The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
LTC4355CS#TRPBF Linear Technology LTC4355 - Positive High Voltage Ideal Diode-OR with Input Supply and Fuse Monitors; Package: SO; Pins: 16; Temperature Range: 0°C to 70°C
LTC4355IDE#TRPBF Linear Technology LTC4355 - Positive High Voltage Ideal Diode-OR with Input Supply and Fuse Monitors; Package: DFN; Pins: 14; Temperature Range: -40°C to 85°C
LTC4355IMS#PBF Linear Technology LTC4355 - Positive High Voltage Ideal Diode-OR with Input Supply and Fuse Monitors; Package: MSOP; Pins: 16; Temperature Range: -40°C to 85°C
LTC4355IS#PBF Linear Technology LTC4355 - Positive High Voltage Ideal Diode-OR with Input Supply and Fuse Monitors; Package: SO; Pins: 16; Temperature Range: -40°C to 85°C
LTC4355CMS#TRPBF Linear Technology LTC4355 - Positive High Voltage Ideal Diode-OR with Input Supply and Fuse Monitors; Package: MSOP; Pins: 16; Temperature Range: 0°C to 70°C
LTC4355IS#TRPBF Linear Technology LTC4355 - Positive High Voltage Ideal Diode-OR with Input Supply and Fuse Monitors; Package: SO; Pins: 16; Temperature Range: -40°C to 85°C

WESTINGHOUSE ELECTRIC fuse MEDIUM VOLTAGE 100A Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
2003 - WESTINGHOUSE ELECTRIC fuse

Abstract: MV155F1DBX100E A155F2DORO-xxxE MV155F2DCX125E westinghouse transformer 9F62 MV155F1CBX25E westinghouse kV transformer MV155F1CBX20E WESTINGHOUSE ELECTRIC
Text: (Peak Kiloamperes) 40 CIRCUIT VOLTAGE (KV) Recommended Fuse Clips for Medium Voltage Fuses , Bussmann® E-Rated Medium Voltage Fuses MV155 For Transformer and Feeder Protection 15.5 , Physical Size (inches) Length Dia. Clip Center CATALOG SYMBOL: MV155 E-RATED MEDIUM VOLTAGE FUSES , Center Lengths and Barrel Diameters. The new line of Bussmann 15.5 kV medium voltage fuses have , Reliability. All medium voltage fuses are pulsed twice with 90% of their minimum melt I2t to guarantee


Original
PDF MV155 MV155F1CBX5E MV155F1CBX7E MV155F1CBX10E MV155F1CBX15E MV155F1CBX20E MV155F1CBX25E MV155F1CBX30E MV155F1DBX10E MV155F1DBX15E WESTINGHOUSE ELECTRIC fuse MV155F1DBX100E A155F2DORO-xxxE MV155F2DCX125E westinghouse transformer 9F62 MV155F1CBX25E westinghouse kV transformer MV155F1CBX20E WESTINGHOUSE ELECTRIC
WESTINGHOUSE ELECTRIC fuse

Abstract: A055F1D westinghouse transformer WESTINGHOUSE ELECTRIC fuse MEDIUM VOLTAGE 100A bussmann Fuse 40a a055f2doro A055F1 westinghouse kV transformer MV055F1CAX25E MV055F1CAX20E
Text: of the fuse tube provides UV and moisture protection for the fuse , making Bussmann's medium voltage , ) Recommended Fuse Clips for Medium Voltage Fuses Part No. Fuse Clip Dimensions Diameter A B , medium voltage fuses are classified into three categories: Full Range - defined by ANSI as "a fuse , interrupting device in series with the back-up rated fuse . All Bussmann MV series medium voltage fuses are , Bussmann® E-Rated Medium Voltage Fuses MV055 For Transformer and Feeder Protection 5.5 kV


Original
PDF MV055 MV055F1CAX5E MV055F1CAX7E MV055F1CAX10E MV055F1CAX15E MV055F1CAX20E MV055F1CAX25E MV055F1CAX30E MV055F1CAX40E MV055F1CAX50E WESTINGHOUSE ELECTRIC fuse A055F1D westinghouse transformer WESTINGHOUSE ELECTRIC fuse MEDIUM VOLTAGE 100A bussmann Fuse 40a a055f2doro A055F1 westinghouse kV transformer MV055F1CAX25E MV055F1CAX20E
2002 - WESTINGHOUSE ELECTRIC fuse

Abstract: JCU-250E westinghouse transformer A055F1D a055f2doro 9f62 westinghouse kV transformer MV055F1CAX10E WESTINGHOUSE ELECTRIC fuse MEDIUM VOLTAGE 100A MV055F1DAX200E
Text: Symmetrical) 20 15 10 5 0 0 CIRCUIT VOLTAGE (KV) Recommended Fuse Clips for Medium , Bussmann® E-Rated Medium Voltage Fuses MV055 For Transformer and Feeder Protection 5.5 kV , Barrels CATALOG SYMBOL: MV055 E-RATED MEDIUM VOLTAGE FUSES: Meets E requirements per ANSI C37 , Clip Center Lengths and Barrel Diameters. The new line of Bussmann medium voltage fuses have a , medium voltage fuses are pulsed twice with 90% of their minimum melt I2t to guarantee undamaged


Original
PDF MV055 MV055F1CAX5E MV055F1CAX7E MV055F1CAX10E MV055F1CAX15E MV055F1CAX20E MV055F1CAX25E MV055F1CAX30E MV055F1CAX40E MV055F1CAX50E WESTINGHOUSE ELECTRIC fuse JCU-250E westinghouse transformer A055F1D a055f2doro 9f62 westinghouse kV transformer MV055F1CAX10E WESTINGHOUSE ELECTRIC fuse MEDIUM VOLTAGE 100A MV055F1DAX200E
2007 - A550X

Abstract: a055f2doro BUSSMANN C3746 20E POWER FUSE westinghouse kV transformer
Text: VOLTAGE (KV) Recommended Fuse Clips for Medium Voltage Fuses Part Fuse Clip Dimensions No. Diameter A B , E-RATED MEDIUM VOLTAGE 5.5 kV FUSES "E"-Rated Power Fuses Having Full Range Clearing Capability for Medium Voltage Transformer Circuit Protection. Part Number MV055F1CAX5E MV055F1CAX7E , E-RATED MEDIUM VOLTAGE FUSES Meets E-Rating requirements of ANSI C37.46 Meets Full Range requirements of , . Part Number Construction Medium Voltage Example MV Voltage Rating 055 055 = 5.5KV 155 = 15.5KV F


Original
PDF MV055F1CAX5E MV055F1CAX7E MV055F1CAX10E MV055F1CAX15E MV055F1CAX20E MV055F1CAX25E MV055F1CAX30E MV055F1CAX40E MV055F1CAX50E MV055F1CAX65E A550X a055f2doro BUSSMANN C3746 20E POWER FUSE westinghouse kV transformer
2007 - A825X

Abstract: 20E POWER FUSE
Text: E-RATED MEDIUM VOLTAGE 8.25 kV FUSES "E"-Rated Power Fuses Having Full Range or Back-up Clearing Capability for Medium Voltage Transformer Circuit Protection. Part Number 8.25FFNHA20E 8.25FFNHA25E , 8.25FFNH SPECIFICATIONS E-RATED MEDIUM VOLTAGE FUSES Meets E-Rating requirements of ANSI C37.46 Meets Full Range requirements of ANSI C37.40. 8.25BFNH SPECIFICATIONS BACK-UP MEDIUM VOLTAGE FUSES Meets Back-up , MEDIUM VOLTAGE 8.25 kV FUSES "E"-Rated Medium Voltage Fuses for 8.25 FFNHA and 8.25 FFNHK Fuses


Original
PDF 25FFNHA20E 25FFNHA25E 25FFNHA30E 25FFNHA40E 25FFNHA50E 25FFNHA65E 25FFNHA75E 25FFNHK100E 25FFNHK150E 25BFNHA80* A825X 20E POWER FUSE
JCK6R

Abstract: Westinghouse fuses westinghouse ac motor JCL6R JCL-A24R JCL-6R JCL-3R JCK-9R JCL2R westinghouse 12
Text: fuse . · R-Rated medium voltage fuses are back-up current limiting fuses used in conjunction with medium voltage motors and motor controllers. · Current limiting fuses may be designated as R-Rated if , Motor Circuit Protection Medium Voltage Dimensional Data INDICATOR Showing Fuse is Open 0.38 , Bussmann® R-Rated Fuses For Motor Circuit Protection Medium Voltage JCK, JCK-A, JCL, & , for use with medium voltage starters to provide short-circuit protection for the motor and motor


Original
PDF SB98107 JCK6R Westinghouse fuses westinghouse ac motor JCL6R JCL-A24R JCL-6R JCL-3R JCK-9R JCL2R westinghouse 12
OETL-NF30-F

Abstract: OETL-NF60-F Allen-Bradley bulletin 815 type a Cutler-Hammer HFD SDN12 LL66078 westinghouse breaker MCS606R MCS603R UL E64791
Text: * No fuse - 3.88 6.62 - 5.12 9.62 6.44 9.62 DS100 100A * 100A-250V , 100A * 60A-600V J DS200 200A* No fuse - DS200 200A* 200A-250V H, K , 100A No fuse - 4.86 4.78 5.66 8.00 12.53 9.53 12.53 OETL-NF175-F 175A , 100A No fuse - 5.56 8.95 3.00 5.38 9.91 7.47 9.91 C361 SE263 100A , * 7.62 12.12 9.12 12.12 TDOM1A 100A No fuse - 7.75* 5.25 6.18* 7.62


Original
PDF EL-1-71 E64791 SN4242108 LL66078 494V-R1, 1494F 1494D 00A-600V OETL-NF30-F OETL-NF60-F Allen-Bradley bulletin 815 type a Cutler-Hammer HFD SDN12 LL66078 westinghouse breaker MCS606R MCS603R UL E64791
WESTINGHOUSE scr

Abstract: Westinghouse thyristor POW-R-BRIK WESTINGHOUSE scr fast dc to ac inverter by scr
Text: solutions, supporting many markets, including:  AC, DC and Servo Drives (Low and Medium Voltage ) ï , Power Semiconductor Divisions of General Electric Company, Westinghouse Electric Corporation, and Mitsubishi Electric Corporation. In 1994, Westinghouse sold its shares to General Electric and Mitsubishi , Equipment  Medium Voltage Inverters  Motor Controls  Power Supplies  Traction Inverters ï , / region, go to www.pwrx.com/SalesSupport.aspx General Purpose Voltage : 100V to 6500V Current: 100A to


Original
PDF 202/3K/Pub. WESTINGHOUSE scr Westinghouse thyristor POW-R-BRIK WESTINGHOUSE scr fast dc to ac inverter by scr
Westinghouse ampgard

Abstract: JCG-A-24R JCK-B-30 JCK-B-12R JCK-A-24R JCK-A-18R JCK-A-12R JCK-24R Westinghouse Motor JCK-12R
Text: Bussmann® R-Rated Fuses For Motor Circuit Protection Medium Voltage JCK, JCK-A, JCK-B, JCH, JCL, JCL-A, JCL-B, JCG, JCR, & JCR-B · R-Rated medium voltage fuses are back-up current limiting fuses used in conjunction with medium voltage motors and motor controllers. · The JCK-A, JCL-A, & JCR are supplied with Westinghouse Ampguard Hookeye. · This single hookeye is on one end of the fuse and , for use with medium voltage starters to provide short-circuit protection for the motor and motor


Original
PDF SB01396 Westinghouse ampgard JCG-A-24R JCK-B-30 JCK-B-12R JCK-A-24R JCK-A-18R JCK-A-12R JCK-24R Westinghouse Motor JCK-12R
2011 - CA08104001E

Abstract: westinghouse contactor Westinghouse ampgard westinghouse capacitor westinghouse transformer 3750 KVA 9-0-9 step down transformer fusible 65k westinghouse switchgear westinghouse transformer RBA-800
Text: power fuse business began over 75 years ago under Westinghouse ® Electric . In 1935, Westinghouse introduced the medium voltage boric acid expulsion fuse followed by the medium voltage current limiting fuse . Even today, medium voltage fuses continue to use the core Westinghouse technology. Eaton continues to , 09 003 9.0-3 Table 9.0-2. Eaton Medium Voltage Fuse Family Current Limiting HLE: CLE: CLS: HCL , Fuses-Medium Voltage September 2011 Sheet 09 001 9.0-1 Fuses- Medium Voltage Contents


Original
PDF Section200E, 100SE, 125SE, 150SE, 175SE, 200SE CA08100005E CA08104001E CA08104001E westinghouse contactor Westinghouse ampgard westinghouse capacitor westinghouse transformer 3750 KVA 9-0-9 step down transformer fusible 65k westinghouse switchgear westinghouse transformer RBA-800
2011 - 2UDCP

Abstract: TDA 7288 C371H7 WESTINGHOUSE ELECTRIC TDA+7288
Text: , Allen Bradley, Cutler Hammer, General Electric , Siemens I-T-E Max-Flex™, Square D Disconnect , Westinghouse Type C361 disconnect swtches and operator mechanisms, and type C371 circuit breakers and , Electric Type STDA flange handles and variable depth operating mechanisms for disconnect switches and , ABB Controls, Allen Bradley, Cutler Hammer, General Electric , Siemens I-T-E Max-Flex™, Square D , Enclosures - NEMA 12 ABB Controls, Allen Bradley, Cutler Hammer, General Electric , Siemens I-T-E Max-Flexâ


Original
PDF EGP-1-1967 EMP-1-1967 1494F 1494D 9422-C1) 2UDCP TDA 7288 C371H7 WESTINGHOUSE ELECTRIC TDA+7288
2011 - circuit breaker ABB

Abstract: C371H7
Text: , Cutler Hammer, General Electric , Siemens I-T-E Max-Flex™, Square D Disconnect 3UHD Shown , mounted disconnect switches and circuit breaker mechanisms. • C-H Westinghouse type C361 disconnect , . Flex-Shaft™ handle operators for circuit breakers. • General Electric type STDA flange handles and , Duty Disconnect Enclosures - NEMA 12 ABB Controls, Allen Bradley, Cutler Hammer, General Electric , Electric , Siemens I-T-E Max-Flex™, Square D Disconnect Freestanding Enclosures Part No


Original
PDF 1494F 1494D circuit breaker ABB C371H7
2011 - Westinghouse disconnect handles

Abstract: ABB Air Circuit breaker CUTLER HAMMER SIEMENS circuit breakers siemens circuit breaker westinghouse breaker C361H2 1494V SK-1200 CIRCUIT BREAKER siemens
Text: circuit breakers. Use handle for NEMA 4 rating. · General Electric Type STDA flange handles and variable , Electric , Siemens I-T-E Max-FlexTM, Square D Cutout Detail Standards · UL 508 Type 3R, 4 and 4X · , www.hammondmfg.com ABB Controls, Allen Bradley, Cutler Hammer, General Electric , Siemens I-T-E Max-FlexTM, Square D , 1494V-RA2 (except for Hammond part # 1447S46L12, use 1494V-RB2 (2) Trailer fuse block kit (if required): Bulletin 1494V Fuse kit (if required) Line and load connectors (if required) Door Hardware: n/a Circuit


Original
PDF 1447SN4SS 1494F 1494D 494V-R1, Westinghouse disconnect handles ABB Air Circuit breaker CUTLER HAMMER SIEMENS circuit breakers siemens circuit breaker westinghouse breaker C361H2 1494V SK-1200 CIRCUIT BREAKER siemens
2011 - Not Available

Abstract: No abstract text available
Text: , Cutler Hammer, General Electric , Siemens I-T-E Max-Flex™, Square D Disconnect Freestanding , operated disconnect switches and circuit breaker mechanisms. C-H Westinghouse Type C361 disconnect , ShaftTM handle operators for circuit breakers. General Electric Type STDA flange handles and variable , , Cutler Hammer, General Electric , Siemens I-T-E Max-Flex™, Square D Disconnect Freestanding , Modular Disconnect Enclosures - NEMA 12 ABB Controls, Allen Bradley, Cutler Hammer, General Electric


Original
PDF EGP-1-1967 EMP-119r
2013 - westinghouse to Cutler-Hammer cross reference

Abstract: WESTINGHOUSE life line contactor 927566 Cutler-Hammer type m RELAY Cutler-Hammer 9586 westinghouse contactor westinghouse transistor cross reference WESTINGHOUSE scr WESTINGHOUSE motor life line Westinghouse SCR cross reference
Text: Motor Control Motor Control 13 Motor Control Contactors, Starters and Brakes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Adjustable Frequency AC Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Synchronous . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Starters ( Medium Voltage ). . . . . . . . . . . . . . . . . . . . , F contactor was replaced by the DE-ION® contactor, which featured the Westinghouse trademark


Original
PDF V12-T13-2 V12-T13-72 V12-T13-76 V12-T13-87 CA08100014Eâ V12-T13-1 IB48008 IB48009 RP48J01TE RPD8855S westinghouse to Cutler-Hammer cross reference WESTINGHOUSE life line contactor 927566 Cutler-Hammer type m RELAY Cutler-Hammer 9586 westinghouse contactor westinghouse transistor cross reference WESTINGHOUSE scr WESTINGHOUSE motor life line Westinghouse SCR cross reference
2011 - 1447S

Abstract: Allen Bradley Bulletin 709 Westinghouse disconnect handles K7FHD-HS12 C361KJ4 westinghouse breaker SIEMENS circuit breakers KdH2R 1494V-H11 C371H5
Text: Westinghouse C361 flange mounted variable depth operating mechanism with disconnect switches and C371 flange , circuit breakers. · General Electric Type STDA flange handles and variable depth operating mechanism for , . ABB Controls, Allen Bradley, Cutler Hammer, General Electric , Siemens I-T-E Max-FlexTM, Square D , Hammer, General Electric , Siemens I-T-E Max-FlexTM, Square D 1447S Single Door Disconnect Enclosures - , Controls, Allen Bradley, Cutler Hammer, General Electric , Siemens I-T-E Max-FlexTM, Square D Ship Wt. lbs


Original
PDF 1447S 1494F 1494D GeneC371 Allen Bradley Bulletin 709 Westinghouse disconnect handles K7FHD-HS12 C361KJ4 westinghouse breaker SIEMENS circuit breakers KdH2R 1494V-H11 C371H5
2010 - Westinghouse Motor protection relay

Abstract: Westinghouse indicating lights westinghouse power circuit breakers westinghouse relay list UL1203 Westinghouse Motor EBMB series circuit breaker and enclosure westinghouse breaker 800 Square D 800 AMP Breaker westinghouse breaker
Text: General Electric TJJ and TJK frames available 125 through 400 amp. trip. Westinghouse LD frame available , . EBMB Series Enclosures for Circuit Breakers Circuit Breaker Enclosures 3C Poles Voltage , 70A 10A through 70A 15A through 100A 10A through 150A 15A through 100A 10A through 150A 15A through 100A 15A through 150A 70A through 250A 100A through 400A 250A through 600A 300A through 800A , 36 EBMBL WT36 EBMBL WT36 EBMBL DT36 Symbol Cutler-Hammer General Electric Square D


Original
PDF
magnetek century ac motor

Abstract: motor protector klixon siemens 3UN thermistor klixon WESTINGHOUSE dc motor Q63100 p426-m155 P401-M155 X065 thermik S01
Text: Motors (Emerson Electric ) Fans Westinghouse Electric Fans (Through 1980's) IEC Terminal Blocks and , GENERAL PURPOSE DC CONTACTOR MEDIUM VOLTAGE VACUUM CONTACTOR H3 GRID B ANK & VITROHM RESISTOR , PAGES 15-16 SERIES 6 ­ DEEP RECESS PAGES 16-19 SERIES 7 ­ WESTINGHOUSE PAGE 19 SERIES 8 ­ D , . 50 Delco . 50 General Electric . 51-53 Louis , . 56 Teco, US . 57 Westinghouse . 57 MOTOR


Original
PDF 200APORT magnetek century ac motor motor protector klixon siemens 3UN thermistor klixon WESTINGHOUSE dc motor Q63100 p426-m155 P401-M155 X065 thermik S01
Westinghouse thyristor

Abstract: westinghouse DIODES westinghouse thyristor drive WESTINGHOUSE dc motor westinghouse power rectifiers WESTINGHOUSE RECTIFIERS mitsubishi sic MOSFET WESTINGHOUSE ELECTRIC Westinghouse diode SiC IGBT High Power Modules
Text: semiconductor solutions, supporting many markets, including: AC, DC and Servo Drives (Low and Medium Voltage , General Electric Company, Westinghouse Electric Corporation, and Mitsubishi Electric Corporation. In 1994, Westinghouse sold its shares to General Electric and Mitsubishi Electric . General Electric and Mitsubishi Electric currently share equal ownership of Powerex. Powerex offers not only the highest quality , Power ­ ­ ­ ­ ­ Wind Photovoltaic Flywheel Fuel Cell Microturbine Electric Vehicle


Original
PDF
2006 - Westinghouse Motor protection relay

Abstract: westinghouse breaker Square D KAL Breaker UL1203 westinghouse power circuit breakers Cutler-Hammer 225 amp circuit breaker SPACE HEATER EBMBB-TTTEB32 Westinghouse Cutler-Hammer LD
Text: 150 amp. trip. 5 Westinghouse FDB frame available 15 thru 150 amp. trip. 6 General Electric TFJ and , Breakers Circuit Breaker Enclosures Poles 1 Voltage Rating Circuit Breaker Frame Size , 10A thru 70A 15A thru 100A 10A thru 150A3 15A thru 100A 10A thru 150A 15A thru 100A 15A thru 150A 70A thru 250A 100A thru 400A6 250A thru 600A 300A thru 800A 125A thru 800A (max , Frame 600VAC 600VAC 600VAC Circuit Breakers: Manufacturer Cutler-Hammer General Electric Square


Original
PDF SYS19: CRMAIN06-0366-1 3C-366 66008com Westinghouse Motor protection relay westinghouse breaker Square D KAL Breaker UL1203 westinghouse power circuit breakers Cutler-Hammer 225 amp circuit breaker SPACE HEATER EBMBB-TTTEB32 Westinghouse Cutler-Hammer LD
westinghouse power rectifiers

Abstract: WESTINGHOUSE RECTIFIERS 2N2753 Westinghouse Semiconductor WESTINGHOUSE rectifier Westinghouse Power rectifier Westinghouse 54-161 41A hall 2N2740 2N2739
Text: 54-02 other Westinghouse Semiconductor products low power silicon rectifiers technical data medium , 54-967 Westinghouse Electric Corporation Semiconductor Division: Youngwood Plant • Youngwood, Pa , applications 20 amperes • 200 watts collector-to-emitter voltage 50 to 200 volts technical dala 54-661 page 9 wm Westinghouse family of 20-ampere NPN silicon , . maximum ratings JEDEC typ« collector to emitter voltage , Vce. volts collector to base voltage , VCB


OCR Scan
PDF 2N2739-2N2754 20-ampere E/U63/DB; C/448 607/AD westinghouse power rectifiers WESTINGHOUSE RECTIFIERS 2N2753 Westinghouse Semiconductor WESTINGHOUSE rectifier Westinghouse Power rectifier Westinghouse 54-161 41A hall 2N2740 2N2739
2001 - WESTINGHOUSE RECTIFIERS

Abstract: westinghouse DIODES WESTINGHOUSE scr HVCA WESTINGHOUSE BRIDGE RECTIFIERS selenium rectifier westinghouse selenium surge suppressor westinghouse power scr Westinghouse Power rectifier 115 vac SINGLE phase bridge rectifier
Text: stack line formerly owned by Westinghouse /Powerex. This silicon power rectifier line added high voltage , , as well as the General Electric , International Rectifier, Westinghouse and Sarkes-Tarzian (ST-Semicon , of High Voltage Rectifiers, Bridge Rectifiers and special assemblies for particular customer applications. CKE is a supplier of High Voltage Silicon Rectifiers, MOV's, Selenium Suppressors, High Current/High Voltage Assemblies and builds custom assemblies for unique requirements. CKE later began to supply


Original
PDF 5M1000 WESTINGHOUSE RECTIFIERS westinghouse DIODES WESTINGHOUSE scr HVCA WESTINGHOUSE BRIDGE RECTIFIERS selenium rectifier westinghouse selenium surge suppressor westinghouse power scr Westinghouse Power rectifier 115 vac SINGLE phase bridge rectifier
westinghouse breaker

Abstract: ND312T33W Cutler-Hammer Digitrip RMS 310 Westinghouse mcc 2100 Cutler-Hammer Digitrip RMS 310 trip unit Cutler-Hammer Digitrip RMS 310 rating plug 100-A18ND3 Cutler-Hammer hfd 65k Allen-Bradley SMC 150-A135NBD WESTINGHOUSE life line contactor
Text: . 73 DISCONNECTS, FUSE BLOCKS AND FUSE CLIPS FOR BULLETIN 2100 UNITS . 75 DISCONNECTS, FUSE BLOCKS AND FUSE CLIPS FOR BULLETIN 2400 UNITS . 82 SERIES `R' BULLETIN 2100 UNITS PAGE 2 SERIES `D' BULLETIN 2400 UNITS PUBLICATION 2100-6.0.2 - September 1998 LINE AND LOAD FUSE , . 84 ALLEN-BRADLEY TO CUTLER-HAMMER ( WESTINGHOUSE ) BREAKER CROSS-REFERENCE . 85 CIRCUIT , HARDWARE . 101 FUSE BLOCKS


Original
PDF A128502 A483339 A483344 B677442 B67745needing westinghouse breaker ND312T33W Cutler-Hammer Digitrip RMS 310 Westinghouse mcc 2100 Cutler-Hammer Digitrip RMS 310 trip unit Cutler-Hammer Digitrip RMS 310 rating plug 100-A18ND3 Cutler-Hammer hfd 65k Allen-Bradley SMC 150-A135NBD WESTINGHOUSE life line contactor
70-12911-04

Abstract: 70-12911-2 t10812 20k ohm potentiometer T-10812-71 70-12911-4 Westinghouse CO 8 HELICOPTER bell 76301 18K838263
Text: WESTINGHOUSE MACDONALD DETTWEILER ESKA WESTINGHOUSE WESTINGHOUSE WESTINGHOUSE LINCOLN ELECTRIC LINCOLN , CATALOGUE PART CATALOGUE PART WESTINGHOUSE CATALOGUE PART CATALOGUE PART CATALOGUE PART CATALOGUE PART , PART CATALOGUE PART CATALOGUE PART LELAND ELECTRIC BAILEY METER CO. BAILEY METER CO. BAILEY METER CO. BAILEY METER CO. BAILEY METER CO. SPECIAL LELAND ELECTRIC PHAOSTRON CO. PHAOSTRON CO , 16 OHMS HEATH CO. 30 OHMS TERRY PHONES INC 5K OHMS GENERAL ELECTRIC 120 OHMS TELE-SOUND INC


Original
PDF 18C82528 107D176 107D176-24 4088D64 404P513 T-10812-50 T-10812-69 T-10812-71 5SE01904-1 18C82172H01 70-12911-04 70-12911-2 t10812 20k ohm potentiometer T-10812-71 70-12911-4 Westinghouse CO 8 HELICOPTER bell 76301 18K838263
1977 - Westinghouse SCR handbook

Abstract: General electric SCR SCR Applications Handbook General electric SCR manual "General Electric SCR Manual" 6th SCR Handbook, rca INTERNATIONAL RECTIFIER scr WESTINGHOUSE scr rca thyristor manual voltrap
Text: the efforts of Dr. Newell, The Westinghouse Electric Corporation has engaged his friends and , (Series Devices) Medium Power 10 20 200 2k 20k 100 10 0 200k Voltage , electronics with the aid of his associates at the Westinghouse Research and Development Center. Until his , students alike better understand the field of power electronics. As a "teacher" within Westinghouse , as , . Single-Phase Full-Wave Diode Rectifiers and Continuous Current 10. Average Voltage Across an Inductance 11


Original
PDF
Supplyframe Tracking Pixel