The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
LTC1923EGN#PBF Linear Technology LTC1923 - High Efficiency Thermoelectric Cooler Controller; Package: SSOP; Pins: 28; Temperature Range: -40°C to 85°C
LTC1923EGN#TRPBF Linear Technology LTC1923 - High Efficiency Thermoelectric Cooler Controller; Package: SSOP; Pins: 28; Temperature Range: -40°C to 85°C
LTC1923EGN Linear Technology LTC1923 - High Efficiency Thermoelectric Cooler Controller; Package: SSOP; Pins: 28; Temperature Range: -40°C to 85°C
LTC1923EGN#TR Linear Technology LTC1923 - High Efficiency Thermoelectric Cooler Controller; Package: SSOP; Pins: 28; Temperature Range: -40°C to 85°C
LTC1923EUH#TR Linear Technology LTC1923 - High Efficiency Thermoelectric Cooler Controller; Package: QFN; Pins: 32; Temperature Range: -40°C to 85°C
LTC1923EUH#TRPBF Linear Technology LTC1923 - High Efficiency Thermoelectric Cooler Controller; Package: QFN; Pins: 32; Temperature Range: -40°C to 85°C

air cooler Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
fopf

Abstract: ML-7003 x-ray tube operation triode 3kw machlett x-ray tube air cooler x-ray tube xray tube machlett ml-892 Raytheon Company
Text: . Provisions must be made for the anode air cooler fins to clear the tube support. The inside diameters of the , variations from tube to tube in the dimensions of the anode air cooler . The anode connection should be made , air cooler by flexible wires located under the shock ring. MAXIMUM RATINGS AND TYPICAL OPERATING , capacitance is small. The cathode is a unipo-tential oxide-coated type. When cooled by forced air , the anode is capable of dissipating 3 kW with 200 cfm air flow. The internal structure of the ML-7003A has


OCR Scan
PDF ML-7003A ML-7003A ML-7003. ED-15827 fopf ML-7003 x-ray tube operation triode 3kw machlett x-ray tube air cooler x-ray tube xray tube machlett ml-892 Raytheon Company
2013 - DN16NW

Abstract: No abstract text available
Text: (optional) J Active gauge cable K K Air cooler G H EXT75DX turbopump F G E Power supply J A C B E Basic TIC system D A TIC, 200W F Air cooler B , air cooler M E P R T L Relay box D Q Mains cable C M RV pump R , to a turbopump it can control a backing pump, a vent valve, an air cooler and an Edwards active , (water at 15 °C, ambient temp at 40 °C) Forced air cooled, 35 °C ambient 2 × 10 -2 mbar 1 × 10


Original
PDF EXT75DX B72241895, DN16NW
2006 - 2PS0600R12KS4-2G

Abstract: four quadrant chopper driver circuit calculation of IGBT snubber B32654-S0474 600V 300A igbt dc to dc boost converter 62 TO 3GH IGBT FZ 400 KS4 INFINEON HEATSINKS IGBT Power Module PD100
Text: 6.1.3 6.1.4 Technical drawings PrimeSTACK with air cooler PrimeSTACK with water cooler PrimeSTACK , (water cooler ) Meaning of the options indicated with "J" Standard cooler for forced air cooling, fan is , cooler and that of an air cooler : · Air cooler : The trip level at TNTC = 80.85°C · Water cooler The , : o Heatsink with forced air cooling (standard) o Water cooling DC-bus construction. Especially for , interconnection of the individual 62mm modules. Heatsinks (PrimeSTACK Basic add-on) generally either air cooling


Original
PDF
AM MODULATOR

Abstract: Raytheon Company industrial tube company machlett 6423 air cooler 892-R machlett ml-892
Text: €”1!£ FILAMENT TERMINALS lf| MAX. DIA ei i¿O.A. GRID TERMINAL 4 g"iXDI4 ANODE AIR COOLER FILAMENT TERMINALS 3 — * — DIA -GRID TERMINAL ANODE AIR COOLER ED-29008/RI DIMENSIONS — ML-6423 DIMENSIONS â , €” ML-6423, ML-6423-F . Air flow on anode ML-6423, minimum for 12.5 kW dissipation . ML-6423-F, minimum for 10 kW dissipation . Maximum incoming air temperature , with Machlett ML-6423 Air Distributor F-17797. +At frequencies up to 15 Mc, normal cabinet ventilation


OCR Scan
PDF ML-6422 ML-6423 ML-6423-F 892-R, 56ERISTICS ML-642 -t305S ML-6422 AM MODULATOR Raytheon Company industrial tube company machlett 6423 air cooler 892-R machlett ml-892
steam CONDENSER

Abstract: condensers 10 mf CONDENSER steam turbine for the condenser air cooler ABB Group "steam condenser" ABB/steam CONDENSER
Text: path A B A B C b a 42 ABB Review 3/1997 Tube bank Air cooler C , bank Air cooler C D Venting duct Condensate baffle plate 1 Steam inlet flow ments. At , / drilling Total ABB Review 3/1997 Shell Support plates Air cooler Beam Hotwell Water box , field Fully assembled CM/H condenser module ­ view inside the water box A B Tube bank Air cooler C 1 Venting duct Steam inlet flow 1 A A B C B C a b ABB Review


Original
PDF
machlett

Abstract: air cooler 6425F ML-6424 ML-6425 st 1689 industrial tube company Raytheon Company 2s008 ML-6425-F
Text: €”- DIMENSIONS — ML-6424 FILAMENT TERMINALS I J MAX. DIA. ANODE AIR COOLER FILAMENT TERMINALS GRID TERMINAL ANODE AIR COOLER ED-2S008/RI DIMENSIONS — ML-6425 DIMENSIONS —ML-6425-F ST-1689 4.5M 5-64 , -6425-F .Forced-air Air flow on anode: ML-6425, minimum for 12.5 kW dissipation , cfm Maximum incoming air temperature , -6425-F .50 lbs. •When used with Machlett ML-6425 Air Distributor F-17797. +At frequencies up to 15 Mc


OCR Scan
PDF ML-6424 ML-6425 ML-6425. ML-6425-F -I30S3/RZ ML-6424 ML-6425-F 5I82/R4, machlett air cooler 6425F st 1689 industrial tube company Raytheon Company 2s008
ML-7715

Abstract: air cooler 7715 Raytheon Company
Text: .003 DIA ANODE AIR COOLER ALL DIMENSIONS IN INCHES DIMENSIONS —ML-7715 THE MACHLETT LABORATORIES , forced-air or dielectric gas. When cooled by forced air the anode is capable of dissipating 3 kW with 150 cfm air How. The maximum ratings uf 65 kVdc and 70 kv peak apply when the tubes are coin pletely immersed , -7002 Circulating oilt Type of Cooling — ML-7715 Forced-airt Air flow on anode, minimum for 3 kW dissipation I 50 cfm at 0.3" water Air How on grid 50 cfm Maximum incoming air temperature 65 °C Maximum Glass


OCR Scan
PDF ML-7002 ML-7715 ML-7002 ML-7715 air cooler 7715 Raytheon Company
ML-6544

Abstract: machlett 6544 Machlett radar tube 6544 machlett 60 Raytheon Company air cooler machlett triode st1580
Text: HEATER CATHODE ANODE AIR COOLER ED-29003/RI DIMENSIONS FOR OUTLINE OF ML-6544 Ref. Inches Notes , with an air flow of 80 cfm. GENERAL CHARACTERISTICS Electrical Filament Voltage , Air flow on anode (at 45°C and 14.7 psi ambient atmospheric pressure) .80 cfm , .0.2 Air flow on grid radiator, cfm Maximum incoming air temperature


OCR Scan
PDF ML-6544 ED-29016: ML-6544 ED-29003/RI ST-1580 machlett 6544 Machlett radar tube 6544 machlett 60 Raytheon Company air cooler machlett triode st1580
ST-1706

Abstract: ML-7007
Text: 6040 ML-7007 PAGE 5 ML-7007 PAGE 6 COOLING CHARACTERISTICS—ML-7007 ANODE AIR COOLER - «37  , high heat dissipation capability. The anode is rated for 12 kW dissipation with an air flow of 550 cfm , .Forced-air Air flow on anode, minimum for 10 kW dissipation .350 cfm at 3" water Air flow on seals, approximate .100 cfmt Maximum incoming air temperature


OCR Scan
PDF ML-7007 ML-7007 ST-1706
WL23791

Abstract: WL-23791 high power Triode for induction heating WESTINGHOUSE ELECTRIC oscillator westinghouse oscillator WESTINGHOUSE ELECTRIC high power rf amplifir vacuum tube amplifier WL23791/TH150 TUBE AMPLIFIR
Text: of 50%. AIR COOLER CHARACTERISTICS Ampere .22. Ampilficatlon Factor Max. inlet AirFihFi()Gd , e.Aprs o.C. O~ Voltage .- 0 m . to she gid r.t. circuit. The anode cooling air mee me. otAmprst , poree Alr. Saeplgutn Meelmum Incomingn AIr Tomperature . deeC Culb end Seals. . AIrflow throuah , i paalelD.C. Grid Voltage . .-looo max. musb symeriall 2 max. Amperes circit.Theande coing air , Pounds Shipping Weight (Approx.i . Cooling: Forced Air , See Figure0 1 . Anode Maximum incoming Alr


Original
PDF NL-23791/TH xed15 12WdThic WL-23791 WL23791 WL-23791 high power Triode for induction heating WESTINGHOUSE ELECTRIC oscillator westinghouse oscillator WESTINGHOUSE ELECTRIC high power rf amplifir vacuum tube amplifier WL23791/TH150 TUBE AMPLIFIR
8772 P

Abstract: ML-8772 machlett 8772 ML-8773 radar tube thyratron NATIONAL ELECTRONIC TUBE company Raytheon Company machlett x-ray tube
Text: TERMINAL. ANODE ED-28325-I/R4 ML-8772 FILAMENT TERMINALS- AIR COOLER ED , -8773 .Forced-air Air flow on anode for 35 kW dissipation . Pressure: 1700 cfm at 7.8" water* Exhaust: 1970 cfm at 8.4" water* Maximum incoming air , -8773 . 43 lb •When used with ML-8773 air distributor F-17759. ■(•Auxiliary air flow of 50-100 cfm , °C, around the circumference of the seals. At high ambient temperature, additional air flow may be required


OCR Scan
PDF ML-8772 ML-8773 ML-8773 ST-2417 8772 P machlett 8772 radar tube thyratron NATIONAL ELECTRONIC TUBE company Raytheon Company machlett x-ray tube
453gb12e4s

Abstract: SEMIX 71GD12E4S 300gb12e4 igbt cross-reference SKM200GB128D SEMiX 202GB12E4s SEMiX453GB12E4 101GD12E4s IGBT cross reference semikron 303GD12E4-c
Text: (rms) = f (fsw) (Vcc=650V, Vout=400V, fout=50Hz, Ta=40°C, air cooler Rth(s-a)=0.031K/W) Inverter , medium switching frequencies (4.8kHz) and air cooling. The new IGBT 4 technology (~T4/E4) allows for a , maximum continuous inverter current Iout(rms) = f (fsw) (Vcc=650V, Vout=400V, fout=50Hz, Ta=40°C, air cooler Rth(s-a)=0.031K/W) Inverter current with SEMITRANS .126 .128 .12T4 .12E4 280


Original
PDF AN-9001 453gb12e4s SEMIX 71GD12E4S 300gb12e4 igbt cross-reference SKM200GB128D SEMiX 202GB12E4s SEMiX453GB12E4 101GD12E4s IGBT cross reference semikron 303GD12E4-c
machlett ML-6696

Abstract: 6697 ML-6697 machlett thyratron thyratron industrial tube company thyratron tube operation Raytheon Company 4000G machlett
Text: -6697 .Forced-air Air flow on anode for 35 kW dissipation Pressure: 1700 cfm at 7.8" water* Exhaust: 1970 cfm at 8.4" water* Maximum incoming air temperature , -6697 .43 lbs. •When used with ML-6697 air distributor F-17759. tAuxiliary air flow of 50-100 cfm is , the circumference of the seals. At high frequencies or high ambient temperature, additional air flow , CHARACTERISTICS i | ! USING MACHLETT AIR DISTRIBUTOR F-i 17759 ■;[;: | :■: j: i1;:':. I.: i ;: j


OCR Scan
PDF ML-6696 ML-6697 operat18 ML-6697 ST-1707 machlett ML-6696 6697 machlett thyratron thyratron industrial tube company thyratron tube operation Raytheon Company 4000G machlett
ML-6697A

Abstract: Ml-6696a 6697A EC-200 oscillator ml 081 ML6697A a1309 Raytheon Company 6696A ed53
Text: TERMINALS < GRID TERMINAL- h~rrr ANODE AIR COOLER - ® © CD ED-536434 ML-6697A DIMENSIONS FOR , .Forced-air Air flow on anode for 35 kW dissipation . Pressure: 1700 cfm at 7.8" water* Exhaust: 1970 cfm at 8.4" water* Maximum incoming air , .43 lbs. •When used with ML-6697A air distributor F-17759. tAuxiliary air flow of 50-100 cfm is , °C, around the circumference of the seals. At high frequencies or high ambient temperature, additional air


OCR Scan
PDF ML-6696A ML-6697A ED-536434 ML-6697A ST-2373 6697A EC-200 oscillator ml 081 ML6697A a1309 Raytheon Company 6696A ed53
ML-7560

Abstract: ML 7560 machlett ML 1100 dc power Raytheon Company thyratron triode
Text: . ANODE AIR COOLER TUBE SUPPOR_TED_ FROM THIS SURFACE NOTE I : INDEX GROOVE ON ANODE FLANGE MUST ALIGN , -8317 . Forced-air Air flow on anode for 60 kW dissipation, minimum .3000 cfm* * Maximum incoming air temperature .50 °C Air Flow on Insulators and Seals, approximate , volts for peak cathode currents up to 350 amps. * 'When used with ML-8317 air distributor F-27836. *At


OCR Scan
PDF ML-7560 ML-8317 ED-27362/RI 27363/R2 ST-2019 ML 7560 machlett ML 1100 dc power Raytheon Company thyratron triode
2001 - 1kva inverter circuit diagram

Abstract: 2kva inverter circuit diagram AIR FLOW DETECTOR FULL REPORT automatic phase changer file 220V Automatic Voltage Regulator schematic 48v to 220v inverter schematic diagram toshiba tosgage 7511 automatic phase changer 24V to 220V inverter schematic diagram X-RAY thickness
Text: Safety valve Flow switch DC power supply unit (+5V, +24V) Cable duct Air cooler Driving control box , Test samples X-ray/shutter warning lamps 1 set (red/green) Piping parts Air filter Strainer Reducing valve (for air ) Reducing valve (for nitrogen) Nitrogen escape valve Nitrogen cylinder Air , switch (for air ) Pressure switch (for nitrogen) Valve stand Interface (for PI/O interface with , can be replaced easily. C-Frame (standard: measuring air gap height 750mm


Original
PDF OSGAGE-7525 EJD-069 OSGAGE-7525. 1kva inverter circuit diagram 2kva inverter circuit diagram AIR FLOW DETECTOR FULL REPORT automatic phase changer file 220V Automatic Voltage Regulator schematic 48v to 220v inverter schematic diagram toshiba tosgage 7511 automatic phase changer 24V to 220V inverter schematic diagram X-RAY thickness
2015 - Schaffner

Abstract: No abstract text available
Text: Interior air cooling system SK3305.xxx The interior air cooler mounted in the door is an active cooling , sealed. Fig. 11: Connection option for condensate drain at the interior air cooler Seal cabinet , collection tray with drain tube Interior air cooling system SK3305.xxx System messages via LED display â , : Drain duct at the cabinet bottom Fig. 11: Connection option for condensate drain at the interior air cooler Fig. 12: Dimensional drawings ECOsine® active-030/050-480-3 Fig. 13: Drilling template ECOsineÂ


Original
PDF
2011 - Induction sealing machine circuit diagram

Abstract: Leroy Somer Blue Relay TERESSO 56
Text: ) Description of AIR / WATER SINGLE TUBE EXCHANGER 2.7.1 Water Cooler operating condition a) Water Cooler , resistor b) Stator winding temperature sensor c) Stator air sensor d) Stator vibration sensor 2.2 , the RD-thrust pads ; bearing type E.A 2.7 COOLER 2.7.0 Description of the cooler a) General , the water cooler a) General points 2.7.3 Maintenance of the water-cooler a) General points b) Cleaning c) Leak detection for a double-tube exchanger 2.7.4 Servicing the water-cooler a) Cooler


Original
PDF
Not Available

Abstract: No abstract text available
Text: Units °C °C m % g hrs Conditions Air temperature surrounding cooler Air temperature surrounding cooler Above sea level Non-condensing SynJet with heat sink L10 @ 60°C RoHS, UL, FCC Part 15 , PRODUCT DATASHEET SynJet® Spotlight Cooler 34W SynJet cooling technology provides the most reliable thermal management solution available. This LED cooler has been developed by Nuventix for , adjusting settings. Thermal resistance values are given as reference only and are measured in free air


Original
PDF HSLCS-CALBL-001 HSLCS-CALBL-002 HSLCS-CALBL-003 HSLCS-CALBL-006 HSLCS-CALBL-008 HSLCS-CALBL-018 WALLS-C4150-001 WALLS-C4600-001 MKTG-DOC-00114
ISO-7779

Abstract: 7779 cooler Nuventix
Text: bottom middle of the heat sink to ambient air measured at the inlet to the SynJet. 3 SynJet Cooler is , SynJet® Low Profile Cooler SynJet cooling technology provides the most reliable thermal management solution available. This LED cooler has been developed by Nuventix, for low profile cooling up to 19W of , 2.4 2.9 4.1 Parameter Low Profile ­ High Performance, 19W Cooler Low Profile ­ Standard, 15W Cooler Low Profile ­ Silent, 10W Cooler Parameter ­ All Modules Voltage6 Min 4.75 Typ Max


Original
PDF SSCCS-CM005-008 SSCCS-CM005-001 SSCCS-CM005-010 HSCCS-CALCL-001 ISO-7779 7779 cooler Nuventix
cooler TO-220

Abstract: No abstract text available
Text: Regulatory Compliance Min -40 -50 5 Conditions Air temperature surrounding cooler Air temperature , PRODUCT DATASHEET SynJet® LED Cooler L100-180 SynJet cooling provides the most reliable thermal management solution available. This LED cooler has been developed by Nuventix for cooling high , only and are measured in free air without airflow obstructions. Thermal resistance is measured from the bottom middle of the heat sink to ambient air measured at the inlet to the SynJet, with a heat source at


Original
PDF L100-180 NX302106 NX302107 NX302108 NX302109 NX302110 NX302111 NX302112 NX302120 NX302121 cooler TO-220
Not Available

Abstract: No abstract text available
Text: Regulatory Compliance Min -40 -50 5 Conditions Air temperature surrounding cooler Air temperature , PRODUCT DATASHEET SynJet® LED Cooler L100-180 SynJet cooling provides the most reliable thermal management solution available. This LED cooler has been developed by Nuventix for cooling high , are measured in free air without airflow obstructions. Thermal resistance is measured from the bottom 2 middle of the heat sink to ambient air measured at the inlet to the SynJet, with a heat source at


Original
PDF L100-180 NX302106 NX302107 NX302108 NX302109 NX302110 NX302111 NX302112 NX302120 NX302121
Not Available

Abstract: No abstract text available
Text: 15K 95 280 100K Units °C °C m % g hrs Conditions Air temperature surrounding cooler Air temperature surrounding cooler Above sea level Non-condensing SynJet with heat sink L10 @ 60 , PRODUCT DATASHEET SynJet® Spotlight Cooler 31W SynJet cooling technology provides the most reliable thermal management solution available. This LED cooler has been developed by Nuventix for , are measured in free air without airflow obstructions. Thermal resistance is measured from the bottom


Original
PDF LZ-040 MKTG-DOC-00107
Not Available

Abstract: No abstract text available
Text: 15K 95 280 100K Units °C °C m % g hrs Conditions Air temperature surrounding cooler Air temperature surrounding cooler Above sea level Non-condensing SynJet with heat sink L10 @ 60 , PRODUCT DATASHEET SynJet® Spotlight Cooler 31W SynJet cooling technology provides the most reliable thermal management solution available. This LED cooler has been developed by Nuventix for , are measured in free air without airflow obstructions. Thermal resistance is measured from the bottom


Original
PDF LZ-040 MKTG-DOC-00107
Not Available

Abstract: No abstract text available
Text: 15K 95 300 100K Units °C °C m % g hrs Conditions Air temperature surrounding cooler Air temperature surrounding cooler Above sea level Non-condensing SynJet with heat sink L10 @ 60 , PRODUCT DATASHEET SynJet® Spotlight Cooler 34W – Flush Mount SynJet cooling technology provides the most reliable thermal management solution available. This LED cooler has been developed by , are measured in free air without airflow obstructions. Thermal resistance is measured from the bottom


Original
PDF 45and HSLCS-CALBL-020 HSLCS-CALBL-021 HSLCS-CALBL-022 HSLCS-CALBL-023 HSLCS-CALBL-024 HSLCS-CALBL-025 HSLCS-CALBL-027 HSLCS-CALBL-028 WALLS-C4150-001
Supplyframe Tracking Pixel