The Datasheet Archive

USA/0898/15K/MS Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
2011 - emergency stop relay a1

Abstract: G505 AC280
Text: Typical response time 50 ms (manual start) 60 ms (automatic start) Typical release time 20 ms (when controlled via S11/S12 and S21/S22) 500 ms (when controlled via A1) 50 ms (at 24 V DC) 110 ms (for 120 V AC) 280 ms (for 230 V AC) Concurrence input 1/2 Infinite Recovery time 1s , ) Interrupting rating (ohmic load) max. 192 W (24 V DC, = 0 ms ) 2 2 2 2 2 384 W (48 V DC, = 0 ms ) 80 W (110 V DC, = 0 ms ) 66 W (220 V DC, = 0 ms ) 2000 VA (250 V AC, = 0 ms ) Maximum


Original
PDF PSR-SCP-24-230UC/ESAM4/3X1/1X2 IF-2009) S33/S35: PSR-SCP-24-230UC/ESAM4/3X1/1X2 emergency stop relay a1 G505 AC280
2011 - phoenix fast fuse

Abstract: G542
Text: 20 ms PHOENIX CONTACT Inc., USA http://www.phoenixcon.com Page 1 / 5 May 11, 2011 PSR-SCP , =2981402 Typical release time 20 ms Output data Contact type 5 N/O, 2 N/C contacts Contact material , ) max. 144 W (24 V DC, = 0 ms ) 2 2 2 2 2 288 W (48 V DC, = 0 ms ) 110 W (110 V DC, = 0 ms ) 88 W (220 V DC, = 0 ms ) 1500 VA (250 V AC, = 0 ms ) Maximum interrupting rating (inductive load) 42 W (24 V DC, = 40 ms ) 42 W (48 V DC, = 40 ms ) 42 W (110 V DC, = 40 ms ) 42 W (220


Original
PDF PSR-SCP-120UC/URM/5X1/2X2 IF-2009) PSR-SCP-120UC/URM/5X1/2X2 phoenix fast fuse G542
2010 - phoenix fast fuse

Abstract: No abstract text available
Text: to UN Typical input current at UN Typical response time 24 V AC/DC 0.8 . 1.1 47 mA 20 ms PHOENIX , rating (ohmic load) max. 20 ms 5 N/O, 2 N/C contacts AgSnO2, + 0.2 µm Au 250 V AC/DC 15 V AC/DC 6A 6A 25 mA 72 A (ITH = I1 + I2 + . + I5 ) 144 W (24 V DC, = 0 ms ) 288 W (48 V DC, = 0 ms ) 110 W (110 V DC, = 0 ms ) 88 W (220 V DC, = 0 ms ) 1500 VA (250 V AC, = 0 ms ) 2 2 2 2 2 Maximum interrupting rating (inductive load) 42 W (24 V DC, = 40 ms ) 42 W (48 V DC, = 40 ms ) 42 W (110 V DC, = 40


Original
PDF 24UC/URM/5X1/2X2 IF-2009) 24UC/URM/5X1/2X2 phoenix fast fuse
2010 - Not Available

Abstract: No abstract text available
Text: Interrupting rating (ohmic load) max. Approx. 24 V DC 70 ms (manual start) 600 ms (Auto-start) 20 ms , = I1 + I2 + I3 + I4 + I5 ) 144 W (24 V DC, = 0 ms ) 288 W (48 V DC, = 0 ms ) 110 W (110 V DC, = 0 ms ) 88 W (220 V DC, = 0 ms ) 1500 VA (250 V AC, = 0 ms ) 2 2 2 2 2 2 2 Maximum interrupting rating (inductive load) 42 W (24 V DC, = 40 ms ) 42 W (48 V DC, = 40 ms ) 42 W (110 V DC, = 40 ms ) 42 W (220 V DC, = 40 ms ) Switching capacity min. Output fuse 0.4 W 6 A fast blow (undelayed) C6


Original
PDF 24DC/ESD/5X1/1X2/ IF-2009)
2010 - W-48

Abstract: No abstract text available
Text: rating (ohmic load) max. Approx. 24 V DC 20 ms (Monitored/manual start) 45 ms (Single-channel) 10 ms , I3 ) 144 W (24 V DC, = 0 ms ) 288 W (48 V DC, = 0 ms ) 77 W (110 V DC, = 0 ms ) 88 W (220 V DC, = 0 ms ) 1500 VA (250 V AC, = 0 ms ) 2 2 2 2 2 Maximum interrupting rating (inductive load) 48 W (24 V DC, = 40 ms ) 40 W (48 V DC, = 40 ms ) 35 W (110 V DC, = 40 ms ) 35 W (220 V DC, = 40 ms


Original
PDF 24UC/ESM4/3X1/1X2/B IF-2009) S33/S35) 24UC/ESM4/3X1/1X2/B W-48
2011 - phoenix contacts 30 25 04 0

Abstract: No abstract text available
Text: Typical response time 150 ms (Monitored/manual and auto-start) Typical release time 20 ms (undelayed contacts) 100 ms (delayed contacts) Typical release time range 0.1 s . 30 s Recovery time 330 ms (Restart) 1 s (Electric torque) Max. permissible overall conductor resistance 50 , Inrush current, minimum 25 mA Interrupting rating (ohmic load) max. 144 W (24 V DC, = 0 ms ) 288 W (48 V DC, = 0 ms ) 90 W (110 V DC, = 0 ms ) 88 W (220 V DC, = 0 ms ) 1500 VA (250 V AC, = 0


Original
PDF 24DC/ESD/4X1/30 IF-2009) 24DC/ESD/4X1/30 phoenix contacts 30 25 04 0
2011 - Not Available

Abstract: No abstract text available
Text: input/start and feedback circuit Approx. 24 V DC Typical response time 70 ms (manual start) 600 ms (Auto-start) Typical release time 20 ms (undelayed contacts) Typical release time , (ohmic load) max. 144 W (24 V DC, = 0 ms ) 2 2 2 2 2 2 2 288 W (48 V DC, = 0 ms ) 77 W (110 V DC, = 0 ms ) 88 W (220 V DC, = 0 ms ) 1500 VA (250 V AC, = 0 ms ) Maximum interrupting rating (inductive load) 42 W (24 V DC, = 40 ms ) 40 W (48 V DC, = 40 ms ) 35 W (110 V DC, =


Original
PDF 24DC/ESD/5X1/1X2/300 IF-2009) 24DC/ESD/5X1/1X2/300
2010 - Not Available

Abstract: No abstract text available
Text: 25 ms (100 ms automatic start) 10 ms Infinite 1s 3 enabling current paths, 1 signaling current , , = 0 ms ) 288 W (48 V DC, = 0 ms ) 77 W (110 V DC, = 0 ms ) 88 W (220 V DC, = 0 ms ) 1500 VA (250 V AC, = 0 ms ) 2 2 2 2 2 Maximum interrupting rating (inductive load) 48 W (24 V DC, = 40 ms ) 40 W (48 V DC, = 40 ms ) 35 W (110 V DC, = 40 ms ) 33 W (220 V DC, = 40 ms ) Switching capacity min


Original
PDF 24UC/ESL4/3X1/1X2/B IF-2009) Te/S35) 24UC/ESL4/3X1/1X2/B
2010 - Not Available

Abstract: No abstract text available
Text: Interrupting rating (ohmic load) max. Approx. 24 V DC 70 ms (manual start) 600 ms (Auto-start) 20 ms , = I1 + I2 + I3 + I4 + I5 ) 144 W (24 V DC, = 0 ms ) 288 W (48 V DC, = 0 ms ) 110 W (110 V DC, = 0 ms ) 88 W (220 V DC, = 0 ms ) 1500 VA (250 V AC, = 0 ms ) 2 2 2 2 2 2 2 Maximum interrupting rating (inductive load) 42 W (24 V DC, = 40 ms ) 42 W (48 V DC, = 40 ms ) 42 W (110 V DC, = 40 ms ) 42 W (220 V DC, = 40 ms ) Switching capacity min. Output fuse 0.4 W 6 A fast blow (undelayed) C6


Original
PDF 24DC/ESD/5X1/1X2/ IF-2009)
2010 - Not Available

Abstract: No abstract text available
Text: 60 ms (man. start) 250 ms (Auto-start) 20 ms Infinite 1s Approx. 11 (Input and start circuits at UN , 25 mA 50 A (ITH = I1 + I2 + . + I8 ) 144 W (24 V DC, = 0 ms ) 288 W (48 V DC, = 0 ms ) 110 W (110 V DC, = 0 ms ) 88 W (220 V DC, = 0 ms ) 1500 VA (250 V AC, = 0 ms ) 2 2 2 2 2 Maximum interrupting rating (inductive load) 42 W (24 V DC, = 40 ms ) 42 W (48 V DC, = 40 ms ) 42 W (110 V DC, = 40 ms ) 42 W (220 V DC, = 40 ms ) Switching capacity min. Output fuse 0.4 W 6 A fast blow C6 (24 V AC/DC


Original
PDF 24UC/ESAM4/8X1/1X2 IF-2009) 24UC/ESAM4/8X1/1X2
2010 - 4017

Abstract: No abstract text available
Text: Output data Contact type 4 N/O, 2 N/C contacts 120 V AC/DC 0.8 . 1.1 12 mA 10 ms 10 ms PHOENIX , (total current on request) 6A 25 mA 144 W (24 V DC, = 0 ms ) 288 W (48 V DC, = 0 ms ) 77 W (110 V DC, = 0 ms ) 88 W (220 V DC, = 0 ms ) 1500 VA (250 V AC, = 0 ms ) Maximum interrupting rating (inductive load) 48 W (24 V DC, = 40 ms ) 40 W (48 V DC, = 40 ms ) 35 W (110 V DC, = 40 ms ) 33 W (220 V DC, = 40 ms ) Switching capacity min. Output fuse 0.4 W 10 A gL/gK NEOZED (N/O contact) 4 A gL/gK


Original
PDF PSR-SPF-120UC/URM/4X1/2X2 IF-2009) PSR-SPF-120UC/URM/4X1/2X2 4017
2010 - Not Available

Abstract: No abstract text available
Text: 1.1 11 mA 20 ms 20 ms PHOENIX CONTACT Inc., USA http://www.phoenixcon.com Page 1 / 5 Jul 23 , mA 72 A (ITH = I1 + I2 + . + I5 ) 144 W (24 V DC, = 0 ms ) 288 W (48 V DC, = 0 ms ) 110 W (110 V DC, = 0 ms ) 88 W (220 V DC, = 0 ms ) 1500 VA (250 V AC, = 0 ms ) Maximum interrupting rating (inductive load) 42 W (24 V DC, = 40 ms ) 42 W (48 V DC, = 40 ms ) 42 W (110 V DC, = 40 ms ) 42 W (220 V DC, = 40 ms ) Switching capacity min. Output fuse 0.4 W 6 A fast blow C6 (24 V AC/DC) automatic device General


Original
PDF PSR-SPP-120UC/URM/5X1/2X2 IF-2009) TerPSR-SPP-120UC/URM/5X1/2X2 PSR-SPP-120UC/URM/5X1/2X2
2010 - G-521

Abstract: No abstract text available
Text: Interrupting rating (ohmic load) max. Approx. 24 V DC 70 ms (manual start) 600 ms (Auto-start) 20 ms , = I1 + I2 + I3 + I4 + I5 ) 144 W (24 V DC, = 0 ms ) 288 W (48 V DC, = 0 ms ) 110 W (110 V DC, = 0 ms ) 88 W (220 V DC, = 0 ms ) 1500 VA (250 V AC, = 0 ms ) 2 2 2 2 2 2 2 Maximum interrupting rating (inductive load) 42 W (24 V DC, = 40 ms ) 42 W (48 V DC, = 40 ms ) 42 W (110 V DC, = 40 ms ) 42 W (220 V DC, = 40 ms ) Switching capacity min. Output fuse 0.4 W 6 A fast blow (undelayed) C6


Original
PDF 24DC/ESD/5X1/1X2/ IF-2009) G-521
2010 - Not Available

Abstract: No abstract text available
Text: Interrupting rating (ohmic load) max. Approx. 24 V DC 70 ms (manual start) 600 ms (Auto-start) 20 ms , = I1 + I2 + I3 + I4 + I5 ) 144 W (24 V DC, = 0 ms ) 288 W (48 V DC, = 0 ms ) 110 W (110 V DC, = 0 ms ) 88 W (220 V DC, = 0 ms ) 1500 VA (250 V AC, = 0 ms ) 2 2 2 2 2 2 2 Maximum interrupting rating (inductive load) 42 W (24 V DC, = 40 ms ) 42 W (48 V DC, = 40 ms ) 42 W (110 V DC, = 40 ms ) 42 W (220 V DC, = 40 ms ) Switching capacity min. Output fuse 0.4 W 6 A fast blow (undelayed) C6


Original
PDF 24DC/ESD/5X1/1X2/2T IF-2009)
2010 - Not Available

Abstract: No abstract text available
Text: Interrupting rating (ohmic load) max. Approx. 24 V DC 70 ms (manual start) 600 ms (Auto-start) 20 ms , = I1 + I2 + I3 + I4 + I5 ) 144 W (24 V DC, = 0 ms ) 288 W (48 V DC, = 0 ms ) 110 W (110 V DC, = 0 ms ) 88 W (220 V DC, = 0 ms ) 1500 VA (250 V AC, = 0 ms ) 2 2 2 2 2 2 2 Maximum interrupting rating (inductive load) 42 W (24 V DC, = 40 ms ) 42 W (48 V DC, = 40 ms ) 42 W (110 V DC, = 40 ms ) 42 W (220 V DC, = 40 ms ) Switching capacity min. Output fuse 0.4 W 6 A fast blow (undelayed) C6


Original
PDF 24DC/ESD/5X1/1X2/ IF-2009)
2010 - SDC4

Abstract: No abstract text available
Text: Interrupting rating (ohmic load) max. Approx. 24 V DC 20 ms (150 ms automatic start) 10 ms 1s 50 (Input and , 15 V AC/DC 6 A (N/O contact) 100 mA (signal output) 6A 25 mA 72 A 2 144 W (24 V DC, = 0 ms ) 288 W (48 V DC, = 0 ms ) 77 W (110 V DC, = 0 ms ) 88 W (220 V DC, = 0 ms ) 1500 VA (250 V AC, = 0 ms ) Maximum interrupting rating (inductive load) 48 W (24 V DC, = 40 ms ) 40 W (48 V DC, = 40 ms ) 35 W (110 V DC, = 40 ms ) 33 W (220 V DC, = 40 ms ) Switching capacity min. Output fuse General data


Original
PDF 24DC/SDC4/2X1/B IF-2009) 24DC/SDC4/2X1/B SDC4
2010 - Not Available

Abstract: No abstract text available
Text: . 24 V DC 70 ms (manual start) 600 ms (Auto-start) 20 ms (undelayed contacts) Infinite 1s 11 (Input , W (24 V DC, = 0 ms ) 288 W (48 V DC, = 0 ms ) 110 W (110 V DC, = 0 ms ) 88 W (220 V DC, = 0 ms ) 1500 VA (250 V AC, = 0 ms ) 2 2 2 2 2 2 2 Maximum interrupting rating (inductive load) 42 W (24 V DC, = 40 ms ) 42 W (48 V DC, = 40 ms ) 42 W (110 V DC, = 40 ms ) 42 W (220 V DC, = 40 ms


Original
PDF 24DC/ESD/5X1/1X2/1T IF-2009)
2010 - Not Available

Abstract: No abstract text available
Text: . 24 V DC 70 ms (manual start) 600 ms (Auto-start) 20 ms (undelayed contacts) Infinite 1s 11 (Input , W (24 V DC, = 0 ms ) 288 W (48 V DC, = 0 ms ) 110 W (110 V DC, = 0 ms ) 88 W (220 V DC, = 0 ms ) 1500 VA (250 V AC, = 0 ms ) 2 2 2 2 2 2 2 Maximum interrupting rating (inductive load) 42 W (24 V DC, = 40 ms ) 42 W (48 V DC, = 40 ms ) 42 W (110 V DC, = 40 ms ) 42 W (220 V DC, = 40 ms


Original
PDF 24DC/ESD/5X1/1X2/0T IF-2009)
2010 - Not Available

Abstract: No abstract text available
Text: current Inrush current, minimum Sq. Total current Interrupting rating (ohmic load) max. 70 ms (Monitored/manual start) 600 ms (Auto-start) 20 ms (undelayed contacts) 0.2 s . 300 s Infinite 1s 11 , I1 + I2 + I3 + I4 + I5 ) 144 W (24 V DC, = 0 ms ) 288 W (48 V DC, = 0 ms ) 77 W (110 V DC, = 0 ms ) 88 W (220 V DC, = 0 ms ) 1500 VA (250 V AC, = 0 ms ) 2 2 2 2 2 2 2 Maximum interrupting rating (inductive load) 42 W (24 V DC, = 40 ms ) 40 W (48 V DC, = 40 ms ) 35 W (110 V DC, = 40 ms ) 33 W (220 V


Original
PDF 24DC/ESD/5X1/1X2/300 IF-2009) 24DC/ESD/5X1/1X2/300
2011 - G503

Abstract: No abstract text available
Text: feedback circuit Approx. 24 V DC Typical response time 100 ms (automatic start) Typical release time 45 ms (single-channel) 10 ms (two-channel) Concurrence input 1/2 Infinite Recovery , (ohmic load) max. 144 W (24 V DC, = 0 ms ) 2 2 2 2 288 W (48 V DC, = 0 ms ) 77 W (110 V DC, = 0 ms ) 88 W (220 V DC, = 0 ms ) 1500 VA (250 V AC, = 0 ms ) Maximum interrupting rating (inductive load) 48 W (24 V DC, = 40 ms ) 40 W (48 V DC, = 40 ms ) 35 W (110 V DC, = 40 ms ) 35 W (220


Original
PDF 24UC/ESA4/2X1/1X2 IF-2009) 24UC/ESA4/2X1/1X2 G503
2011 - Not Available

Abstract: No abstract text available
Text: current max. 100 mA Typical response time 50 ms Typical release time 50 ms Recovery time , + IN ) Interrupting rating (ohmic load) max. 120 W (24 V DC, τ = 0 ms , N/C contact: 2.4 W) 2 2 2 2 2 192 W (48 V DC, τ = 0 ms , N/C contact: 4.8 W) 162 W (60 V DC, τ = 0 ms , N/C contact: 6 W) 66 W (110 V DC, τ = 0 ms , N/C contact: 11 W) 60 W (220 V DC, τ = 0 ms , N/C contact: 22 W) 1250 VA (250 V AC, τ = 0 ms , N/C contact: 25 VA) Maximum interrupting rating (inductive


Original
PDF 24DC/FSP/2X1/1X2 NTK-2010) 24DC/FSP/2X1/1X2
2010 - Not Available

Abstract: No abstract text available
Text: 11 mA 20 ms PHOENIX CONTACT Inc., USA http://www.phoenixcon.com Page 1 / 5 Jul 22, 2010 , , minimum Sq. Total current Interrupting rating (ohmic load) max. 20 ms 5 N/O, 2 N/C contacts AgSnO2 , ms ) 288 W (48 V DC, = 0 ms ) 110 W (110 V DC, = 0 ms ) 88 W (220 V DC, = 0 ms ) 1500 VA (250 V AC, = 0 ms ) 2 2 2 2 2 Maximum interrupting rating (inductive load) 42 W (24 V DC, = 40 ms ) 42 W (48 V DC, = 40 ms ) 42 W (110 V DC, = 40 ms ) 42 W (220 V DC, = 40 ms ) Switching capacity min


Original
PDF PSR-SCP-120UC/URM/5X1/2X2 IF-2009) EEE/RoHS-compliaPSR-SCP-120UC/URM/5X1/2X2 PSR-SCP-120UC/URM/5X1/2X2
2010 - Not Available

Abstract: No abstract text available
Text: current at UN Typical response time 24 V AC/DC 0.8 . 1.1 47 mA 20 ms PHOENIX CONTACT Inc., USA http , current Inrush current, minimum Sq. Total current Interrupting rating (ohmic load) max. 20 ms 5 N/O , ) 144 W (24 V DC, = 0 ms ) 288 W (48 V DC, = 0 ms ) 110 W (110 V DC, = 0 ms ) 88 W (220 V DC, = 0 ms ) 1500 VA (250 V AC, = 0 ms ) 2 2 2 2 2 Maximum interrupting rating (inductive load) 42 W (24 V DC, = 40 ms ) 42 W (48 V DC, = 40 ms ) 42 W (110 V DC, = 40 ms ) 42 W (220 V DC, = 40 ms ) Switching


Original
PDF 24UC/URM/5X1/2X2 IF-2009) 24UC/URM/5X1/2X2
2011 - G542

Abstract: phoenix fast fuse
Text: response time 20 ms PHOENIX CONTACT Inc., USA http://www.phoenixcon.com Page 1 / 5 May 11, 2011 , /treeViewClick.do?UID=2963747 Typical release time 20 ms Output data Contact type 5 N/O, 2 N/C contacts , (ohmic load) max. 144 W (24 V DC, = 0 ms ) 2 2 2 2 2 288 W (48 V DC, = 0 ms ) 110 W (110 V DC, = 0 ms ) 88 W (220 V DC, = 0 ms ) 1500 VA (250 V AC, = 0 ms ) Maximum interrupting rating (inductive load) 42 W (24 V DC, = 40 ms ) 42 W (48 V DC, = 40 ms ) 42 W (110 V DC, = 40 ms ) 42 W (220


Original
PDF 24UC/URM/5X1/2X2 IF-2009) 24UC/URM/5X1/2X2 G542 phoenix fast fuse
2010 - cross reference relay

Abstract: No abstract text available
Text: 52 mA 10 ms PHOENIX CONTACT Inc., USA http://www.phoenixcon.com Page 1 / 4 Jul 23, 2010 , , minimum Interrupting rating (ohmic load) max. 10 ms 4 N/O, 2 N/C contacts AgSnO2 250 V AC/DC 15 V AC/DC 6 A (total current on request) 6A 25 mA 144 W (24 V DC, = 0 ms ) 288 W (48 V DC, = 0 ms ) 77 W (110 V DC, = 0 ms ) 88 W (220 V DC, = 0 ms ) 1500 VA (250 V AC, = 0 ms ) Maximum interrupting rating (inductive load) 48 W (24 V DC, = 40 ms ) 40 W (48 V DC, = 40 ms ) 35 W (110 V DC, = 40 ms ) 33 W (220 V


Original
PDF 24UC/URM/4X1/2X2 IF-2009) 24UC/URM/4X1/2X2 cross reference relay