounted on the outside may be , characteristics of all steel used for its towers. Andrew guyed towers use flexible anchor shafts to dam pen guy


OCR Scan
PDF 36-inch 46-inch Andrew towers M46 Andrew M46 m46 andrew tower s42 andrew tower Andrew LIGHT MEDIUM tower m36 andrew tower Communications tower Andrew towers Andrew towers M36
1998 - ED83127-30

Abstract: BDFB ED83127 ED83127 fuse panel lineage 2000 BDFB FUSES power distribution frame KS21320 J85568D-1 blown fuse indicator with alarm h569-429
Text: -inch self-drill anchor bolts Protective back covers 150-, 300-, or 600-ampere monitoring shunts Frame alarm , -A: H569-407 Anchor Bolt Ordering Information 5 - 2 Table 5-B: Recommended Double Hole Terminal Lugs for


Original
PDF J85568D-1 J85568D-1 ED83127-30 BDFB ED83127 ED83127 fuse panel lineage 2000 BDFB FUSES power distribution frame KS21320 blown fuse indicator with alarm h569-429
2008 - schematic symbol circuit breaker panel

Abstract: J85568C-1 BDFB J85568C-1 KS-5482 ED83127-30 j85568 J85568E1 WP-91412 l74 ED83127 terminal lugs
Text: dies 3/4-inch drill to bore holes for floor anchors (List A only) Anchor bolts (List A only) 22-26 , , including flat blade screwdriver, socket and torque wrenches for 1/4-inch and 3/8-inch bolts , and a , 6 January 2008 J85568E-1 Secondary DC Mini-Distribution Bay Hold Down Plate Floor Anchor Bolt Framework Base Hold Down Washer Floor Covering Note: Use 3/4 Inch Drill for Floor Anchor Bolts . The Required Minimum Drill Depth is 4 Inches. Figure 5-1: Typical Floor Mounting Detail 1


Original
PDF J85568E-1 J85568E-1 schematic symbol circuit breaker panel J85568C-1 BDFB J85568C-1 KS-5482 ED83127-30 j85568 J85568E1 WP-91412 l74 ED83127 terminal lugs
BOOSTER REGULATOR SERIES VBA

Abstract: smc air filter regulator VBA1311 VBA4100-04 VBA2100-03 VBA200 VBA4100 G27-10-R1 VBAT10 G27-10-R1-X209
Text: mount the air tank on a floor surface, use the four holes to secure the tank with bolts or anchor bolts , bolts (VBA1: M5; VBA2, 4: M10) and tighten them to the specified torque (VBA1: 3Nm; VBA2, 4: 24Nm).


Original
PDF VBA1110 VBA1110 VBA200 VBA400 VBA1111 BOOSTER REGULATOR SERIES VBA smc air filter regulator VBA1311 VBA4100-04 VBA2100-03 VBA200 VBA4100 G27-10-R1 VBAT10 G27-10-R1-X209
2008 - NE030DC48A

Abstract: CC848817635 KS22012 NE075DC24A NE050AC48A CC848756916 ES771A CC848815341 CC109141966 NE030DC48
Text: (ES771A to ES771A or controller) Frame Anchor Bolts and Ground Cable (4) 12mm Cap Bolt Floor Anchor 32


Original
PDF 24/-48V H5692448 CC848820201-MAN NE030DC48A CC848817635 KS22012 NE075DC24A NE050AC48A CC848756916 ES771A CC848815341 CC109141966 NE030DC48
2008 - tpl-b fuse block

Abstract: CC848756916 CC848756924 ES771A unigy 108993531 anchor bolts 847135688 CC408574420 CC848802595 CC109126728
Text: or controller) Frame Anchor Bolts and Ground Cable (4) 12mm Cap Bolt Floor Anchor 32 ft long green


Original
PDF CPS6000-M2 H5694720 GR1089, CPS6000-M2 tpl-b fuse block CC848756916 CC848756924 ES771A unigy 108993531 anchor bolts 847135688 CC408574420 CC848802595 CC109126728
2002 - Deka 95-33

Abstract: UN2800 AVR95-33 Battery charger 48 volt forklift AVR95 AVR95-17 AVR95-31 Deka 95-17 forklift battery charger circuit AVR95-25
Text: local building codes for anchor bolt requirements, anchor bolts not included.) Fig. 4-3 4 , lock in place. (No rear bolts required) (See Fig. 3-2, pg. 10.) 1. Cells should be stored indoors , direction of the post bolts is important! (Refer to Fig. 4-1 and 4-2, pg.11; Fig. 4-3, pg. 4. For proper , tabs and will free itself from the remaining stack.) (See Fig. 3-2, pg. 10.) 4. Using the bolts


Original
PDF AVR95 FDS02-001CTG Deka 95-33 UN2800 AVR95-33 Battery charger 48 volt forklift AVR95-17 AVR95-31 Deka 95-17 forklift battery charger circuit AVR95-25
2006 - 7c471

Abstract: westinghouse MCP *7C471 CROUSE-HINDS ECD bus duct UL857 Cutler-Hammer contactor westinghouse breaker dry transformers 15 KVA nema 4x stainless steel bus bracing
Text: -inch diameter bolts . Anchor bolts and mounting pads will be the responsibility of the user. Maximum , top the body by multiple lead thread bolts to promote quick opening and closing of the enclosure. Cover bolts shall be hex head stainless steel without screwdriver slots, to promote the use of a , bolts are free of the body when the cover is being opened. The cover flange ground joint shall have , , bolts and hardware shall be stainless steel. The external circuit breaker operating handle affixed


Original
PDF SYS19: CRMAIN06-0467-2 7C-467 66008com CRMAIN06-0468-1 7C-468 7c471 westinghouse MCP *7C471 CROUSE-HINDS ECD bus duct UL857 Cutler-Hammer contactor westinghouse breaker dry transformers 15 KVA nema 4x stainless steel bus bracing
2008 - Asbestos MSDS

Abstract: 010-160-300 J85504A earthquake Detection systems ED83 wall putty anchor flange L146 j85504a-1 28064-14-4
Text: Leak Repair Kit and one Supplemental Replenishment Kit for ever 10 anchor bolts (See ED , only the coating and thickener for sealing anchor holes and earthquake bracing. Order one complete , steel carriage bolts , nuts and flat washers High Strength Novolac Epoxy Coating (optional) Flexible , . 4. 4 inch roller with extension Spare 4 inch roll Mixing tray 1/4 inch bolts and assorted , stand location as shown in Figure 4.1 and lightly bolt the pieces together using carriage bolts


Original
PDF WP-93377 Asbestos MSDS 010-160-300 J85504A earthquake Detection systems ED83 wall putty anchor flange L146 j85504a-1 28064-14-4
2000 - KS-15544 L508

Abstract: wp-93936 KS-15544 IEEE-450 14.4 v drill battery charger ks 15544 ks20472 ks 15544 reference values "lead acid" battery monitor LUCENT LINEAGE ks20472
Text: seismic integrity (for Seismic series) racks must be securely anchored to the floor. Install anchor bolts , . Note: Anchor bolts are not provided by Lucent Technologies but are the responsibility of the installer , Assembly 6-6 Figure 6-5: Rack Assembly Location and Anchor Bolt Pattern 6 - 14 Figure 6-6 , , bolts , and washers), shipping plug, vent assemblies, and instruction manual *The racks listed above , bolts must be tightened to specified torque values. Floor loading must be considered in the planning


Original
PDF WP-93936 KS-15544 L508 wp-93936 KS-15544 IEEE-450 14.4 v drill battery charger ks 15544 ks20472 ks 15544 reference values "lead acid" battery monitor LUCENT LINEAGE ks20472
1999 - auto cut off schematic diagram 48v battery charge

Abstract: j85501a-2 mcs controller thyristor battery charger 24v 100a schematic drawing sd83102-03 LUCENT LINEAGE Battery charger 48 volt forklift forklift battery charger circuit sd-82588-02 LUCENT LINEAGE 2000 FLUKE 8060a manual
Text: Rectifier Locate and Anchor the Rectifier AC Power Cables DC Power Cables Supplemental Central Office


Original
PDF 400-Ampere, 50-Hertz J85603C-2 auto cut off schematic diagram 48v battery charge j85501a-2 mcs controller thyristor battery charger 24v 100a schematic drawing sd83102-03 LUCENT LINEAGE Battery charger 48 volt forklift forklift battery charger circuit sd-82588-02 LUCENT LINEAGE 2000 FLUKE 8060a manual
2008 - HILTI M16 bolt

Abstract: yg 2025 2H FIRE DOOR 12IR125 2VR375E Fluke 99B ES682 ED83135-30 ED-83123-30G11 SW201
Text: Components for Frames Circuit Breakers, Fuse Holder, and Fuses Anchor Bolts Terminal Lugs Upgrade Kits , Table 2-J: Circuit Breakers, Fuse Holder, and Fuses 2 - 11 Table 2-K: Anchor Bolts 2 - 12 , Wireless Applications H569-424 Anchor Bolts Table 2-K: Anchor Bolts Seismic H569-424 Anchor Type , wrench: 1/2" deep socket wrenches: 1/2", 15/16" ­ 19 mm for zones 2, 3 anchor kit ­ 3/4" for zone 0, 1 anchor kit ­ 30mm for zone 4 anchor kit Allen wrenches: 3/16", 5 mm torque wrenches (refer to Table 4


Original
PDF H569-424 HILTI M16 bolt yg 2025 2H FIRE DOOR 12IR125 2VR375E Fluke 99B ES682 ED83135-30 ED-83123-30G11 SW201
2000 - HILTI M16 bolt

Abstract: KS23616 ES661B Lucent Lucent 12IR125 12IR125 ES682 DIAGRAM FOR GAS processing plant KS-23616 thermal fuses color coding for 10A ed83135
Text: Components for Frames Circuit Breakers, Fuse Holder, and Fuses Anchor Bolts Terminal Lugs Upgrade Kits , Holder, and Fuses 2 - 11 Table 2-K: Anchor Bolts 2 - 12 Table 2-L: Terminal Lug Kits for , Applications H569-424 Anchor Bolts Table 2-K: Anchor Bolts Seismic H569-424 Anchor Type Comcode Hole , ", 7/16" drive socket wrench: 1/2" deep socket wrenches: 1/2", 15/16" ­ 19 mm for zones 2, 3 anchor kit ­ 3/4" for zone 0, 1 anchor kit ­ 30mm for zone 4 anchor kit Allen wrenches: 3/16", 5 mm


Original
PDF H569-424 HILTI M16 bolt KS23616 ES661B Lucent Lucent 12IR125 12IR125 ES682 DIAGRAM FOR GAS processing plant KS-23616 thermal fuses color coding for 10A ed83135
1996 - Bus Bar torque for metric bolts

Abstract: Bus Bar torque value table for metric bolts torque settings for metric bolts Galaxy Power 4824 power system wye to delta wiring diagram with timer ed83143-30 04-900199 Modutec power module 48 volt rectifier circuit diagram torque settings for metric bolts din 8.8 84772
Text: . Comcodes are available for miscellaneous hardware such as terminal lugs, anchor bolts , and mounting , Information Documentation GPS 4824 Ordering Guide Replacement Parts Cabinet Anchor Kits Plug-In Circuit , 3-2: GPS 4824 Replacement Parts 3-2 Table 3-3: Recommended Concrete Anchor Kits 3-4 Table , single or two hole terminal lugs and M10 x 25 mm bolts . The negative battery leads connects through a , Lucent Technologies Galaxy Power System 4824 Cabinet Anchor Kits Table 3-3: Recommended Concrete


Original
PDF
1999 - auto cut off schematic diagram 48v battery charge

Abstract: thyristor battery charger 24v 100a LUCENT LINEAGE J85503B-2 J85503C3 L3 J85503C rectifier j85501a-2 mcs controller LUCENT LINEAGE 2000 J85503C3 J85503B2
Text: Installation Unpacking Installing or Adding a Rectifier Locate and Anchor the Rectifier AC Power Cables DC


Original
PDF 200-Ampere, 60-Hertz J85503B-2 auto cut off schematic diagram 48v battery charge thyristor battery charger 24v 100a LUCENT LINEAGE J85503B-2 J85503C3 L3 J85503C rectifier j85501a-2 mcs controller LUCENT LINEAGE 2000 J85503C3 J85503B2
2014 - Not Available

Abstract: No abstract text available
Text: required nuts and bolts Package Includes Four concrete inserts, four bolts , four fender washers , concrete inserts, four bolts and four fender washers. Technical Notes: We recommend using a 1/2" concrete drill. Hole must be 4.5" to 4.75" deep. Mark the hole, drill the hole, then tap the anchor into the hole. Thread the bolt into the anchor a few threads only. Tap the bolt with a hammer (with anchor attached , Includes four concrete inserts, four bolts and four fender washers Specifications OVERVIEW Model Type


Original
PDF
ECS Inc LABEL DATE CODE

Abstract: H285224 lexan 161 R 111 847865425 tpl-b fuse block 596B4 J85500G 596B5 EMPRO J85500A-2
Text: A FRAMEWORK, ANCHOR BOLTS , FRAME GROUND HARDWARE AND BASE COVERS, IS RECOMMENDED FOR THIS , POSITIVE FOR 48V SHELF (SEE NOTE 60) (3/8 BOLTS ON I" CENTERS) LIFT INSULATOR FLAP TO ACCESS DC OUTPUT BUS POSITIVE FOR 24V SHELF NEGATIVE FOR 48V SHELF (SEE NOTE 60) (3/8 BOLTS ON I" CENTERS) O a*z«aevira d


OCR Scan
PDF 596A2 ECS6U/12U, T-83493-30 596B4 T-83493-3EMBLIES J85702H-1 ECS Inc LABEL DATE CODE H285224 lexan 161 R 111 847865425 tpl-b fuse block J85500G 596B5 EMPRO J85500A-2
Cutler-Hammer

Abstract: NH3 GL-GG TYCO 596A RECTIFIER THHN 6 str green KS-20472 LS CIRCUIT BREAKERS kic 125 hot air gun fan controller circuit G488 N 847568920
Text: Anchor Bolts (REFERENCE DKAWING H569-4UO COMCOOE DESCRIPITON SEISMIC ZONES 8471357)2 (4) 3/8 SELF , GROUNDING DIAGRAMS. 5. SELF-DRILL AND DROP-IN ANCHOR BOLT KITS CONTAIN 4 EACH OF BOLTS . HOLD-DOWN WASHERS. THREADED STUDS. INSULATED BUSHINGS. NUTS. AND FLAT WASHERS. 6. CAP ANCHOR BOLT KITS CONTAIN 4 EACH OF , 847135662 (4) 1/2 CROP IN (NOTE 5) 0.1.2 847135688 (4) 12mm CAP BOLTS (NOTE 6) 0.1.2.3.4 847135670 (4 , BOLTS ON i inch centers. 2. IF SUPPLEMENTAL BAYS WILL BE INSTALLED ON BOTH SIDES OF THE INITIAL BAY


OCR Scan
PDF 208/240V h569-434 65kic) KS24I94 GPS4848/I00 Cutler-Hammer NH3 GL-GG TYCO 596A RECTIFIER THHN 6 str green KS-20472 LS CIRCUIT BREAKERS kic 125 hot air gun fan controller circuit G488 N 847568920
2008 - NE843

Abstract: outside plant access cabinet laptop repairing guide anchor bolts NE050AC48 LVBD Airpax free computer hardware repairing notes NE030DC48 troubleshooting and repair lcd monitors
Text: : · 7/16" and 9/16" for load and battery connections; · 19 mm for anchor bolts ; Issue 2.0, June 3 , Seismic Zone of the site. We sell a floor anchor kit (847135688) with 4 Hilti 12mm Cap bolts that may be , . 21 Anchor the Frame , equipment. Installation Sequence 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Anchor the Frame Ground the , protection 22 Infinity D Power System Installation Guide: -48V Plants H2007001 Anchor the Frame


Original
PDF H2007001 CC848853515 H2007001 NE843 outside plant access cabinet laptop repairing guide anchor bolts NE050AC48 LVBD Airpax free computer hardware repairing notes NE030DC48 troubleshooting and repair lcd monitors
2011 - switchgear

Abstract: No abstract text available
Text: No file text available


Original
PDF CA08104001E 00-Inch switchgear
Supplyframe Tracking Pixel