The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
LT5554IUH#TRPBF Linear Technology LT5554 - Broadband Ultra Low Distortion 7-Bit Digitally Controlled VGA; Package: QFN; Pins: 32; Temperature Range: -40°C to 85°C
LTC6412IUF#TRPBF Linear Technology LTC6412 - 800MHz, 31dB Range Analog-Controlled VGA; Package: QFN; Pins: 24; Temperature Range: -40°C to 85°C
LTC6412CUF#PBF Linear Technology LTC6412 - 800MHz, 31dB Range Analog-Controlled VGA; Package: QFN; Pins: 24; Temperature Range: 0°C to 70°C
LTC6412IUF#PBF Linear Technology LTC6412 - 800MHz, 31dB Range Analog-Controlled VGA; Package: QFN; Pins: 24; Temperature Range: -40°C to 85°C
LTC6412CUF#TRPBF Linear Technology LTC6412 - 800MHz, 31dB Range Analog-Controlled VGA; Package: QFN; Pins: 24; Temperature Range: 0°C to 70°C
LT5554IUH#PBF Linear Technology LT5554 - Broadband Ultra Low Distortion 7-Bit Digitally Controlled VGA; Package: QFN; Pins: 32; Temperature Range: -40°C to 85°C

Variable Area Rotameter Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
2002 - Not Available

Abstract: No abstract text available
Text: (Scale) Figure 1: Variable area flowmeter, also called a rotameter , has a float that moves up or , VARIABLE AREA FLOWMETERS Flow Reference Section Introduction Variable area flowmeters are , . They operate on the variable area principle, whereby a flowing fluid changes the position of a float , , or vane is used to give a direct visual indication of the flowrate. The variable area family of , operation is based on the variable area principle: fluid flow raises a float in a tapered tube, increasing


Original
PDF
2002 - Not Available

Abstract: No abstract text available
Text: rotameter / variable area meter for a particular application. For general information on these flowmeters , developed so that when a rotameter or variable area meter is used for a different fluid at different , see that rotameters and variable area meters are generally calibrated for water or air operating at , from rotameters and variable area meters is sensitive to the condition of the fluid passing through , realize that the B What about variable area meters? Variable area meters of a piston-and-tapered cone


Original
PDF
2002 - FL1100

Abstract: No abstract text available
Text: VARIABLE AREA FLOWMETERS Flow Reference Section Retaining Ring End Cap Body Flow , Metering Cone Figure 4: Piston-type Variable Area Flowmeter 1 3 5 Magnet/ Piston Assembly A. INLET PORT B. FLAPPER VANE C. OUTLET PORT D D. SPRING D E. ENLARGED AREA TO ALLOW HIGHER , . Piston and Vane Type Variable Area Flowmeters Piston-type flowmeters use an annular orifice formed by , Glass = 2.53 Specific gravity of 316 SS = 8.04 For Gases: SCFM air flow from rotameter reading =


Original
PDF FL-1000, FL-1100, FL-1200, FL-1300, FL-1500, FL-1600, FL-1700, FL-1900 84/spec. FL-2700, FL1100
2002 - Not Available

Abstract: No abstract text available
Text: Shield Both Glass and 316 SS Floats Included The FL-400A Series variable area flowmeters are , -400A shielded high flowrate rotameter , $445. B-29 Omega Engineering


Original
PDF FL-400A FL-400A FL-401A FL-400A/401A
2000 - cross reference capillary rotary compressor

Abstract: ultrasonic flowmeter circuit
Text: Pressure Flowmeters • Primary Element Options • Pitot Tubes • Variable Area Flowmeters Wedge , SCFM—Sm3/hr 3 Variable Area (Rotamater) Vortex Shedding A √ √ 10:1 SD √ A √ √ 12/1  , . Fundamentals of Flow Metering, Technical Data Sheet 3031, Rosemount Inc., 1982. Guide to Variable Area , Options Pitot Tubes Variable Area Flowmeters Differential Pressure Flowmeters he calculation of , pattern in any externally detectable process variable , and, as the fluid travels from point A to point


Original
PDF
2005 - Variable Area Rotameter

Abstract: fmx siemens MASONEILAN VALVE ultrasonic flow meter rtt 10 foxboro foxboro FLOW METER turbine masoneilan MASONEILAN SVI ii Vortex flowmeter panametrics xmt 868
Text: Variable Area Flowmeter UMF Endress + Hauser 0 ES UMC2 Bopp + Reuther Messtechnik , 52 IMT25 Magnetic Flowmeter 1 20 41 H250/M9 Variable Area Flowmeter 1 69 , 70x Radar Level 11 69 249 M10 Variable Area Flowmeter 2 69 234 M8E Variable Area Flowmeter 1 69 230 704 HorizonTM Guided Wave Radar 1 86 231 705 , FLow 1 55 82 DYF Vortex Flow 2 55 11 RAMC Rotameter Flow Meter 1 55


Original
PDF 800xA TB82PH TB82PH-Combined TB82TC-Combined TB82TE-Combined LB491 X3301 3BDD013118 Variable Area Rotameter fmx siemens MASONEILAN VALVE ultrasonic flow meter rtt 10 foxboro foxboro FLOW METER turbine masoneilan MASONEILAN SVI ii Vortex flowmeter panametrics xmt 868
2002 - Not Available

Abstract: No abstract text available
Text: 65 MM AND 150 MM ROTAMETERS Featuring New Design with Easy Tube Replacement and Superior Readability ߜ ±2% Full Scale Accuracy ߜ Non-Rotating Seal Spindle ߜ Easy-to-Read Scale Design ߜ Special Lock Nut Design for Easy Tube Replacement The OMEGA® precision variable of air, water, and gases, with up to ±2% of full scale accuracy and 0.25% of full scale repeatability. These units , rotameter , 16 turn high resolution non-rising stem valve stainless steel unit, with glass float, range of


Original
PDF FL-3845G FL-3845ST FL-3845C FL-3841G FL-3841ST FL-3861SA FL-3861ST FL-3861C FL-3802G
2002 - Not Available

Abstract: No abstract text available
Text: , viscous liquids; some slurries Variable Area Clean, dirty viscous liquids Positive Clean, viscous , cross-sectional area is known and remains constant, the average velocity is an indication of the flow rate. The , liquid flow through the pipe V = average velocity of the flow A = cross-sectional area of the pipe , conditions, the orifice area ratio, and the physical properties of the liquid being measured. Venturi , METERING TUBE 10 R (Scale) Figure 3: Variable-area flowmeter, also called a rotameter , has a


Original
PDF
2005 - 6ES7 321-1BL00-0AA0

Abstract: 322-1BL00-0AA0 6ES7 322-1BL00-0AA0 332-5HD01-0AB0 7UT612 6ES7 332-5hf00-0ab0 6ES7 332-5HD01-0AB0 321-1BL00-0AA0 6ES7 322-1BL00-0AA0 SIEMENS ultrasonic flowmeter circuit
Text: Controller CFW 09 Variable Frequence Drive DP 0x1003 / 1.5 of 2004/03/12 ABB FCM2000 PA , Mass Flowmeter DP 0x08F3 / 3/- Krohne H 250 ESK-3 Rotameter PA 0xF201 / 1.0 of


Original
PDF 800xA 0x09EC 0x05CD F02-PremiTork IQS12 0x0845 0x0824 0x056E AO2000 6ES7 321-1BL00-0AA0 322-1BL00-0AA0 6ES7 322-1BL00-0AA0 332-5HD01-0AB0 7UT612 6ES7 332-5hf00-0ab0 6ES7 332-5HD01-0AB0 321-1BL00-0AA0 6ES7 322-1BL00-0AA0 SIEMENS ultrasonic flowmeter circuit
2000 - FP-512

Abstract: FR30 MB91101 MB91106 MB91191 fcc911
Text: which the results of compilation are output. It also describes the variable area for variables that are initialized at definition and the variable area for those that are not. In addition, the chapter describes variables declared as "static." CHAPTER 3 "READ-ONLY VARIABLE AND THEIR VARIABLE AREA " This chapter , time and provides notes on their use. The chapter also discusses the reduction of the variable area , AUTOMATIC VARIABLES TO REDUCE THE VARIABLE AREA " This chapter explains how to reduce the variable area by


Original
PDF CM71-00324-1E 32-BIT fcc911 fcc911 FP-512 FR30 MB91101 MB91106 MB91191
2000 - Fcc907

Abstract: F2MC-16
Text: initialized at definition and the variable area for those that are not. In addition, the chapter describes variables declared as "static." CHAPTER 3 "READ-ONLY VARIABLES AND THEIR VARIABLE AREA " This chapter , time and provides notes on their use. This chapter also discusses the reduction of the variable area , AUTOMATIC VARIABLES TO REDUCE THE VARIABLE AREA " This chapter explains how to reduce the variable area by , 2.1 External Variables and Their Variable Area


Original
PDF CM42-00327-1E 2MC-16 16-BIT fcc907 F2MC-16L/16LX/16/16H/16F F2MC-16 Fcc907
2000 - ASM 1042

Abstract: MB89PV620
Text: areas for variables that are initialized at definition and the variable area for those that are not. In , VARIABLE AREA " This chapter describes how to use variables declared with the type-qualifier "const" that , reduction of the variable area and object efficiency for referencing when the "const" type modifier is used. CHAPTER 4 "USING AUTOMATIC VARIABLES TO REDUCE THE VARIABLE AREA " This chapter explains how to reduce the variable area by using automatic variables. Area is allocated to automatic variables at execution time


Original
PDF CM25-00320-1E fcc896 fcc896 fcc896. ASM 1042 MB89PV620
1996 - 004C

Abstract: 007B C96F AA119
Text: . C Language Specifications and Run Time 2. Variable Definition and Variable Area 3. Effective Use , when this is done. 2. Variable Definition and Variable Area This section discusses variable definition and variable area as it relates to C programming, focusing on how to reduce the size of the variable area . (a) Positioning of Object Placement in Memory Space Allocation of memory in systems with embedded F2MC-8L controllers is briefly discussed. (b) Variable Definition and Variable Area of Memory


Original
PDF CM25-00311-1E F9608 004C 007B C96F AA119
2000 - ASM 1042

Abstract: MB89PV620
Text: areas for variables that are initialized at definition and the variable area for those that are not. In , VARIABLE AREA " This chapter describes how to use variables declared with the type-qualifier "const" that , reduction of the variable area and object efficiency for referencing when the "const" type modifier is used. CHAPTER 4 "USING AUTOMATIC VARIABLES TO REDUCE THE VARIABLE AREA " This chapter explains how to reduce the variable area by using automatic variables. Area is allocated to automatic variables at execution time


Original
PDF CM25-00320-1E fcc896 fcc896 fcc896. ASM 1042 MB89PV620
2001 - UART Program Examples

Abstract: DCA04 AN2013 DCA05 DCA06
Text: Analyze M8C program variable area memory usage. Determine location of UART RX problem memory area . Determine a memory map that avoids the problem area . Create an options file to pass the variable area , areas. Proceed with normal development, correcting variable area mapping as needed. Code samples , ;- AREA bss(ram) _bss_start: Step 1: Analyze M8C program variable area memory usage: The M8C , 0x3f 0x40 to 0x8f 0x90 to 0xff The stack area should be placed after the last variable memory


Original
PDF AN2013 CY8C25xxx, CY8C26xxx 0x300x3f, UART Program Examples DCA04 AN2013 DCA05 DCA06
water level control circuit diagram

Abstract: circuit diagram water level sensor thermistor SCK 103 NTC NTC thermistor SCK 103 WATER LEVEL CONTROLLER water level sensor water level control water level sensor circuit diagram circuit diagram of process control of sequential timer using 3 relay MR321A
Text: No file text available


Original
PDF PD1713 PD17134A PD17135A PD17136A PD17137A water level control circuit diagram circuit diagram water level sensor thermistor SCK 103 NTC NTC thermistor SCK 103 WATER LEVEL CONTROLLER water level sensor water level control water level sensor circuit diagram circuit diagram of process control of sequential timer using 3 relay MR321A
CXV850

Abstract: No abstract text available
Text: 2-2. Display the Variable Information ( Variable List Panel) Toolbar Header area Information , List panel/ Variable List panel. All operations refer to the header area of each panel (the area where , 2.1 2.2 2.3 2.4 Overview . 18 Display Function Information . 20 Display Variable , to a variable . 28 2.7 Register Watch-Expressions . 29 2.8 Display List of Referencing Location , 33 2.10.1 Graph transitions in variable values . 34 2.10.2 Chart the function execution time


Original
PDF U19816EJ1V0UM CXV850
1995 - D350A

Abstract: pc9801 keyboard DP352 I80386 d352b D350 ID78K3 I80486 uPD78350 uPD78366
Text: . 91 Variable View dialog box. 93 Variable window. 95 Add Variable dialog box . 100 Local Variable window , . 91 Variable View Dialog Box


Original
PDF
water level sensor

Abstract: MR321A-12 thermistor SCK 103 NTC Thermistor cross reference sck 106 water dispenser block diagram circuit diagram of process control of sequential timer using 3 relay MR321 circuit diagram water level sensor WATER LEVEL CONTROLLER water level indicator using led and buzzer
Text: No file text available


Original
PDF
1995 - EM 235 setting

Abstract: DP352 pc9801 keyboard 9801 nec E001F D352B 4017 datasheets dip switches D350A LM 7801
Text: . 91 Variable View dialog box. 93 Variable window. 95 Add Variable dialog box . 100 Local Variable window , . 91 Variable View Dialog Box


Original
PDF ID78K3 PC-9801 U10441EJ1V0UM00 EM 235 setting DP352 pc9801 keyboard 9801 nec E001F D352B 4017 datasheets dip switches D350A LM 7801
2005 - PI-MBUS-300

Abstract: MRC 100-6 c3001a STS Bv 1500 current transformers 110B AWG14 CRC-16 omron modbus bv 1500 sts
Text: . 2-9 Read Variable Area . 2-9 Write Variable Area , . 2-20 SECTION 3 Communications Data for CompoWay/F and SYSWAY 3.1 Variable Area (Setting , . 5-6 5.3 Variable Area , . 5-9 Read Variable Area


Original
PDF 11-segment H135-E1-01 ma-81-300/Fax: 6835-3011/Fax: 10-8391-3005/Fax: 847-843-7900/Fax: PI-MBUS-300 MRC 100-6 c3001a STS Bv 1500 current transformers 110B AWG14 CRC-16 omron modbus bv 1500 sts
5b16

Abstract: C602 C607 HCS12 HCS12X 1803b0002101 186A0 00E0802F
Text: attribute _SHORT_SEG. · Defining & Accessing Data on Direct Addressing Area : 1. Variable definition is , following topics: · Variables allocated in direct addressing area · Variables allocated in extended addressing area · Variables allocated in banked addressing area ­ Using Logical Addresses · Variables allocated in banked addressing area ­ Using Global Addresses · Banked Constant allocation · Logical Addresses vs. Global Addresses For each of the variable type enumerated above, we will describe: · How to


Original
PDF HCS12X HCS12X 5b16 C602 C607 HCS12 1803b0002101 186A0 00E0802F
D4021

Abstract: a4504 stk 142 150 i80486 9000301a b027 a00a I80386 pc9801 keyboard ID78K4
Text: . 94 Variable View dialog box . 96 Variable window. 98 Add Variable dialog box. 103 Local Variable window , . 94 Fig. 5-13 Variable View Dialog Box


Original
PDF ID78K4 PC-9801 U10440EJ2V0UM00 IEU-1412) D4021 a4504 stk 142 150 i80486 9000301a b027 a00a I80386 pc9801 keyboard ID78K4
a006

Abstract: V851 uPD70F3008Y uPD70F3008 uPD703008Y uPD703008 IE-703002-MC ID78K4-NS a00a V852
Text: variable names, enumeration variable names, array names, structure names, union names) Function names , name, or variable name is described as a symbol, the address is operated on as a symbol value. · , structures and the unions of the C language. A structure is called by using a variable in the structure or , ( variable , line, task, etc.), the corresponding debugging function is selected by using a button (function , FUNCTIONS ( 9 ) Status bar The status bar is an area that shows the states of the debugger and the


Original
PDF ID78K4-NS IE-703008-MC-EM1 IE-703002-MC, V851TM V852TM. sampling--------------------------74 Sampling-------------------------------37 function---------------96, surement------------------------------170 a006 V851 uPD70F3008Y uPD70F3008 uPD703008Y uPD703008 IE-703002-MC ID78K4-NS a00a V852
stk 142 150

Abstract: i486DX2 66 NEC 9801 intel i486DX2 I80486 i486dx2 a00a a006 80486SX V852
Text: name and line number display column in status display area ) · Saves value of MM register to , , Variable Window, V850 Simulator GUI window, and Parts window) [Correction due to change of , external parts on CPU reset · Can be mapped as emulation ROM/RAM area · Search window added · Uninitialize Mem read break added Function deleted · Trace Timetag area of Extended , variables and arguments of functions" in Variable Window · When access event is specified in event


Original
PDF ID850 SM850 U11196EJ2V0UM00 80486SX Windows95 stk 142 150 i486DX2 66 NEC 9801 intel i486DX2 I80486 i486dx2 a00a a006 V852
Supplyframe Tracking Pixel